ETABS 2016 16.2.

1 License #*16TAJDXL9PWRGQ2

Story Response - Maximum Story Drifts


Summary Description
This is story response output for a specified range of stories and a selected load case or load combination.

Input Data

Name StoryResp2

Display Type Max story drifts Story Range All Stories

Load Case EQx - Top Story last floor

Output Type Not Applicable Bottom Story base

Plot

Maximum Story Drifts


last floor

first floor

Ground floor

ground beam

base
0 20 40 60 80 100 120 140 160 180 200 E-6

Drift, Unitless

PROJECT1.EDB Page 1 of 2 13/06/1439


ETABS 2016 16.2.1 License #*16TAJDXL9PWRGQ2

Tabulated Plot Coordinates

Story Response Values

Story Elevation Location X-Dir Y-Dir


m
last floor 11.7 Top 0.000088 0.00001
first floor 8.7 Top 0.00013 0.000015
Ground floor 5.4 Top 0.000152 0.000025
ground beam 1.8 Top 0.000082 0.00001
base 0 Top 0 0

PROJECT1.EDB Page 2 of 2 13/06/1439