Megaload area India

Department Engineering

Client AFCONS INFRASTRUCTURE LTD.

Project TRESTLE INSTALLATION – GCPL DAHEJ, INDIA

ANALYSIS AND DESIGN OF MEGALOAD LITIFT


Document type SYSTEM ON MATIRAL BARGE (CHANDRA PLUTO-
250)

Content STRUCTURAL CALCULATIONS

Doc. no. HL707-AIDCG-CR-002

CLIENT doc. no. 0049-C90-TSS653-500008-C

PART-C – MATERIAL BARGE-2 (CHANDRA PLUTO- 250 CLASS)

0 17/03/2024 Issued for comments and approval TSA DNS VDT

Rev. Date Document status Prep. Check. Apr.


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Revision history:
Rev. Date Description of revision

0 17/03/2024 Issued for comments and approval

General notes

This document without authorized signatures is uncontrolled, not binding and shall not be used for
the execution of the operation(s) and for construction(s).

This document once printed could become outdated.

Please refer to the Project Document Register for the last updated revision of the document.

Confidential - restricted use

This document and the information contained herein is confidential and is the sole property of
Megaload. Any reproduction, disclosure, modification or use thereof, in whole or in part, is strictly
prohibited without the prior written authorization of Megaload. The recipient shall acquire no rights in
or to such document. Copyrights by Megaload. All rights reserved.

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 2 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Contents
1. INTRODUCTION ......................................................................................................................................... 4
2. REFERENCES............................................................................................................................................... 4
2.1 CODES & SPECIFICATIONS ................................................................................................................ 4
3. MATERIAL SPECIFICATION ......................................................................................................................... 5
4. STRUCTURAL COMPONENT ....................................................................................................................... 6
5. LOAD CONSIDERATION .............................................................................................................................. 6
5.1 Dead Load(DL): ................................................................................................................................ 6
5.2 Lifted load (LL) ......................................................................................................................................... 6
5.3 Wind Load Calculations on Column, ................................................................................................ 7
5.4 Notional Load ................................................................................................................................... 7
5.5 Seismic Load ..................................................................................................................................... 7
6. LOAD COMBINATION ................................................................................................................................. 8
6.1 Servicibility criteria ........................................................................................................................... 8
6.2 Strength criteria ............................................................................................................................... 8
7. Check for lifting Beam ............................................................................................................................... 9
8. CHECK FOR JACK SUPPORT BEAM ........................................................................................................... 16
9. CHECK FOR COLUMN ............................................................................................................................... 22
10. CHECK FOR LIFTING LUG..................................................................................................................... 25
11. CHECK FOR SPREADER MAT ............................................................................................................... 27

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 3 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

1. INTRODUCTION

The presented document covers the analysis and design of proposed lifting arrangement for the
trestle on class 230 barge for transferring the load on to the lifting beam on SPMT. The barge will not
be subjected to any motion forces as it will be properly moored at Rohini yard and at Dahej, it will be
in beaching condition.

2. REFERENCES
2.1 CODES & SPECIFICATIONS

The temporary lifting arrangement & support system is checked in accordance with the following codes &
standards.
a) IS 800:2007 – “General Construction in Steel – Code of Practice-Third revision”.
b) IS 2062 – “Hot rolled medium and high tensile structural steel – Specification (7th revision)”

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 4 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

3. MATERIAL SPECIFICATION

The structural arrangement for lifting arrangement is made with grade IS 2062 or equivalent IS 800-2007.
And other steel materials are with steel grade of E350 or equivalent.

Young modulus =2x10^5Mpa


Poisson’s ratio =0.3

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 5 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

4. STRUCTURAL COMPONENT

Weight of unit Quantity


Sr No. Structural component
(Ton) (Nos.)
1 Lifting Beam 16 1
2 Jack support beam 0.94 4
3 Column 3 4

5. LOAD CONSIDERATION
5.1 Dead Load(DL):
Dead load considered as the self-weight of Megaload system.

5.2 Lifted load (LL)


The lifted load is considered as per the inputs given by the Afcons (client). For analysis and design purpose
the maximum load is considered.

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 6 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

5.3 Wind Load Calculations on Column,

Dia of column = 457 mm

Height of column = 8650 mm

Gross area = ( 0.825 + 0.457) x 8.650

= 11.089 m2

Net area = 2x0.457x8.650

= 7.91 m2

Solidification Factor (ɸ) = Net area/ gross area

= 7.91/11.089 = 0.713

VZ = 20 m/s

Pz = 0.6xVz2

= 0.240

CF = 1.6

Wind Load udl on tower (KN/m) = CF x Pzx dia of column

= 1.6x0.240x0.457

= 0.175 (KN/m)

5.4 Notional Load


5% of total lifted load is considered as notional load.
Total NL = 5/100 * 425 = 21.25 Ton.
The notional load is divided on the lifting points, 4 lifting points are there.
NL = 21.25/4 = 5.33 Ton

5.5 Seismic Load


Seismic loads are not considered in the design of this tower lifting system, due to its temporary nature.

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 7 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

6. LOAD COMBINATION
Load combination will be for strength criteria and serviceability criteria, for checking the deflection of the
structural component and latter for checking the strength capacity of the structural component. The load
factor for each criteria is given below

6.1 Servicibility criteria


Load factor – 1.00

1.00 x DL

6.2 Strength criteria


Load factor – 1.50

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 8 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

7. Check for lifting Beam

Load Calculations

Load under left saddle of trestle = 68.6 Ton

Dynamic load (10%) = 6.86 Ton

Weight of lifting beam = 8 Ton

Total Load = 84 Ton

Load under right saddle of trestle = 162.1 Ton

Dynamic load (10%) = 16.21 Ton

Weight of lifting beam = 8 Ton

Total Load = 187 Ton

Loading Diagram

Reaction@ A= Ra = 130.56 Ton


Reaction @ D= Rd = 140.44 Ton

Factored shear force = 211 Ton

Factored Bending Moment = 1285 Ton.m

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 9 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Section Properties

Flange width (bf) = 500 mm

Flange thk. (tf) = 36 mm

Depth of web = 1464 mm

Web thk. (tw) = 16 mm

Bottom Plate width (Pb) = 750 mm

Bottom Plate thk. (tp) = 20 mm

Shear Area (Av) = 23424 mm2

Cross Sectional Area (A) = 74424 mm2

Moment of inertia (Ixx) = 31616.75 x106 mm4

Elastic Section Modulus (Ze) = 50.03 x106 mm3

Plastic Section Modulus (Zp) = 55.03 x 106 mm3

a) Section Classification

As per Table - 2, IS:800-2007

ε = √(250/320) = 0.884

Classification of flange

Outstanding element of compression flange = (b/tf) = 250/36 = 6.94

9.4ε = 9.4x0.884 = 8.31

6.94 < 8.31, b/tf < 9.4ε, hence Flange is class I Plastic.

Classification of web

Neutral axis mid-depth level = (d/tw) = 1464/16 = 91.5

105ε = 105 x 0.884 = 92.82

91.5 < 92.82, d/tw<105ε, hence Web is class 1 Plastic.

The overall section classification is Plastic

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 10 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

b) Check for Shear Capacity

Factored Shear Force = 211 Ton

Shear Area = 23424 mm2

Design Shear Strength = = 394 Ton

Utilization ratio = 54% SAFE

c) Check for Low Shear or High Shear

Factored Shear Force (V) = 211 Ton

Design Shear Force (Vd) = 394 Ton

As per Clause 8.2.1.2, IS800-2007, 0.6 x Vd = 236.4 Ton

Since V<0.6 x Vd, it’s in low shear SAFE

d) Check for Bending Capacity

Factored Bending Moment = 1285 Ton.m

β =1

Design Bending Strength = = 1456 Ton.m

Utilization ratio = 88% SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 11 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

e) Check for Connection

Check of Macalloy bar for tension ( 75 dia – 4 no’s)

Grade of Macalloy bar = 10.9 grade

Lever arm = 1510 mm

Factored Maximum moment = 1285 Ton.m

Tension (T= M/L.A) = 851 Ton

Tension capacity for one bar = 258 Ton

Total Tension Capacity = 1032 Ton

Utilization ratio = 83%

Check of bolt shear ( 42dia –12 no’s)

Grade of bolt = 10.9 grade

Factored shear force = 211 Ton

Shear capacity for one bolt = 52 Ton

Total Shear Capacity = 624 Ton

Utilization ratio = 34%

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 12 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

f) Check for Web Buckling Capacity

As per clause 8.7.3.1, IS:800-2007

At Under The Load,

Factored Force (V) = 281 Ton

Effective length = 0.7 x 1464 = 1025 mm

Thickness of web (tw) = 16 mm

Thickness of stiffener = 16 mm

Core Area (A) = 31424 mm2

Moment of inertia (Ixx) = 183.68 x106 mm4

Min radius of gyration (r) = sqrt. (Ixx /A) = 76.45 mm

Slenderness ratio (λ) = KL/r = 13.40

stress corresponding to web buckling(τb) = 305.68N/mm2 (Table 9b, IS:800-2007)

Factored Buckling Force (V) = 961 Ton

Utilization ratio = 29%

SAFE

AT SUPPORT,

Factored Force (V) = 211 Ton

Effective length = 0.7 x 1464 = 1025 mm

Thickness of web (tw) = 16 mm

Thickness of stiffener = 16 mm

Core Area (A) = 31424 mm2

Moment of inertia (Ixx) = 183.68 x106 mm4

Min radius of gyration (r) = sqrt. (Ixx /A) = 76.45 mm

Slenderness ratio (λ) = KL/r = 13.40

stress corresponding to web buckling(τb) = 305.68N/mm2 (Table 9b, IS:800-2007)

Factored Buckling Force (V) = 961 Ton

Utilization ratio = 55%

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 13 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

g) Check for Web Crippling Capacity

As per clause 8.7.4, IS:800-2007

At Under The Load,

Factored Force (V) = 281 Ton

Width of stiff Bearing on the Flange (b1) = 800 mm

Length at a slope of 1:2.5 at the

junction of flange to web(n2) = 2.5 x 36 = 90 mm

Bearing width available = b1 + n2 = 890 mm

Web thickness (Tw) = 16 mm

Bearing Area = 14240 mm2

Yield stress of web (Fyw) = 350 N/mm2

Web Crippling capacity = 499 Ton.

Utilization ratio = 56 % SAFE

At Support,

Factored Force (V) = 211Ton

Width of stiff Bearing on the Flange (b1) = 600 mm

Length at a slope of 1:2.5 at the

junction of flange to web(n2) = 2.5 x 36 = 90 mm

Bearing width available = b1 + n2 = 690 mm

Web thickness (Tw) = 16 mm

Bearing Area = 11040 mm2

Yield stress of web (Fyw) = 350 N/mm2

Web Crippling capacity = 386 Ton.

Utilization ratio = 55 % SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 14 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

h) Check For deflection

Deflection is a serviceability limit state and must be calculated based on unfactored load.

Maximum deflection is y.

δmax = 33

δperm = L /300 = 16200/300

= 54 >> δmax SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 15 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

8. CHECK FOR JACK SUPPORT BEAM

Load calculation

Load from lifting beam will be transferred to Jack Support Beam,

Reaction from Lifting Beam = 140.44 Ton

Self weight of jack support beam = 2 Ton

Self weight of L100 jack = 1.52 Ton

Self weight of strands = 0.289 Ton

No. Of jacks = 2 nos.

Load under jack = 73 Ton

Factored load under jack = 110 Ton

Grade of steel = E250

Loading Diagram

Reaction@A = Ra = 73 Ton

Reaction@c = Rd = 73 Ton

Factored Shear Force = 110 Ton

Factored Bending Moment = 107 Ton.m

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 16 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Section Properties

Flange width (b) = 300.00 mm

Depth of web(d) = 636.00 mm

Overall depth(D) = 700.00 mm

Flange thk. (tf) = 32.00 mm

Web thk. (tw) = 17.00 mm

Shear area (Av) = 21624.00 mm2

Cross sectional area(A) = 60024.00 mm2

Moment of inertia (Ixx) = 5.015x109 mm4

Elastic Section modulus (Zexx) = 14.33 x 106 mm3

Radius of gyration (rxx) = 289.05 mm

a) Section Classification

As per Table - 2, IS:800-2007

ε = √(250/240) = 1.02

Classification of flange

Outstanding element of compression flange = (b/tf) = 150/32 = 4.69

9.4ε = 9.4 x 1.02 = 9.588

4.69 < 9.588, b/tf < 9.4ε, hence flange is class I Plastic.

Classification of web

Neutral axis mid-depth level = (d/tw) = 636/17 = 41.18

105ε = 105 x 1 = 105

41.18 < 10 5 , d/tw < 105ε, hence web is class I plastic.

The overall section classification is plastic.

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 17 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

b) Check for Shear Capacity

Factored Shear Force = 110 Ton

Shear Area = 21624 mm2

Design Shear Strength = = 272.3 Ton

Utilization ration = 41% SAFE

c) Check for Low Shear or High Shear

Factored Shear Force (V) = 110 Ton

Design Shear Force (Vd) = 272.3 Ton

As per Clause 8.2.1.2, IS800-2007, 0.6 x Vd = 163.38 Ton

Since V < 0.6 x Vd, it’s in low shear SAFE

d) Check for Bending Capacity

Factored Bending Moment = 107 Ton.m

β =1

Design Bending Strength = = 313 Ton.m

Utilization ratio = 34.18%


SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 18 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

e) Check for Web Buckling Capacity

As per clause 8.7.3.1, IS:800-2007

At Under the load

Buckling load capacity of web with stiffener is calculated below.

Factored Force (V) = 110 Ton

Effective length = 0.7 x 636 = 445.2 mm

Width of stiff Bearing on the Flange (b1) = = 650 mm

45deg. Dispersion length(n1) = 636/2 = 318 mm

Effective bearing width = 600+318+318 = 1286 mm

Thickness of web (tw) = 17 mm

Core Area (A) = 43724 mm2

Moment of inertia (Ixx) = 5.01 x 109 mm4

Min radius of gyration (r) = sqrt. (Ixx /A) = 341.53 mm

Slenderness ratio (λ) = KL/r = 1.30

stress corresponding to web bucking(τb) = 218 N/mm2


(Table 9b, IS:800-2007)

Factored Buckling Force (V) = 500 Ton

Utilization ratio = 22% SAFE

At Support

Buckling load capacity of web with stiffener is calculated below.

Factored Force (V) = 110 Ton

Effective length = 0.7 x 636 = 445.2 mm

Width of stiff Bearing on the Flange (b1) = = 685 mm

45deg. Dispersion length(n1) = 636/2 = 318 mm

Effective bearing width = 685+318 = 1003 mm

Thickness of web (tw) = 17 mm

Core Area (A) = 34102 mm2

Moment of inertia (Ixx) = 3.97 x109 mm4


Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 19 of 30
STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Min radius of gyration (r) = sqrt. (Ixx /A) = 341.32 mm

Slenderness ratio (λ) = KL/r = 1.30

stress corresponding to web bucking(τb) = 218 N/mm2 (Table 9b, IS:800-2007)

Factored Buckling Force (V) = 384 Ton

Utilization ratio = 29 % SAFE

f) Check for Web Crippling Capacity

As per clause 8.7.4, IS:800-2007

At Under the load

Factored Force (V) = = 110 Ton

Width of stiff Bearing on the Flange (b1) = 650 mm

Length at a slope of 1:2.5 at the

junction of flange to web(n2) = 2.5 x 32 = 80 mm

Bearing width available = b1 + n2 = 730 mm

Web thickness (Tw) = 17mm

Bearing Area = 24820 mm2

Yield stress of web (Fyw) = 240 N/mm2


Web Crippling capacity =298 Ton.

Utilization ratio = 37 %
SAFE

At Support

Factored Force (V) = = 110 Ton

Width of stiff Bearing on the Flange (b1) = 685 mm

Length at a slope of 1:2.5 at the

junction of flange to web(n2) = 2.5 x 32 = 80 mm

Bearing width available = b1 + n2 = 765 mm

Web thickness (Tw) = 17mm

Bearing Area = 26010 mm2

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 20 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Yield stress of web (Fyw) = 240 N/mm2


Web Crippling capacity = 310Ton.

Utilization ratio = 36 % SAFE

g) Check For deflection

Deflection is a serviceability limit state and must be calculated based on unfactored load.

Maximum deflection is y.

δmax = 0.686

δperm = L /300 = 3000/300

= 10>> δmax SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 21 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

9. CHECK FOR COLUMN


Section Properties

The load from JSB will be transfer to the column system,

Total load on column = 140.44 Ton

Load coming on single set column = 74 Ton

Self weight of column = 3 Ton

Total load on column = 77

Factored load on column (P) = 116 Ton

External Dia. of column = 457 mm

Internal dia. of column = 425 mm

Grade of steel = E350

Area = 44311.68 mm2

Ixx = 1078.64 x 106 mm4

Iyy = 9080 X 106 mm4

rxx = 156

ryy = 452.67

Zxx = 4.72 x 106 mm3

Zyy = 13.88 x 106 mm3

K = 2 (From Table 11)

α = 0.21 (Buckling Class ‘a’, from table 7)

x (xeta) = 1 (from Table 9 ‘a’)

λ = Kx L/rxx = 1.14

ɸ = 1.62

Fcd = X x fy/ ϒm0 < Fy / ϒmo

= 320x1/1.10 < 290.90

= 120.44 < 290.90 SAFE

Pd = Ae x Fcd

= 533.7 T = 116 < 534 Ton SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 22 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

a) Wind Load Calculations on Column,

Dia of column = 457 mm

Height of column = 8650 mm

Gross area = ( 0.825 + 0.457) x 8.650

= 11.089 m2

Net area = 2x0.457x8.650

= 7.91 m2

Solidification Factor (ɸ) = Net area/ gross area

= 7.91/11.089 = 0.713

VZ = 20 m/s

Pz = 0.6xVz2

= 0.240

CF = 1.6

Wind Load udl on tower (KN/m) = CF x Pzx dia of column

= 1.6x0.240x0.457

= 0.175 (KN/m)

Axial force = 77 Ton

Factored axial force = 77x1.5 = 116 Ton

Horizontal load = 1.4+5.3 = 6.8 Ton

Bending force = 53.60 Ton.m

Factored bending force = 53.6 x 1.5 = 80.40 Ton.m

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 23 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

b) Check for Bending Capacity

Factored Bending Moment = 80.40 Ton.m

β =1

Design Bending Strength = = 137.30 Ton.m

Utilization ratio = 60 % SAFE

For Zyy = 13.88 x 106 mm3,

Factored Bending Moment = 80.40 Ton.m

β =1

Design Bending Strength = = 404 Ton.m

Utilization ratio = 20 % SAFE

c) Check For Combined Axial Force & Bending Moment

N ( axial force) ` = 116 T

Nd = Ag x fy/ϒmo

= 44311.68 x 320/ 1.10

= 1289 T

(N/Nd)^2 + (MY/Mdy)^2 + (Mz/Mdz)^2 < 1 = (116/1289)^2 +(80.40/137.30)^2 +(80.40/404)^2

= 0.40 < 1 SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 24 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

10. CHECK FOR LIFTING LUG

a) Check for shear

Shear Area = 8426 mm2

Load on each Lug = 70.22 Ton

Factored load = 105.33 Ton

Shear Capacity = Av x Fy / 1.73 x 1.10

= 146 Ton

Utilization ratio = 72 %

b) Check for bearing

Grade of steel = E350

Ag = 4800 mm2

Bearing Capacity = Ag x Fy

= 4800 x 330 = 158 Ton

Utilization ratio = 67%

c) Check for Pin

Grade of Pin = 10.9

Ultimate stress (Fu) = 1040 MPA

Yield stress ( Fy) = 940 MPA

Loading Diagram

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 25 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Factored shear = 53Ton

Factored moment = 3.52 Ton.m

d) Check for Shear Capacity

Factored Shear Force = 53 Ton

Shear Area = 5024 mm2

Design Shear Strength = = 248 Ton

Utilization ration = 22% SAFE

e) Check for Bending Capacity

Factored Bending Moment = 3.52 Ton.m

β =1

Design Bending Strength = = 4.3 Ton.m

Utilization ratio = 82 % SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 26 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

11. CHECK FOR SPREADER MAT

Total load coming on the spreader mat = 140.44 Ton

Self weight of jack support beam = 2 Ton

Self weight of column = 6 Ton

Total load = 148.44 Ton

Grade of steel = E250

Loading Diagram

Factored shear = 55.69 Ton

Factored Bending Moment = 41.75 Ton.m

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 27 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

Section

Flange width (b) = 307.4 mm

Depth of web(d) = 277.1 mm

Overall depth(D) = 314.5 mm

Flange thk. (tf) = 18.7 mm

Web thk. (tw) = 12 mm

Shear area (Av) = 23277 mm2

Cross sectional area(A) = 103754 mm2

Moment of inertia (Ixx) = 1.91x109 mm4

Elastic Section modulus (Zexx) = 12.16 x 106 mm3

Radius of gyration (rxx) = 135.68 mm

a) Section Classification

As per Table - 2, IS:800-2007

ε = √(250/250) =1

Classification of flange

Outstanding element of compression flange = (b/tf) = 154/18.7 = 8.24

9.4ε = 9.4 x 1 = 9.4

8.24 < 9.588, b/tf < 9.4ε, hence flange is class I Plastic.

Classification of web

Neutral axis mid-depth level = (d/tw) = 277.1/12 = 23.09

105ε = 105 x 1 = 105

23.09 < 105, d/tw < 105ε, hence web is class I plastic.

The overall section classification is plastic.

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 28 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

b) Check for Shear Capacity

Factored Shear Force = 55.69 Ton

Shear Area = 23277 mm2

Design Shear Strength = = 403 Ton

Utilization ration = 14% SAFE

c) Check for Bending Capacity

Factored Bending Moment = 41.75 Ton.m

β =1

Design Bending Strength = = 365 Ton.m

Utilization ratio = 12% SAFE

d) Check for Web Buckling Capacity

As per clause 8.7.3.1, IS:800-2007

At Under The Load

Factored Force (V) = 105.3 Ton

Effective length = 0.7 x 277.1 = 445.2 mm

Width of stiff Bearing on the Flange (b1) = 685 mm

45deg. Dispersion length(n1) = 277.1/2 = 139 mm

Effective bearing width = 685+139+139 = 963 mm

Thickness of web (tw) = 12 mm

Core Area (A) =34668 mm2

Moment of inertia (Ixx) = 530.14x106 mm3

Min radius of gyration (r) = sqrt. (Ixx /A) = 124 mm

Slenderness ratio (λ) = KL/r = 1.56

stress corresponding to web buckling(τb) = 218 N/mm2 (Table 9b, IS:800-2007)

Factored Buckling Force (V) = 252 Ton

Utilization ratio = 42% SAFE

Doc. nr. HL-768-ACBDE-CR-001 Rev. 00 29 of 30


STRUCTURAL CALCULATIONS
STRUCTURAL CHECK OF LIFTING BEAM,
JACK SUPPORT BEAM, COLUMN

e) Check for Web Crippling Capacity

As per clause 8.7.4, IS:800-200

At Under The Load

Factored Force (V) = 1.50 x 90 = 105.3 Ton

Width of stiff Bearing on the Flange (b1) = 685 mm

Length at a slope of 1:2.5 at the

junction of flange to web(n2) = 2.5 x 18.7 = 46.75 mm

Bearing width available = b1 + n2 = 732 mm

Web thickness (Tw) = 12 mm

Bearing Area = 8784 mm2

Yield stress of web (Fyw) = 250 N/mm2

Web Crippling capacity = 219 Ton

Utilization ratio = 48% SAFE

12) Check For Deck Strength

Total load from lifting beam to column = 140.44 Ton

Self weight of Jack support beam = 2 Ton

Self weight of column = 6 Ton

Total load = 148.44 Ton

Strength of deck (Stress) = F/A

= 148.44x104 /103754

= 14.31 N/mm2