A- ELEVATION ITEMS:
01-Fly Nets:
02-Roll-up shutters:
Rollup shutter sample
- Rollup shutter must be installed as per
the attached sketch.
- Color of roll-up shutters strips must be
white (9010).
1|Page
Technical Guidelines and conditions (Diplo)
2|Page
Technical Guidelines and conditions (Diplo)
04-A/C Compressors Location:
- Air condition compressors locations are limited to the locations shown in this manual for each type.
And it’s not allowed to install air-condition compressors anywhere else.
- All A.C units must have an internal drainage to the nearest floor drain.
- It’s not allowed at all to make any external drainage (on elevations).
3|Page
Technical Guidelines and conditions (Diplo)
4|Page
Technical Guidelines and conditions (Diplo)
5|Page
Technical Guidelines and conditions (Diplo)
05-Doors & Windows Glass:
06-Main Doors:
- The only design permitted of main doors is as following with Varnished (Ostor) paint.
6|Page
Technical Guidelines and conditions (Diplo)
7|Page
Technical Guidelines and conditions (Diplo)
07-Terraces drainage system:
8|Page
Technical Guidelines and conditions (Diplo)
B- GARDEN ITEMS:
01-Pergolas:
- Back & side yard pergolas:
Garden pergolas must be at least 2m away from the side fence along building can be attached with
the fence along back yard (as per the attached sketch).
Garden pergolas maximum area must be 25% from back yard area with minimum area 15 m2 if
needed.
The material used must be the same material as the compound pergolas wood with (Brown color).
Garden pergolas design must be as per the attached design.
Maximum height of pergolas must be 3.0 m from finish floor.
9|Page
Technical Guidelines and conditions (Diplo)
10 | P a g e
Technical Guidelines and conditions (Diplo)
02-Water Features:
- Swimming Pools, Underground water
tanks & Fountains
Water features design and location must
be approved before execution.
Water features are not allowed in front
yard, or in narrow side yards.
The required documents should be
presented by client to approve water
features design:
i- General layout drawing for plot
contains:
o Pool location in back-yard.
o Dimension between pool and side, back
fences and villa
o Distance between foundations (Villa-
Pool)
ii- Longitude section for pool contain
pool depth and foundation levels for
(villa, pool and fences)
iii- In case of conflicting between
foundation levels for both of villa
and pool client should present signed
structural drawings from union
consultant shows retaining soil under
villa foundations.
iv- Full drawings package for pool
(Architectural – Structural –
Mechanical)
v- Signed undertake from client ensures
his responsibility about construction
and building safety.
Note:
All previous documents & drawings should be
presented as a hard copy attached with
AutoCad files if possible.
11 | P a g e
Technical Guidelines and conditions (Diplo)
03-Fences and gates:
- Property limits are delineated by
Mountain View fences.
- Modifying or adding front fences is not
allowed anyway.
- Back fences should be only softscape
(fence arboreal) behind existing stone
fence with maximum height 0.9 m.
- Side fences can be Soft scape or builder
with height 0.90m along 7.50m from
back fences and it increased gradually to
2.00m.
- Side and back fences are allowed to be
covered by shrubs or bushes without
exceeding the allowed fence height.
12 | P a g e
Technical Guidelines and conditions (Diplo)
04-SOFTSCAPE
05-Hardscape
06-Showers:
07-Garden Furniture:
13 | P a g e
Technical Guidelines and conditions (Diplo)
08-Water Tanks:
14 | P a g e
Technical Guidelines and conditions (Diplo)
C- Roof Items:
01-Satellite Dish:
Villas:
15 | P a g e
Technical Guidelines and conditions (Diplo)
02-Roof Separator:
Option 2:
Wooden separator as per the following design
with maximum height 2.0m.
16 | P a g e
Technical Guidelines and conditions (Diplo)
03-Roof Lighting:
17 | P a g e
Technical Guidelines and conditions (Diplo)
05-Roof Pergolas:
18 | P a g e
Technical Guidelines and conditions (Diplo)
06-Roof Water Tank:
19 | P a g e
Technical Guidelines and conditions (Diplo)
07-Roof Jacuzzy:
20 | P a g e