DATE PLOTTED: 14 September 2023 6:18 PM BY : BECKMANS, TIM

INTERSECTION IN-07 LIMIT OF WORKS


APPROX. 60 m WEST, REFER DRG.
304200666-0305 FOR DETAILS

20.0
RD-02 (LECKY ROAD)
35.0
RD-02 (LECKY ROAD)
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

TAPER STORAGE

2.0

3.5 3.5 3.5

3.5 3.5
3.5 3.5

3.5 3.5

3.5
2.0
5.6

5.0

2.0
5.0

3.5
3.0
35.0 20.0

STORAGE
STORAGE TAPER

30.0
1.5

1.5

TAPER
15.0

CONNECTOR ROAD
3.5

RD-02
3.5 REFER DRG. 304200666-0306
FOR DETAILS

1\PS602663

LIMIT OF WORKS
LIMIT OF WORKS

GENERAL NOTES: KEY


1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.

IN-07
PROPOSED RESERVE BOUNDARY
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE
EXISTING TITLE BOUNDARY
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED.
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND
SERVICES SHOULD BE VERIFIED ON SITE. ULTIMATE DESIGN

3. INTERSECTION - IN-07
VPA BASE
4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 15

5. INTERSECTION TYPE - SECONDARY ARTERIAL / CONNECTOR ROAD

6. DECLARED MAIN ROAD - RD-02 (LECKY ROAD) - SPEED ZONE 60 KM/H - DESIGN SPEED 60 KM/H
LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H WARNING
PLAN - INTERSECTION IN-07 0 10 20 30 40 50m BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE
7. DESIGN VEHICLE - 26m B-DOUBLE
SCALE: 1:500
APPROXIMATE ONLY AND THEIR EXACT POSITION
SCALE 1:500 @A1 SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


G.STENTON 02-06-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project
CAD File: 304200666-0541.dwg

Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 42 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-07 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY 304200666-0541 P3
DATE PLOTTED: 14 September 2023 6:18 PM BY : BECKMANS, TIM

LIMIT OF WORKS

G (EX)
G (EX)

TAPER
CONNECTOR ROAD

15.0
G (EX)
3.5

G (EX)
CULVERT CROSSING CU-02 (REFER DRG.
304200666 -1050 FOR FURTHER DETAILS) CONNECT TO MELBOURNE WATER DRAINAGE TO BE COMPLETED
1.5 BY MELBOURNE WATER (NOT PART OF DEVELOPER
CONTRIBUTIONS PLAN)

G (EX)
CONNECT TO MELBOURNE WATER DRAINAGE. TO BE COMPLETED BY
3.0
MELBOURNE WATER (NOT PART OF DEVELOPER CONTRIBUTIONS PLAN)
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

TAPER
15.0
G (EX)
1.5

STORAGE
3.5 3.5

65.0
G (EX)
25.0 75.0
TAPER STORAGE RD-01 (OFFICER SOUTH ROAD)
3.5 3.5

STORAGE
75.0 25.0

25.0
STORAGE TAPER

G (EX)
G (EX)
2\PS531592
INTERSECTION IN-08 LIMIT OF
WORKS APPROX. 115m SOUTH,
3\PS531592 1\PS512549 2\PS705115
REFER DRG. 304200666-0201 5.0

G (EX)
G (EX)

5.0
FOR DETAILS

3.0

G (EX)
G (EX)

3.0
G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX)

3.5

3.5 3.5 3.5

3.5 3.5
G (EX)
G (EX)

3.5 3.5 3.5


3.5 3.5

G (EX)

3.5
3.0

G (EX)

3.0
5.0
1\TP128503 G (EX) 5.0
INTERSECTION IN-08 LIMIT OF 1\PS60266
WORKS APPROX. 50m NORTH ,
25.0 75.0 REFER DRG. 304200666-0202

STORAGE
TAPER STORAGE FOR DETAILS

25.0
4.0
3.5 3.5
RD-01 (OFFICER SOUTH ROAD)
G (EX)

75.0 25.0
STORAGE TAPER
G (EX)

STORAGE

3.5 3.5
75.0

TAPER
15.0
G (EX)

CONNECTOR ROAD
G (EX)

1.5

GENERAL NOTES: KEY 1.5


G (EX)

1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL. 3.0
PROPOSED RESERVE BOUNDARY 3.5
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.

IN-08
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS ARE
EXISTING TITLE BOUNDARY
(AERIAL PHOTOGRAPHY) ON WHICH THE SETOUT DETAIL IS BASED.
TAPER
G (EX)
15.0

PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND


SERVICES SHOULD BE VERIFIED ON SITE. ULTIMATE DESIGN

3. INTERSECTION - IN-08
VPA BASE
G (EX)

4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 7.

5. INTERSECTION TYPE -PRIMARY ARTERIAL / CONNECTOR ROAD

6. DECLARED MAIN ROAD - RD-01 (OFFICER SOUTH ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
LIMIT OF WORKS
G (EX)

LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H WARNING
20 BEWARE OF UNDERGROUND SERVICES
PLAN - INTERSECTION IN-08
0 10 30 40 50m
THE LOCATIONS OF UNDERGROUND SERVICES ARE
7. DESIGN VEHICLE - 26m B-DOUBLE APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
SCALE: 1:500 SCALE 1:500 @A1
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


G.STENTON 02-06-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project
CAD File: 304200666-0545.dwg

Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 43 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-08 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY 304200666-0545 P3
DATE PLOTTED: 14 September 2023 6:19 PM BY : BECKMANS, TIM

RD-03 (THOMPSONS ROAD)

LIMIT OF WORKS
LIMIT OF WORKS

CONNECTOR ROAD
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

3.5

25.0
TAPER

3\L
RD-03
P2
REFER DRG. 304200666-0402
FOR DETAILS
05 103

TAPER
15.0
3.0
1.5

5.5
25.0 75.0
TAPER STORAGE 1.5

STORAGE
3.0

25.0
3.5
BRIDGE CROSSING BU-04
(DESIGNED BY OTHERS)
5.0

RD-03 (THOMPSONS ROAD) RD-03 (THOMPSONS ROAD)

5.0
3.0

3.0
3.5

3.5 3.5

3.5 3.5
LIMIT OF WORKS

3.5 3.5 3.5


3.5 3.5
3.5

3.0
RD-03
REFER DRG. 304200666-0401
75.0 25.0
FOR DETAILS
STORAGE TAPER

IN-09
GENERAL NOTES: KEY
1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.
PROPOSED RESERVE BOUNDARY
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE 1\T 3\L
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED. P3 EXISTING TITLE BOUNDARY
P 205
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND 700
SERVICES SHOULD BE VERIFIED ON SITE. 56 ULTIMATE DESIGN 103
3. INTERSECTION - IN-09
VPA BASE
4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 13

5. INTERSECTION TYPE - PRIMARY ARTERIAL / CONNECTOR ROAD

6. DECLARED MAIN ROAD - RD-03 (THOMPSONS ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H WARNING
PLAN - INTERSECTION IN-09 0 10 20 30 40 50m BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE
7. DESIGN VEHICLE - 26m B-DOUBLE
SCALE: 1:500
APPROXIMATE ONLY AND THEIR EXACT POSITION
SCALE 1:500 @A1 SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


G.STENTON 02-06-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project
CAD File: 304200666-0551.dwg

Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 44 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-09 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY 304200666-0551 P3
DATE PLOTTED: 14 September 2023 6:20 PM BY : BECKMANS, TIM

STORAGE
150.0
503
128

RD-01 (OFFICER SOUTH ROAD)


P

TAPER
1\T

25.0
03
051
P2
3.5 3.5

2\L
3.5

RD-03
REFER DRG. 304200666-0402
FOR DETAILS
3.0

CULVERT CROSSING CU-03


XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

(REFER DRG. 304200666 -1060 FOR FURTHER DETAILS)

STORAGE
50.0
25.0 145.0
TAPER STORAGE
150.0

9
TAPER

2
113
3.5 3.5 3.5
RD-03 (THOMPSONS ROAD)

P4
1\T
4.5

RD-03 (THOMPSONS ROAD)

5. 0
3.0

3.0
3.5

3.5 3.5 3.5

3.5 3.5
LIMIT OF WORKS

3.5 3.5 3.5


3.5 3.5

3.5
3.0

3.0
62

5.0
103

582
205

5.0
P5
P

1\T
3\L

3.5 3.5 3.5


25.0 150.0 100.0
TAPER STORAGE STORAGE

STORAGE

STORAGE
40.0

50.0
1.5

OAD
CONNECTOR R
TAPER
25.0

TAPER
15.0
GENERAL NOTES: KEY
3.5

IN-10
1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.
PROPOSED RESERVE BOUNDARY
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE
EXISTING TITLE BOUNDARY
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED.
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND 1.5
SERVICES SHOULD BE VERIFIED ON SITE. ULTIMATE DESIGN 3.0
3. INTERSECTION - IN-10
VPA BASE
4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 5
3.5 3.5
5. INTERSECTION TYPE - PRIMARY ARTERIAL / PRIMARY ARTERIAL / CONNECTOR ROAD

6. DECLARED MAIN ROAD - RD-01 (OFFICER SOUTH ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
DECLARED MAIN ROAD - RD-03 (THOMPSONS ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H WARNING
LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H PLAN - INTERSECTION IN-10 0 10 20 30 40 50m BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE

SCALE: 1:500
APPROXIMATE ONLY AND THEIR EXACT POSITION
7. DESIGN VEHICLE - 26m B-DOUBLE SCALE 1:500 @A1 SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


VICTORIAN PLANNING AUTHORITY
CAD File: 304200666-0555_0556.dwg

G.STENTON 02-06-2023
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 45 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-10 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY - SHEET 1 OF 2 304200666-0555 P3
DATE PLOTTED: 14 September 2023 6:21 PM BY : BECKMANS, TIM

150.0 55.0
STORAGE TAPER

OUTH ROAD)
KEY

PROPOSED RESERVE BOUNDARY

EXISTING TITLE BOUNDARY

ULTIMATE DESIGN
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

VPA BASE
3.5 3.5 3.5

GENERAL NOTES:
3.0

LIM
1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.

IT O
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE
RD-01 (OFFICER SOUTH ROAD)

F
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED.

W
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND

ORK
SERVICES SHOULD BE VERIFIED ON SITE.

S
3. INTERSECTION - IN-10

4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 5

5. INTERSECTION TYPE - PRIMARY ARTERIAL / PRIMARY ARTERIAL / CONNECTOR ROAD

6. DECLARED MAIN ROAD - RD-01 (OFFICER SOUTH ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
RD-01 DECLARED MAIN ROAD - RD-03 (THOMPSONS ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
REFER DRG. 304200666-0201 LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H
FOR DETAILS
7. DESIGN VEHICLE - 26m B-DOUBLE

SCALE: 1:500

20.0 1.5
TAPER
3.0

3.5 3.5

CONNECTOR ROAD
RKS
OF WO
LIMIT

RD-03 (THOMPSO

IN-10
NS RO AD) LIM
IT O
FW
ORK
S

25.0 RD-03
TAPER REFER DRG. 304200666-0403
FOR DETAILS

WARNING
0 10 20 30 40 50m BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE

SCALE: 1:500 SCALE: 1:500 SCALE 1:500 @A1


APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


VICTORIAN PLANNING AUTHORITY
CAD File: 304200666-0555_0556.dwg

G.STENTON 02-06-2023
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 46 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-10 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY - SHEET 2 OF 2 304200666-0556 P3
DATE PLOTTED: 14 September 2023 6:22 PM BY : BECKMANS, TIM

RD-03 (THOMPSONS ROAD) LIMIT OF WORKS

3.5

CONNECTOR ROAD
LIMIT OF WORKS

TAPER
25.0
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

3.0

TAPER
15.0
RD-03 1.5
REFER DRG. 304200666-0404
1.5

STORAGE
FOR DETAILS

30.0
STORAGE
3.5 3.5

25.0
25.0 75.0
TAPER STORAGE
75.0 25.0
STORAGE TAPER
5.5 5.0

RD-03 (THOMPSONS ROAD)

5.0
RD-03 (THOMPSONS ROAD)

3.0

3.0
3.5

3.5 3.5 3.5

3.5 3.5
LIMIT OF WORKS

3.5 3.5 3.5


3.5 3.5

3.5
3.0

3.0
5.0
5.5
5.0
RD-03

STORAGE
REFER DRG. 304200666-0403

25.0
FOR DETAILS
25.0 75.0 3.5 3.5
TAPER STORAGE 75.0 25.0
STORAGE TAPER
1.5

STORAGE
35.0
3.0

1\TP128503
TAPER
15.0
1.5

CONNECTOR ROAD
TAPER
25.0
GENERAL NOTES: KEY
1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.
PROPOSED RESERVE BOUNDARY

IN-11
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE
EXISTING TITLE BOUNDARY
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED.
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND
SERVICES SHOULD BE VERIFIED ON SITE. ULTIMATE DESIGN 3.5

3. INTERSECTION - IN-11
VPA BASE
4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 7

5. INTERSECTION TYPE - PRIMARY ARTERIAL / CONNECTOR ROAD LIMIT OF WORKS


6. DECLARED MAIN ROAD - RD-03 (THOMPSONS ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H WARNING
PLAN - INTERSECTION IN-11 0 10 20 30 40 50m
BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE
7. DESIGN VEHICLE - 26m B-DOUBLE
SCALE: 1:500
APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
SCALE 1:500 @A1 GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


G.STENTON 02-06-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project
CAD File: 304200666-0561.dwg

Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 47 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-11 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY 304200666-0561 P3
DATE PLOTTED: 14 September 2023 6:23 PM BY : BECKMANS, TIM

LIMIT OF WORKS
LIMIT OF WORKS

3.5 3.5

CONNECTOR ROAD
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XC-DESN-ULT; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-TPZ

3.5

25.0
RD-03 (THOMPSONS ROAD) RD-03
REFER DRG. 304200666-0405
TAPER FOR DETAILS
3.0

L\PS805124 1.5

TAPER
15.0
5.5

25.0 75.0 3.5

STORAGE
TAPER STORAGE

25.0
1.5
3.0

RD-03 (THOMPSONS ROAD) 5.0

5.0
3.0

3.0
3.5

3.5 3.5

3.5 3.5
LIMIT OF WORKS

3.5 3.5 3.5


3.5 3.5

3.0
RD-03
REFER DRG. 304200666-0404 75.0 25.0
FOR DETAILS STORAGE TAPER

L\PS805124
GENERAL NOTES:
1.

2.
ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.

BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED.
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND
KEY

PROPOSED RESERVE BOUNDARY

EXISTING TITLE BOUNDARY


IN-12
SERVICES SHOULD BE VERIFIED ON SITE. ULTIMATE DESIGN

3. INTERSECTION - IN-12
VPA BASE
4. BESPOKE ARRANGEMENT BASED ON VPA BENCHMARK DESIGN ITEM 13

5. INTERSECTION TYPE - PRIMARY ARTERIAL / CONNECTOR ROAD

6. DECLARED MAIN ROAD - RD-03 (THOMPSONS ROAD) - SPEED ZONE 80 KM/H - DESIGN SPEED 80 KM/H
LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H WARNING
PLAN - INTERSECTION IN-12 0 10 20 30 40 50m BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE
7. DESIGN VEHICLE - 26m B-DOUBLE
SCALE: 1:500
APPROXIMATE ONLY AND THEIR EXACT POSITION
SCALE 1:500 @A1 SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


G.STENTON 02-06-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project
CAD File: 304200666-0565.dwg

Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 48 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. INTERSECTION IN-12 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au INTERIM LAYOUT WITH ULTIMATE OVERLAY 304200666-0565 P3
DATE PLOTTED: 14 September 2023 6:24 PM BY : BECKMANS, TIM
XREF's: 304200666-XC-ANNO; 304200666-XC-DESN; 304200666-XC-INT-BATT; 304200666-XC-INT; 304200666-XV-SERV; 304200666-XY-AERL; 304200666-XY-BDRY; 304200666-XY-CADA; 304200666-XY-EASE; 304200666-XC-INT-KEY; 304200666-XY-BASE; 304200666-XC-DESN-INTRM; 304200666-XC-DESN-ULT; 304200666-XC-TPZ

CONNECTOR ROAD
20\PP3363

LIMIT OF WORKS
G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) 3.5
G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX) G (EX)

LECKY ROAD

3.0
1.5 3.5
1.5
3.0

LIMIT OF WORKS

1\PS602663

GENERAL NOTES: KEY


1. ALL DIMENSIONS & RADII ARE IN METRES & ARE TO THE FACE OF KERB & CHANNEL.

POS-01
PROPOSED RESERVE BOUNDARY
2. BASE INFORMATION OBTAINED FROM GIS DATABASE FROM VPA DATED 10 MARCH 2023.
STANTEC DOES NOT TAKE ANY RESPONSIBILITY FOR THE ACCURACY OF THE EXISTING CONDITIONS BASE
EXISTING TITLE BOUNDARY
OR AERIAL PHOTOGRAPHY ON WHICH THE SETOUT DETAIL IS BASED.
PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE EXISTING CONDITIONS INCLUDING UNDERGROUND
SERVICES SHOULD BE VERIFIED ON SITE. ULTIMATE DESIGN

3. INTERSECTION - POS-01
VPA BASE
4. BASED ON VPA BENCHMARK DESIGN.

5. INTERSECTION TYPE - PEDESTRIAN CROSSING CONNECTOR ROAD

6. LOCAL ROAD - PROPOSED CONNECTOR ROAD - SPEED ZONE 50 KM/H - DESIGN SPEED 50 KM/H
WARNING
7. DESIGN VEHICLE - 12.5m TRUCK PLAN - PEDESTRIAN CROSSING POS-01 0 10 20 30 40 50m BEWARE OF UNDERGROUND SERVICES
THE LOCATIONS OF UNDERGROUND SERVICES ARE

SCALE: 1:500
APPROXIMATE ONLY AND THEIR EXACT POSITION
SCALE 1:500 @A1 SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


G.STENTON 02-06-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project
CAD File: 304200666-0601.dwg

Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
R.ABRAHAM 02-06-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
P3 15-09-2023 AMENDED FINAL CONCEPT DESIGN SUBMISSION RA AD MP
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 49 of 62 MGA/AHD 1:500 A1
party arising out of any use or reliance by third party on the Approved
P2 15-08-2023 FINAL CONCEPT DESIGN SUBMISSION RA AD MP Melbourne VIC 3000 Drawing Number Revision
content of this document. PEDESTRIAN CROSSING POS-01 - LAYOUT PLAN
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
RA
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au
304200666-0601 P3
DATE PLOTTED: 16 August 2023 4:23 PM BY : DANE CARROLL

35
35.0 .0
36.0
.5
36

.0
36
34.5

35.5

34.5
34.0
37.5

NORTH

35.0

35
34.5

.0
35.5
.5
34

35
35.0

35.

34.5
36.0

.5
0
35.0

34.0

34.5
.5
35
34.5
34.5

34.5
36.0

℄ CARDINIA CREEK

35.0
36
.5

34.5
34.0
37.5

35.0

34.0
37.5

34.
5

0
34.
GGF HABITAT
.5

34.5
37

34.5
34.5
WEST LIMITS 35.5

35.5

36.5

ABUTMENT A

ABUTMENT B
34.0
℄ BEARINGS,

℄ BEARINGS,
33.5
36.0

34.5
37.0

℄ PIER 10

℄ PIER 11

℄ PIER 12

℄ PIER 13

℄ PIER 14
35

℄ PIER 1

℄ PIER 2

℄ PIER 3

℄ PIER 4

℄ PIER 5

℄ PIER 6

℄ PIER 7

℄ PIER 8

℄ PIER 9
.0

35.0
34.0

5
5

34.
36.

.0
36

5
35.

35.0
35.0

35.5
34.5
35.0

36.0

35.0
35.0 34.5

34.0

LIMIT OF WORKS
LIMIT OF WORKS
35.0

34.5
35.0 34.

33.5
0

35.0

.0
35
.0
35

35.
0
5
35.

.0
36

34.0
34.0
35.

LIMIT OF WORKS

35.
5

5
.5
37. 36
0 34.5

℄ BRIDGE

.5

34.5
34
35.5

34
36.0

.5
MINTA POND 3 EAST LIMITS

34.5
36.5
37.5

34.5
38.0

34.5
5
34.

35.5
36.5

34.5
34

35.0
.0

34.5
34.0

5
33.
34.5

34.0

0
34.
APPROACH SLAB TOE OF BANK (TYP) APPROACH SLAB TOE OF BANK (TYP)

34.0
XREF's: 304200666-SB-STRUCTURES-PLAN; 304200666-XC-EX CONT; 304200666-XY-CADA; 304200666-XY-BASE; OSPSP-01-RA-CTRL-1000; 30420066-SB-AERIAL IMAGE; 304200666-XV-SERV; GGF_Corridors; Approximate1%AEPExents; Existing Waterways

35
36.5

37.0 .0

34.5
.0

34.
36

35.
5

5
36.

5
34.0
35.
0
35.5

34.0

35.0
35.5
33
35.0

5
.5

35.
33.5
34.
0
.0
35

SITE BOUNDARY EXISTING TITLE BOUNDARY GGF HABITAT 34.0


VPA BASE PLAN
36.0

EAST LIMITS AND

35
34.0
35.0

.0

.5
34

5
35.5

35.
VPA BASE PLAN
35.5

.5
35.0

.0
35

34 35
37
.0
.0

34.0
.5

34.0
34

35.5
.5 35.5
35
.5
36.

OVERALL PLAN
SCALE 1:750
FOR LOCATION, SEE DRAWING No.'s 304200666-0005 AND 304200666-0010

NOTES:
1. BRIDGE LENGTH AND ARRANGEMENT IS INDICATIVE ONLY AND SUBJECT TO CHANGE UPON FURTHER
DESIGN DEVELOPMENT AND INPUT FROM MELBOURNE WATER.
LEGEND 2. NOMINAL BRIDGE DIMENSIONS HAVE BEEN ADOPTED FOR CONSISTENCY WITH PREVIOUS BENCHMARK
FOR ADDITIONAL LEGEND INFORMATION SEE DRAWING No. 304200666-0001 INFRASTRUCTURE COSTING PROJECT.
3. BRIDGE CONCEPT DESIGN HAS BEEN BASED ON BENCHMARK INFRASTRUCTURE DESIGN ITEM 24 AND FOR
EXISTING SURFACE CONTOUR
THE PURPOSES OF APPROXIMATE COSTING. STANTEC IS NOT LIABLE FOR ANY INACCURACY OF THE
PROPOSED ROAD CONTROL LINE
INFORMATION PROVIDED. FURTHER DETAILED WORKS ARE REQUIRED FOR ACCURACY.
PROPOSED ROAD RESERVE BOUNDARY
4. ALL BRIDGE STRUCTURAL ELEMENTS ARE TO BE CONFIRMED DURING DETAILED DESIGN.
PROPOSED BATTER 5. 1% AEP FLOOD LEVELS ARE BASED ON PEAK FLOW RATES EXTRACTED FROM MELBOURNE WATER
PROPOSED BRIDGE PROVIDED RORB MODEL, AND PRELIMINARY HYDRAULIC MODELLING UNDERTAKEN IN HEC-RAS BY STANTEC.
SAFETY FENCE
CAD File: C:\pwworkdir\ap_projects01\d0187389\304200666-1000.dwg

INTERIM ROAD DESIGN


ULTIMATE ROAD DESIGN
WARNING
INDICATIVE PROPOSED 1% AEP FLOOD EXTENTS BEWARE OF UNDERGROUND SERVICES
0 15 30 45 60 75m
ROCK PROTECTION THE LOCATIONS OF UNDERGROUND SERVICES ARE
APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GROWING GRASS FROG HABITAT SCALE 1:750 @A1 GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


D.CARROLL 16-08-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
A.CHAUDRY 16-08-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 50 of 62 MGA/AHD AS SHOWN A1
party arising out of any use or reliance by third party on the Approved
P2 16-08-2023 FINAL CONCEPT DESIGN SUBMISSION AC MP MP Melbourne VIC 3000 Drawing Number Revision
content of this document. PEDESTRIAN BRIDGE PB-01
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
AC
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au SHEET 1 OF 4 304200666-1000 P2
DATE PLOTTED: 16 August 2023 4:21 PM BY : DANE CARROLL

NORTH 35
.0

3 5 .0
34.0

5
34.
5
35.

35.0
34.5
℄ CARDINIA CREEK

36.0
TOE OF BANK

35.0
1 35.0

MATCH LINE, FOR CONTINUED PLAN REFER DRG No. 1002


1003
℄ BEARINGS, ℄ PIER 1 ℄ PIER 2 ℄ PIER 3 ℄ PIER 4 ℄ PIER 5
ABUTMENT A

34.5
LIMIT OF WORKS
35.0 34.

33.5
0

10800 INDICATIVE
35.0

.0
35
35.
0
.0
36
34.0
35.

35.
XREF's: 304200666-SB-STRUCTURES-PLAN; 304200666-XC-EX CONT; 304200666-XY-CADA; 304200666-XY-BASE; OSPSP-01-RA-CTRL-1000; 304200666-SB-STRUCTURES-SECTIONS; 30420066-SB-AERIAL IMAGE; 304200666-XV-SERV; GGF_Corridors; Approximate1%AEPExents; Existing Waterways

LIMIT OF WORKS
5

5
.5

37.
36

0 34.5

.5

34.5
APPROACH SLAB

34
35.5

34
36.0

.5
MINTA POND 3 EAST LIMITS SITE BOUNDARY EXISTING TITLE BOUNDARY

36.5
34.5

5
34.
36.5

PLAN
SCALE 1:250 FOR LOCATION, SEE DRAWING No.'s 304200666-0005 AND 304200666-0010

MATCH LINE, FOR CONTINUED ELEVATION REFER DRG No. 1002


4000 OVERALL LENGTH OF DECK = 375000
APPROACH SLAB
3000 5760 25000 25000 25000 25000 25000
SHARED USER PATH SPAN 1 SPAN 2 SPAN 3 SPAN 4 SPAN 5
(BY OTHERS)
APPROACH SLAB ℄ BRIDGE UNDERSIDE OF BRIDGE INDICATIVE 1% AEP
(APPROX. RL 36.54m AHD) (APPROX. RL 35.55m AHD) (APPROX. RL 34.95m AHD)

CHANNEL INVERT
(APPROX. RL 33.13m AHD)
APPROX. EXISTING SURFACE ROCK PROTECTION FOUNDATIONS SHOWN
ARE INDICATIVE ONLY
ABUTMENT B
℄ BEARINGS,

℄ PIER 1

℄ PIER 2

℄ PIER 3

℄ PIER 4

℄ PIER 5
ELEVATION
SCALE 1:250
LEGEND
FOR ADDITIONAL LEGEND INFORMATION SEE DRAWING No. 304200666-0001
EXISTING SURFACE CONTOUR
PROPOSED ROAD CONTROL LINE
PROPOSED ROAD RESERVE BOUNDARY
PROPOSED BATTER
PROPOSED BRIDGE
SAFETY FENCE
CAD File: C:\pwworkdir\ap_projects01\d0187389\304200666-1001.dwg

INTERIM ROAD DESIGN


ULTIMATE ROAD DESIGN
WARNING
INDICATIVE PROPOSED 1% AEP FLOOD EXTENTS BEWARE OF UNDERGROUND SERVICES
0 5 10 15 20 25m
ROCK PROTECTION THE LOCATIONS OF UNDERGROUND SERVICES ARE
APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GROWING GRASS FROG HABITAT SCALE 1:250 @A1 GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


D.CARROLL 16-08-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
A.CHAUDRY 16-08-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 51 of 62 MGA/AHD AS SHOWN A1
party arising out of any use or reliance by third party on the Approved
P2 16-08-2023 FINAL CONCEPT DESIGN SUBMISSION AC MP MP Melbourne VIC 3000 Drawing Number Revision
content of this document. PEDESTRIAN BRIDGE PB-01
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
AC
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au SHEET 2 OF 4 304200666-1001 P2
DATE PLOTTED: 16 August 2023 4:22 PM BY : DANE CARROLL

NORTH

35.0
35.0

34.5 1
MATCH LINE, FOR CONTINUED PLAN REFER DRG No. 1001

MATCH LINE, FOR CONTINUED PLAN REFER DRG No. 1003


1003

3 4 .0
℄ PIER 6 ℄ PIER 7 ℄ PIER 8 ℄ PIER 9 ℄ PIER 10 ℄ PIER 11 ℄ PIER 12 ℄ PIER 13

℄ BRIDGE

34.0
GGF HABITAT VPA BASE PLAN
EAST LIMITS AND
VPA BASE PLAN

34.5
XREF's: 304200666-SB-STRUCTURES-PLAN; 304200666-XC-EX CONT; 304200666-XY-CADA; 304200666-XY-BASE; OSPSP-01-RA-CTRL-1000; 304200666-SB-STRUCTURES-SECTIONS; 30420066-SB-AERIAL IMAGE; 304200666-XV-SERV; Approximate1%AEPExents

34.5
PLAN
SCALE 1:250 FOR LOCATION, SEE DRAWING No.'s 304200666-0005 AND 304200666-0010

MATCH LINE, FOR CONTINUED ELEVATION REFER DRG No. 1003


OVERALL LENGTH OF DECK = 375000
MATCH LINE, FOR CONTINUED PLAN REFER DRG No. 1001

25000 25000 25000 25000 25000 25000 25000 25000


SPAN 6 SPAN 7 SPAN 8 SPAN 9 SPAN 10 SPAN 11 SPAN 12 SPAN 13

UNDERSIDE OF BRIDGE INDICATIVE 1% AEP TOP OF DECK ON ℄ BRIDGE


(APPROX. RL 35.55m AHD) (APPROX. RL 34.95m AHD) (APPROX. RL 36.54m AHD)

CHANNEL INVERT
(APPROX. RL 33.55m AHD)
FOUNDATIONS SHOWN APPROX. EXISTING SURFACE
ARE INDICATIVE ONLY

℄ PIER 10

℄ PIER 11

℄ PIER 12

℄ PIER 13
℄ PIER 6

℄ PIER 7

℄ PIER 8

℄ PIER 9

ELEVATION
SCALE 1:250
LEGEND
FOR ADDITIONAL LEGEND INFORMATION SEE DRAWING No. 304200666-0001
EXISTING SURFACE CONTOUR
PROPOSED ROAD CONTROL LINE
PROPOSED ROAD RESERVE BOUNDARY
PROPOSED BATTER
PROPOSED BRIDGE
SAFETY FENCE
CAD File: C:\pwworkdir\ap_projects01\d0187389\304200666-1002.dwg

INTERIM ROAD DESIGN


ULTIMATE ROAD DESIGN
WARNING
INDICATIVE PROPOSED 1% AEP FLOOD EXTENTS BEWARE OF UNDERGROUND SERVICES
0 5 10 15 20 25m
ROCK PROTECTION THE LOCATIONS OF UNDERGROUND SERVICES ARE
APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GROWING GRASS FROG HABITAT SCALE 1:250 @A1 GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


D.CARROLL 16-08-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
A.CHAUDRY 16-08-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 52 of 62 MGA/AHD AS SHOWN A1
party arising out of any use or reliance by third party on the Approved
P2 16-08-2023 FINAL CONCEPT DESIGN SUBMISSION AC MP MP Melbourne VIC 3000 Drawing Number Revision
content of this document. PEDESTRIAN BRIDGE PB-01
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
AC
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au SHEET 3 OF 4 304200666-1002 P2
DATE PLOTTED: 16 August 2023 5:26 PM BY : DANE CARROLL

5
34.
NORTH
VPA BASE PLAN

35.5
SHARED PATH TIE IN WITH
EXISTING SURFACE = 27000 4000
1 PEDESTRIAN
MATCH LINE, FOR CONTINUED PLAN REFER DRG No. 1002

- PATH
℄ PIER 14 ℄ BEARINGS, 35.0
TOE OF BANK
ABUTMENT B
℄ BRIDGE TOP OF DECK ON ℄
(APPROX. RL 36.54m AHD)
GUARDRAIL,
AS 1428.1 REINFORCED
COMPLIANT (TYP) CONCRETE DECK

1400
TYP
2%

LIMIT OF WORKS
9900 INDICATIVE
2 No. 750mm DEEP

600
UNDERSIDE OF BRIDGE
℄ BRIDGE (APPROX. RL 35.55m AHD) OPEN FLANGE
SUPER T GIRDERS

2720
CHANNEL INVERT
(RL VARIES)

1292 MIN.

HEIGHT
.5

PIER
35
FOUNDATIONS
SHOWN ARE
APPROACH SLAB TOE OF BANK INDICATIVE ONLY
INDICATIVE 1% AEP
(APPROX. RL 34.95m AHD)
XREF's: OSPSP-01-RA-CTRL-1000; 304200666-SB-STRUCTURES-SECTIONS; 30420066-SB-AERIAL IMAGE; 304200666-XC-EX CONT; 304200666-XY-CADA; 304200666-XY-BASE; 304200666-XV-SERV; 304200666-SB-STRUCTURES-PLAN; Approximate1%AEPExents

4\PS446665 SECTION 1
SCALE 1:100 1001, 1002 & 1003

35.5
35.5
34.

PLAN
SCALE 1:250 FOR LOCATION, SEE DRAWING No.'s 304200666-0005 AND 304200666-0010
MATCH LINE, FOR CONTINUED ELEVATION REFER DRG No. 1002

OVERALL LENGTH OF DECK = 375000 4000


APPROACH SLAB
25000 25000 SHARED PATH TIE IN WITH
SPAN 14 SPAN 15 EXISTING SURFACE = 27000

UNDERSIDE OF BRIDGE INDICATIVE 1% AEP APPROACH SLAB ON ℄ BRIDGE LIMIT OF WORKS


(APPROX. RL 35.55m AHD) (APPROX. RL 34.95m AHD) (APPROX. RL 36.54m AHD)

CHANNEL INVERT
(APPROX. RL 34.035m AHD)

FOUNDATIONS SHOWN ROCK PROTECTION APPROX.


ARE INDICATIVE ONLY EXISTING
SURFACE
ABUTMENT B
℄ BEARINGS,

NOTES:
℄ PIER 14

1. BRIDGE LENGTH AND ARRANGEMENT IS INDICATIVE ONLY AND SUBJECT TO CHANGE UPON FURTHER
DESIGN DEVELOPMENT AND INPUT FROM MELBOURNE WATER.
2. NOMINAL BRIDGE DIMENSIONS HAVE BEEN ADOPTED FOR CONSISTENCY WITH PREVIOUS BENCHMARK
ELEVATION INFRASTRUCTURE COSTING PROJECT.
SCALE 1:250 3. BRIDGE CONCEPT DESIGN HAS BEEN BASED ON BENCHMARK INFRASTRUCTURE DESIGN ITEM 24 AND FOR
LEGEND THE PURPOSES OF APPROXIMATE COSTING. STANTEC IS NOT LIABLE FOR ANY INACCURACY OF THE
FOR ADDITIONAL LEGEND INFORMATION SEE DRAWING No. 304200666-0001 INFORMATION PROVIDED. FURTHER DETAILED WORKS ARE REQUIRED FOR ACCURACY.
EXISTING SURFACE CONTOUR 4. ALL BRIDGE STRUCTURAL ELEMENTS ARE TO BE CONFIRMED DURING DETAILED DESIGN.
PROPOSED ROAD CONTROL LINE 5. 1% AEP FLOOD LEVELS ARE BASED ON PEAK FLOW RATES EXTRACTED FROM MELBOURNE WATER
PROPOSED ROAD RESERVE BOUNDARY PROVIDED RORB MODEL, AND PRELIMINARY HYDRAULIC MODELLING UNDERTAKEN IN HEC-RAS BY STANTEC.
PROPOSED BATTER
PROPOSED BRIDGE
SAFETY FENCE
CAD File: C:\pwworkdir\ap_projects01\d0187389\304200666-1003.dwg

INTERIM ROAD DESIGN 0 1 2 4 6 8 10m

ULTIMATE ROAD DESIGN SCALE 1:100 @A1


WARNING
INDICATIVE PROPOSED 1% AEP FLOOD EXTENTS BEWARE OF UNDERGROUND SERVICES
0 5 10 15 20 25m
ROCK PROTECTION THE LOCATIONS OF UNDERGROUND SERVICES ARE
APPROXIMATE ONLY AND THEIR EXACT POSITION
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS
GROWING GRASS FROG HABITAT SCALE 1:250 @A1 GIVEN THAT ALL EXISTING SERVICES ARE SHOWN

Drawn Date Client


D.CARROLL 16-08-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
A.CHAUDRY 16-08-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 53 of 62 MGA/AHD AS SHOWN A1
party arising out of any use or reliance by third party on the Approved
P1 16-08-2023 FINAL CONCEPT DESIGN SUBMISSION AC MP MP Melbourne VIC 3000 Drawing Number Revision
content of this document. PEDESTRIAN BRIDGE PB-01
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
AC
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au SHEET 4 OF 4 304200666-1003 P2
DATE PLOTTED: 16 August 2023 4:26 PM BY : DANE CARROLL

GGF HABITAT

24. 5
WEST LIMITS AND VPA BASE PLAN SITE BOUNDARY
VPA BASE PLAN

24
.5
TH
NOR

SHARED PATH TIE IN WITH EXISTING SURFACE = 36000 2\PS549475 SHARED PATH TIE IN WITH EXISTING SURFACE = 42000

TOE OF BANK 1 TOE OF BANK


-
℄ BEARINGS, ℄ PIER 1 ℄ PIER 2 ℄ BEARINGS,
ABUTMENT A ABUTMENT B

LIMIT OF WORKS
LIMIT OF WORKS

.0
24
.0
25 ℄ BRIDGE
APPROACH SLAB APPROACH SLAB

.5
24
GGF HABITAT
EAST LIMITS

24.5
TOE OF BANK EXISTING TITLE BOUNDARY TOE OF BANK

24.5
LOWER GUM SCRUB CREEK
XREF's: 304200666-XC-EX CONT; 304200666-XY-CADA; 304200666-XY-BASE; OSPSP-01-RA-CTRL-1000; 304200666-SB-STRUCTURES-SECTIONS; 30420066-SB-AERIAL IMAGE; 304200666-XV-SERV; 304200666-SB-STRUCTURES-PLAN; Approximate1%AEPExents

20\PP3363

24.0
24.
5

PLAN
SCALE 1:250 FOR LOCATION, SEE DRAWING No's. 304200666-0005 AND 304200666-0010

4000 OVERALL LENGTH OF DECK = 75000 4000


APPROACH SLAB 25000 25000 25000 APPROACH SLAB

SHARED PATH TIE IN WITH EXISTING SURFACE = 36000 SPAN 1 SPAN 2 SPAN 3 SHARED PATH TIE IN WITH EXISTING SURFACE = 42000

APPROACH SLAB ON ℄ BRIDGE UNDERSIDE OF BRIDGE INDICATIVE 1% AEP APPROACH SLAB ℄ BRIDGE
(APPROX. RL 25.86m AHD) (APPROX. RL 24.87m AHD) (APPROX. RL 24.27m AHD) (APPROX. RL 25.86m AHD)
LIMIT OF WORKS

LIMIT OF WORKS
CHANNEL INVERT
(APPROX. RL 23.26m AHD)
ROCK PROTECTION (TYP) FOUNDATIONS SHOWN
APPROX. EXISTING SURFACE
ARE INDICATIVE ONLY

4000
ABUTMENT A

ABUTMENT B
℄ BEARINGS,

℄ BEARINGS,
LEGEND PEDESTRIAN
℄ PIER 1

℄ PIER 2
FOR ADDITIONAL LEGEND INFORMATION SEE DRAWING No. 304200666-0001 PATH
EXISTING SURFACE CONTOUR ℄ BRIDGE TOP OF DECK ON ℄
PROPOSED ROAD CONTROL LINE (APPROX. RL 25.86m AHD)
PROPOSED ROAD RESERVE BOUNDARY ELEVATION
GUARDRAIL,
PROPOSED BATTER SCALE 1:250
AS 1428.1

1400
TYP
PROPOSED BRIDGE COMPLIANT (TYP) REINFORCED
2% CONCRETE DECK
SAFETY FENCE

600
NOTES:
INTERIM ROAD DESIGN UNDERSIDE OF BRIDGE 2 No. 750mm DEEP OPEN
1. BRIDGE LENGTH AND ARRANGEMENT IS INDICATIVE ONLY AND SUBJECT TO CHANGE UPON FURTHER DESIGN
ULTIMATE ROAD DESIGN (APPROX. RL 24.87m AHD) FLANGE SUPER T GIRDERS
DEVELOPMENT AND INPUT FROM MELBOURNE WATER.
INDICATIVE PROPOSED 1% AEP FLOOD EXTENTS 2. NOMINAL BRIDGE DIMENSIONS HAVE BEEN ADOPTED FOR CONSISTENCY WITH PREVIOUS BENCHMARK CHANNEL INVERT
ROCK PROTECTION INFRASTRUCTURE COSTING PROJECT. (APPROX. RL 23.26m AHD)
GROWING GRASS FROG HABITAT 3. BRIDGE CONCEPT DESIGN HAS BEEN BASED ON BENCHMARK INFRASTRUCTURE DESIGN ITEM 24 AND FOR THE
0 1 2 4 6 8 10m
PURPOSES OF APPROXIMATE COSTING. STANTEC IS NOT LIABLE FOR ANY INACCURACY OF THE INFORMATION INDICATIVE 1% AEP FOUNDATIONS SHOWN
CAD File: C:\pwworkdir\ap_projects01\d0187389\304200666-1010.dwg

PROVIDED. FURTHER DETAILED WORKS ARE REQUIRED FOR ACCURACY. (APPROX. RL 24.27m AHD) ARE INDICATIVE ONLY
SCALE 1:100 @A1 4. ALL BRIDGE STRUCTURAL ELEMENTS ARE TO BE CONFIRMED DURING DETAILED DESIGN.
WARNING
5. 1% AEP FLOOD LEVELS ARE BASED ON PEAK FLOW RATES EXTRACTED FROM MELBOURNE WATER PROVIDED
SECTION 1
BEWARE OF UNDERGROUND SERVICES
0 5 10 15 20 25m THE LOCATIONS OF UNDERGROUND SERVICES ARE
APPROXIMATE ONLY AND THEIR EXACT POSITION RORB MODEL, AND PRELIMINARY HYDRAULIC MODELLING UNDERTAKEN IN HEC-RAS BY STANTEC. PROPOSED GUM
SHOULD BE PROVEN ON SITE. NO GUARANTEE IS SCALE 1:100 -
SCALE 1:250 @A1 GIVEN THAT ALL EXISTING SERVICES ARE SHOWN SCRUB CREEK RE-CONSTRUCTED WATERWAY CROSS SECTIONS HAVE BEEN PROVIDED BY MELBOURNE WATER.

Drawn Date Client


D.CARROLL 16-08-2023 VICTORIAN PLANNING AUTHORITY
© Stantec Limited All Rights Reserved. Checked Date Project Status
OFFICER SOUTH EMPLOYMENT PRECINCT PSP
This document is produced by Stantec Limited solely for the FOR CONCEPT APPROVAL
benefit of and use by the client in accordance with the
Designed Date OFFICER SOUTH ROAD NOT TO BE USED FOR CONSTRUCTION PURPOSES
A.CHAUDRY 16-08-2023
terms of the retainer. Stantec Limited does not and shall not
Verified Date OFFICER SOUTH 3809 VIC SHEET No. DATUM Scale Size
assume any responsibility or liability whatsoever to any third Stantec Australia Pty Ltd | ABN 17 007 820 322
Level 4, 501 Swanston Street
Title
TRANSPORT CONCEPT DESIGN 54 of 62 MGA/AHD AS SHOWN A1
party arising out of any use or reliance by third party on the Approved
P2 16-08-2023 FINAL CONCEPT DESIGN SUBMISSION AC MP MP Melbourne VIC 3000 Drawing Number Revision
content of this document. PEDESTRIAN BRIDGE PB-02
P1
Rev.
02-06-2023
Date
DRAFT CONCEPT DESIGN SUBMISSION
Description
AC
Des.
MP MP
Verif. Appd.
Tel: 03 8415 7777
Web: www.stantec.com/au
304200666-1010 P2