electric

MOTOR
POWER AT
400V
kW 0.37 0.75 1.5 2.2 3 4 5.5 0.37 0.75 1.5 2.2 3 4 5.5 7.5 9 11 15 18.5 22 30 37 45 55 59 75 90 110 132 160 200 250 315 355 450 630
HP 0.5 1 2 3 4 5.5 7.5 0.5 1 2 3 4 5.5 7.5 10 12 15 20 25 30 40 50 60 75 80 100 125 150 180 220 270 340 430 445 600 840
A (AC3) 1.1 1.9 3.5 5 6.6 8.6 11.5 1.1 1.9 3.5 5 6.6 8.6 11.5 15.2 18 22 28.5 36 42 56 68 83 98 105 135 158 193 232 282 349 430 545 610 810 –

Motor protection circuit breaker with three-pole contactor


Motor protection circuit breaker 11 SM1B 20 11 SM1B 24 11 SM1B 28 11 SM1B 32 11 SM1B 36 11 SM1B 36 11 SM1A 40 11 SM1B 20 11 SM1B 24 11 SM1B 28 11 SM1B 32 11 SM1B 36 11 SM1B 36 11 SM1A 40 11 SM1A 44 11 SM1A 48 11 SM1A 48 11 SM2A 64 11 SM2A 68 11 SM2A 72 11 SM3A 84 11 SM3A 88 11 SM3A 92 11 SM3A 96 – – – – – – – – – – – –
Thermal trip adjustment range [A] ▲ 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.5 6.3 - 10 6.3 - 10 9 - 14 1 - 1.6 1.6 - 2.5 2.5 - 4 4 - 6.5 6.3 - 10 6.3 - 10 9 - 14 13 - 18 17 - 23 17 - 23 22 - 32 28 - 40 36 - 45 45 - 63 57 - 75 70 - 90 80 - 100 – – – – – – – – – – – –
Icu 400V [kA] 100 100 100 100 100 100 50 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 50 50 – – – – – – – – – – – –

Breaker
AC contactor 11 BG06 1 A 2 11 BG06 1 A 2 11 BG06 1 A 2 11 BG06 1 A 2 11 BG09 1 A 2 11 BG09 1 A 2 11 BG12 1 A 2 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF12 1 4 11 BF16 1 4 11 BF20 00 4 11 BF25 00 4 11 BF32 00 4 11 BF40 00 4 11 BF50 00 4 11 BF65 00 4 11 BF80 00 4 11 BF95 00 4
11 B115 00 5 11 B115 00 5 11 B145 00 5 11 B180 00 5 11 B250 00 5 11 B250 00 5 11 B310 00 5 11 B400 00 5 11 B500 00 5 11 B630 00 5 11 B630 00 5 – –
with DC contactor 11 BG06 1 D 3 11 BG06 1 D 3 11 BG06 1 D 3 11 BG06 1 D 3 11 BG09 1 D 3 11 BG09 1 D 3 11 BG12 1 D 3 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF12C 1 6 11 BF16C 1 6 11 BF20C 1 6 11 BF25C 1 6 11 BF32C 00 6 11 BF40C 00 6 11 BF50C 00 6 11 BF65C 00 6 11 BF80C 00 6 11 BF95C 00 6
contactor

Three-pole contactor with thermal overload relay


Backup fuse aM [A] 2 4 6 8 8 10 16 2 4 6 8 8 10 16 20 25 25 40 45 50 80 100 100 125 125 160 200 250 315 315 400 – – – – –
AC contactor ■ 11 BG06 1 A 2 11 BG06 1 A 2 11 BG06 1 A 2 11 BG06 1 A 2 11 BG09 1 A 2 11 BG09 1 A 2 11 BG12 1 A 2 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF9 1 4 11 BF12 1 4 11 BF16 1 4 11 BF20 00 4 11 BF25 00 4 11 BF32 00 4 11 BF40 00 4 11 BF50 00 4 11 BF65 00 4 11 BF80 00 4 11 BF95 00 4
11 B115 00 5 11 B115 00 5 11 B145 00 5 11 B180 00 5 11 B250 00 5 11 B250 00 5 11 B310 00 5 11 B400 00 5 11 B500 00 5 11 B630 00 5 11 B630 00 5 – –
DC contactor ■ 11 BG06 1 D 3 11 BG06 1 D 3 11 BG06 1 D 3 11 BG06 1 D 3 11 BG09 1 D 3 11 BG09 1 D 3 11 BG12 1 D 3 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF9C 1 6 11 BF12C 1 6 11 BF16C 1 6 11 BF20C 1 6 11 BF25C 1 6 11 BF32C 00 6 11 BF40C 00 6 11 BF50C 00 6 11 BF65C 00 6 11 BF80C 00 6 11 BF95C 00 6

Thermal overload relay manual reset 11 RF9 1V5 11 RF9 2V3 11 RF9 5 11 RF9 75 11 RF9 75 11 RF9 10 11 RF9 15 11 RF25 1V5 11 RF25 2V3 11 RF25 5 11 RF25 75 11 RF25 75 11 RF25 10 11 RF25 15 11 RF25 23 11 RF25 23 11 RF25 23 11 RF95 33 11 RF95 42 11 RF95 50 11 RF95 65 11 RF95 82 11 RF95 95 11 RF180 125 11 RF180 125 11 RF180 150 11 RF180 200 11 RF400 250 11 RF400 300 11 RF400 300 11 RF400 420 – – – – –
Set of relay-contactor links – – – – – – – – – – – – – – – – – 11 G260 11 G260 11 G261 11 G261 11 G261 11 G261 11 G372 11 G372 11 G372 11 G372 11 G376 11 G376 11 G376 11 G376 – – – – –
Relay adjustment range [A] ❖ 0.9 - 1.5 1.4 - 2.3 3-5 4.5 - 7.5 4.5 - 7.5 6 - 10 9 - 15 0.9 - 1.5 1.4 - 2.3 3-5 4.5 - 7.5 4.5 - 7.5 6 - 10 9 - 15 14 - 23 14 - 23 14 - 23 20 - 33 28 - 42 35 - 50 46 - 65 60 - 82 70 - 95 75 - 125 75 - 125 90 - 150 120 - 200 150 - 250 180 - 300 180 - 300 250 - 420 – – – – –

Assembled star-delta starter, open frame


Contactor
with thermal Backup fuse aM [A] – – – – – – – – – – 6 8 10 16 20 25 25 32 40 45 63 80 100 125 125 160 200 250 315 315 400 500 630 630 – –
relay
Assembled starter – – – – – – – – – – 21 DYF9 E5 4 21 DYF9 E5 4 21 DYF9 E75 4 21 DYF9 E75 4 21 DYF9 E10 4 21 DYF12 E15 4 21 DYF12 E15 4 21 DYF20 E23 4 21 DYF25 E23 4 21 DYF25 E26 4 21 DYF40 E42 4 21 DYF50 E50 4 21 DYF50 E50 4 21 DYF65 E65 4 21 DYF65 E65 4 21 DYF80 E82 4 21 NFY115 100 8 21 NFY115 125 8 21 NFY145 125 8 21 NFY180 200 8 21 NFY250 250 8 21 NFY250 300 8 21 NFY400 420 8 21 NFY400 420 8 – –

Star-delta starter components, to be customer assembled – –


Backup fuse aM [A] – – – – – – – – – – 6 8 10 16 20 25 25 32 40 45 63 80 100 125 125 160 200 250 315 315 400 500 630 630 – –
Line contactor ■ – – – – – – – – – – 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF12 10 4 11 BF12 10 4 11 BF20 00 4 11 BF25 00 4 11 BF25 00 4 11 BF40 00 4 11 BF50 00 4 11 BF50 00 4 11 BF65 00 4 11 BF65 00 4 11 BF80 00 4 11 B115 00 5 11 B115 00 5 11 B145 00 5 11 B180 00 5 11 B250 00 5 11 B250 00 5 11 B400 00 5 11 B400 00 5 – –
Delta contactor ■ – – – – – – – – – – 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF12 10 4 11 BF12 10 4 11 BF20 00 4 11 BF25 00 4 11 BF25 00 4 11 BF40 00 4 11 BF50 00 4 11 BF50 00 4 11 BF65 00 4 11 BF65 00 4 11 BF80 00 4 11 B115 00 5 11 B115 00 5 11 B145 00 5 11 B180 00 5 11 B250 00 5 11 B250 00 5 11 B400 00 5 11 B400 00 5 – –
Star contactor ■ – – – – – – – – – – 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF9 10 4 11 BF12 10 4 11 BF16 10 4 11 BF16 10 4 11 BF25 00 4 11 BF32 00 4 11 BF32 00 4 11 BF32 00 4 11 BF32 00 4 11 BF50 00 4 11 BF65 00 4 11 BF65 00 4 11 BF80 00 4 11 B115 00 5 11 B145 00 5 11 B145 00 5 11 B250 00 5 11 B250 00 5 – –
Thermal overload relay – – – – – – – – – – 11 RF25 5 11 RF25 5 11 RF25 75 11 RF25 75 11 RF25 10 11 RF25 15 11 RF25 15 11 RF25 23 11 RF25 23 11 RF25 26 11 RF95 42 11 RF95 50 11 RF95 50 11 RF95 65 11 RF95 65 11 RF95 82 11 RF180 100 11 RF180 125 11 RF180 150 11 RF180 200 11 RF400 250 11 RF400 300 11 RF400 420 11 RF400 420 – –
Set of relay-contactor links – – – – – – – – – – – – – – – – – – – – 11 G260 11 G261 11 G261 11 G261 11 G261 11 G261 11 G372 11 G372 11 G372 11 G372 11 G376 11 G376 11 G376 11 G376 – –
Time relay – – – – – – – – – – 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 31 BT2N 12S 7 – –
Add-on auxiliary contact block – – – – – – – – – – 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 4 - 11 G480 11 1 - 11 G480 11 1 - 11 G480 11 1 - 11 G480 11 3 - 11 G350 3 - 11 G350 3 - 11 G350 3 - 11 G350 3 - 11 G350 – –
Add-on auxiliary contact block – – – – – – – – – – – – – – – – – – – – – – – – – – 2 - 11 G350 2 - 11 G350 2 - 11 G350 – – – – – – –
Star-delta Rigid connector kit – – – – – – – – – – 11 SMX90 23 11 SMX90 23 11 SMX90 23 11 SMX90 23 11 SMX90 23 11 SMX90 23 11 SMX90 23 11 SMX90 25 11 SMX90 25 11 SMX90 25 11 SMX90 27 11 SMX90 29 11 SMX90 29 11 SMX90 29 11 SMX90 29 11 SMX90 20 – – – – – – – – – –
starter

Soft starters
Quick backup fuse (Brush) – – – – 35 FE 35 FE 35 FE 35 FE 35 FE 35 FE 35 FE 35 FE 35 FE 35 FE 45 FE 90 FE 90 FE 90 FE 120 FEE 120 FEE 160 FEE 180 FM 200 FM 250 FM 280 FM 315 FM 500 FMM 550 FMM 550 FMM 630 FMM 900 F4M 900 F4M 1100 F4M 1250 F4M – –
Soft-starter – – – – 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADXM 12B 51 ADX 0017B 51 ADX 0030B 51 ADX 0030B 51 ADX 0030B 51 ADX 0045B 51 ADX 0045B 51 ADX 0060B 51 ADX 0075B 51 ADX 0085B 51 ADX 0110B 51 ADX 0125B 51 ADX 0142B 51 ADX 0190B 51 ADX 0245B 51 ADX 0245B 51 ADX 0310 51 ADX 0365 51 ADX 0470 51 ADX 0568 51 ADX 0640 51 ADX 0820 51 ADX 1200
By-pass contactor – – – – incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated incorporated B250 B310 B400 B500 B500 B630 1000 B1250

➊ Replace with: 10 to obtain contactor with one normally open auxiliary contact ➎ The electromagnet of the contactor can be powered indifferently in AC or DC. ■ Rated current Rated current Rated current ▲ RANGES AVAILABLE Breaking capacity Potere d’interruzione ❖ RANGES AVAILABLE For contactors
(NO) or 01 to obtain contactor with one normally closed auxiliary contact (NC). Complete the order code only with the digit of the coil voltage. For coils: Type at 400V Type at 400V Type at 400V FOR MOTOR PROTECTION Icu at 400V - 100kA for 0.1-10A,
Breaking capacity
Icu a 400V = 100kA (0,1÷10A), 25kA (9÷25A) FOR THERMAL For mini-contactors For contactors
BF20, BF25, BF32, BF40, BF50, BF65,
For contactors Other types:
Icu at 400V - 50kA BG06, BG09 and BG12 BF9, BF12, BF16, BF20, BF25, BF32 and BF40 B115, B145, B180, B250, B310 and B400
➋ Complete order code with the coil voltage digit or with the voltage digit fol- 110/125V indicate 110, 220/240V indicate 220, 380/415V indicate 380, A (AC1 ≤40°C) A (AC3 ≤55°C) A (AC1 ≤40°C) A (AC3 ≤55°C) A (AC1 ≤40°C) A (AC3 ≤55°C) CIRCUIT BREAKERS 25kA for 9-25kA per montaggio in centralini modulari OVERLOAD RELAYS BF80 and BF95
lowed by 60 if 60Hz. The standard voltages are as follows: 440/480V indicate 440. Standard voltages are: 24-48-60-110/125-220/240- 11 BG06 16 6 11 BF90 25 9 11 B115 160 110 11 SM1B 00 0.1-0.16A 11 SM2A 64 22-32A 11 SM1C 00 0,1÷0,16 11 RF9 015 0.09-0.15A 11 RF25 015 0.09-0.15A 11 RF95 23 14-23A 11 RF180 100 60-100A
380/415-440/480V (24V voltage is not possible for B500-B630 1000).
-- 50/60Hz 024-048-110-220-220/230-230-240-380-400-415V
-- 60Hz 024-048-110-120-220-230V. Other voltages available on request.
11 BG09 20 9 11 BF12 25 12 11 B145 250 150 The recommended 11 SM1B 04 0.16-0.25A 11 SM2A 68 28-40A 11 SM1C 04 0,16÷0,25 The recommended 11 RF9 023 0.14-0.23A 11 RF25 023 0.14-0.23A 11 RF95 33 20-33A 11 RF180 125 75-125A Control relays
11 BG12 20 12 11 BF16 25 16 11 B180 275 185 range is indicated 11 SM1B 08 0.25-0.4A 11 SM2A 72 36-45A 11 SM1C 08 0,25÷0,4 range is indicated 11 RF9 033 0.2-0.33A 11 RF25 033 0.2-0.33A 11 RF95 42 28-42A 11 RF180 150 90-150A
➏ Complete the order code with the digit of the coil voltage. Standard voltages
➌ Complete order code with coil voltage digit. Standards voltages are: 012-024- 11 BF20 40 20 11 B250 350 265 in the table above. 11 SM1B 12 0.4-0.63A 11 SM2A 76 40-50A 11 SM1C 12 0,4÷0,63 in the table above. 11 RF9 05 0.3-0.5A 11 RF25 05 0.3-0.5A 11 RF95 50 35-50A 11 RF180 200 120-200A
048-060-110-125-220V. are: 12-24-48-60-110-125-220VDC.
The following are The following are
Soft ➍ Complete order code with the coil voltage digit (if 50Hz) or with the ➐ Complete the order code with the digit of the coil voltage:
11 BF25 40 25 11 B310 450 320
other available types:
11 SM1B 16 0.63-1A 11 SM1C 16 0,63÷1
other available types:
11 RF9 075 0.45-0.75A 11 RF25 075 0.45-0.75A 11 RF95 65 46-65A Four-pole contactors
48 (24/48VAC/DC) - 110 (24VAC/DC - 110-125VAC) 11 BF32 55 32 11 B400 550 420 11 SM1B 20 1-1.6A 11 SM1C 20 1÷1,6 11 RF9 1 0.6-1A 11 RF25 1 0.6-1A 11 RF95 82 60-82A 11 RF400 250 150-250A
starter voltage digit followed by 50-60 (if 50/60Hz frequency) or with the voltage
220 (24VAC/DC - 220-240VAC) - 380 (24VAC/DC - 380-415VAC) 11 BF40 60 40 11 B500 700 520 11 SM1B 24 1.6-2.5A 11 SM1C 24 1,6÷2,5 11 RF9 1V5 0.9-1.5A 11 RF25 1V5 0.9-1.5A 11 RF95 95 70-95A 11 RF400 300 180-300A
digit followed by 60 (if 60Hz).
The standard voltages are as follows: 440V (24VAC/DC - 415-440VAC). 11 BF50 90 50 11 B630 800 630 11 SM1B 28 2.5-4A 11 SM1C 28 2,5÷4 11 RF9 2V3 1.4-2.3A 11 RF25 2V3 1,4-2.3A 11 RF400 420 250-420A Special contactors for power factor correction
-- 50Hz 24-48-110-220-230-240-380-400-415V ➑ Complete order code with the coil voltage digit (if 50Hz) or with the 11 BF65 110 65 11 B630 1000 1000 – Breaking capacity 11 SM1B 32 4-6.5A Breaking capacity 11 SM1C 32 4÷6,5 11 RF9 33 2-3.3A 11 RF25 33 2-3.3A
-- 50/60Hz 24-48-110-220-220/230-230-240-380-380/400-415V voltage digit followed by 60 (if 60Hz). Icu at 400V - 50kA Icu at 400V - 50kA
11 BF80 125 80 11 B1250 1250 – 11 SM1B 36 6.3-10A 11 SM1C 36 6,3÷10 11 RF9 5 3-5A 11 RF25 5 3-5A
-- 60Hz 24-48-110-120-220-230V. The standard voltages are as follows:
– 50Hz 24-48-110-220-230-240-380-400-415VAC
11 BF95 125 95 11 B1600 1600 – 11 SM1A 40 9-14A 11 SM1B 40 9-14A 11 SM3A 84 45-63A 11 SM1C 40 9÷14 11 RF9 75 4.5-7.5A 11 RF25 75 4.5-7.5A Special 4NC power pole contactor
– 60Hz 24-48-110-120-220-230VAC. 11 SM1A 44 13-18A 11 SM1B 44 13-18A 11 SM3A 88 57-75A 11 SM1C 44 13÷18 11 RF9 10 6-10A 11 RF25 10 6-10A
11 SM1A 48 17-23A 11 SM1B 48 17-23A 11 SM3A 92 70-90A 11 SM1C 48 17÷23 11 RF9 15 9-15A 11 RF25 15 9-15A
11 SM1A 52 20-25A 11 SM1B 52 20-25A 11 SM3A 96 80-100A 11 SM1C 52 20÷25 11 RF25 23 14-23A
Special 2NO+2NC power pole contactors
11 RF25 26 17-26A
Motor protection circuit breakers Add-on blocks and accessories Contactors Add-on blocks and accessories Thermal overload relays Electromechanical starters
electric
for SM1 types for SM2 and SM3 types for mini-contactors BG for contactors BF for contactors B for relays RF Starter assembly accessories

Order code Characteristics Q.ty Wt Order code Characteristics Q.ty Wt Order code Characteristics Q.ty Wt Order code Characteristics Max Q.ty Wt Order code Characteristics Max Q.ty Wt Order code Characteristics Max Q.ty Wt Order code Characteristics Q.ty Wt Order code Characteristics Max Q.ty Wt Order code Characteristics Q.ty Wt Order code Characteristics Q.ty Wt
per [kg] per [kg] per [kg] qty per per [kg] qty per per [kg] qty per per [kg] per [kg] qty per per [kg] per [kg] per [kg]
pkg pkg pkg contactor pkg contactor pkg contactor pkg pkg contactor pkg pkg pkg
ADD-ON AUXILIARY CONTACTS. PADLOCKABLE ATTACHMENT FOR OPERATING LEVER. ADD-ON AUXILIARY CONTACTS. AUXILIARY CONTACTS WITH SCREW TERMINALS. INSTANTANEOUS AUXILIARY CONTACTS MECHANICAL LATCH. POWER TERMINAL SHROUD. INSTANTANEOUS AUXILIARY CONTACTS. SET OF LINKS FOR DIRECT CONTACTOR MOUNTING 11 SMX90 01 Set of 3 connecting cables 10 0.012 to
TES
T
SMX90 10
SMX90 10 TES
T

SM1...
to
LL
ova
SM1...
WITH FRONT CENTRE MOUNTING➊. cables for SM1 breaker with
ova
LL

11 SMX11 20 Front mount 2NO 10 0.010 11 SMX18 10 3 padlocks max Ø 5mm 10 0.021 11 SMX20 11 Front mount 10 0.016 11 BGX10 20 2NO 1 10 0.021 11 G222 ➊ for CF4, BF9-BF40 1 1 0.059 11 G265➊ IP20 protection 10 0.011 11 G350➊ 2NO+1NC or 4 1 0.067 11 G430 ➊ RF...95 on BF20-BF25 10 0.027
1 changeover 11 G480 11 1NO + 1NC 2 10 0.024 (BF40 three-pole only) NO+2NC reversible contactor BG, BF9, BF12 or BF16
11 SMX11 11 Front mount 1NO+1NC 10 0.010 ADJUSTER SEALING KIT. 11 BGX10 11 1NO + 1NC 1 10 0.021 PARALLEL BRIDGES. 11 G291 ➋ BF20 40-BF25 40 10 0.021 contactor
11 SMX12 11 Side mount 1NO+1NC 10 0.045 11 SMX18 12 –– 10 0.003 11 SMX21 11 Front mount 10 0.018 11 BGX10 02 2NC 1 10 0.021 11 G480 20 2NO 2 10 0.024 11 G272 ➊ BF40 40, BF50-BF95 1 1 0.059 11 BA135 2 poles (for BF9-BF16) 10 0.001 11 G354➊ 1NO+1NC 4 1 0.065 11 G260 BF32-BF40 10 0.026 SMX90 01
1NO+1NC 11 SMX90 02 Set of 3 connecting cables 10 0.025 SMX90 02
SMX90 01

11 SMX12 20 Side mount 2NO 10 0.045 SM1-CONTACTOR CONNECTION. 11 BGX10 40 4NO 1 10 0.028 11 G480 1001 make before break ➋ 2 10 0.024 MECHANICAL INTERLOCKS. 11 BA235 2 poles (for BF20-BF40) 10 0.003 CONTACT BLOCK ADAPTER 11 G261 BF50÷BF95 10 0.048 for SM1 breaker with BF20,
SMX90
SMX90 03
03 SMX90 02

11 SMX22 11 Side mount 1 0.046 11 G484 20➌ 2NO 1 5 0.035 11 G223 per CF4, BF9-BF40 1 10 0.005 11 G358 To fit auxiliary contacts 4 5 0.035 BF25, BF32 or BF40 contactor
11 SMX12 02 Side mount 2NC 10 0.045 11 SMX90 01 For BG - BF9... to BF16 10 0.012 1NO+1NC 11 BGX10 31 3NO + 1NC 1 10 0.028 11 BA435 3 poles (for BF50-BF95) 10 0.029 11 G372 RF...180 on B115-B145-B180 1 0.082
(set of 3 cables) 11 G484 11➌ 1NO + 1NC 1 5 0.035 11 G269 1 (BF40 three-pole only) 1 10 0.023 G480, G484, G485, contactor 11 SMX90 03 Rigid connecting kit for SM1 10 0.020
11 SMX13 11 Side mount indicator 10 0.045 11 SMX22 20 Side mount 2NO 1 0.046 11 BGX10 22 2NO + 2NC 1 10 0.028 ENLARGED TERMINALS. G486 and G487 types, 11 G373 B250-B310-B400 1 0.100
contacts 1NO+1NC 11 SMX90 02 For BF20 to BF40 10 0.025 11 G484 02➌ 2NC 1 5 0.035 11 G269 2 BF40 40, BF50-BF95 1 10 0.028 breaker with BG
11 SMX22 02 Side mount 2NC 1 0.046 11 BGX10 13 1NO + 3NC 1 10 0.028 11 G231 1-6 mm2 (for BF9-BF16) 12 0.008 on B115-B630 1000 11 G375 RF...400 on B145-B180 1 0.103
(set of 3 cables) mini-contactor
UNDERVOLTAGE TRIP RELEASES. 11 BGX10 04 4NC 1 10 0.028 11 G484 30➌ 3NO 1 5 0.039 NOISE FILTERS (FASTON TERMINALS). 11 G232 1-10 mm2 (for BF20-BF25) 12 0.017 contactors 11 G376 contactor B250-B310-B400 1 0.165
11 SMX90 03 For BG 10 0.020 11 SMX23 11 Side mount indicator 1 0.092 11 SMX90 04 Rigid connecting kit for SM1 10 0.030
11 SMX14 BC 110VAC 50/60Hz 10 0.100 contacts (1NO+1NC) MECHANICAL INTERLOCK. 11 G484 21➌ 2NO + 1NC 1 5 0.039 11 G318 48 ≤48VAC/DC (Varistor) 10 0.008 11 G281 1-35 mm2 (for BF32-BF40) 10 0.090 MECHANICAL INTERLOCK. PROTECTION SHROUDS FOR POWER TERMINALS.
(rigid connecting kit) with BF9-BF16 connection
11 SMX14 CL 230VAC 50/60Hz 10 0.100 for thermal trip 11 BGX50 00 –– 1 10 0.008 11 G484 12➌ 1NO + 2NC 1 5 0.039 11 G318 125 48-125VAC/DC (Varistor) 10 0.008 11 G271 1-50 mm2 (for BF50-BF95) 10 0.130 11 G355➋➌ Side by side 1 1 0.025 11 G258 ➌ RF95 c/w G260 links 10 0.003
11 SMX90 04 For BF9 to BF16 10 0.030 11 SMX90 10 Adapter plate for 1 0.052 Combinations
11 SMX14 EA 400VAC 50/60Hz 10 0.100 and (1NO+1NC) 11 G484 03➌ 3NC 1 5 0.039 11 G318 240 125-240VAC/DC (Varistor) 10 0.008 11 G356 1➋ One on top of other 1 1 0.104 direct-on-line starter
(rigid connecting kit) QUICK CONNECT NOISE FILTER. AUXILIARY TERMINAL. 11 G262 ➌ RF95 c/w G261 links 10 0.004 Connections for reversing contactor Connections for reversing contactor
for magnetic trip composed by SM1 assembly with BG contactors assembly with BF9-BF16 contactors
11 SMX15 CL 230VAC 50/60Hz 5 0.100 SURFACE MOUNT ENCLOSURES. 11 BGX77 048 ≤48VAC/DC 1 10 0.007 INSTANTANEOUS AUXILIARY CONTACTS 11 G318 415 240-415VAC/DC (Varistor) 10 0.008 11 G285 for BF50-BF95 8 0.008 11 G356 2➋ One on top of other 1 1 0.110 11 G361 RF...180 1 0.026
with early-make contacts UNDERVOLTAGE TRIP RELEASES. WITH FRONT LATERAL MOUNTING. breaker and BG or
11 SMX17 10 IP40. 100mm wide 10 0.295 (Varistor) 11 G319 225 ≤225VDC (Diode) 10 0.008 MARKING ELEMENTS. 11 G356 3➋ One on top of other 1 1 0.116 11 G363 RF...400 1 0.046
11 SMX15 EA 400VAC 50/60Hz 5 0.100 11 SMX24 BC 110VAC 50/60Hz 1 0.135 11 G218➍ 1NO or 1NC revers. 2 10 0.011 BF9-BF40 contactor
11 SMX17 11 IP40. 85mm wide 10 0.250 11 BGX77 125 48-125VAC/DC 1 10 0.007 11 G322 48 ≤48VAC (Resistor-Condenser) 10 0.008 11 BA126 1 Label for alphanumeric symbols 100 0.001 11 G356 4➋ One on top of other 1 1 0.122 INDEPENDENT MOUNTING.
with early-make contacts 11 SMX24 CL 230VAC 50/60Hz 1 0.135 (Varistor) 11 G418 10 1NO 2 10 0.014 11 SMX90 12 Adapter plate for reversing 1 0.078
FLUSH MOUNT ENCLOSURE. 11 G322 220 48-240VAC (Resistor-Condens.) 10 0.008 11 BA126 2 Label for writing 100 0.001 11 G356 5➋ One on top of other 1 1 0.124 SCREW FIXING OR 35mm DIN RAIL (EN 50022) MOUNTING. contactor assembly composed
SHUNT TRIP RELEASES. 11 SMX24 EA 400VAC 50/60Hz 1 0.135 11 BGX77 240 125-240VAC/DC 1 10 0.007 11 G418 10A 1EM 2 10 0.014
11 SMX17 20 IP40. 100mm wide 10 0.230 11 G322 380 240-415VAC (Resistor-Condens.) 10 0.008 3958➋ Alphanumeric symbols 100 0.002 11 G356 6➍ One on top of other 1 1 0.134 11 G230 RF25 10 0.042 by SM1 breaker and
11 SMX16 AF 24VAC 50/60Hz 5 0.100 11 SMX25 CL 230VAC (50/60Hz) 1 0.135 (Varistor) 11 G418 01 1NC 2 10 0.014 BG or BF9-BF25 contactors
ACCESSORIES FOR ENCLOSURES. FILTER SUPPORT. MECHANICAL LATCH. 11 G270 RF95 10 0.094
11 SMX16 BC 110VAC 50/60Hz 5 0.100 with early-make contacts 11 BGX78 225 ≤225VDC 1 10 0.007 11 G418 01D 1LB 2 10 0.014
➊ For 3-pole contactors, BF50-BF95 types only.
11 SMX90 14 Adapter plate for star-delta 1 0.104 BGX50
BGX50 00❶00 G223
G223
PADLOCKABLE ROTARY ACTUATOR. (Diode) 11 RE244 For 35 mm DIN rail (EN 50022) 10 0.004 N.B. Two pieces are required per contactor. 11 G495➎➏➐ For B115-B630 1 1 0.716 ELECTRICAL RESET.
11 SMX16 CL 230VAC 50/60Hz 5 0.100 11 SMX25 EA 400VAC (50/60Hz) 1 0.135 starter composed by SM1
11 SMX17 30 ➋ IP65. For SMX17 10 and 10 0.400 11 G481 20➍ 2NO 2 10 0.013 QUICK CONNECT NOISE FILTERS ➋. POWER TERMINAL PROTECTION. 11 G228➍ All types 5 0.058
with early-make contacts 11 BGX79 048 ≤48VAC 1 10 0.007 ➋ Replace with the required alphanumeric symbol breaker and 45mm wide
11 SMX16 EA 400VAC 50/60Hz 5 0.100 11 G481 11➍ 1NO + 1NC 2 10 0.013
SMX17 20 enclosures SHUNT TRIP RELEASES. (Resistor-Condenser) 11 G477 048 ≤48VAC (Varistor) 10 0.010 11 G360➑ For contactor B115 1 0.026 SEALING DEVICE. contactors (BF9-BF25) SMX90
SMX90 22 22
THREE-PHASE CONNECTION BUSBARS 45MM SPACING. 11 SMX17 35 ➋ IP65. Red-yellow colour. 10 0.110 11 G481 02➍ 2NC 2 10 0.013 G269
G269 1 1

11 SMX26 AF 24VAC 50/60Hz 1 0.135 11 BGX79 125 48-125VAC 1 10 0.007 11 G477 125 48-125VAC (Varistor) 10 0.010 11 G361➑ For contactors B145-B180 1 0.026 11 G233 All types 1 0.002 11 SMX90 18 35mm DIN rail (EN 50022) 1 0.088
11 SMX90 32

11 SMX90 33
For 2 breakers without
side-mount contacts
For 3 breakers without
side-mount contacts
10

10
0.027

0.048
For SMX17 10 and
SMX17 20 enclosures
ACTUATOR WITH EMERGENCY STOP BUTTON.
11 SMX26 BC
11 SMX26 CL
110VAC 50/60Hz
230VAC 50/60Hz
1
1
0.135
0.135 11 BGX79 240
(Resistor-Condenser)
125-240VAC
(Resistor-Condenser)
1 10 0.007
11 G482➌➍

11 G280
Changeover contact
SUPPORT FOR AUXILIARY CONTACT SIDE MOUNTING.
for G218
2

2
10

10
0.013

0.008
11 G477 240
11 G477 415
11 G479 48
125-240VAC (Varistor)
240-415VAC (Varistor)
≤48VAC (Resistor-Condenser)
10
10
10
0.010
0.010
0.010
11 G363➑
11 G527
11 G528
For contactors B250-B310-B400 1
For contactor B500
For contactor B500 4
1
1
0.047
0.238
0.265
ELECTRIC BUTTON NO.
11 G244
MARKING ELEMENT.
All types 10 0.011
11 SMX90 19
for cable bypass of contactor
used with SMX90 14 plate
35mm DIN rail extension for 1 0.004
SMX90
SMX90 2424

Motor protection
and control
11 SMX17 40 ➋ IP65. For SMX17 11 enclosure 10 0.100 11 SMX26 EA 400VAC 50/60Hz 1 0.135 55mm wide contactors
11 BGX79 415 240-415VAC 1 10 0.007 11 G483 for G481 and G482 2 10 0.010
11 SMX90 34 For 4 breakers without 10 0.068 PADLOCKABLE DOOR INTERLOCK ROTARY ACTUATOR. 11 G479 125 48-125VAC (Resistor-Condens.) 10 0.010 11 G529 For contactor B630 1 0.250 11 RB6 All types 100 0.001
NEUTRAL CONNECTION. (Resistor-Condenser) 11 SMX90 20 Connecting kit for star-delta 1 – Adapter plate for star-delta starter with Connections for star-delta
side-mount contacts DELAYED AUXILIARY CONTACTS 1NO + 1NC 11 G479 240 125-240VAC (Resistor-Condens.) 10 0.010 11 G530 For contactor B630 4 1 0.290 ALPHANUMERIC SYMBOLS. SM1 breaker and BF9-BF25 contactors starters with BF9-BF16
11 SMX17 50 For SMX17 10 and SMX17 20 10 0.020 11 SMX28 10 IP65. 3 padlocks max 1 0.100 PARALLEL BRIDGES starter composed by
11 SMX90 35 For 5 breakers without 10 0.090 (PNEUMATIC OPERATION) ON ENERGISATION➊. contactors
11 G479 415 240-415VAC (Resistor-Condens.) 10 0.010 3 POLE STAR CONNECTING BARS. 3958❺ All types 100 0.002 BF50-BF95 (line-delta contactors)
side-mount contacts PILOT LIGHT. 11 G323 2 poles 10 0.009 11 G485 3 3s 1 1 0.040 and BF50-BF95 (star contactor)
➊ Only for contactors B115-B145-B180-B250-B310-B400- SMX90
SMX90 14
23 NEONV➊V Green 10 0.006 11 G324➊ 2 poles 10 0.009 ➊ Replace with the digit of the voltage (if 50 or 60Hz) and with 11 BA1595 For B115-B145-B180 1 0.082 ➊ G430 can be used only for connection between RF...95 and 14

THREE-PHASE CONNECTION BUSBARS 54MM SPACING. 11 G485 6 6s 1 1 0.040 B500-B630-B630 1000. 11 SMX90 21 Connection kit for wye-delta 1 14.00
the letter C followed by the digit of the voltage (if DC). 11 BA1721 For B250-B310-B400 1 0.140 BF20 00, BF25 00.
11 SMX90 42 For 2 breakers complete with 10 0.034 23 NEONR➊V Red 10 0.006 11 G325 4 poles 10 0.014 11 G485 15 15 s 1 5 0.040 starter with BG mini-contactors
Standard voltages are: ➋ Not suitable for B630 1000, B1250, B1600. ➋ G291 can be used only for connection between RF...95 and
side-mount contacts IP65 MEMBRANE COMPLETE WITH RIM. 11 G326➊ 4 poles 10 0.014 11 BA1846 For B500-B630 1 0.340 TES
T

11 G485 30 30 s 1 5 0.040 50/60Hz 24V - 48V - 110/125V - 220/240V - 380/415V ➌ For use with three-pole B630 1000, contact our Customer BF20 40, BF25 40, BF25C 40, BF20C 10, BF20C 01, BF25C 10, 11 SMX90 22 Rigid connecting kit for 1 0.026 LL
ovat
o

11 SMX90 43 For 3 breakers complete with 10 0.054 11 SMX17 45 For SMX17 11 enclosure 10 0.010 DC 12V - 24V - 48V - 110/125V - 220/240V 2 POLE BARS FOR PARALLEL ARRANGEMENT. reversing contactor assembly SMX90 19
➊ Complete order code with the required alphanumeric symbol. 11 G485 60 60 s 1 5 0.040 Service (Tel. +39 035 4282422). BF25C 01. B115
SMX90 19
11 BA1594 For B115-B145-B180 1 0.089 B145 composed by mini-contactors
side-mount contacts ➊ Complete with required voltage. ➋ The G477 and G479 filters can only be fitted on BF9-BF25 and ➍ To interlock two contactors B1250 or B1600, it is imperative to ➌ Front IP20 protection is warranted to contactor-thermal relay B180
11 G485 120 120 s 1 1 0.040 B250 BG ➊➋
11 SMX90 44 For 4 breakers complete with 10 0.078 Available voltages: 24-110-220-380VAC. CF4 contactors having 3-terminal coil. use two pieces of type G356 6, one fixed on the left side and 11 BA1720 For B250-B310-B400 1 0.140 connections.
DELAYED AUXILIARY CONTACTS 1NO + 1NC B310 SMX90
SMX9001
01

side-mount contacts the other on the right. 11 BA1845 For B500-B630 1 0.320 ➍ Replace with voltage digit. B400 11 SMX90 23 Rigid connecting kit for 1 0.050 SMX90
SMX9002
02

➋ The device obtained with this actuator is not (PNEUMATIC OPERATION) ON DE-ENERGISATION➊. star-delta starter composed by SMX90
SMX90 2323
➎ Replace with the digit of the voltage (if 50 or 60 Hz) or with the Standard voltages are: 24V - 48V - 110/125V - 220/240V - SMX90
SMX90 18
18
11 SMX90 45 For 5 breakers complete with 10 0.103 suitable for isolation per IEC/EN 60947-2 standars. TERMINAL ADAPTER.
11 G486 3 3s 1 1 0.040 letter C followed by voltage (if DC). The standard voltages are: 380/415V (50/60Hz). BF9, BF12 or BF16 contactors
side-mount contacts
11 G486 6 6s 1 1 0.040 – 50/60 Hz 11 G370 To transform Faston terminals 10 0.003 (suitable for contactors
TERMINAL BLOCK FOR BUSBAR SUPPLY. ➎ Replace with the required alphanumeric symbol.
G480...
48V - 110/125V - 220/240V - 380/415V - 440/480V of auxiliary contacts and coils mounted side by side; not
11 G486 15 15 s 1 5 0.040 into screw terminals suitable for SMX90 14 plate)
11 SMX90 30 –– 10 0.033 – DC
11 G486 30 30 s 1 5 0.040 11 G371 To transform both 5 0.012 11 SMX90 24 Rigid connecting kit for 1 0.047
SAFETY COVER. G484... 48V - 110/125V - 220/240V - 380/415V - 440/480V
11 G486 60 60 s 1 5 0.040 ➏ It can be mounted only in contactors if predisposed for it. coil Faston terminals reversing contactor assmbly
11 SMX90 31 For unused 10 0.005
busbar terminals 11 G486 120 120 s 1 1 0.040 into screw terminals Mounting position composed by BF9, BF12 or
➐ Except for B310 and B310 4.
MARKING ELEMENTS. BF16 contactors➊➋
PADLOCKABLE DOOR INTERLOCK HANDLE. 11 G487 70 ms 1 1 0.040 ➑ Provided for one pole terminal only. Example: For three-pole
G485... 11 SMX90 25 Connecting kit for star-delta 1 –
11 SMX18 14 Red/yellow colour. 1 0.600 G486... contactors, purchase 3 pieces for the upper terminals only or 6 11 BA126 1 Label for alphanumeric symbols 100 0.001 BF32
➊ The contacts can also be fitted on B type contactors using BF32
BF40 BF50 starter composed by
G487... pieces for all upper and lower terminals. BF40 BF50
BF65
3 padlocks max the adapter G358. 11 BA126 2 Label for writing 100 0.001 BF65
BF80
BF80 BF20-BF25 (line-delta contactors)
➋ The normally closed contact is late breaking. G272 ➒ Replace with the required alphanumeric symbol. 3958 ➒ Alphanumeric symbols 100 0.002
BF95
BF95
11 SMX18 15 Black colour. 3 padlocks max 1 0.600 BF20
BF20
and BF9-BF16 (star contactor)
➌ High conductivity contacts.
➍ With Faston terminals.
BF9
BF12
BF9
BF25
BF25
11 SMX90 26 Rigid connecting kit for two
BF20 or BF25 contactors➊➋
1 16.00 Soft starters
Mounting position Rigid connecting kit for SM1 Adapter plate and connections for BF12
BF16
BF16 G372 5

G261
L3

G261 G372
breaker with BG contactor SM1 breaker with BG or BF9 to G373
G373 11 SMX90 27 Connecting kit for star-delta 1 –
Remote keypad and control software
3
L2

BF40 contactor Mounting position G375


G375

G269 2
G376
G376 1 starter composed by
SMX24... G222 G262
L1

SMX24...
SMX25... G527
G527 (B500
(B500 00)
00) G258
G258
G262
BF32-BF40 (line-delta contactors)

5
SMX25...
Mounting position Mounting position G528 (B5004 00)

3
SMX26... G528 (B500 4 00)
and BF20-BF25 (star contactor)

1
SMX26...
G529 (B630 00)
G529 (B63000) G260
G260
G270
G530 (B630 4 00)
G530 (B630 4 00)
G270
RF180
RF180 Order code Characteristics Q.ty Wt
G318... RF400
RF400
11 SMX90 28 Rigid connecting kit for two 1 20.00 per [kg]
SMX12...
SMX12...
Mounting position G319... BF32 or BF40 contactors➊➋ pkg
BG06...
ST

ova
to
TE
T SMX90
SMX9010
10 T G322... G271 BG06...
SMX13...
LL

G430 11 SMX90 29 Connecting kit for star-delta 1 –


TES
SMX13... to

SM1...
TES
G265 BG09...
BG09... G430
51 ADX TAST Remote keypad 1 0.350
to
LL
ova
SM1... LL
ova

G481... BG12...
BG12...
G291
G291 G233
G233

G482... BA435 starter composed by 96x96mm,


G326
G218 BF50-BF95 (line-delta contactors) 2x16 backlit LCD,
to

G325 G356...
G356...
and BF32-BF40 (star contactor)
ova
LL

SMX90 01 G370
G370 208-240VAC
SMX11...
SMX11... 2 SMX90 02
SMX90 01
SMX23
SMX23 1111
G285
SMX90 03 SMX90 02 G324 supply c/w 3m long
SMX15... 1 ➊ ➊ Contactors with one NC auxiliary contact, 01
SMX90 03
SMX15... G418... G483 G281 G244
G244

G323 G371 G362 (B250)


G363 (B250-310-400) RF95 type, are usually used. connecting cable
SMX16... 1 ➊
SMX16... G371 G363 (B310-B400) RF95

SMX22...
SMX22...
➋ The relay can not be directly mounted on the 31 PA 96X96 Protective cover 1 0.077
SMX20
SMX20 11 11 G280 G230
G230
SMX14... 1 ➊
SMX14...
SMX21 11
SMX21 11 G228
G228
contator. Use the RF25 type and the G230 (IP54)
BG00... G355
G355
independent mounting base. 51 ADX SW PC-ADX remote control 1 0.550
BG06...
BA235 G350
G350
➊ Only one add-on block can be fixed on the left side of the breaker.
BG09... G269 1 G354
G354 RF25
RF25 3958... software complete with
BG12...
a set of connecting
BGX77... G232 RF9
RF9
RB6 cables for
BGX78 225 G360 (B115)
G360 (B115) communications via
BGX79... G231 G361 (B145-B180)
G361 (B145-180)
RS-232 port, modem
G480...
BGX10 40 BF50 or GSM modem
BGX10 31 BF65 ➊ For BF20 40 - BF25 40 and DC types.
BGX10 22 G223 BF80
BGX10 13
BGX10 04
BA135
BF95 BA1846
BA1846
G484... Planet-SWITCH
Planet-SWITCH
(B500-B630)
(B500-B630)

BGX10 10
BGX10 11
BGX10 02
G477...
G479...
BF32
BF40❶ G485... - G486... - G487... Planet-DIN
Planet-DIN
BGX77...
BGX78 225 G371 LOVATO ELECTRIC S.P. A.
BGX79...
BF20
B500
B500
B630
B630
B630 1000
CONTROL SOLUTIONS
Planet-LOGIC
Planet-LOGIC
BA126 2
BF25
B630 1000 BA1845
BA1845
(B500-B630)
(B500-B630) FOR INDUSTRY www.LovatoElectric.com
BGX50 00
BGX10 40
BGX10 31
BA126 1
CF4
➊ Side-mount auxiliary
contacts can not be fitted VIA DON E. MAZZA, 12 International Sales Department: 100% electricity
BGX10 22 BF9 on BF40 22 contactors 24020 GORLE (BG) Tel. +39 035 4282281
BGX10 13
BGX10 04 3958...
BF12
BF16
BA1720
BA1720 100% electricity ITALY Fax +39 035 4282400
B250
B250
B310
BGX77... B310
BGX10 40 B400 BA1721
BA1721
Tel.: +39 035 4282111

PD31 GB 07 02
BGX10 31 BGX78 225 BGX10 20 B400
BGX10 22 BGX79... BGX10 11
BGX10 02
G358 Fax: +39 035 4282200
BGX10 13 BA1595
BA1595 BA1594
BA1594
BGX10 04 BGX10 20
B115
B115
B145
B145
BA126
BA126 2 2 E-mail info@lovatoelectric.com
B180
BGX10 11 B180 BA126
BA126 11
BGX10 02 G480...
3958
3958