HAZOP Worksheets

Project Title: Production of Nitric Acid


Group No.: Group 3
Date: 18/Mar/2024
Drawing No. and P-0006 (SHEET 14 OF 18, Rev.0) P-0006 (SHEET 15 OF 18, Rev.0) P-0006 (SHEET 16 OF 18, Rev.0)
Node No.: 1 Person-in-charged: Tan Chun Kiat Team Shummmmmm
Node Upstream Pump P-500 to downstream Heat Exchanger E-500 and Oxido-Adsorption Column R-500 outlet.
Design Intent: To promote the adsorption of nitrogen dioxide gas with water and oxidation of nitric oxid in formation of nitric acid. Water is pumped and heated to the desired pressure and temperature in the pump and heat exchanger .
Design Design Pressure: 1497 kPa (Pump P-500), 1497 kPa (Heat Exchanger E-500), 1430 kPa (Oxido-Adsorption Column R-500); Design Temperature: 30℃ (Pump P-500), 72℃ (Heat Exchanger E-500), 72℃ (Oxido-Adsorption Column R-500)
Operating Operating Pressure: 101.3 kPa (Inlet) / 1050 kPa (Outlet) (Pump P-500), 1050 kPa (Heat Exchanger E-500), 1000 kPa (Oxido-Adsorption Column R-500); Operating Temperature: 25℃ (Pump P-500), 25℃ (Inlet)/ 60℃(Outlet) (Heat Exchanger E-500), 60℃
condition: (Oxido-Adsorption Column R-500)
Guideword/ Party
Item Possible Causes Consequences Safeguards Recommendations
Deviation Responsible
1 1 1 No flow 1. SDV-501 malfunction closed 1.1. No Flow to P-500, leading to break 1.1.1. Low-Low Flow Alarm and Trip System (FZALL501) is provided. 1. Consider to remove V-410 drain valve. Consultant
down of P-500 due to pump minimum 1.1.2. SDV-502 is provided. 2. Investigate the effect of more tail gas in the tail gas
flow. 1.1.3. PM-503 is provided. treatment and provide adequate protection if required.
1.2. No Flow of water leading to 1.1.4. I-503 is provided. 3. Add Reverse Valve at R-500 water inlet stream.
potential high temperature in E-500. 1.1.5. Low Flow Controller Alarm FICAL-503 is provided.
1.3. Loss of production due to no flow of 1.2.1. High-High Temperature Alarm and Trip System (TZAHH503) is
water flowing into R-500. provided.
1.4. No Flow of water to R-500, leading to 1.2.2. SDV-503 is provided.
potential high pressure in R-500. 1.2.3. V-408 drain valve is provided.
1.2.4. Low Temperature Controller (TICL-504) is provided.
1.3.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
1.3.2. SDV-508 is provided.
1.3.3. Low Level Controller (LICL-506) is provided.
1.4.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
1.4.2. SDV-504 is provided.
1.4.3. PSV-500 is provided.
1.4.4. V-432 vent valve is provided.
1.4.5. High Pressure Controller (PICH-505) is provided.

1 1 2 2. FV-501 malfunction closed Refer to item no. 1.1.1. Refer to item no. 1.1.1. Refer to recommendation No Flow above (1,2,3) Consultant
1 1 3 3. M-503 malfunction Refer to item no flow above (1.2) Refer to item no flow above (1.2.1) 4. Consider to add Low-Low Flow Alarm and Trip System Consultant
Refer to item no flow above (1.3) Refer to item no flow above (1.2.2) (FZALL502) at P-500 pump outlet to shutdown SDV-501
Refer to item no flow above (1.4) Refer to item no flow above (1.2.3) and SDV-502.
Refer to item no flow above (1.2.4) 5. Install backup pump.
Refer to item no flow above (1.3.1)
Refer to item no flow above (1.3.2)
Refer to item no flow above (1.3.3)
Refer to item no flow above (1.4.1)
Refer to item no flow above (1.4.2)
Refer to item no flow above (1.4.3)
Refer to item no flow above (1.4.4)
Refer to item no flow above (1.4.5)
1 1 4 4. V-525 malfunction closed Refer to item no. 1.1.3. Refer to item no. 1.1.3. 6. Consider to place V-525 check valve after V-404 drain Consultant
valve.
7. Consider to add High-high Flow Alarm and Trip
System (FZAHH501) at P-500 inlet to shut down SDV-501
and SDV-502.
1 1 5 5. SDV-502 malfunction closed Refer to item no. 1.1.3. Refer to item no. 1.1.3. Refer to recommendation No Flow above (1,2,3) Consultant
1 1 6 6. SDV-503 malfunction closed 6.1. Potential loss of heating leading to 6.2.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided. 8. Consider to add Low-Low Temperature Alarm and Consultant
low temperature of E-500. 6.2.2. SDV-505 is provided. Trip System (TZALL503) at E-500 to alert operator.
6.2. Less temperature water inlet of R- 6.2.3. V-422 drain valve is provided.
500, leading to decrease reaction rate. 6.2.4. Low Temperature Controller Alarm (TICAL-507) is provided.

1 1 7 7. SDV-504 malfunction closed 7.1. No Flow of gas leading to potential 7.1.1. Low Temperature Controller Alarm (TICAL-507) is provided. 9. Consider changing philosophy of Low-Low Pressure Consultant
low temperature in R-500. Refer to item no flow above (6.2.1) Alarm and Trip System (PZALL504) to also shut down
7.2. Loss of production due to no flow of Refer to item no flow above (6.2.2) SDV-506 which prevents flooding of R-500.
process gas into R-500. Refer to item no flow above (6.2.3)
7.3. No Flow of process gas to R-500, 7.3.1. Low-low Pressure Alarm and Trip System (PZALL504) is provided.
leading to potential low pressure in R- 7.3.2. SDV-507 is provided.
500. 7.3.3. Low Pressure Controller (PICL-505) is provided.

1 1 8 8. V-526 malfunction closed Refer to item no flow above (1.1.7) Refer to item no flow above (1.1.7) N/A Consultant
HAZOP Worksheets

1 1 9 9. SDV-505 malfunction closed 9.1. No flow of coolant leads to potential 9.1.1. High-High Temperature Alarm and Trip System (TZAHH505) is Refer to recommendation No Flow above (2) Consultant
loss of cooling, possible thermal runaway provided.
and leading to decrease of reaction rate. 9.1.2. SDV-504 is provided.
9.2. More vapour is generated due to 9.1.3. SDV-506 is provided.
high temperature, leading to high 9.1.4. V-420 Drain Valve is provided.
pressure in R-500. 9.1.5. High Temperature Controller Alarm (TICAH-507) is provided.
Refer to item no flow above (1.4.1)
Refer to item no flow above (1.4.2)
Refer to item no flow above (1.4.3)
Refer to item no flow above (1.4.4)
Refer to item no flow above (1.4.5)

1 1 10 10. SDV-506 malfunction closed 10.1. No Flow of water leading to Refer to item no flow above (6.2.1) Refer to recommendation No Flow above (2) Consultant
potential low temperature in R-500. Refer to item no flow above (6.2.2)
Refer to item no flow above (1.3) Refer to item no flow above (6.2.3)
Refer to item no flow above (1.4) Refer to item no flow above (6.2.4)
Refer to item no flow above (1.3.1)
Refer to item no flow above (1.3.2)
Refer to item no flow above (1.3.3)
Refer to item no flow above (1.4.1)
Refer to item no flow above (1.4.2)
Refer to item no flow above (1.4.3)
Refer to item no flow above (1.4.4)
Refer to item no flow above (1.4.5)

1 2 1 More Flow 1. FV-501 malfunction stuck opened 1.1. More water flow to P-500, leading to 1.1.1. High-High Flow Alarm and Trip System (FZAHH502) is provided. Refer to No Flow above (7) Consultant
break down of P-500 due to pump 1.1.2. SDV-501 is provided. Refer to No Flow above (8)
maximum flow. 1.1.3. SDV-502 is provided. 10. Consider to add Alarm at Flow Indicator Controller
1.2. More water flow leading to potential 1.1.4. V-398 Drain Valve is provided. (FIC-501) to alert operator.
low temperature in E-500. 1.1.5. PM-503 is provided.
1.3. More water flow to R-500, lead to 1.1.6. I-503 is provided.
potential flooding and damage of tray in 1.1.7. High Flow Controller (FICH-502) is provided.
R-500. 1.1.8. High Flow Controller Alarm (FICAH-503) is provided.
1.4. More water flow to R-500, leading to 1.2.1. V-407 Drain Valve is provided.
potential low pressure in R-500. 1.2.2. Low Temperature Controller (TICL-504) is provided.
1.5. More water flow of low temperature 1.3.1. High-High Level Alarm and Trip System (LZAHH506) is provided.
water to R-500, leading to low 1.3.2. SDV-506 is provided.
temperature in R-500. 1.3.3. V-420 Drain Valve is provided.
1.3.4. High Level Controller (LICH-506) is provided.
1.4.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
1.4.2. SDV-507 is provided.
1.4.3. Low Pressure Controller (PICL-505) is provided.
1.5.1. Low-Low Temperatur Alarm and Trip System (TZALL505) is provided.
1.5.2. SDV-505 is provided.
1.5.3. V-422 Drain Valve is provided.
1.5.4. Low Temperature Controller Alarm (TICAL-507) is provided.

1 2 2 2. FV-502 malfunction stuck opened Refer to item more flow above (1.1) Refer to item more flow above (1.1.1) N/A Consultant
Refer to item more flow above (1.1.2)
Refer to item more flow above (1.1.3)
Refer to item more flow above (1.1.4)
Refer to item more flow above (1.1.5)
Refer to item more flow above (1.1.6)
Refer to item more flow above (1.1.7)
Refer to item more flow above (1.1.8)
HAZOP Worksheets

1 2 3 3. TV-504 malfunction stuck opened 3.1 More Flow of utility stream from E- 3.1.1. High-High Temperature Alarm and Trip System (TZAHH503) is 11. Consider to remove V-424 vent valve. Consultant
500, leading to potential high provided. Refer to recommendation No Flow above (2)
temperature of E-500. 3.1.2. SDV-503 is provided.
3.2 More Flow of utility stream from E- 3.1.3. V-408 drain valve is provided.
500, leading to potential high 3.2.1. High-High Temperature Alarm and Trip System (TZAHH505) is
temperature of R-500 due to high provided.
temperature water stream. 3.2.2. SDV-504 is provided.
3.3 More vapour is generated due to high 3.2.3. SDV-506 is provided.
temperature, leading to high pressure in 3.2.4. V-420 drain valve is provided.
R-500. 3.2.5. High Temperature Controller Alarm (TICAH-507) is provided.
3.3.1. High-High Pressure Alarm and Trip System (PZAHH504) is provided.
3.3.2. SDV-504 is provided.
3.3.3. PSV-500 is provided.
3.3.4. V-432 vent valve is provided.
3.3.5. High Pressure Controller (PICH-505) is provided.

1 2 4 4. PV-505 malfunction stuck opened 4.1 More flow from R-500, leading to Refer to item more flow above (1.4.1) 12. Consider to install check valve at the bottom liquid Consultant
potential low pressure in R-500. Refer to item more flow above (1.4.2) outlet of R-500 to prevent reverse flow before V-425
4.2 Low Pressure of R-500, leading to Refer to item more flow above (1.4.3) Drain Valve.
potential reverse flow of bottom liquid 4.3.1. V-425 drain valve is provided.
outlet stream. Refer to item more flow above (1.3.1)
4.3 Reverse Flow of bottom liquid outlet Refer to item more flow above (1.3.2)
stream, leading to potential high level in Refer to item more flow above (1.3.3)
R-500. Refer to item more flow above (1.3.4)

1 2 5 5. LV-506 malfunction stuck opened 5.1 More flow from R-500, leading to 5.1.1. Low-Low Level Alarm and Trip System (LZALL506) is provided. N/A Consultant
potential low level in R-500. 5.1.2. SDV-508 is provided.
5.2 Low level in R-500, leading to 5.1.3. High Flow Indicator and Alarm (FIAH-508) is provided.
potential high pressure in R-500. 5.1.4. Low Level Controller (LICL-506) is provided.
Refer to item more flow above (3.3.1)
Refer to item more flow above (3.3.2)
Refer to item more flow above (3.3.3)
Refer to item more flow above (3.3.4)
Refer to item more flow above (3.3.5)

1 2 6 6. TV-507 malfunction stuck opened 6.1 More Flow of utility stream from R- Refer to item more flow above (1.5.1) N/A Consultant
500, leading to potential low Refer to item more flow above (1.5.2)
temperature of R-500. Refer to item more flow above (1.5.3)
6.2 Low temperature of R-500, leading to Refer to item more flow above (1.5.4)
decrease of reaction rate.

1 3 1 Less Flow 1. FV-501 malfunction partially closed 1.1. Less Flow to P-500, leading to break 1.1.1. Low-Low Flow Alarm and Trip System (FZALL501) is provided. Refer to recommendations No Flow above (1, 2,3). Consultant
down of P-500 due to pump minimum 1.1.2. SDV-502 is provided.
flow. 1.1.3. PM-503 is provided.
1.2. Less Flow of water leading to 1.1.4. I-503 is provided.
potential high temperature in E-500. 1.1.5. Low Flow Controller (FICL-502) is provided.
1.3. Loss of production due to less flow 1.1.6. Low Flow Controller Alarm (FICAL-503) is provided.
of water flowing into R-500. 1.2.1. High-High Temperature Alarm and Trip System (TZAHH503) is
1.4. Less Flow to R-500, leading to provided.
potential high pressure in R-500. 1.2.2. SDV-503 is provided.
1.5. Less water flow to R-500, leading to 1.2.3. V-408 drain valve is provided.
high temperature in R-500. 1.2.4. High Temperature Controller (TICH-504) is provided.
1.3.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
1.3.2. SDV-508 is provided.
1.3.3. Low Level Controller (LICL-506) is provided.
1.4.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
1.4.2. PSV-500 is provided.
1.4.3. V-432 vent valve is provided.
1.4.4. SDV-504 is provided.
1.4.5. High Pressure Controller (PICH-505) is provided.
1.5.1. High-High Temperature Alarm and Trip System (TZAHH505) is
provided.
1.5.2. SDV-504 is provided.
1.5.3. SDV-506 is provided.
1.5.4. V-420 Drain Valve is provided.
1.5.5. High Temperature Controller Alarm (TICAH-507) is provided.
HAZOP Worksheets

1 3 2 2. FV-502 malfunction partially closed Refer to item less flow above (1.1) Refer to item less flow above (1.1.1) N/A Consultant
Refer to item less flow above (1.1.2)
Refer to item less flow above (1.1.3)
Refer to item less flow above (1.1.4)
Refer to item less flow above (1.1.5)
Refer to item less flow above (1.1.6)
1 3 3 3. M-503 malfunction Refer to item less flow above (1.2) Refer to item less flow above (1.2.1) Refer to recommendations No Flow above (4, 5). Consultant
Refer to item less flow above (1.3) Refer to item less flow above (1.2.2)
Refer to item less flow above (1.4) Refer to item less flow above (1.2.3)
Refer to item less flow above (1.5) Refer to item less flow above (1.2.4)
Refer to item less flow above (1.3.1)
Refer to item less flow above (1.3.2)
Refer to item less flow above (1.3.3)
Refer to item less flow above (1.4.1)
Refer to item less flow above (1.4.2)
Refer to item less flow above (1.4.3)
Refer to item less flow above (1.4.4)
Refer to item less flow above (1.4.5)
Refer to item less flow above (1.5.1)
Refer to item less flow above (1.5.2)
Refer to item less flow above (1.5.3)
Refer to item less flow above (1.5.4)
Refer to item less flow above (1.5.5)

1 3 4 4. TV-504 malfunction partially closed 4.1 Less Flow of utility stream from E- 4.2.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided. Refer to recommendation No Flow above (8). Consultant
500, leading to potential low 4.2.2. SDV-505 is provided.
temperature of E-500. 4.2.3. V-422 drain valve is provided.
4.2 Less Flow of hot water utility stream 4.2.4. Low Temperature Controller Alarm (TICAL-507) is provided.
from E-500, leading to potential low
temperature of R-500.
1 3 5 5. PV-505 malfunction partially closed 5.1 Less top outlet flow from R-500, Refer to item less flow above (1.4.1) N/A Consultant
leading to potential high pressure in R- Refer to item less flow above (1.4.2)
500. Refer to item less flow above (1.4.3)
Refer to item less flow above (1.4.4)
Refer to item less flow above (1.4.5)
1 3 6 6. LV-506 malfunction partially closed 6.1 Less Flow from R-500, leading to 6.1.1. High-High Level Alarm and Trip System (LZAHH506) is provided. N/A Consultant
potential high level in R-500. 6.1.2. SDV-506 is provided.
6.2 High level in R-500, leading to 6.1.3. V-425 drain valve is provided.
potential low pressure in R-500. 6.1.4. Low Flow Indicator and Alarm (FIAL-508) is provided.
6.1.5. High Level Controller (LICH-506) is provided.
6.2.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
6.2.2. SDV-507 is provided.
6.2.3. Low Pressure Controller (PICL-505) is provided.

1 3 7 7. TV-507 malfunction partially closed 7.1 Less Flow of utility stream from R- Refer to item less flow above (1.2.1) N/A Consultant
500, leading to potential high Refer to item less flow above (1.2.2)
temperature of R-500. Refer to item less flow above (1.2.3)
Refer to item less flow above (1.2.4)

1 4 1 Reverse Flow 1. V-525 malfunction closed 1.1. More water accumulation at outlet 1.1.1. PM-503 is provided. Refer to recommendation No Flow above (6, 7) Consultant
of P-500 will flow back through the 1.1.2. I-503 is provided.
recycle stream leading to damaged 1.1.3. Drain valve of P-500 is provided.
pump. 1.1.4. V-398 drain valve is provided.
1 4 2 2. TV-504 malfunction closed 2.1. Reverse Flow to E-500, leading to 2.1.1. V-414 bypass valve is provided. Refer to recommendation No Flow above (8) Consultant
potential low temperature of E-500. 2.2.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided.
2.2. No Flow of Hot water utility stream 2.2.2. SDV-505 is provided.
from E-500, leading to potential low 2.2.3. V-422 drain valve is provided.
temperature of R-500. 2.2.4. Low Temperature Controller Alarm (TICAL-507) is provided.
1 4 3 3. SDV-506 malfunction closed 3.1. Reverse Flow to E-500, leading to 3.1.1. High Temperature Controller (TICH-504) is provided. 13. Consider to install a reverse valve at E-500 stream Consultant
potential high temperature in tube side 3.1.2. V-417 drain valve is provided. outlet.
of E-500. 14. Consider to add Alarm at Temperature Indicator
Controller (TIC-504) to alert operator.
15. Consider to install a Temperature Emergency Trip
System at tube side of E-500.
HAZOP Worksheets

1 4 4 4. PV-505 malfunction closed. 4.1 Reverse Flow to R-500, leading to 4.1.1. High-High Pressure Alarm and Trip System (PZAHH504) is provided. Refer to recommendation No Flow above (3) Consultant
potential high pressure in R-500. 4.1.2. SDV-504 is provided. 16. Consider to install reverse valve at top vapor stream
4.2 High Pressure of R-500, leading to 4.1.3. PSV-500 is provided. outlet of R-500 for protection purpose before V-432.
potential reverse flow of inlet water 4.1.4. V-432 Vent Valve is provided.
stream. 4.1.5. High Pressure Controller (PICH-505) is provided.
4.3 Reverse flow of R-500 inlet water 4.3.1. High-High-High Temperature Alarm and Trip System (TZAHH503) is
stream to E-500, leading to potential high provided.
temperature of E-500. 4.3.2. SDV-503 is provided.
4.3.3. V-417 Drain Valve is provided.
4.3.4. High Temperature Controller (TICH-504) is provided.

1 4 5 5. SDV-507 malfunction closed Refer to item no. 1.4.4 Refer to item no. 1.4.4 Refer to recommendation No Flow above (3) Consultant
Refer to recommendation Reverse Flow above (16).
1 4 6 6. TV-507 malfunction closed 6.1. Reverse Flow to R-500, leading to Refer to item reversed flow above (4.3.1) 17. Consider to install reverse valve at utility stream Consultant
potential high temperature in R-500. Refer to item reversed flow above (4.3.2) outlet of R-500 for protection purpose before V-439.
Refer to item reversed flow above (4.3.3)
Refer to item reversed flow above (4.3.4)

1 4 7 7. LV-506 malfunction closed 7.1. Reverse Flow to R-500, leading to 7.1.1. High-High Level Alarm and Trip System (LZAHH506) is provided. Refer to recommendation More Flow above (12) Consultant
potential high level in R-500 7.1.2. SDV-506 is provided.
7.2. High level in R-500, leading to 7.1.3. V-425 drain valve is provided.
potential low pressure in R-500. 7.1.4. Low Flow Alarm (FIAL-508) is provided.
7.1.5. High Level Controller (LICH-506) is provided.
7.2.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
7.2.2. SDV-507 is provided.
7.2.3. Low Pressure Controller (PICL-505) is provided.

1 4 8 8. SDV-508 malfunction closed Refer to item no. 1.4.7 Refer to item no. 1.4.7 Refer to recommendation More Flow above (12) Consultant

1 5 1 High Pressure 1. SDV-501 malfunction closed 1.1. No Flow to P-500, leading to break 1.1.1. Low-Low Flow Alarm and Trip System (FZALL501) is provided. Refer to recommendation No Flow above (1, 2, 3). Consultant
down of P-500 due to pump minimum 1.1.2. SDV-502 is provided.
flow. 1.1.3. PM-503 is provided.
1.2. No Flow of water leading to 1.1.4. I-503 is provided.
potential high temperature in E-500. 1.1.5. Low Flow Controller Alarm (FICAL-503) is provided.
1.3. Loss of production due to no flow of 1.2.1. High-High Temperature Alarm and Trip System (TZAHH503) is
water flowing into R-500. provided.
1.4. No Flow of water to R-500, leading to 1.2.2. SDV-503 is provided.
potential high pressure in R-500. 1.2.3. V-408 drain valve is provided.
1.2.4. Low Temperature Controller (TICL-504) is provided.
1.3.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
1.3.2. SDV-508 is provided.
1.3.3. Low Level Controller (LICL-506) is provided.
1.4.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
1.4.2. SDV-504 is provided.
1.4.3. PSV-500 is provided.
1.4.4. V-432 vent valve is provided.
1.4.5. High Pressure Controller (PICH-505) is provided.

1 5 2 2. FV-501 malfunction closed Refer to item no. 1.5.1. Refer to item no. 1.5.1. Refer to recommendation No Flow above (1, 2, 3). Consultant
HAZOP Worksheets

1 5 3 3. FV-501 malfunction partially closed 3.1. Less Flow to P-500, leading to break Refer to item high pressure above 1.1.1. Refer to recommendation No Flow above (1, 2, 3). Consultant
down of P-500 due to pump minimum Refer to item high pressure above 1.1.2.
flow. Refer to item high pressure above 1.1.3.
3.2. Less Flow of water leading to Refer to item high pressure above 1.1.4.
potential high temperature in E-500. 3.1.1. Low Flow Controller (FICL-502) is provided.
3.3. Loss of production due to less flow 3.1.2. High Flow Controller Alarm (FICAL-503) is provided.
of water flowing into R-500. Refer to item high pressure above 1.2.1.
3.4. Less Flow to R-500, leading to Refer to item high pressure above 1.2.2.
potential high pressure in R-500. Refer to item high pressure above 1.2.3.
3.5. Less water flow of high temperature 3.2.1. High Temperature Controller (TICH-504) is provided.
water to R-500, leading to high Refer to item high pressure above 1.3.1.
temperature in R-500. Refer to item high pressure above 1.3.2.
Refer to item high pressure above 1.3.3.
Refer to item high pressure above 1.4.1.
Refer to item high pressure above 1.4.2.
Refer to item high pressure above 1.4.3.
Refer to item high pressure above 1.4.4.
Refer to item high pressure above 1.4.5.
3.5.1. High-High Temperature Alarm and Trip System (TZAHH505) is
provided.
3.5.2. SDV-504 is provided.
3.5.3. SDV-506 is provided.
3.5.4. V-420 Drain Valve is provided.
3.5.5. High Temperature Controller Alarm (TICAH-507) is provided.

1 5 4 4. M-503 malfunction Refer to item high pressure above (1.2) Refer to item high pressure above (1.2.1) Refer to recommendation No Flow above (4, 5). Consultant
Refer to item high pressure above (1.3) Refer to item high pressure above (1.2.2)
Refer to item high pressure above (1.4) Refer to item high pressure above (1.2.3)
Refer to item high pressure above (3.2) Refer to item high pressure above (1.2.4)
Refer to item high pressure above (3.3) Refer to item high pressure above (1.3.1)
Refer to item high pressure above (3.4) Refer to item high pressure above (1.3.2)
Refer to item high pressure above (3.5) Refer to item high pressure above (1.3.3)
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)
Refer to item high pressure above (3.2.1)
Refer to item high pressure above (3.5.1)
Refer to item high pressure above (3.5.2)
Refer to item high pressure above (3.5.3)
Refer to item high pressure above (3.5.4)
Refer to item high pressure above (3.5.5)

1 5 5 5. V-525 malfunction closed Refer to item high pressure above (1.2) Refer to item high pressure above (1.2.1) Refer to recommendation No Flow above (6, 7) Consultant
Refer to item high pressure above (1.3) Refer to item high pressure above (1.2.2)
Refer to item high pressure above (1.4) Refer to item high pressure above (1.2.3)
5.1. More water accumulation at outlet Refer to item high pressure above (1.2.4)
of P-500 will flow back through the Refer to item high pressure above (1.3.1)
recycle stream leading to damaged Refer to item high pressure above (1.3.2)
pump. Refer to item high pressure above (1.3.3)
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)
5.1.1. PM-501 is provided
5.1.2. I-503 is provided
5.1.3. Drain valve of P-500 is provided.
5.1.4. V-398 drain valve is provided.
HAZOP Worksheets

1 5 6 6. SDV-502 malfunction closed Refer to item high pressure above (1.2) Refer to item high pressure above (1.2.1) Refer to recommendation No Flow above (1, 2, 3) Consultant
Refer to item high pressure above (1.3) Refer to item high pressure above (1.2.2)
Refer to item high pressure above (1.4) Refer to item high pressure above (1.2.3)
Refer to item high pressure above (1.2.4)
Refer to item high pressure above (1.3.1)
Refer to item high pressure above (1.3.2)
Refer to item high pressure above (1.3.3)
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)

1 5 7 7. TV-504 malfunction stuck opened 7.1 More Flow of utility stream from E- 7.1.1. High-High Temperature Alarm and Trip System (TZAHH503) is Refer to recommendation No Flow above (2) Consultant
500, leading to potential high provided. Refer to recommendation More Flow above (11)
temperature of E-500. 7.1.2. SDV-503 is provided.
7.2 More Flow of utility stream from E- 7.1.3. V-408 drain valve is provided.
500, leading to potential high 7.2.1. High-High Temperature Alarm and Trip System (TZAHH505) is
temperature of R-500 due to high provided.
temperature water stream. 7.2.2. SDV-504 is provided.
7.3 More vapour is generated due to high 7.2.3. SDV-506 is provided.
temperature, leading to high pressure in 7.2.4. V-420 drain valve is provided.
R-500. 7.2.5. High Temperature Controller Alarm (TICAH-507) is provided.
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)

1 5 8 8. SDV-505 malfunction closed 9.1. No flow of coolant leads to potential 9.1.1. High-High Temperature Alarm and Trip System (TZAHH505) is Refer to recommendation No Flow above (2) Consultant
loss of cooling, possible thermal runaway provided.
and leading to decrease of reaction rate. 9.1.2. SDV-504 is provided.
Refer to item high pressure above (7.3) 9.1.3. SDV-506 is provided.
9.1.4. V-420 Drain Valve is provided
9.1.5. High Temperature Controller Alarm (TICAH-507) is provided.
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)

1 5 9 9. SDV-506 malfunction closed 9.1. No Flow of water leading to 9.1.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided. Refer to recommendation No Flow above (2) Consultant
potential low temperature in R-500. 9.1.2. SDV-505 is provided.
Refer to item high pressure above (1.3) 9.1.3. V-422 drain valve is provided.
Refer to item high pressure above (1.4) Refer to item high pressure above (1.3.1)
Refer to item high pressure above (1.3.2)
Refer to item high pressure above (1.3.3)
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)

1 5 10 10. PV-505 malfunction closed 11.1 Reverse Flow to R-500 and No Flow Refer to item high pressure above (1.4.1) Refer to recommendation No Flow above (3) Consultant
from R-500, leading to potential high Refer to item high pressure above (1.4.2) Refer to recommendation Reverse Flow above (16)
pressure in R-500. Refer to item high pressure above (1.4.3)
11.2 High Pressure of R-500, leading to Refer to item high pressure above (1.4.4)
potential reverse flow of inlet water 11.3.1. High-High-High Temperature Alarm and Trip System (TZAHH505) is
stream. provided.
11.3 Reverse flow of R-500 inlet water 11.3.2. SDV-504 is provided.
stream to E-500, leading to potential high 11.3.3. SDV-506 is provided.
temperature of E-500. 11.3.4. V-439 Drain Valve is provided.

1 5 11 11. SDV-507 malfunction closed Refer to item no. 1.5.10. Refer to item no. 1.5.10. Refer to recommendation No Flow above (3) Consultant
Refer to recommendation Reverse Flow above (16)
1 5 12 12. PV-505 malfunction partially 12.1 Less top outlet flow from R-500, Refer to item high pressure above (1.4.1) N/A Consultant
closed leading to potential high pressure in R- Refer to item high pressure above (1.4.2)
500. Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)
HAZOP Worksheets

1 5 13 13. LV-506 malfunction stuck opened 13.1 More flow from R-500, leading to 5.1.1. High Flow Indicator and Alarm (FIAH-508) is provided. N/A Consultant
potential low level in R-500. Refer to item high pressure above (1.3.1)
13.2 Low level in R-500, leading to Refer to item high pressure above (1.3.2)
potential high pressure in R-500. Refer to item high pressure above (1.3.3)
Refer to item high pressure above (1.4.1)
Refer to item high pressure above (1.4.2)
Refer to item high pressure above (1.4.3)
Refer to item high pressure above (1.4.4)
Refer to item high pressure above (1.4.5)

1 6 1 Low Pressure 1. FV-501 malfunction stuck opened 1.1. More water flow to P-500, leading to 1.1.1. High-High Flow Alarm and Trip System (FZAHH502) is provided. Refer to recommendation No Flow above (7,8) Consultant
break down of P-500 due to pump 1.1.2. SDV-501 is provided. Refer to recommendation More Flow above (10)
maximum flow. 1.1.3. SDV-502 is provided.
1.2. More water flow leading to potential 1.1.4. V-398 Drain Valve is provided.
low temperature in E-500. 1.1.5. PM-503 is provided.
1.3. More water flow to R-500, lead to 1.1.6. I-503 is provided.
potential flooding and damage of tray in 1.1.7. High Flow Controller (FICH-502) is provided.
R-500. 1.1.8. High Flow Controller Alarm (FICAH-503) is provided.
1.4. More water flow to R-500, leading to 1.2.1. V-407 Drain Valve is provided.
potential low pressure in R-500. 1.2.2. Low Temperature Controller (TICL-504) is provided.
1.5. More water flow of low temperature 1.3.1. High-High Level Alarm and Trip System (LZAHH506) is provided.
water to R-500, leading to low 1.3.2. SDV-506 is provided.
temperature in R-500. 1.3.3. V-420 Drain Valve is provided.
1.3.4. High Level Controller (LIC-506) is provided.
1.4.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
1.4.2. SDV-507 is provided.
1.4.3. Low Pressure Controller (PICL-505) is provided.
1.5.1. Low-Low Temperatur Alarm and Trip System (TZALL505) is provided.
1.5.2. SDV-505 is provided.
1.5.3. V-422 Drain Valve is provided.
1.5.4. Low Temperature Controller Alarm (TICAL-507) is provided.

1 6 2 2. M-503 malfunction 2.1. Low pressure in P-500 outlet, 2.1.1. High-High Temperature Alarm and Trip System (TZAHH503) is Refer to recommendations No Flow above (4, 5). Consultant
leading to less flowrate of water and provided.
potential high temperature to E-500. 2.1.2. SDV-503 is provided.
2.2. Loss of production due to less flow 2.1.3. V-408 drain valve is provided.
of water flowing into R-500. 2.1.4. High Temperature Controller (TICH504) is provided.
2.3. Less Water Flow to R-500, leading to 2.2.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
potential high pressure in R-500. 2.2.2. SDV-508 is provided.
2.4. Less water flow of high temperature 2.2.3. Low Level Controller (LICL-506) is provided.
water to R-500, leading to high 2.3.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
temperature in R-500. 2.3.2. PSV-500 is provided.
2.3.3. V-432 vent valve is provided.
2.3.4. SDV-504 is provided.
2.3.5. High Pressure Controller (PICH-505) is provided.
2.4.1. High-High Temperature Alarm and Trip System (TZAHH505) is
provided.
2.4.2. SDV-504 is provided.
2.4.3. SDV-506 is provided.
2.4.4. V-420 Drain Valve is provided.
2.4.5. High Temperature Controller Alarm (TICAH-507) is provided.

1 6 3 3. SDV-504 malfunction closed 3.1. No Flow of gas leading to potential 3.1.1. Low Temperature Controller Alarm (TICAL-507) is provided. Refer to recommendation No Flow above (9). Consultant
low temperature in R-500. 3.2.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided.
3.2. Loss of production due to no flow of 3.2.2. SDV-505 is provided.
process gas into R-500. 3.2.3. V-422 drain valve is provided.
3.3. No Flow of process gas to R-500, 3.3.1. Low-low Pressure Alarm and Trip System (PZALL504) is provided.
leading to potential low pressure in R- 3.3.2. SDV-507 is provided.
500. 3.3.3. Low Pressure Controller (PICL-505) is provided.

1 6 4 4. V-526 malfunction closed Refer to item no. 1.6.4 Refer to item no. 1.6.4 Refer to recommendation No Flow above (9). Consultant
HAZOP Worksheets

1 6 5 5. PV-505 malfuntion stuck opened 5.1 More vapor flow exit from R-500, 5.1.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided. Refer to recommendation No Flow above (2). Consultant
leading to potential low pressure in R- 5.1.2. SDV-507 is provided. Refer to recommendation More Flow above (12).
500. 5.1.3. Low Pressure Controller (PICL-505) is provided.
5.2 Low Pressure of R-500, leading to Refer to low pressure above (1.3.1).
potential reverse flow of bottom liquid Refer to low pressure above (1.3.2).
outlet stream. Refer to low pressure above (1.3.3).
5.3. Reverse Flow of bottom liquid outlet 5.3.1. V-425 drian valve is provided.
stream, leading to potential high level in
R-500.
1 6 6 6. LV-506 malfunction closed 6.1. Reverse Flow to R-500 and No Outlet 6.1.1. High-High Level Alarm and Trip System (LZAHH506) is provided. Refer to recommendation More Flow above (12). Consultant
Flow from R-500, leading to potential 6.1.2. SDV-506 is provided.
high level in R-500 6.1.3. V-425 drain valve is provided.
6.2. High level in R-500, leading to 6.1.4. Low Flow Alarm (FIAL-508) is provided.
potential low pressure in R-500. 6.1.5. High Level Controller (LICH-506) is provided.
Refer to item low pressure above (5.1.1).
Refer to item low pressure above (5.1.2).
Refer to item low pressure above (5.1.3).

1 6 7 7. LV-506 malfunction partially closed 7.1 Less Flow from R-500, leading to Refer to item no. 1.6.6 Refer to recommendation More Flow above (12). Consultant
potential high level in R-500.
7.2 High level in R-500, leading to
potential low pressure in R-500.
1 6 8 8. SDV-508 malfunction closed Refer to item no. 1.6.6 Refer to item no. 1.6.6 Refer to recommendation More Flow above (12). Consultant

1 7 1 High Temperature 1. SDV-501 malfunction closed 1.1. No Flow to P-500, leading to break 1.1.1. Low-Low Flow Alarm and Trip System (FZALL501) is provided. Refer to recommendation No Flow above (1, 2, 3) Consultant
down of P-500 due to pump minimum 1.1.2. SDV-502 is provided.
flow. 1.1.3. PM-503 is provided.
1.2. No Flow of water leading to 1.1.4. I-503 is provided.
potential high temperature in E-500. 1.1.5. Low Flow Controller Alarm (FICAL-503) is provided.
1.3. Loss of production due to no flow of 1.2.1. High-High Temperature Alarm and Trip System (TZAHH503) is
water flowing into R-500. provided.
1.4. No Flow of water to R-500, leading to 1.2.2. SDV-503 is provided.
potential high pressure in R-500. 1.2.3. V-408 drain valve is provided.
1.2.4. Low Temperature Controller (TICL-504) is provided.
1.3.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
1.3.2. SDV-508 is provided.
1.3.3. Low Level Controller (LICL-506) is provided.
1.4.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
1.4.2. SDV-504 is provided.
1.4.3. PSV-500 is provided.
1.4.4. V-432 vent valve is provided.
1.4.5. High Pressure Controller (PICH-505) is provided.

1 7 2 2. FV-501 malfunction closed Refer to item no. 1.7.1. Refer to item no. 1.7.1. Refer to recommendation No Flow above (1, 2, 3) Consultant
1 7 3 3. FV-501 malfunction partially closed 3.1. Less Flow to P-500, leading to break Refer to item high temperature above (1.1.1). Refer to recommendation No Flow above (1, 2, 3) Consultant
down of P-500 due to pump minimum Refer to item high temperature above (1.1.2).
flow. Refer to item high temperature above (1.1.3).
3.2. Less Flow of water leading to Refer to item high temperature above (1.1.4).
potential high temperature in E-500. Refer to item high temperature above (1.1.5).
3.3. Loss of production due to less flow 3.1.1. High Flow Controller Alarm (FICAL-503) is provided.
of water flowing into R-500. Refer to item high temperature above (1.2.1).
3.4. Less Flow to R-500, leading to Refer to item high temperature above (1.2.2).
potential high pressure in R-500. Refer to item high temperature above (1.2.3).
3.5. Less water flow of high temperature Refer to item high temperature above (1.2.4).
water to R-500, leading to high Refer to item high temperature above (1.3.1).
temperature in R-500. Refer to item high temperature above (1.3.2).
Refer to item high temperature above (1.3.3).
Refer to item high temperature above (1.4.1).
Refer to item high temperature above (1.4.2).
Refer to item high temperature above (1.4.3).
Refer to item high temperature above (1.4.4).
Refer to item high temperature above (1.4.5).
3.5.1. High-High Temperature Alarm and Trip System (TZAHH505) is
provided.
3.5.2. SDV-504 is provided.
3.5.3. SDV-506 is provided.
3.5.4. V-420 Drain Valve is provided.
3.5.5. High Temperature Controller Alarm (TICAH-507) is provided.
HAZOP Worksheets

1 7 4 4. M-503 malfunction 4.1. No Flow and less flow of water Refer to item high temperature above (1.2.1). Refer to recommendation No Flow above (4, 5) Consultant
leading to potential high temperature in Refer to item high temperature above (1.2.2).
E-500. Refer to item high temperature above (1.2.3).
4.2. Loss of production due to no flow of Refer to item high temperature above (1.2.4).
water flowing into R-500. 4.1.1. High Temperature Controller (TICH-504) is provided.
4.3. No Flow and less flow of water to R- Refer to item high temperature above (1.3.1).
500, leading to potential high pressure in Refer to item high temperature above (1.3.2).
R-500. Refer to item high temperature above (1.3.3).
4.4. Less water flow of high temperature Refer to item high temperature above (1.4.1).
water to R-500, leading to high Refer to item high temperature above (1.4.2).
temperature in R-500. Refer to item high temperature above (1.4.3).
Refer to item high temperature above (1.4.4).
Refer to item high temperature above (1.4.5).
4.4.1. High-High Temperature Alarm and Trip System (TZAHH505) is
provided.
4.4.2. SDV-504 is provided.
4.4.3. SDV-506 is provided.
4.4.4. V-420 Drain Valve is provided.
4.4.5. High Temperature Controller Alarm (TICAH-507) is provided.

1 7 5 5. V-525 malfunction closed Refer to item high temperature above Refer to item high temperature above (1.2.1). Refer to recommendation No Flow above (6, 7) Consultant
(1.2) Refer to item high temperature above (1.2.2).
Refer to item high temperature above Refer to item high temperature above (1.2.3).
(1.3) Refer to item high temperature above (1.2.4).
Refer to item high temperature above Refer to item high temperature above (1.3.1).
(1.4) Refer to item high temperature above (1.3.2).
Refer to item high temperature above (1.3.3).
Refer to item high temperature above (1.4.1).
Refer to item high temperature above (1.4.2).
Refer to item high temperature above (1.4.3).
Refer to item high temperature above (1.4.4).
Refer to item high temperature above (1.4.5).

1 7 6 6. SDV-502 malfunction closed Refer to item no. 1.7.5 Refer to item no. 1.7.5 Refer to recommendation No Flow above (1, 2, 3) Consultant
1 7 7 7. TV-504 malfunction stuck opened 7.1 More Flow of utility stream from E- Refer to item high temperature above (1.2.1). Refer to recommendation No Flow above (2) Consultant
500, leading to potential high Refer to item high temperature above (1.2.2). Refer to recommendation More Flow above (11)
temperature of E-500. Refer to item high temperature above (1.2.3).
7.2 More Flow of utility stream from E- Refer to item high temperature above (3.5.1).
500, leading to potential high Refer to item high temperature above (3.5.2).
temperature of R-500 due to high Refer to item high temperature above (3.5.3).
temperature water stream. Refer to item high temperature above (3.5.4).
7.3 More vapour is generated due to high Refer to item high temperature above (3.5.5).
temperature, leading to high pressure in Refer to item high temperature above (1.4.1).
R-500. Refer to item high temperature above (1.4.2).
Refer to item high temperature above (1.4.3).
Refer to item high temperature above (1.4.4).
Refer to item high temperature above (1.4.5).

1 7 8 8. SDV-505 malfunction closed 8.1. No flow of coolant leads to potential Refer to item high temperature above (4.4.1). Refer to recommendation No Flow above (2) Consultant
loss of cooling, possible thermal Refer to item high temperature above (4.4.2).
runaway of R-500 and leading to Refer to item high temperature above (4.4.3).
decrease of reaction rate. Refer to item high temperature above (4.4.4).
8.2. More vapour is generated due to Refer to item high temperature above (4.4.5).
high temperature, leading to high Refer to item high temperature above (1.4.1)
pressure in R-500. Refer to item high temperature above (1.4.2)
Refer to item high temperature above (1.4.3)
Refer to item high temperature above (1.4.4)
Refer to item high temperature above (1.4.5)

1 7 9 9. SDV-506 malfunction closed 9.1. Reverse Flow to E-500, leading to 9.1.1. High Temperature Controller (TICH-504) is provided. Refer to recommendation Reverse Flow above (13, 14, Consultant
potential high temperature in tube side 9.1.2. V-417 drain valve is provided. 15)
of E-500.
HAZOP Worksheets

1 7 10 10. PV-505 malfunction closed 10.1 Reverse Flow to R-500 and No Refer to item high temperature above (1.4.1). Refer to recommendation No Flow above (3) Consultant
Outlet Flow of R-500, leading to potential Refer to item high temperature above (1.4.2). Refer to recommendation Reverse Flow above (16)
high pressure in R-500. Refer to item high temperature above (1.4.3).
10.2 High Pressure of R-500, leading to Refer to item high temperature above (1.4.4).
potential reverse flow of inlet water Refer to item high temperature above (1.4.5).
stream. 10.3.1. High-High-High Temperature Alarm and Trip System (TZAHH503) is
10.3 Reverse flow of R-500 inlet water provided.
stream to E-500, leading to potential high 10.3.2. SDV-503 is provided.
temperature of E-500. 10.3.3. V-417 Drain Valve is provided.
10.3.4. High Temperature Controller (TICH-504) is provided.

1 7 11 11. SDV-507 malfunction closed Refer to item no. 1.7.10 Refer to item no. 1.7.10 Refer to recommendation No Flow above (3) Consultant
Refer to recommendation Reverse Flow above (16).
1 7 12 12. TV-507 malfunction closed 12.1. Reverse Flow of coolant to R-500, Refer to item high temperature above (10.3.1) Refer to recommendation Reverse Flow above (17). Consultant
leading to potential high temperature in Refer to item high temperature above (10.3.2)
R-500. Refer to item high temperature above (10.3.3)
Refer to item high temperature above (10.3.4)

1 7 13 13. TV-507 malfunction partially 13.1 Less Flow of utility stream from R- Refer to item high temperature above (1.2.1) N/A Consultant
closed 500, leading to potential high Refer to item high temperature above (1.2.2)
temperature of R-500. Refer to item high temperature above (1.2.3)
Refer to item high temperature above (10.3.4)

1 8 1 Low Temperature 1. FV-501 malfunction stuck opened 1.1. More water flow to P-500, leading to 1.1.1. High-High Flow Alarm and Trip System (FZAHH502) is provided. Refer to recommendation No Flow above (7,8) Consultant
break down of P-500 due to pump 1.1.2. SDV-501 is provided. Refer to recommendation More Flow above (10)
maximum flow. 1.1.3. SDV-502 is provided.
1.2. More water flow leading to potential 1.1.4. V-398 Drain Valve is provided.
low temperature in E-500. 1.1.5. PM-503 is provided.
1.3. More water flow to R-500, lead to 1.1.6. I-503 is provided.
potential flooding and damage of tray in 1.1.7. High Flow Controller (FICH502) is provided.
R-500. 1.1.8. High Flow Controller Alarm (FICAH503) is provided.
1.4. More water flow to R-500, leading to 1.2.1. V-407 Drain Valve is provided.
potential low pressure in R-500. 1.2.2. Low Temperature Controller (TICL-504) is provided.
1.5. More water flow of low temperature 1.3.1. High-High Level Alarm and Trip System (LZAHH506) is provided.
water to R-500, leading to low 1.3.2. SDV-506 is provided.
temperature in R-500. 1.3.3. V-420 Drain Valve is provided.
1.3.4. High Level Controller (LIC-506) is provided.
1.4.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
1.4.2. SDV-507 is provided.
1.4.3. Low Pressure Controller (PICL-505) is provided.
1.5.1. Low-Low Temperatur Alarm and Trip System (TZALL505) is provided.
1.5.2. SDV-505 is provided.
1.5.3. V-422 Drain Valve is provided.
1.5.4. Low Temperature Controller Alarm (TICAL-507) is provided.

1 8 2 2. SDV-503 malfunction closed 2.1. Potential loss of heating leading to Refer to item Low temperature above (1.5.1) Refer to recommendation No Flow above (8). Consultant
potential low temperature of E-500. Refer to item Low temperature above (1.5.2)
2.2. Less temperature water inlet of R- Refer to item Low temperature above (1.5.3)
500, leading to decrease reaction rate. Refer to item Low temperature above (1.5.4)

1 8 3 3. TV-504 malfunction closed 3.1. Reverse Flow to E-500, leading to 3.1.1. V-414 bypass valve is provided. Refer to recommendation No Flow above (8) Consultant
potential low temperature of E-500. Refer to item Low temperature above (1.5.1)
3.2. No Flow of Hot water utility stream Refer to item Low temperature above (1.5.2)
from E-500, leading to potential low Refer to item Low temperature above (1.5.3)
temperature of R-500. Refer to item Low temperature above (1.5.4)

1 8 4 4. TV-504 malfunction partially closed 4.1. Less Flow of utility stream from E- Refer to item Low temperature above (3.1.1) Refer to recommendation No Flow above (8). Consultant
500, leading to potential low Refer to item Low temperature above (1.5.1)
temperature of E-500. Refer to item Low temperature above (1.5.2)
4.2. Less Flow of hot water utility stream Refer to item Low temperature above (1.5.3)
from E-500, leading to potential low Refer to item Low temperature above (1.5.4)
temperature of R-500.
HAZOP Worksheets

1 8 5 5. SDV-504 malfunction closed 5.1. No Flow of gas leading to potential Refer to item Low temperature above (1.5.1) Refer to recommendation No Flow above (9). Consultant
low temperature in R-500. Refer to item Low temperature above (1.5.2)
5.2. Loss of production due to no flow of Refer to item Low temperature above (1.5.3)
process gas into R-500. Refer to item Low temperature above (1.5.4)
5.3. No Flow of process gas to R-500, 5.3.1. Low-low Pressure Alarm and Trip System (PZALL504) is provided.
leading to potential low pressure in R- 5.3.2. SDV-507 is provided.
500. 5.3.3. Low Pressure Controller (PICL-505) is provided.

1 8 6 6. V-526 malfunction closed Refer to item no. 1.8.5 Refer to item no. 1.8.5 Refer to recommendation No Flow above (9). Consultant
1 8 7 7. SDV-506 malfunction closed 7.1. No Flow of water leading to 7.1.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided. Refer to recommendation No Flow above (2) Consultant
potential low temperature in R-500. 7.1.2. SDV-505 is provided.
Refer to item low temperature above 7.1.3. V-422 drain valve is provided.
(5.2) 7.1.4. Low Temperature Controller Alarm (TICAL-507) is provided.
Refer to item low temperature above 7.1.5. Low-Low Level Alarm and Trip System (LZALL506) is provided.
(5.3) 7.1.6. SDV-508 is provided.
7.1.7. Low Level Controller (LICL-506) is provided.
7.1.8. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
7.1.9. SDV-504 is provided.
7.1.10. PSV-500 is provided.
7.1.11. V-432 vent valve is provided.
7.1.12. High Pressure Controller (PICH-505) is provided.

1 8 8 8. TV-507 malfunction stuck opened 8.1. More Flow of utility stream from R- Refer to item Low temperature flow above (7.1.1) N/A Consultant
500, leading to potential low Refer to item Low temperature flow above (7.1.2)
temperature of R-500. Refer to item Low temperature flow above (7.1.3)
8.2 Low temperature of R-500 leading to Refer to item Low temperature flow above (7.1.4)
decrease of reaction rate.

1 9 1 No Level 1. SDV-501 malfunction closed 1.1. No Flow to P-500, leading to break 1.1.1. Low-Low Flow Alarm and Trip System (FZALL501) is provided. Refer to recommendation No Flow above (1,2,3) Consultant
down of P-500 due to pump minimum 1.1.2. SDV-502 is provided.
flow. 1.1.3. PM-503 is provided.
1.2. No Flow of water leading to 1.1.4. I-503 is provided.
potential high temperature in E-500. 1.1.5. Low Flow Controller Alarm FICAL-503 is provided.
1.3. Loss of production due to no flow of 1.2.1. High-High Temperature Alarm and Trip System (TZAHH503) is
water flowing into R-500, under no level provided.
in R-500. 1.2.2. SDV-503 is provided.
1.4. No Flow of water to R-500, leading to 1.2.3. V-408 drain valve is provided.
potential high pressure in R-500. 1.2.4. Low Temperature Controller (TICL-504) is provided.
1.3.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
1.3.2. SDV-508 is provided.
1.3.3. Low Level Controller (LICL-506) is provided.
1.4.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
1.4.2. SDV-504 is provided.
1.4.3. PSV-500 is provided.
1.4.4. V-432 vent valve is provided.
1.4.5. High Pressure Controller (PICH-505) is provided.

1 9 2 2. FV-501 malfunction closed Refer to item no. 1.9.1. Refer to item no. 1.9.1. Refer to recommendation No Flow above (1,2,3) Consultant
1 9 3 3. M-503 malfunction closed Refer to item no level above (1.2) Refer to item no level above (1.2.1) Refer to recommendation No Flow above (4,5) Consultant
Refer to item no level above (1.3) Refer to item no level above (1.2.2)
Refer to item no level above (1.4) Refer to item no level above (1.2.3)
Refer to item no level above (1.2.4)
Refer to item no level above (1.3.1)
Refer to item no level above (1.3.2)
Refer to item no level above (1.3.3)
Refer to item no level above (1.4.1)
Refer to item no level above (1.4.2)
Refer to item no level above (1.4.3)
Refer to item no level above (1.4.4)
Refer to item no level above (1.4.5)

1 9 4 4. V-525 malfunction closed Refer to item no. 1.9.3. Refer to item no. 1.9.3 Refer to recommendation No Flow above (6, 7) Consultant
1 9 5 5. SDV-502 malfunction closed Refer to item no. 1.9.3. Refer to item no. 1.9.3 Refer to recommendation No Flow above (1,2,3) Consultant
HAZOP Worksheets

1 9 6 6. SDV-506 malfunction closed 6.1 No Flow of water leading to potential 6.1.1. Low-Low Temperature Alarm and Trip System (TZALL505) is provided. Refer to recommendation No Flow above (2) Consultant
low temperature in R-500. 6.1.2. SDV-505 is provided.
Refer to item no level above (1.3) 6.1.3. V-422 drain valve is provided.
Refer to item no level above (1.4) 6.1.4. Low Temperature Controller Alarm (TICAL-507) is provided.
Refer to item no level above (1.3.1)
Refer to item no level above (1.3.2)
Refer to item no level above (1.3.3)
Refer to item no level above (1.4.1)
Refer to item no level above (1.4.2)
Refer to item no level above (1.4.3)
Refer to item no level above (1.4.4)
Refer to item no level above (1.4.5)

1 10 1 High Level 1. FV-501 malfunction stuck opened 1.1. More water flow to P-500, leading to 1.1.1. High-High Flow Alarm and Trip System (FZAHH502) is provided. Refer to recommendation No Flow above (7,8) Consultant
break down of P-500 due to pump 1.1.2. SDV-501 is provided. Refer to recommendation More Flow above (10)
maximum flow. 1.1.3. SDV-502 is provided.
1.2. More water flow leading to potential 1.1.4. V-398 Drain Valve is provided.
low temperature in E-500. 1.1.5. PM-503 is provided.
1.3. More water flow to R-500, lead to 1.1.6. I-503 is provided.
potential flooding and damage of tray in 1.1.7. High Flow Controller (FICH-502) is provided.
R-500. 1.1.8. High Flow Controller Alarm (FICAH-503) is provided.
1.4. More water flow to R-500, leading to 1.2.1. V-407 Drain Valve is provided.
potential low pressure in R-500. 1.2.2. Low Temperature Controller (TICL-504) is provided.
1.5. More water flow of low temperature 1.3.1. High-High Level Alarm and Trip System (LZAHH506) is provided.
water to R-500, leading to low 1.3.2. SDV-506 is provided.
temperature in R-500. 1.3.3. V-420 Drain Valve is provided.
1.3.4. High Level Controller (LIC-506) is provided.
1.4.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
1.4.2. SDV-507 is provided.
1.4.3. Low Pressure Controller (PICL-505) is provided.
1.5.1. Low-Low Temperatur Alarm and Trip System (TZALL505) is provided.
1.5.2. SDV-505 is provided.
1.5.3. V-422 Drain Valve is provided.
1.5.4. Low Temperature Controller Alarm (TICAL-507) is provided.

1 10 2 2. PV-505 malfunction stuck opened 2.1. More flow from R-500, leading to Refer to item high level above (1.4.1) Refer to recommendation No Flow above (2). Consultant
potential low pressure in R-500. Refer to item high level above (1.4.2) Refer to recommendation More Flow above (12).
2.2. Low Pressure of R-500, leading to Refer to item high level above (1.4.3)
potential reverse flow of bottom liquid 2.3.1. V-425 drain valve is provided.
outlet stream. Refer to item high level above (1.3.1)
2.3 Reverse Flow of bottom liquid outlet Refer to item high level above (1.3.2)
stream, leading to potential high level in Refer to item high level above (1.3.3)
R-500. Refer to item high level above (1.3.4)

1 10 3 3. LV-506 malfunction partially closed 3.1. Less Flow from R-500, leading to 3.1.1. High-High Level Alarm and Trip System (LZAHH506) is provided. N/A Consultant
potential high level in R-500. 3.1.2. SDV-506 is provided.
3.2. High level in R-500, leading to 3.1.3. V-425 drain valve is provided.
potential low pressure in R-500. 3.1.4. Low Flow Indicator Alarm (FIAL-508) is provided.
3.1.5. High Level Controller (LICH-506) is provided.
3.2.1. Low-Low Pressure Alarm and Trip System (PZALL504) is provided.
3.2.2. SDV-507 is provided.
3.2.3. Low Pressure Controller (PICL-505) is provided.

1 10 4 4. LV-506 malfunction closed 4.1. Reverse Flow to R-500, leading to Refer to item high level above (3.1.1) Refer to recommendation More Flow above (12). Consultant
potential high level in R-500 Refer to item high level above (3.1.2)
4.2. High level in R-500, leading to Refer to item high level above (3.1.3)
potential low pressure in R-500. Refer to item high level above (3.1.4)
Refer to item high level above (3.1.5)
Refer to item high level above (3.2.1)
Refer to item high level above (3.2.2)
Refer to item high level above (3.2.3)

1 10 5 5. SDV-508 malfunction closed Refer to item no. 1.10.4 Refer to item no. 1.10.4 Refer to recommendation More Flow above (12). Consultant
HAZOP Worksheets

1 11 1 Low Level 1. FV-501 malfunction partially closed 1.1. Less Flow to P-500, leading to break 1.1.1. Low-Low Flow Alarm and Trip System (FZALL501) is provided. Refer to recommendations No Flow above (1, 2,3). Consultant
down of P-500 due to pump minimum 1.1.2. SDV-502 is provided.
flow. 1.1.3. PM-503 is provided.
1.2. Less Flow of water leading to 1.1.4. I-503 is provided.
potential high temperature in E-500. 1.1.5. Low Flow Controller (FICL-502) is provided.
1.3. Under low level condition,leading to 1.1.6. Low Flow Controller Alarm (FICAL-503) is provided.
loss of production due to less flow of 1.2.1. High-High Temperature Alarm and Trip System (TZAHH503) is
water flowing into R-500. provided.
1.4. Less Flow to R-500, leading to 1.2.2. SDV-503 is provided.
potential high pressure in R-500. 1.2.3. V-408 drain valve is provided.
1.5. Less water flow of high temperature 1.2.4. High Temperature Controller (TICH-504) is provided.
water to R-500, leading to high 1.3.1. Low-Low Level Alarm and Trip System (LZALL506) is provided.
temperature in R-500. 1.3.2. SDV-508 is provided.
1.3.3. Low Level Controller (LICL-506) is provided.
1.4.1. High-high Pressure Alarm and Trip System (PZAHH504) is provided.
1.4.2. PSV-500 is provided.
1.4.3. V-432 vent valve is provided.
1.4.4. SDV-504 is provided.
1.4.5. High Pressure Controller (PICH-505) is provided.
1.5.1. High-High Temperature Alarm and Trip System (TZAHH505) is
provided.
1.5.2. SDV-504 is provided.
1.5.3. SDV-506 is provided.
1.5.4. V-420 Drain Valve is provided.
1.5.5. High Temperature Controller Alarm (TICAH-507) is provided.

1 11 2 2. M-503 malfunction partially closed Refer to item low level above (1.2) Refer to item low level above (1.2.1) Refer to recommendations No Flow above (4, 5). Consultant
Refer to item low level above (1.3) Refer to item low level above (1.2.2)
Refer to item low level above (1.4) Refer to item low level above (1.2.3)
Refer to item low level above (1.5) Refer to item low level above (1.2.4)
Refer to item low level above (1.3.1)
Refer to item low level above (1.3.2)
Refer to item low level above (1.3.3)
Refer to item low level above (1.4.1)
Refer to item low level above (1.4.2)
Refer to item low level above (1.4.3)
Refer to item low level above (1.4.4)
Refer to item low level above (1.4.5)
Refer to item low level above (1.5.1)
Refer to item low level above (1.5.2)
Refer to item low level above (1.5.3)
Refer to item low level above (1.5.4)
Refer to item low level above (1.5.5)

1 11 3 3. LV-506 malfunction stuck opened 3.1 More flow from R-500, leading to 3.1.1. Low-Low Level Alarm and Trip System (LZALL506) is provided. N/A Consultant
potential low level in R-500. 3.1.2. SDV-508 is provided.
3.2 Low level in R-500, leading to high 3.1.3. High Flow Indicator and Alarm (FIAH-508) is provided.
pressure in R-500. 3.1.4. Low Level Controller (LICL-506) is provided.
3.2.1. High-High Pressure Alarm and Trip System (PZAHH504) is provided.
3.2.2. SDV-504 is provided.
3.2.3. PSV-500 is provided.
3.2.4. V-432 vent valve is provided.
3.2.5. High Pressure Controller (PICH-505) is provided.