Grounding plate Velcro GV Grounding straps EB1 / EB2 / EB3


YSHIELD GmbH & Co. KG

YSHIELD
Am Schulplatz 2 Grounding plate with Self-adhesive grounding
94099 Ruhstorf silvered Velcro fastener for straps for shielding paints,
Germany all sewed products with a fleeces and nettings in the
Phone: 0049-8531-31713-0 counterpart. 1 Just push interior. 1 The glue on
Fax: 0049-(0)8531-31713-5 the Velcro fastener EB1 / EB3 is electrically
EMR - PROTECTION Email: info@yshield.com
Internet: www.yshield.com
strongly on the counter-
part. 2 Insert the plugs.
conductive. Therefore
the EB1 / EB3 can be
sticked under and on the
Grounding plug GP materials. Application
under and on nettings,
Grounding plug for fleeces to connect the limited width of material.
CEE-7/4* and CEE-7/7** With an adhesive force of 3 N/cm, it sticks
power sockets, see list relatively poor on difficult undergrounds (e.g.
Technical data sheet - Grounding below. 1 Open and plasterboards). Use a primer first! 2 The glue on
remove the screw of the EB2 is electrically non-conductive. Therefore
socket cover. 2 Only a the EB2 can be sticked only under the
Installation of a functional equipotential bonding is as follows: licensed electrician is materials. Application under shielding paints
allowed to put / screw this to bridge cracks in the underground. With an
grounding plug in a power adhesive force of 10 N/cm it sticks very well even
Main earthing terminal

Fuse box
outlet, see „Important on difficult undergrounds.
RCD L1 safety guidelines“! 3 To fix this plug permanently
40/ N Wall area 1 Wall area 2 Wall area 3 in the power socket, it can be screwed together
0,03A PE with the socket cover using the enclosed screw.
SB 4 Insert the plugs. Clip on the covering cap, that
serve as protection against an accidential unplug
of the cable.
Grounding plate Grounding strap
PE FEB
GW or GB EB1, EB2 Grounding plug GD
Grounding plug for
CEE-7/4* and CEE-7/7**
corresponding technical data sheets. 6 Insert power sockets, see list
Important safety guidelines the plugs. Clip on the covering cap, that serve below. 1 Only a licensed
as protection against an accidential unplug of electrician is allowed to
Large shielding measures with shielding mate- the cable. push this grounding plug
rials are no electrical equipment but „new con- into a power outlet, see
ductive parts“ according to IEV 826-03-03 or IEV „Important safety
195-06-11 and thereby a new method of DIN VDE Grounding plate Exterior GE guidelines“! 2 Put the 4
0100-100:2009-06. By connecting the material(s) mm plug in other
to the potential equalization they are inherent Grounding plate for
shielding paints for grounding components. For a canopy you need The grounding straps must be pressed down
part of the electrical system. Generally accepted
exterior use. Per series of additional GV. 3 To remove the plug, push up the tightly to adapt perfectly to the underground.
rules of technology have to be respected black catch with a screwdriver. Mounting: Cross all areas once and connect
connected areas there are
two GE required. them with each other, starting from GW / GB.
The state of the technology differentiates
between protective equipotential bonding 1 Mounting at an eas- Grounding plug GX The strap can be sticked under the baseboard if
ily accessible point, there are no doors.
and functional equipotential bonding (FEB). Grounding plug for
The protective equipotential bonding (green/yel- close to the final ground
low cable) is a protective measure and ensures connection. portable products Grounding set MCL
that , in the event of a fault, sufficient fault current 2 The underground has (canopies, earthing-prod-
to be smoothed on 20 x ucts, etc.). It is not allowed Grounding set for
flows to operate the disconnection device (e.g. to ground stationary magnetic shielding
line circuit breaker). The functional equipoten- 20 cm with a fine filler (fine
mortar) that is suitable for shielding products (paints, film MCL61. Sufficient for
tial bonding (transparent cable) has the func-
your facade. It is important nettings, fleeces, 5-10 sheets. 1 Glue MCL61
tion to „reduce the emission of low-frequency wallpapers, etc.) with this with the underground.
that the plate has an
electrical fields“, i.e. prevents from leaking
absolute plane under- plug. 1 Danger to life by 2 Drill 6 mm holes. Make
electrical field. wrong grounding! Installa- sure you do not drill cables
ground for a good contact
tion only from a licensed electrician in grounded in the proximity of power
1 Grounding/earthing measures are only per- to the shielding paint. Let
3-prong networks with an earth leakage circuit outlets and switches!
the fine filler dry.
mitted in TN-S, TT and IT networks. Grounding
3 Drill 6 mm holes. breaker less than 30 mA. 2 Put the plug in a 3 Insert dowels. The teeth of the chopper disk
measures must never be executed in network socket-outlet. 3 You can connect up to 4 cables must show down. 4 Screw down the cable lug
forms with combined PEN-wiring! 2 A leak- Make sure you don’t
GC to the sockets. The plugs fits very stiff in the on the chopper disk very hard, so that the teeth
age/fault circuit breaker with ≤ 30 mA must drill cables! Insert dowels.
be installed! 3 DIN EN 62305-3 (VDE 185-305- 4 Paint the area with sockets! penetrates the polyester film.
3:2006-10) applies to buildings with outer the shielding paint, as
lightning protection system. recommended in the Grounding cables GC
corresponding technical * Countries with CEE-7/4 sockets
data sheet. After drying, Grounding cables for
Proper grounding sequence apply a second coat under connecting our „German system“:
grounding components: Afghanistan, Algeria,
1 The FEB-balancing circuit has to be connected and around the plate.
Let it dry. GW (wall), GB (baseboard), Andorra, Austria,
directly to the FEB-busbar with a 4 mm² cable 5 Bolt down the GE (exterior), GT (tube), GM Bosnia-Herzegovina,
in the electric circuit distributor (fuse box). 2 In cable lug with the (magnet), GS (screw), GP Bulgaria, Croatia, Estonia,
exceptional cases, the FEB-balancing circuit can grounding cable tightly (electrical outlet), GR (rod), Finland, Germany, Greece,
be connected with a 2.5 mm² cable to a „suit- on the plate. Dont forget GV (Velcro), ... Hungary, Iceland,
able protective earth conductor or balanc- Indonesia, Italy, Korea,
ing line“ in existing installations. 3 Grounding this, its not possible
subsequently! Latvia, Lithuania,
with our grounding plug GP by screwing in the 6 Screw down the plate Luxembourg, Macedonia,
power socket. Grounding is to be completed by Grounding rod GR-40 Moldova, Montenegro, Netherlands, Norway,
a licenced electrician! 4 Less recommended are tightly. Seal the edges of
the cover cap with the Stainless steel grounding Portugal, Romania, Russia, Serbia, Slovenia, South
our grounding rods GR50, GR100. It is neverthe- included waterproof glue. rod for portable products Korea, Spain, Sweden, Syria, Turkey, Ukraine.
less possible to use them in network forms with Clip on the cover cap. (canopies, earthing-prod-
combined PEN-wiring. Please be sure to follow all 7 Paint the area with
local laws and standards. ucts, etc.). It is not allowed ** Countries with CEE-7/7 sockets
water-repellent to ground stationary
facade paints, as shielding products (paints, „French system“:
Our grounding system recommended in the nettings, fleeces, Belgium, Czech Republic,
corresponding technical wallpapers, etc.) with this France, Monaco, Morocco,
Many of our grounding components can be con-
nected to each other with our grounding cables data sheet. plug. 1 Remove the Poland, Slovakia, Tunisia.
GC. The 4 mm gold plugs are fixed very firm and 8 The grounding of rectangular cap from the
contact safe in the tight 3.8 mm connectors. facades has to be included rod tip and dispose it. Beat the rod in the ground
in the potential equal- with a hammer, certainly not hit the connec-
Many grounding plates includes covering caps,
that serve as protection against an accidential ization of the building to tion box! 2 Connect the cable GC. The plug is
unplug of the cables. which the lightning pro- inserted in the socket with a slight tilt and fits
tection systems are con- very stiff. 3 Put on the round cap, impose the
nected to as well. heat shrink tube over the cap. Shrink the heat
shrink tube with a hot-air gun (400°C). 4 Ensure
Grounding plates Wall GW / GB Grounding plate Tube GT in dry areas, that the rod always sticks in wet
earth.
Grounding plates for Grounding plate for
shielding paints, nettings
and fleeces for interior use. earthed installations Grounding rod GR-50 / GR-100
Per series of connected (e.g. heating tubes).
areas there is one GW / GB 1 Put the plate on an uni- Grounding rods to
required. solated position of the connect other
1 Mounting at an eas- (heating) pipe and screw it grounding components.
ily accessible point, down with the both worm GR-50 for mobile
close to the final ground drive clamps. 2 Insert the applications, GR-100 for
plugs. Clip on the covering permanent mounting.
connection.
2 Drill 6 mm holes. cap, that serve as protec- 1 Remove the gray cap.
Make sure you do not drill tion against an accidential unplug of the cable. Hammer the rod into the
earth with suitable heavy
cables!
3.1 For shielding Grounding plate Magnet GM tools. 2 Connect the
paints: Stick grounding cable. Either you use a ready-made cable (e.g.
strap EB2 as shown under Grounding plate for GC1000), or you use an own cable 6-16 mm² with
„Grounding straps“. Paint canopies, fabrics, a cable lug. Attention: Dont forget anything, the
the area with the fleeces, nettings, etc.. heat shrink tube glues all together permanently!
shielding paints as 1 Pull apart the both 4 Replace the gray cap. Shrink the heat shrink
recommended in the plates. 2 Put the plate tube with a hot-air gun (400°C).
corresponding technical with the visible magnet
data sheet. After drying, from behind on the mate- Stainless steel tape ELB
apply a second coat under rial. 3 Let the front plate
and around the plate. Let snap-on. For two-layered Grounding tape for
it dry. fabrics (Silver-Twin, Steel- stainless steel gauzes,
3.2 For nettings, Twin), the front plate with the sockets must con-
tact the conductive side, this is the darker golden
under plaster or in drywall
constructions. 1 The
fleeces: Stick ground- side at Silver-Twin and the gray side at Steel-Twin. groundable materials have
ing strap EB as shown 4 Insert the plugs. to be screwed, stapled or
under „Grounding straps“. glued with 5 cm overlap.
Adhere the materials on 2 To electrically connect
the area with some over- Grounding plate Screw GS the limited width of the
lap as recommended in materials, the steel tape
the corresponding technical data sheets. Our dis- Grounding plate for
persion glue DKL90 is electrically conductive, canopies, fabrics, has to be screwed across all paths as often as
why there is a low electrical resistance after dry- fleeces, nettings, etc.. possible, especially at the overlapping positions.
ing, which is necessary for proper grounding. This 1 Unscrew the both In case of processing under plaster you should
also applies to various wallpaper paste, but there plates and disassem- not plaster over the tape before you have
is no guarantee on that! Let it dry. ble them. 2 Take a tex- screwed it! 3 Screw on your own grounding
4 Insert dowels and tile cutter or a knife (risk of cable with a suitable M6-screw, screw-nut and
cable clamp M6 directly to the steel tape.
screw down the plate injury!) and pierce a small
tightly. hole of 4 mm in the mate-
5 Make sure, that the rial. 3 Insert the plate with
grounding plate is not the screw from behind through the hole. 4 Put
overpainted! Overpaint on the front plate and screw it down. 5 Insert
the area with commer- the plugs.
cial wall paints, wallpa-
pers or use fine plaster
as recom-mended in the