Striking differences in usability Choose your imager, select the Mammo option of the DRYSTAR 5503, DRYSTAR IMAGERS

choose your media the media you want is our DRYSTAR DT2 Mammo.
How many media sizes do you want on-line – If the DRYSTAR 4500M is the right imager for you,
If the similarities between DRYSTAR imagers are 1, 2 or 3? What sizes of media do you use: DRYSTAR Mammo media will give you the optimum
Follow the question tree to find the DRYSTAR
reassuring, it’s the differences that tell you which 8 x 10 inch, 10 x 12 inch, 11 x 14 inch, 14 x 14 inch digital mammography imaging you need.
imager that fits your needs. Start by choosing a
one is right for you. Each satisfies diverse and or 14 x 17 inch? Blue base, clear base or both?
centralized imaging set-up - with a limited number
specific requirements: Do you need to make high diagnostic-quality It’s a whole family of media to match our family
of imagers used by multiple departments -
of imagers.
DRYSTAR 5503: Our all-in-one, or a decentralized arrangement - with smaller, mammography images?
centralized imager for all applications specialized imagers available at key locations
throughout your facility. Next, select the
Our knowledge at your
DRYSTAR 5302: Our imager for day-to-day
applications you need to run. The question tree
Your media usage says a lot about your facility and fingertips
CR/DR applications your imaging needs. Each of our imager trays can When you’ve been in a business for over 100 years,
will then illustrate the best Agfa imager for you!
DRYSTAR 5300: The right decentralized imager handle different media sizes, ensuring you the you can learn a lot about it, and we have learned
for CT/MR applications flexibility you want. And with heat-sensitive instead plenty about the world of imaging, and of healthcare
DRYSTAR 4500M: Our dedicated stand-alone of light-sensitive media, the imagers offer complete delivery in general. For example, what you need to
imager for Mammography daylight handling, allowing you to open trays, load make a good diagnosis, what tools can help you
media, etc., without any concerns. improve your efficiency and workflow, which service
needs are the same across the healthcare sector and they say you can’t choose your family
No matter which DRYSTAR hardcopy imager you which vary from facility to facility. but with Agfa’s range of
use or how you use it, there is a DRYSTAR media
This knowledge is not only a core part of what we

DRYSTAR imagers
that will give you what you want. For the DRYSTAR
do, but also of who we are. And with our complete
5300, 5302 and 5503, we propose the DRYSTAR
DRYSTAR family of imagers, we put it all at
WORKFLOW DT2 Direct Digital grayscale media. When you
your fingertips.



DECENTRALIZED that’s just what we did
CENTRALIZED

▼ ▼

APPLICATION APPLICATION

▼ ▼ ▼
▼ ▼
CT/MR CR/DR CT/MR MAMMO CR/DR


Including
Mammography, high
resolution and/or high Agfa, the Agfa rhombus. and DRYSTAR are trademarks of Agfa-Gevaert N.V., Belgium or its affiliates. © Copyright 2006 Agfa-Gevaert N.V.
▼ throughput ▼ ▼ ▼ All other trademarks are held by their respective owners and are used in an editorial fashion with no All rights reserved
intention of infringement.
YES ▼
NO The data in this publication are for illustration purposes only and do not necessarily represent
Printed in Belgium

standards or specifications which must be met by Agfa. All information contained herein is intended
for guidance purposes only, and characteristics of the products described in this publication can be
changed at any time without notice. Published by
Products may not be available for your local area. Please contact your local sales representative for
availability information.
Agfa-Gevaert N.V.
Agfa diligently strives to provide as accurate information as possible, but shall not be responsible B-2640 Mortsel
for any typographical error.
Agfa-Gevaert N.V. has been awarded the ISO 9001 certificate by Lloyd's Register Quality Assurance. Belgium
DRYSTAR DRYSTAR DRYSTAR DRYSTAR DRYSTAR The business group HealthCare has been awarded the ISO 13485 certificate for design, development
5300 4500M 5302 and production of imaging and communication solutions for healthcare applications. NGKMB GB 00200605
5503 5302

www.agfa.com/healthcare
great similarities DRYSTAR 5503 DRYSTAR 5302
TECHNICAL SPECIFICATIONS

DRYSTAR 5300 DRYSTAR 4500M


in benefits
GENERAL GENERAL GENERAL GENERAL
Dimensions & weight Dimensions & weight Dimensions & weight Dimensions & weight
• Dimensions: • Dimensions: • Dimensions: • Dimensions:
72 x 71,5 x 141 cm (W x D x H) 72,8 x 71,5 x 53,6 cm (W x D x H) 70 x 80 x 35 cm (W x D x H) 55 x 72 x 92 cm (W x D x H)
Whichever Agfa DRYSTAR hardcopy imager All DRYSTAR imagers come with Agfa’s DDI (28,3 x 28,1 x 55,5 inch) (H = 67,6 cm with output tray) (27.5 x 31.5 x 13.8 inch) (21.6 x 28.3 x 36.2 inch)
you choose, you always know you get the enhanced with A#Sharp, built right in, so • Weight: 193 kg (425 lb) (28,7 x 28,1 x 21,1 inch) • Weight: 55 kg (121 lb) • Weight: 95 kg (209.4 lb)
Number of trays • Weight: 90 kg (198 lb) Number of trays Number of trays
best image quality and complete flexibility. there are no complex or expensive moving
• Three on-line sizes Number of trays • One size on-line • Two on-line sizes
Take a closer look, and you see Direct optical parts. • Two on-line sizes
Capacity of supply trays Capacity of supply trays Capacity of supply trays
Digital Imaging (DDI) with A#Sharp for It’s fast, clean, environmentally-friendly • All three trays configurable for 100 sheets Capacity of supply trays • 100 sheets • Upper input tray: 8 x 10 inch,
consistently sharp images; total daylight and requires less maintenance, all while of 8 x 10 inch, 10 x 12 inch, 11 x 14 inch, • All two trays configurable for 100 sheets 100 sheets
14 x 14 inch or 14 x 17 inch film of 8 x 10 inch, 10 x 12 inch, 11 x 14 inch, • Lower input tray: 8 x 10 inch or
handling for ease of use; high throughput providing even sharper images. The 508 ppi 14 x 14 inch or 14 x 17 inch film 10 x 12 inch (configurable), 100 sheets
and the shortest image access time for the resolution corresponds in a one-to-one ratio
PERFORMANCE PERFORMANCE PERFORMANCE PERFORMANCE
most efficient workflow; DICOM and the with the highest resolution digitizers, with Throughput Throughput Throughput Throughput
Paxport gateway for full integration and a scan resolution of 50 µm. • 8 x 10 inch: 160 sheets/hour • 8 x 10 inch: 140 sheets/hour • 11 x 14 inch: 100 sheets/hour • 8 x 10 inch: 80 sheets/hour
• 14 x 17 inch: 100 sheets/hour • 11 x 14 inch: 86 sheets/hour • 14 x 17 inch: 70 sheets/hour • 10 x 12 inch: 60 sheets/hour
networking; and, always, an excellent No image interpolation is necessary,
First film: 8 x 10 inch: 75 sec • 14 x 17 inch: 75 sheets/hour First film: 14 x 17 inch: 77 sec First film: 8 x 10 inch: 100 sec
price/performance ratio. so there are no image artifacts introduced. 14 x 17 inch: 57 sec First film: 14 x 17 inch: 77 sec Diagnostic area Diagnostic area
It’s the most efficient imager Diagnostic area Diagnostic area • 14 x 17 inch: 4256 x 5174 pixels • 8 x 10 inch: 3728 x 4672 pixels
DRYSTAR 5302 and 5300 have a modular • 8 x 10 inch: 3852 x 4880 pixels • 8 x 10 inch: 2376 x 3070 pixels • 11 x 14 inch: 3300 x 4256 pixels • 10 x 12 inch: 4672 x 5760 pixels
design, allowing easier care, shorter resolution possible. • 14 x 17 inch: 6922 x 8368 pixels • 10 x 12 inch: 3070 x 3653 pixels Printing resolution Diagnostic area for mammo application
Diagnostic area for mammo application • 14 x 17 inch: 4358 x 5232 pixels • Geometrical: 320 ppi • 8 x 10 inch: 3828 x 4958 pixels
downtime and lower maintenance costs. When you look at our range of DRYSTAR • 11 x 14 inch: 3348 x 4358 pixels
• 8 x 10 inch: 3828 x 4958 pixels Targetted applications* • 10 x 12 inch: 4892 x 5810 pixels
Whichever DRYSTAR imager you choose, hardcopy imagers, the family resemblance Printing resolution
Printing resolution • Geometrical: 320 ppi • CT/MR Printing resolution
the value and user-friendliness are is clear - it’s quality and usability, for every • Geometrical: 508 ppi Targetted applications* Sorter • Geometrical: 508 ppi
• Spot size: 50 µm • CR/DR • No Targetted applications*
long-term benefits. facility’s needs.
Targetted applications* Sorter Hard Drive for spooling • Mammography
• CR/DR • No • No; 512 Mbyte or 1 Gbyte in option Sorter
• CT/MR Hard Drive for spooling • No
• Mammography • 72 Gbyte Hard Drive for spooling
Sorter • 72 Gbyte
• Yes
Hard Drive for spooling
• 72 Gbyte

MEDIA TYPES AND SIZES MEDIA TYPES AND SIZES MEDIA TYPES AND SIZES MEDIA TYPES AND SIZES
Types Types Types Types
• DRYSTAR DT2 B: blue base • DRYSTAR DT2 B: blue base • DRYSTAR DT2 B: blue base • DRYSTAR DT1 B blue base media
• DRYSTAR DT2 C: clear base • DRYSTAR DT2 C: clear base • DRYSTAR DT2 C: clear base • DRYSTAR Mammo blue base media
• DRYSTAR DT2 Mammo Sizes Sizes optimized for mammography
Sizes • 8 x 10 inch, 10 x 12 inch, 11 x 14 inch, • 11 x 14 inch and 14 x 17 inch Sizes
• DRYSTAR DT2 B/C: 8 x 10 inch, 14 x 14 inch and 14 x 17 inch • 8 x 10 inch and 10 x 12 inch
10 x 12 inch, 11 x 14 inch, 14 x 14 inch
and 14 x 17 inch
• DT2 Mammo: 8 x 10 inch, 10 x 12 inch,
11 x 14 inch

* Next to the targetted applications, the printers can also support CR/DR, CT/MR, Mammography, Digital Fluoroscopy, PET, Ultrasound, Digital Subtraction Angiography and others