Professional Documents
Culture Documents
Global Elastomeric Product Catalog - GLBL - MG33 - 17 - 0001
Global Elastomeric Product Catalog - GLBL - MG33 - 17 - 0001
A M B U L ATO R Y S Y S T E M S
Infusor
A M B U L ATO R Y S Y S T E M S
Infusor
A M B U L ATO R Y S Y S T E M S
Filling port
Trusted
with sterilized cap
35
closing valve A set of 2 times 4 protuberances
at home in the hospital indicates when the infusor is
Beginning of the empty
Lyme disease)
Baxter Healthcare SA
Postfach, 8010 Zürich
p +41 (0) 44 878 60 00 f +41 (0) 44 878 63 50
www.baxter.com
Baxter Healthcare Corporation All rights reserved.
Instructions for use available from your Baxter representative.
GLBL/MG33/0417/0001 – Date of creation/review: May 2017.
Single rate - Slow flow Single rate - Fast flow Variable rate - Slow flow
Infusor and FOLFusor Intermate Multirate
Small volumes and RA Infusor
Name SV5 SV4 SV2.5 SV2 SV1 SV0.5 Name SV200 SV100 SV50 LV250 LV100 LV50 XLV250 Name SV 1,2,3 LV 2,3,5 LV 2,4,6 LV 5,7,12 RA Infusor
Nominal flow rate 5 ml/h 4 ml/h 2.5 ml/h 2 ml/h 1 ml/h 0.5 ml/h Nominal flow rate 200 ml/h 100 ml/h 50 ml/h 250 ml/h 100 ml/h 50 ml/h 250 ml/h Nominal flow rates 1, 2, 3 ml/h 2, 3, 5 ml/h 2, 4, 6 ml/h 5, 7, 12 ml/h 5, 7, 12 ml/h
Code Country code Country code Country code Country code Country code Country code Code Country code Country code Country code Country code Country code Country code Country code Bolus flow rate and lock out time - - - - 5 ml and 30 min
Nominal infusion duration 1 day 1 day 2 days 2 days 5 days 7 days Nominal infusion duration 30 min 1h 2h 1h 2 h 30 min 5h 2h Code Country code Country code Country code Country code Country code
Nominal +residual volumes 120 ml + 1 ml 96 ml + 1 ml 120 ml + 1 ml 96 ml + 1 ml 120 ml + 1 ml 84 ml + 1 ml Nominal + residual volumes 100 ml + 1 ml 100 ml + 1 ml 100 ml + 1 ml 250 ml + 3 ml 250 ml + 3 ml 250 ml + 3 ml 500 ml + 5 ml Nominal infusion duration 32 to 96 h 2 to 5 days 40 h to 5 days 20 to 48 h 20 to 48 h
Minimum volume 108 ml 86 ml 108 ml 86 ml 86 ml 76 ml Minimum volume 90 ml 90 ml 90 ml 225 ml 225 ml 225 ml 450 ml Nominal + residual volumes 96 ml + 1 ml 240 ml + 3 ml 240 ml + 3 ml 240 ml + 3 ml 240 ml + 5 ml
Maximum volume 121 ml 97 ml 121 ml 97 ml 97 ml 85 ml Maximum volume 105 ml 105 ml 105 ml 275 ml 275 ml 275 ml 550 ml Minimum volume 86 ml 216 ml 216 ml 216 ml 216 ml
Accuracy +/- 10 % +/- 10 % +/- 10 % +/- 10 % +/- 10 % +/- 10 % Accuracy +/- 15 % +/- 15 % +/- 15 % +/- 15 % +/- 15 % +/- 15 % +/- 15 % Maximum volume 130 ml 300 ml 300 ml 300 ml 300 ml
Calibrating solution D5%* D5%* D5%* D5%* D5%* D5%* Calibrating solution NS** NS** NS** NS** NS** D5%* NS** Accuracy +/- 10 % +/- 10 % +/- 10 % +/- 10 % +/- 10 %
Calibrating temperature 33.3°C 33.3°C 33.3°C 33.3°C 33.3°C 33.3°C Calibrating temperature 21.1°C 21.1°C 21.1°C 21.1°C 21.1°C 21.1°C 21.1°C Calibrating solution D5%* D5%* D5%* D5%* D5%*
Calibrating temperature 33.3°C 33.3°C 33.3°C 31.1°C 31.1°C
Colour code Colour code
Colour code
Chemotherapy † Chemotherapy †
Analgesia †
Analgesia †
Anti-infective therapy†
†
†
This is a recommendation for use only. Always refer to the operating instructions. * D5% = 5% dextrose †
This is a recommendation for use only. Always refer to the operating instructions. * D5% = 5% dextrose This is a recommendation for use only. Always refer to the operating instructions. * D5% = 5% dextrose
** NS = sodium chloride
Note:
The following factors may further affect the flow rate accuracy:
fill volume, temperature, viscosity of the medication, the difference in height between
Catheter for continuous wound infusion the fill port and the distal end luer lock and catheter size.
Infusor and FOLFusor
Large volumes For the safe and proper use of the devices referenced within,
refer to the complete Instructions for Use or the appropriate
Name PAINfusor PAINfusor PAINfusor PAINfusor PAINfusor manual.
Name Catheter 2.5 Catheter 7.5 Catheter 15 Catheter 22.5 Catheter 30
LV10 LV7 LV5 LV2 LV1.5 XLV8 For detailed information, refer to the instructions for use.
Nominal flow rate 10 ml/h 7 ml/h 5 ml/h 2 ml/h 1.5 ml/h 8 ml/h Code Country code Country code Country code Country code Country code
Code Country code Country code Country code Country code Country code Country code Multiperforated length 2.5 cm 7.5 cm 15 cm 22.5 cm 30 cm
Nominal infusion duration 1 day 39 h 2 days 5 days 7 days 3 days Total length 37.5 cm 42.5 cm 50 cm 57.5 cm 65 cm
Nominal + residual volumes 240 ml + 3 ml 272 ml + 3 ml 240 ml + 3 ml 240 ml + 3 ml 252 ml + 3 ml 576 ml + 5 ml
Minimum volume 216 ml 245 ml 216 ml 216 ml 227 ml 461 ml
Maximum volume 300 ml 300 ml 300 ml 300 ml 300 ml 600 ml
Baxter, INfusor, Intermate and FOLfusor are trademarks of Baxter International, Inc.
Accuracy +/- 10 % +/- 10 % +/- 10 % +/- 10 % +/- 10 % +/- 15 %
Calibrating solution D5%* D5%* D5%* D5%* D5%* NS**
Calibrating temperature 31.1°C 33.3°C 31.1°C 33.3°C 33.3°C 31°C Carry bags Stand alone clamp
Colour code
† Please contact your local Baxter representative for availability in your country.
This is a recommendation for use only. Always refer to the operating instructions. * D5% = 5% dextrose
** NS = sodium chloride