TOWER INSTALLATION
MANUAL

São Paulo - Guarulhos


International Airport

CISCEA - Comissão de
Implantação do Sistema
de Controle do Espaço
Aéreo

25.05.2022

20300-0304-B01

ACAMS AS Tel.: +47 23 13 44 40


Olaf Helsets vei 6 Fax.: +47 23 13 44 41
N-0694 OSLO mail@acams.no
Norway www.acams.com
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

CHANGE HISTORY

Issue Date Author Description of Change Approved By


B01 25.05.2022 PHR Standard Tower Installation Manual JFR

Document no: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: ToC Page i
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

TABLE OF CONTENTS

Section Page

1 INTRODUCTION ................................................................................................................... 1
1.1 Scope of this Document ........................................................................................................ 1
1.2 Purpose of this Document ..................................................................................................... 1
1.3 Warnings ............................................................................................................................... 1
2 EQUIPMENT LIST ................................................................................................................ 2
2.1 Equipment List ...................................................................................................................... 2
3 SYSTEM AND ELECTRICAL ENCLOSURES................................................................... 12
3.1 Enclosure List ...................................................................................................................... 12
4 CABLING STANDARDS .................................................................................................... 13
4.1 Cable Numbering System ................................................................................................... 13
4.2 Power Cables Standard ...................................................................................................... 14
4.3 Cable/Wire Color Standard ................................................................................................. 14
5 EQUIPMENT LAYOUT ....................................................................................................... 15
6 EQUIPMENT CABLING AND WIRING .............................................................................. 17
6.1 Central Equipment .............................................................................................................. 17
6.2 ALCMS LAN ........................................................................................................................ 25
6.3 Tower LAN .......................................................................................................................... 26
6.4 Contoller Working Position Cabling .................................................................................... 27
6.5 Tower Interface - QDC15 .................................................................................................... 34
6.6 ATIS .................................................................................................................................... 36
6.7 INTRAER............................................................................................................................. 37
6.8 ATN BR ............................................................................................................................... 38
6.9 INFRANET .......................................................................................................................... 39
6.10 Meteorology......................................................................................................................... 40
6.11 NAVAIDS............................................................................................................................. 42
6.12 Interlock ............................................................................................................................... 44
6.13 Crash Alarm ........................................................................................................................ 47
6.14 Backup Radio ...................................................................................................................... 51
6.15 Access Control .................................................................................................................... 52
6.16 Tower Lighting ..................................................................................................................... 55
6.17 Tower Sunshade Blinds ...................................................................................................... 60
7 CABLE LIST ....................................................................................................................... 65
7.1 Master Cable List ................................................................................................................ 65

Document no: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: ToC Page ii
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

1 INTRODUCTION

1.1 Scope of this Document

This document describes the ACAMS control tower installation to be implemented at the São
Paulo - Guarulhos International Airport - SBGR.

Specifically, this manual details the ACAMS Integrated Tower System equipment layout, power
distribution and wiring, network connectivity, fiber-optic infrastructure, external systems
integration, control/automation circuits and network adapters Inputs/Outputs.

Throughout this document, elements noted as ‘Provision’ are included for document
standardization and ‘place-holding’ purposes. This is also applicable to elements included in
anticipation of systems and equipments, not currently installed, that could be added or integrated
in the future.

This standard installation manual will be updated in order to incorporate changes needed to meet
local requirements and an as-installed version will be issued accordingly.

1.2 Purpose of this Document

This manual is provided as technical reference to qualified technicians involved in installing,


operating, servicing and maintaining the ACAMS Integrated Tower System and other
interconnected equipment.

As described, this document contains exclusively equipment layouts, cabling information and
wiring schematics of the control tower installation. Therefore, for specific hardware specifications
and configuration, refer to the ‘Technical manual’ and for software functionalities and system
operation, refer to the ‘Operator Manual’.

1.3 Warnings

WARNING: Electrical Hazard

Some system components function with life-threatening voltages and may


present a risk of electrical shock. Work on electrical components shall be handled
by qualified personnel only.

Section: INTRODUCTION Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 1
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

2 EQUIPMENT LIST

The following list is a general equipment inventory of the hardware integral to the ACAMS system.
Each equipment is listed by name, as referenced throughout this manual, and a brief description
is given. This list may include pre-existing elements installed during the previous system
upgrades.

For more details, such as official P/N, S/N, new or previous elements and spare equipment
information, refer to ‘Logistic’ acceptance documents.

2.1 Equipment List

Level
Item Equipment Description Model
I II III IV V
* 1. Central Equipment --
* 1.1 - ACAMS Rack 19"42U N/A
* 1.1.1 - ACAMS Server 1 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.2 - ACAMS Server 2 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.3 - ACAMS Server 3 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.4 - ACAMS Server 4 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.5 - TATIC Server 1 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.6 - TATIC Server 2 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.7 - TATIC Server 3 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.8 - TATIC Server 4 HPE ProLiant Server DL360 Gen10 P19774-B21
* 1.1.9 - SAN HPE MSA 2050 SAS SFF storage Q1J29A
* 1.1.9.1 - SAN Controller 1 HPE MSA 2050 Controller 876129-002
* 1.1.9.2 - SAN Controller 2 HPE MSA 2050 Controller 876129-002
* 1.1.10 - KVM Tray ATEN KVM Switch LCD CL5708N-B
* 1.1.11 - Sound bar Wohler VMQ-4 Rack mounted speaker 8110-0030
* 1.1.12 - Nport 1 MOXA 16 port Serial Device Server NPORT 5650-16
* 1.1.13 - Nport 2 MOXA 16 port Serial Device Server NPORT 5650-16
* 1.1.14 - LAN Switch 1 Aruba 24 port LAN Switch J9776-60201
* 1.1.14.1 - SFP Aruba SFP Fiber Module LC LX 1990-4414
* 1.1.14.2 - SFP Aruba SFP Fiber Module LC LX 1990-4414
* 1.1.15 - LAN Switch 2 Aruba 24 port LAN Switch J9776-60201
* 1.1.15.1 - SFP Aruba SFP Fiber Module LC LX 1990-4414
* 1.1.15.2 - SFP Aruba SFP Fiber Module LC LX *Provision
* 1.1.16 - LAN Switch 3 Aruba 24 port LAN Switch J9776-60201
* 1.1.16.1 - SFP Aruba SFP Fiber Module LC LX 1990-4414
* 1.1.16.2 - SFP Aruba SFP Fiber Module LC LX 1990-4414
* 1.1.17 - LAN Switch 4 Aruba 24 port LAN Switch J9776-60201
* 1.1.17.1 - SFP Aruba SFP Fiber Module LC LX 1990-4414

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 2
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 1.1.17.2 - SFP Aruba SFP Fiber Module LC LX *Provision
* 1.1.18 - Firewall 1 Cisco 8 port Firewall ASA5506-X
* 1.1.18.1 - PSU 19V DC Power Supply Unit N/A
* 1.1.19 - Firewall 2 Cisco 8 port Firewall ASA5506-X
* 1.1.19.1 - PSU 19V DC Power Supply Unit N/A
* 1.1.20 - PDU1 12-Socket Strip 220V AC AP9565
* 1.1.21 - PDU2 12-Socket Strip 220V AC AP9565
* 1.1.22 - PDU3 12-Socket Strip 220V AC AP9565
* 1.1.23 - PDU4 12-Socket Strip 220V AC AP9565
* 1.1.24 - Bell Modems Assembly *Provision
* 1.1.25 - ASU ACAMS ATIS Switchover Unit ASU1A-2A
* 1.1.26 - Crash Alarm and I/O Assembly --
* 1.1.26.1 - Rack Mounted 3U Chassis N/A
* 1.1.26.2 - Power Supply --
* 1.1.26.2.1 - PSU 1 Traco 220V AC/ 24V DC Power Supply Unit TSP-090-124
* 1.1.26.2.2 - PSU 2 Traco 220V AC/ 48V DC Power Supply Unit TSP-090-148
* 1.1.26.2.3 - Phase Filter *Provision
* 1.1.26.3 - NA 1 MOXA I/O Network Adapter NA-4010
* 1.1.26.3.1 - DO1 MOXA Digital Output Module - 8 Channels M-2801
* 1.1.26.3.2 - DI1 MOXA Digital Input Module - 8 Channels M-1801
* 1.1.27 - Rack ODF Rack mounted Optical Distribution Frame N/A
* 1.1.28 - NAVAIDS OFC assembly *Provision

* 2. Position Equipment --
* 2.1 - Position 1 TWR --
Workstation 1
* 2.1.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.1.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 2
* 2.1.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.1.2.1 - PSU 19V DC Power Supply Unit N/A
Touch Monitor
* 2.1.3 - NEC 24" LCD touch screen P242W-BK
TATIC
Touch Monitor
* 2.1.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.1.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.1.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.1.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.1.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.1.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.1.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.2 - Position 2 GND 1 --
Workstation 3
* 2.2.1 - HP EliteDesk mini computer 6AU18AV
TATIC

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 3
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 2.2.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 4
* 2.2.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.2.2.1 - PSU 19V DC Power Supply Unit N/A
Touch Monitor
* 2.2.3 - NEC 24" LCD touch screen P242W-BK
TATIC
Touch Monitor
* 2.2.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.2.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.2.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.2.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.2.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.2.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.2.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.3 - Position 3 CLR --
Workstation 5
* 2.3.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.3.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 6
* 2.3.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.3.2.1 - PSU 19V DC Power Supply Unit N/A
Touch
* 2.3.3 - NEC 24" LCD touch screen P242W-BK
MonitorTATIC
Touch Monitor
* 2.3.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.3.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.3.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.3.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.3.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.3.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.3.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.4 - Position 4 SUP --
Workstation 7
* 2.4.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.4.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 8
* 2.4.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.4.2.1 - PSU 19V DC Power Supply Unit N/A
Touch Monitor
* 2.4.3 - NEC 24" LCD touch screen P242W-BK
TATIC
Touch Monitor
* 2.4.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.4.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.4.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.4.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.4.8 - Speakers Logitech Stereo Speakers Z120 980-000513

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 4
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 2.4.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.4.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.5 - Position 5 SO --
Workstation 9
* 2.5.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.5.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 10
* 2.5.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.5.2.1 - PSU 19V DC Power Supply Unit N/A
Touch Monitor
* 2.5.3 - NEC 24" LCD touch screen P242W-BK
TATIC
Touch Monitor
* 2.5.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.5.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.5.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.5.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.5.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.5.9 - (no PTT Mic) -- *Provision
* 2.5.9.1 - (no Mic Adapter) -- *Provision
* 2.6 - Position 6 TWR 2 --
Workstation 11
* 2.6.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.6.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 12
* 2.6.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.6.2.1 - PSU 19V DC Power Supply Unit N/A
Touch
* 2.6.3 - NEC 24" LCD touch screen P242W-BK
MonitorTATIC
Touch Monitor
* 2.6.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.6.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.6.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.6.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.6.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.6.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.6.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.7 - Position 7 TWR Asst. --
Workstation 13
* 2.7.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.7.1.1 - PSU 19V DC Power Supply Unit N/A
* 2.7.2 - (No Workstation 14 ACAMS) *Provision
* 2.7.2.1 - (No PSU) *Provision
Touch Monitor
* 2.7.3 - NEC 24" LCD touch screen P242W-BK
TATIC
* 2.7.4 - (no Touch Monitor ACAMS) *Provision
* 2.7.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 5
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 2.7.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.7.7 - (no KVM) *Provision
* 2.7.8 - (no Speakers) *Provision
* 2.7.9 - (no PTT Mic) *Provision
* 2.7.9.1 - (no Mic Adapter) *Provision
* 2.8 - Position 8 GND 2 --
Workstation 15
* 2.8.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.8.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 16
* 2.8.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.8.2.1 - PSU 19V DC Power Supply Unit N/A
Touch Monitor
* 2.8.3 - NEC 24" LCD touch screen P242W-BK
TATIC
Touch Monitor
* 2.8.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.8.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.8.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.8.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.8.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.8.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.8.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.9 - Position 9 GND Asst. --
Workstation 17
* 2.9.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.9.1.1 - PSU 19V DC Power Supply Unit N/A
* 2.9.2 - (No Workstation 18 ACAMS) *Provision
* 2.9.2.1 - (No PSU) *Provision
Touch Monitor
* 2.9.3 - NEC 24" LCD touch screen P242W-BK
TATIC
* 2.9.4 - (no Touch Monitor ACAMS) *Provision
* 2.9.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.9.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.9.7 - (no KVM) *Provision
* 2.9.8 - (no Speakers) *Provision
* 2.9.9 - (no PTT Mic) *Provision
* 2.9.9.1 - (no Mic Adapter) *Provision
* 2.10 - Position 10 CLR Asst. --
Workstation 19
* 2.1.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.1.1.1 - PSU 19V DC Power Supply Unit N/A
* 2.1.2 - (No Workstation 20 ACAMS) *Provision
* 2.1.2.1 - (No PSU) *Provision
Touch Monitor
* 2.1.3 - NEC 24" LCD touch screen P242W-BK
TATIC

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 6
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 2.1.4 - (no Touch Monitor ACAMS) *Provision
* 2.1.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.1.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.1.7 - (no KVM) *Provision
* 2.1.8 - (no Speakers) *Provision
* 2.1.9 - (no PTT Mic) *Provision
* 2.1.9.1 - (no Mic Adapter) *Provision
* 2.11 - Position 11 Coord. --
Workstation 21
* 2.11.1 - HP EliteDesk mini computer 6AU18AV
TATIC
* 2.11.1.1 - PSU 19V DC Power Supply Unit N/A
Workstation 22
* 2.11.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.11.2.1 - PSU 19V DC Power Supply Unit N/A
Touch Monitor
* 2.11.3 - NEC 24" LCD touch screen P242W-BK
TATIC
Touch Monitor
* 2.11.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.11.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.11.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.11.7 - KVM ATEN LCD KVM Switch CS782DP
* 2.11.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.11.9 - PTT Mic Bosh Handheld Microphone LBB 9080/00
* 2.11.9.1 - Adapter XLR-USB Audio Interface Cable 82704
* 2.12 - Position 12 TCMS --
* 2.12.1 - (No Workstation 23 TATIC) *Provision
* 2.12.1.1 - (No PSU) -- *Provision
Workstation 24
* 2.12.2 - HP EliteDesk mini computer 6AU18AV
ACAMS
* 2.12.2.1 - PSU 19V DC Power Supply Unit N/A
* 2.12.3 - (no Touch Monitor TATIC) *Provision
Touch Monitor
* 2.12.4 - NEC 24" LCD touch screen P242W-BK
ACAMS
* 2.12.5 - Keyboard Logitech K740 Illuminated Keyboard 820-005633
* 2.12.6 - Mouse Logitech M500 7-Button USB Mouse 810-004116
* 2.12.7 - (no KVM) *Provision
* 2.12.8 - Speakers Logitech Stereo Speakers Z120 980-000513
* 2.12.9 - (no PTT Mic) *Provision
* 2.12.9.1 - (no Mic Adapter) *Provision

* 3. Substation Equipment --
* 3.1 - QDC1 Substation ALCMS enclosure *Provision
* 3.2 - QDC2 Substation ALCMS enclosure *Provision
* 3.3 - QDC3 Substation ALCMS enclosure *Provision

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 7
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 4. Beacon System --
* 4.1 - QDC4 Beacon Control enclosure --
* 4.1.1 - Wall-mounted enclosure --
* 4.1.2 - Power Supply --
* 4.1.3 - Network Adapter --

* 5. Tower Lighting System --


* 5.1 - QDC10 Task Lights Control enclosure --
* 5.1.1 - Wall-mounted enclosure N/A
* 5.1.2 - Power Supply --
* 5.1.2.1 - PSU 1 Traco 220V AC/ 24V DC Power Supply Unit TSP-090-124
* 5.1.2.2 - PSU 2 *Provision
* 5.1.2.3 - Phase Filter *Provision
* 5.1.3 - NA 1 MOXA I/O Network Adapter NA-4010
* 5.1.3.1 - AO1 MOXA Analog Output Module - 4 Channels M-4410
* 5.1.3.2 - AO2 MOXA Analog Output Module - 4 Channels M-4410
* 5.1.4 - Dimmer modules --
* 5.1.4.1 - Dimmer module 1 SE Varintens Universal-Dimmer 4x2.5A 230V AC UDK-04-10
* 5.1.4.2 - Dimmer module 2 SE Varintens Universal-Dimmer 4x2.5A 230V AC UDK-04-10
* 5.2 - Spotlight Rails LED Spotlight rail tracks --
* 5.2.1 - Spotlights Table Sylvania Lighting Muse II LED Spotlights 2059742
* 5.2.2 - Spotlights TWR Sylvania Lighting Muse II LED Spotlights 2059743
* 5.2.3 - Spotlights TWR Asst Sylvania Lighting Muse II LED Spotlights 2059744
* 5.2.4 - Spotlights GND Sylvania Lighting Muse II LED Spotlights 2059745
* 5.2.5 - Spotlights CLR Sylvania Lighting Muse II LED Spotlights 2059746
* 5.2.6 - Spotlights Room Sylvania Lighting Muse II LED Spotlights 2059747
* 5.2.7 - Spotlights SUP Sylvania Lighting Muse II LED Spotlights 2059748
* 5.2.8 - Spotlights Stairs Sylvania Lighting Muse II LED Spotlights 2059749
* 5.3 - Intermediate distribution *Provision
* 5.4 - Common ceiling lights --
* 5.4.1 - Dimmer Panel 6 x Dimmers panel N/A
* 5.4.2 - IDB Intermediate Distribution Box N/A

* 6. Tower Sunshade Blinds System --


* 6.1 - QDC11 Sunshades blinds control enclosure --
* 6.1.1 - Wall-mounted enclosure N/A
* 6.1.2 - Power Supply --
* 6.1.2.1 - PSU 1 Traco 220V AC/ 24V DC Power Supply Unit TSP-090-124
* 6.1.2.2 - PSU 2 *Provision
* 6.1.2.3 - Phase Filter N/A
* 6.1.3 - NA 1 MOXA I/O Network Adapter NA-4010
* 6.1.3.1 - DO 1 MOXA Digital Output Module - 8 Channels M-2801
* 6.1.3.2 - DI 1 MOXA Digital Input Module - 8 Channels M-1801
Section: EQUIPMENT LIST Document ID: 20300-0304-B01
Date: 25.05.2022
© ACAMS AS Page: 8
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
* 6.2 - Sunshades Blinds ATC Solar Control Blinds --
* 6.2.1 - Rollerblind 1 Motorised rollerblind TWR Model 4c
* 6.2.1.1 - Motor 1 Rollerblind motor N/A
* 6.2.2 - Rollerblind 2 Motorised rollerblind TWR Model 4c
* 6.2.2.1 - Motor 2 Rollerblind motor N/A
* 6.2.3 - Rollerblind 3 Motorised rollerblind TWR Model 4c
* 6.2.3.1 - Motor 3 Rollerblind motor N/A
* 6.2.4 - Rollerblind 4 Motorised rollerblind TWR Model 4c
* 6.2.4.1 - Motor 4 Rollerblind motor N/A
* 6.2.5 - Rollerblind 5 Motorised rollerblind TWR Model 4c
* 6.2.5.1 - Motor 5 Rollerblind motor N/A
* 6.2.6 - Rollerblind 6 Motorised rollerblind TWR Model 4c
* 6.2.6.1 - Motor 6 Rollerblind motor N/A
* 6.2.7 - Rollerblind 7 Motorised rollerblind TWR Model 4c
* 6.2.7.1 - Motor 7 Rollerblind motor N/A
* 6.2.8 - Rollerblind 8 Motorised rollerblind TWR Model 4c
* 6.2.8.1 - Motor 8 Rollerblind motor N/A
* 6.3 - Intermediate distribution --

* 7. Access control System --


* 7.1 - QDC13 Tower access control enclosure --
* 7.1.1 - Wall-mounted enclosure N/A
* 7.1.2 - Power Supply --
* 7.1.2.1 - PSU 1 Magnetic lock 12V DC power supply Drigon
* 7.1.2.2 - PSU 2 *Provision
* 7.1.2.3 - Phase Filter *Provision
* 7.1.3 - Network Adapter *Provision
* 7.1.4 PoE Midspan AXIS 48V DC PoE Midspan PD-3501/AC
* 7.2 - Entrance Equipment --
* 7.2.1 - Network Camera AXIS indoor dome IP camera - HD 720p P3374-V
* 7.2.2 - Magnetic lock Electromagnetic door lock N/A
* 7.2.3 - Exit push button N/A
* 7.2.4 - Break-glass emergency switch N/A
* 7.3 - Access Control Panel N/A
* 7.3.1 - Keypad HDL Entrance Keyboard N/A
* 7.3.2 - Bell push button N/A
* 7.3.3 - Emergency key switch N/A

* 8. Tower Equipment --
* 8.1 - Aviation Barometer
* 8.1.1 - AviMet Display VAISALA Weather Panel Display WID513
* 8.1.2 - Barometer VAISALA Digital Barometer PTB330
* 8.1.3 - PSU 24V DC Power Supply Unit N/A
Section: EQUIPMENT LIST Document ID: 20300-0304-B01
Date: 25.05.2022
© ACAMS AS Page: 9
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V

* 9. Miscellaneous Equipment --
* 9.1 - Printer HP LaserJet Printer M203DW G3Q47A

* 10. Tower Interface System --


* 10.1 - QDC 12 Tower Analog Interface enclosure *Provision
* 10.2 - QDC15 Tower LAN Interface enclosure --
* 10.2.1 - Wall-mounted enclosure N/A
* 10.2.2 - Power Supply --
* 10.2.2.1 - PSU 1 Traco 220V AC/ 24V DC Power Supply Unit TSP-090-124
* 10.2.2.2 - PSU 2 Traco 220V AC/ 24V DC Power Supply Unit TSP-090-124
* 10.2.2.3 - Phase Filter *Provision
* 10.2.3 - LAN Switch 5 PLANET 8+2 ports LAN Switch IGS-10020MT
* 10.2.3.1 - SFP PLANET SFP Fiber Module LC LX MGB-TLX
* 10.2.4 - LAN Switch 6 PLANET 8+2 ports LAN Switch IGS-10020MT
* 10.2.4.1 - SFP PLANET SFP Fiber Module LC LX MGB-TLX
* 10.2.5 - LAN Switch 7 PLANET 8+2 ports LAN Switch IGS-10020MT
* 10.2.5.1 - SFP PLANET SFP Fiber Module LC LX MGB-TLX
* 10.2.6 - LAN Switch 8 PLANET 8+2 ports LAN Switch IGS-10020MT
* 10.2.6.1 - SFP PLANET SFP Fiber Module LC LX MGB-TLX
* 10.2.7 - ODF Mini Optical Distribution Frame N/A

* 11. Crash alarm System --


* 11.1 - Crash alarm Tower Equipment --
* 11.1.1 - Crash alarm push button 1 N/A
11.1.2 - Crash alarm push button 2 N/A
* 11.2 - Group Call IP Phones --
* 11.2.1 - IP Phone - SCI Cisco 1-Line GigE IP Phone SPA512G
* 11.2.2 - IP Phone - COA Cisco 1-Line GigE IP Phone SPA512G
* 11.3 QDC20
* 11.3.1 - Wall-mounted enclosure N/A
* 11.3.2 - Power Supply --

* 12. Emergency Light Signaling System --


* 12.1 Light Gun --
* 12.1.1 - Signal light gun ATI Avionics Signal light gun Model #901
* 12.1.2 - Light gun charger ATI Avionics Signal light gun Charger Model 951C

* 13. VHF Backup System --


* 13.1 - Backup VHF TWR --
* 13.1.1 - TWR Transceiver PARK AIR VHF Transceiver T6 T6-TRV
* 13.1.2 - TWR Controller PARK AIR Desktop controller T6MC BT6MC
* 13.1.3 - TWR Antenna AMPHENOL Ground Plane Antenna 5001000
Section: EQUIPMENT LIST Document ID: 20300-0304-B01
Date: 25.05.2022
© ACAMS AS Page: 10
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Level
Item Equipment Description Model
I II III IV V
GXT-MT-B-
* 13.1.4 - Mini UPS VERTIV Nobreak Liebert GXT MT+ 3kVA 3000VA230
* 13.2 - Backup VHF GND --
* 13.2.1 - TWR Transceiver PARK AIR VHF Transceiver T6 T6-TRV
* 13.2.2 - TWR Controller PARK AIR Desktop controller T6MC BT6MC
* 13.2.3 - TWR Antenna AMPHENOL Ground Plane Antenna 5001000
GXT-MT-B-
* 13.2.4 - Mini UPS VERTIV Nobreak Liebert GXT MT+ 3kVA 3000VA230

* 14. NAVAIDS System --


* 14.1 - Interlock Assembly --
* 14.1.1 - Enclosure --
* 14.1.2 - Power Supply --
* 14.1.3 - Network Adapter --

* 15. Outdoor Camera System --


* 15.1 - Tower PTZ Camera *Provision

***

Section: EQUIPMENT LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 11
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

3 SYSTEM AND ELECTRICAL ENCLOSURES

In the following list, each control cabinet, box and power distribution frame related to the ACAMS
System, generically called ‘enclosures’, is listed by name as referenced throughout this manual.
This list may include pre-existing infrastructure as well as enclosures installed during previous
system upgrades.

3.1 Enclosure List

Name Function Location

ALCMS Enclosures --
QDC4 - Beacon Control Technical Room

Systems Enclosures --
QDC10 - Tower Task Lights Control Tower cabin
QDC11 - Tower Sunshades Blinds Control Tower cabin
QDC12 - Tower Analog Interface enclosure *Provision
QDC13 - Tower Access Control Tower entrance

QDC15 - Tower LAN Interface - ACAMS Network OF/Switches Tower cabin

QDC20 - Crash Alarm Siren SCI - Fire Station

Power Distribution Enclosures --


QDFE - Critical Tower Equipment Power - UPS 220V Tower cabin
QDL - Tower Equipment Power - Commercial 220V Tower cabin

Tower cabin
IDB - Com. Ceiling Lights - Intermediate Distribution Box
(Ceiling)

***

Section: SYSTEM AND ELECTRICAL ENCLOSURES Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 12
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

4 CABLING STANDARDS

4.1 Cable Numbering System

The ACAMS System cables are identified, according to the following numbering plan, with a 3 or
4 digit number and an ‘OF’ prefix is added specifically for fiber-optic cables/cords. Functionally
related cables can be identified with the same number and with a letter or number suffix.

Number Range Description

100 - 199 Central Equipment - LAN 1 (Blue cabling)

200 - 299 Central Equipment - LAN 2 (Yellow cabling)


300 - 399 System LAN and Fiber-Optics
400 - 499 External systems & connections

500 - 699 Operator positions


700 - 799 Substations & ALCMS
800 - 899 Miscellaneous internal
900 - 999 Others
1000 - 1099 Central Equipment Power
1100 - 1399 Operator Position & Tower Systems Power
1400 - 1499 Substation & External Power
***

Obsn.:
1. Each cable in the system is identified with a 3 or 4 digit number;

2. Fiber-Optic cables/cords are identified with 3 digit number and OF prefix.

3. Functionally related cables can be identified with the same number


followed by a letter or number suffix.

Section: CABLING STANDARDS Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 13
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

4.2 Power Cables Standard

Color codification for PP Type power cables


Phase Standard
MONO BI EUROPEAN CODE BRAZILIAN CODE
L L1 Brown Black

N L2 Blue Blue or Light Blue

PE PE Green or Yellow/Green Green or Yellow/Green or white


***

4.3 Cable/Wire Color Standard

Color Abbreviation

Black bk

White wh

Red wh

Blue bl

Orange or

Yellow ye

Green gn

Brown br

Violet vt

Gray gy

Pink pk

Turquoise tq

***

Section: CABLING STANDARDS Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 14
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

5 EQUIPMENT LAYOUT

ACAMS | Central Equipment Rack - Layout


Front Back
42U LAN Switch 1 1.1.14
Crash Alarm
41U Blind
and I/O Assembly
1.1.26 40U Cable organizer
Blind 39U LAN Switch 2 1.1.15
38U Blind
ATIS Switchover Unit
1.1.25 37U Cable organizer
Sound Bar 1.1.11 36U LAN Switch 3 1.1.16
Serial Device Nport 1 1.1.12 35U Blind
Serial Device Nport 2 1.1.13 34U Cable organizer
- ACAMS Profile - 33U LAN Switch 4 1.1.17
Blind 32U Blind
31U Cable organizer
Blind
30U
Firewall 1 Firewall 2
29U 1.1.18 1.1.19
Blind
28U Cable organizer
27U TB1 TB2 TB3
Blind
26U

Krones
25U
Blind TB4
24U
KVM Tray 1.1.10 23U KVM Tray 1.1.10
ACAMS Server 1 1.1.1 22U ACAMS Server 1 1.1.1
ACAMS Server 2 1.1.2 21U ACAMS Server 2 1.1.2
ACAMS Server 3 1.1.3 20U ACAMS Server 3 1.1.3
ACAMS Server 4 1.1.4 19U ACAMS Server 4 1.1.4
TATIC Server 1 1.1.5 18U TATIC Server 1 1.1.5
TATIC Server 2 1.1.6 17U TATIC Server 2 1.1.6
TATIC Server 3 1.1.7 16U TATIC Server 3 1.1.7
TATIC Server 4 1.1.8 15U TATIC Server 4 1.1.8
14U
SAN SAN
1.1.9 13U 1.1.9
12U Shelf
Blind Power distributon
11U
X220 X220 X220 X220
10U
SAK

Blind A B C D
9U
8U PDU 1 220V 1.1.20
Blind
7U PDU 2 220V 1.1.21
6U
Blind
5U
Cable organizer
Blind 4U
ODF 1.1.27 3U
Blind 2U PDU 3 220V 1.1.22
1U PDU 4 220V 1.1.23

Section: EQUIPMENT LAYOUT Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 15
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Control Tower - Layout

Section: EQUIPMENT LAYOUT Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 16
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6 EQUIPMENT CABLING AND WIRING

6.1 Central Equipment

ACAMS | Rack PDUs cabling


QFA-006/DPV-S
UPS 220V/380V

DJ 4 DJ 6 DJ 8 DJ 10 Power Distribution – TBs Layout

SAK Terminal blocks supporting 2.5 mm² Wires

X220 X220 X220 X220


A B C D

1005 1006 1007 1008


Power Distribution TBs

X220 X220 X220 X220


A B C D

1001 1002 1003 1004

PDU 1 220V 1.1.20

PE N L PE N L PE N L PE N L
PDU 2 220V 1.1.21

Cables: 1001 to 1004 Cables: 1005 to 1008


PDU 3 220V 1.1.22
Brown - Live Black - Live
Blue - Neutral Blue - Neutral
PDU 4 220V 1.1.23 Yellow/green - Gnd White - Gnd

- ACAMS Rack rear detail -

ACAMS | Rack PDUs – Electrical diagram


ACAMS Rack
QFA-006/ L Phase B (White)
DPV-S DJ 4
10A X220A
UPS 3
1005 1001 PDU 1 220V 1.1.20
220V/380V
Redundancy

L Phase C (Red)
DJ 6
10A X220B
3
1006 1002 PDU 2 220V 1.1.21
L Phase A (Black)
DJ 8
10A X220C
3
1007 1003 PDU 3 220V 1.1.22
Redundancy

L Phase B (White)
DJ 10
10A X220D
3
1008 1004 PDU 4 220V 1.1.23

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 17
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS |PDU 1 and 3 – Equipment power cabling

QFA-006
DJ 4 UPS 220V DJ 8

1005 ACAMS Rack 1007


X220 A X220 C
1001 1003

1 1
1011 ACAMS Server 1 1051
1.1.1

2 2
1012 ACAMS Server 3 1052
1.1.3

3 3
1013 TATIC Server 1 1053
1.1.5

4 4
1014 TATIC Server 3 1054
1.1.7

5 5
1015 SAN 1055
1.1.9

6 ATIS Switchover 6
PDU 1016
Unit 1.1.25
1056 PDU
1 3
7 7
1017 LAN Switch 1 LAN Switch 2 1057
1.1.14 1.1.15
UPS UPS
8 8
220V 1018 PSU 1018A Firewall 1 Firewall 2 1058A PSU 1058 220V
1.1.18 1.1.19
Socket Socket
9 Serial Device Serial Device 9
strip 1019 1059 strip
NPORT 1 1.1.12 NPORT 2 1.1.13

1.1.20 1.1.22

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 18
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | PDU 2 and 4 – Equipment power cabling

QFA-006
DJ 6 UPS 220V DJ 10

1006 ACAMS Rack 1008


X220 C X220 D
1002 1004

1 1
1031 ACAMS Server 2 1071
1.1.2

2 2
1032 ACAMS Server 4 1072
1.1.4

3 3
1033 TATIC Server 2 1073
1.1.6

4 4
1034 TATIC Server 4 1074
1.1.8

5 5
1035 LAN Switch 3 LAN Switch 4 1075
1.1.16 1.1.17

PDU 6 Crash alarm & I/O 6


PDU
2 1036
PSU1 24V 1.1.26.2.1
KVM Tray
1.1.10
1076 4
7 Crash alarm & I/O 7
1037 Sound Bar 1077
UPS PSU2 48V 1.1.26.2.2 1.1.11 UPS
220V 220V

Socket Socket
strip strip

1.1.21 1.1.23

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 19
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS |Rack KVM Switch - Cabling


ACAMS Rack

PS-1 1
ACAMS Server 1 801
1.1.1 USB
PS-1 2
ACAMS Server 2 802
1.1.2
KVM
USB
3 Switch
PS-1
ACAMS Server 3 803
1.1.3 USB
PS-1 4
ACAMS Server 4 804

PS/2-USB
1.1.4 USB
PS-1 5
TATIC Server 1 805
1.1.5 USB
PS-1 6
TATIC Server 2 806
1.1.6 USB
PS-1 7
TATIC Server 3 807
1.1.7 USB
PS-1 8
TATIC Server 4 808
1.1.8 USB 1.1.10

ACAMS | Rack KVM Switch - Layout

KVM Switch
PS/2-USB
Chain out 8 7 6 5 4 3 2 1
Power Console 2

- Rear view -

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 20
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | SAN - Storage Area Network - Cabling


ACAMS Rack
TATIC Server 1
1.1.5

TATIC Server 2
1.1.6

TATIC Server 3
1.1.7

TATIC Server 4
1.1.8

821 823 825 827 828 826 824 822

DP 4 DP 4

DP 3 SAN SAN DP 3
Controller Controller
DP 2 1 2 DP 2

DP 1 DP 1
1.1.9.1 1.1.9.2
SAN LAN LAN

7 7
LAN Switch 2 157 257 LAN Switch 4
1.1.15 1.1.17

ACAMS | SAN – Storage Area Network - Layout


SAN SAN Controller 1
4 3 2 1 LAN
PSU 1
DP
ON

ON

DP
LAN 1 2 3 4 PSU 2

SAN Controller 2 - Rear view -

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 21
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | LAN 1 – Switches 1 and 2


1 1 1 1
101 ACAMS Server 1 151 ACAMS Server 2
1.1.1 1.1.2
2 1 2 1
102 ACAMS Server 3 152 ACAMS Server 4
1.1.3 1.1.4
3 1 3 1
103 TATIC Server 1 153 TATIC Server 2
1.1.5 1.1.6
4 1 4 1
104 TATIC Server 3 154 TATIC Server 4
1.1.7 1.1.8
5 iLO 5 iLO
105 ACAMS Server 4 155 ACAMS Server 1
1.1.4 1.1.1
6 iLO 6 iLO
106 TATIC Server 4 156 TATIC Server 1
1.1.8 1.1.5
7 LAN 7
107 Serial Device NPORT 1 157 SAN Controller 1
1.1.12 1.1.9.1
8 VoIP
LAN 108
1
ATIS Switchover Unit LAN
1.1.25
Switch Switch
10
1 2 505 SO ACAMS Position

11 1
111 Firewall 1
1.1.18
12 1
112 Firewall 2
1.1.19

VLAN 20
20
425 ALCMS Position

SFP 25 1 ODF to TWR QDC 15 SFP 25 3 ODF to TWR QDC 15


LC LX OF 341 Switch 5 LC LX OF 342 Switch 6
2 TWR 4 TWR
1.1.14.1 1.1.15.1
1.1.27 1.1.27

1.1.14 1.1.15

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 22
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | LAN 2 – Switches 3 and 4


1 2 1 2
201 ACAMS Server 1 251 ACAMS Server 2
1.1.1 1.1.2
2 2 2 2
202 ACAMS Server 3 252 ACAMS Server 4
1.1.3 1.1.4
3 2 3 2
203 TATIC Server 1 253 TATIC Server 2
1.1.5 1.1.6
4 2 4 2
204 TATIC Server 3 254 TATIC Server 4
1.1.7 1.1.8
5 iLO 5 iLO
205 ACAMS Server 2 255 ACAMS Server 3
1.1.2 1.1.3
6 iLO 6 iLO
206 TATIC Server 2 256 TATIC Server 3
1.1.6 1.1.7
7 LAN 7
207 Serial Device NPORT 2 257 SAN Controller 2
1.1.13 1.1.9.2
8 VoIP 8
LAN 208
2 LAN 258 Crash Alarm/Beacon - NA1
1.1.26.1
Switch ATIS Switchover Unit Switch
9 LAN 10
3 209
1.1.25
4 605 SO TATIC Position

11 2
211 Firewall 1
1.1.18
12 2
212 Firewall 2
1.1.19

VLAN 20 13
20
426 n/c ALCMS Position 508 TCMS Position
*Spare

SFP 25 7 ODF to TWR QDC 15 SFP 25 9 ODF to TWR QDC 15


LC LX OF 343 Switch 7 LC LX OF 344 Switch 8
8 TWR 10 TWR
1.1.16.1 1.1.17.1
1.1.27 1.1.27

1.1.16 1.1.17

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 23
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | LAN 1 - 2 Interconnections


22 22
301

LAN 23 23 LAN
304 302
Switch 1 Switch 2
24 24
1.1.14 1.1.15

305 303
22 22

LAN 23 23 LAN
Switch 3 Switch 4
24 24
1.1.16 306 1.1.17

ACAMS | Firewalls Connections


1 11 12 1
111 LAN Switch 1 112
1.1.14
2 11 12 2
211 LAN Switch 3 212
1.1.16

Switch to GRU
3 8 INTRAER 16 3
404 405
(via Infranet)
Firewall 4 5 6 4 Firewall
406 INFRANET - COA 416
1 2
6 IP Phones *Provision 6
407 n/c n/c 417

6 Airport Cameras *Provision 6


407 n/c n/c 417

5 ATN BR 5
422 423
Switch *Provision
8 8
300
1.1.18 1.1.19
*Connections are still to be defined.

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 24
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.2 ALCMS LAN

Technical room
ACAMS Rack

LAN
Switch 1
VLAN 20 AFL Control
425 Workstation
20

Airport Infrastructure
RJ45

1.1.14 GRU Network

LAN
Switch 3
n/c
20
426
*spare
Substations
1.1.16
Airfield Lighting
Systems

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 25
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.3 Tower LAN

ACAMS | Tower LAN Connections


Technical room Tower
ACAMS Rack QDC15

LAN LAN 1 WS2 - TWR ACAMS


501 2.1.2
Switch 1 Switch 5
2 WS1 - TWR TATIC
SFP SFP 601 2.1.1
25 1 1 9
LC LX OF 341 OF 361 LC LX
2 2 3
1.1.14.1 10.2.3.1 310 POE 310A Camera
8.1.1.6 8.1.4
8
1.1.14 10.2.3
OF 1
307
to OF 351 OF 1
1
LAN TWR 7 LAN 503 WS6 - CLR ACAMS
2.3.2
Switch 2 Switch 6
2 WS5 - CLR TATIC
SFP SFP 603 2.3.1
25 3 3 9
LC LX OF 342 OF 362 LC LX
4 4 3 QDC 11 - Sunshades NA1
1.1.15.1 10.2.4.1 312 5.1.2
5 5
spare spare 4 WS13 - CLR Asst. TATIC
1.1.15 6 6 8 10.2.4 607 2.7.1

ODF ODF 308


LAN 1 WS8 - SUP ACAMS
LAN 7 504 2.4.2
Switch 7
Switch 3 2
604 WS7 - SUP TATIC
2.4.1
SFP SFP
25 7 7 9
LC LX OF 343 OF 363 LC LX 3 Laser Printer
8 8 313 9.1
1.1.16.1 10.2.5.1
4 WS12 - TWR Asst. ACAMS
506 2.6.2
OF 2
1.1.16 8 10.2.5 5 606 WS11 - TWR Assit. TATIC
to OF 352 OF 2 2.6.1
TWR 309
LAN LAN 1 WS4 - GND ACAMS
7 502 2.2.2
Switch 4 Switch 8
SFP SFP 2 WS3 - GND TATIC
25 9 9 9 602 2.2.1
LC LX OF 344 OF 364 LC LX
10 10
1.1.17.1 10.2.6.1 3 QDC 10 - Spotlights NA1
311 6.1.2
11 11
1.1.17 spare spare 10.2.6
12 12
1.1.27.1 10.2.7

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 26
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.4 Contoller Working Position Cabling

ACAMS | Standard CWP – Cabling


ACAMS TATIC

Monitor Monitor
2.x.1.2 2.x.2.2

PTT Prefix Prefix Speakers Prefix Prefix


2.x.1.4 110 111 2.x.3.4 210 211
Prefix Prefix Prefix
131 DP USB 310 311 DP USB

XLR Prefix USB Jack


Workstation Workstation
130
PC PC
Adapter cable USB
2.x.1.1 2.x.2.1
LAN USB USB LAN

Prefix Prefix Prefix Prefix


100 101 KVM 201 200
Switch USB
2.x.3.1
USB
LAN Prefix Prefix Prefix
LAN
301 302 303
Port
selector
2.x.3.2 2.x.3.3

CWP Cable
Note Remarks
Controller working position Prefix
a. Position 1 TWR TW1 2 ACAMS Monitors
CWP cabling is Position 2 GND GN1 --
identified by its cable Position 3 CLR CL1 --
prefix followed by a Position 4 SUP SUP --
number as described on Position 5 SO SO --
the diagram; Position 6 TWR 2 TW2 --
Position 7 TWR Asst. TWA no ACAMS
b. Position 8 GND 2 GN2 --
x = Position Number Position 9 GND Asst. GNA no ACAMS
Position 10 CLR Asst. CLA no ACAMS
Position 11 Coord. COR --
Position 12 TCMS TCM no TATIC

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 27
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Standard CWP – Power cabling

Prefix
115 Monitor
2.x.1.2

ACAMS
Prefix Prefix
PSU Workstation
105 105A
2.x.1.1.1 PC
PDU 2.x.1.1

UPS
220V
Prefix
215 Monitor
2.x.2.2

TATIC
Prefix Prefix
PSU Workstation
205 205A
2.x.2.1.1 PC
2.x.2.1

CWP Cable
Note Remarks
Controller working position Prefix
a. Position 1 TWR TW1 2 ACAMS Monitors
CWP cabling is Position 2 GND GN1 --
identified by its cable Position 3 CLR CL1 --
prefix followed by a Position 4 SUP SUP --
number as described on Position 5 SO SO --
the diagram; Position 6 TWR 2 TW2 --
Position 7 TWR Asst. TWA no ACAMS
b. Position 8 GND 2 GN2 --
x = Position Number Position 9 GND Asst. GNA no ACAMS
Position 10 CLR Asst. CLA no ACAMS
Position 11 Coord. COR --
Position 12 TCMS TCM no TATIC

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 28
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Assistant CWP – Cabling

TATIC

Prefix
215 Monitor
2.x.2.2
PDU
Prefix Prefix
210 211
UPS
DP USB
220V
Prefix Prefix Prefix
PSU Workstation LAN
205 205A 200 LAN
2.x.2.1.1 PC
2.x.2.1
USB USB

Prefix Prefix
302 303

2.x.3.2
2.x.3.3

CWP Cable
Note Remarks
Controller working position Prefix
a. Position 1 TWR TW1 2 ACAMS Monitors
CWP cabling is Position 2 GND GN1 --
identified by its cable Position 3 CLR CL1 --
prefix followed by a Position 4 SUP SUP --
number as described on Position 5 SO SO --
the diagram; Position 6 TWR 2 TW2 --
Position 7 TWR Asst. TWA no ACAMS
b. Position 8 GND 2 GN2 --
x = Position Number Position 9 GND Asst. GNA no ACAMS
Position 10 CLR Asst. CLA no ACAMS
Position 11 Coord. COR --
Position 12 TCMS TCM no TATIC

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 29
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Main TWR CWP – Cabling


ACAMS

ALCMS
Monitor 1 Monitor 2 Monitor
2.x.1.2 2.x.1.3

PTT TW1 TW1 TW1 TW1 Speakers


2.x.1.4 110 111 120 121 2.x.3.4

TW1 TW1 TW1


131 DP USB DP USB 310 311
XLR TW1 USB Jack
Workstation
130
PC
Adapter cable USB
2.x.1.1
USB USB LAN

TW1 TW1 TW1


302 303 100

2.x.3.2
2.x.3.3 LAN

CWP Cable
Note Remarks
Controller working position Prefix
a. Position 1 TWR TW1 2 ACAMS Monitors
CWP cabling is Position 2 GND GN1 --
identified by its cable Position 3 CLR CL1 --
prefix followed by a Position 4 SUP SUP --
number as described on Position 5 SO SO --
the diagram; Position 6 TWR 2 TW2 --
Position 7 TWR Asst. TWA no ACAMS
b. Position 8 GND 2 GN2 --
x = Position Number Position 9 GND Asst. GNA no ACAMS
Position 10 CLR Asst. CLA no ACAMS
Position 11 Coord. COR --
Position 12 TCMS TCM no TATIC

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 30
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Main TWR CWP – Power cabling

TW1
125 Monitor 2
2.x.1.3

PDU
TW1
115 Monitor 1 ACAMS
UPS
2.x.1.2
220V

TW1 TW1
PSU Workstation
105 105A
2.x.1.1.1 PC
2.x.1.1

CWP Cable
Note Remarks
Controller working position Prefix
a. Position 1 TWR TW1 2 ACAMS Monitors
CWP cabling is Position 2 GND GN1 --
identified by its cable Position 3 CLR CL1 --
prefix followed by a Position 4 SUP SUP --
number as described on Position 5 SO SO --
the diagram; Position 6 TWR 2 TW2 --
Position 7 TWR Asst. TWA no ACAMS
b. Position 8 GND 2 GN2 --
x = Position Number Position 9 GND Asst. GNA no ACAMS
Position 10 CLR Asst. CLA no ACAMS
Position 11 Coord. COR --
Position 12 TCMS TCM no TATIC

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 31
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | TCMS CWP – Cabling

ACAMS

TCM
115 Monitor
2.x.1.2
Speakers
PDU 2.x.3.4
TCM TCM
110 111 TCM TCM
UPS DP USB
310 311
220V Jack
TCM TCM USB
PSU Workstation
105 105A
2.x.1.1.1 PC TCM
LAN
2.x.1.1 100 LAN
USB USB
TCM TCM
302 303

2.x.3.2
2.x.3.3

CWP Cable
Note Remarks
Controller working position Prefix
a. Position 1 TWR TW1 2 ACAMS Monitors
CWP cabling is Position 2 GND GN1 --
identified by its cable Position 3 CLR CL1 --
prefix followed by a Position 4 SUP SUP --
number as described on Position 5 SO SO --
the diagram; Position 6 TWR 2 TW2 --
Position 7 TWR Asst. TWA no ACAMS
b. Position 8 GND 2 GN2 --
x = Position Number Position 9 GND Asst. GNA no ACAMS
Position 10 CLR Asst. CLA no ACAMS
Position 11 Coord. COR --
Position 12 TCMS TCM no TATIC

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 32
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Printer - Cabling


Tower

QDC15

LAN Console
Switch 7 PDU
3
313 Printer 1248
UPS
9.1
220V
10.2.5

ACAMS | Signal Light Gun - Power cabling


Tower

Console
PDU
Light gun
1249
charger
UPS
220V
12.1.2

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 33
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.5 Tower Interface - QDC15

ACAMS | Tower Interface - OF/LAN Switches QDC15 - Layout

1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
V1- V1+ V2- V2+ V1- V1+ V2- V2+ V1- V1+ V2- V2+ V1- V1+ V2- V2+
PWR 1 Fault PWR 2 PWR 1 Fault PWR 2 PWR 1 Fault PWR 2 PWR 1 Fault PWR 2

9 10 9 10 9 10 9 10

SW 5 SW 6 SW 7 SW 8
7 8 7 8 7 8 7 8

1/2 3/4 7/8 5/6 9/10 11/12


5 6 5 6 5 6 5 6

SM Optic fiber connectors


3 4 3 4 3 4 3 4

1 2 1 2 1 2 1 2

IGS-10020MT IGS-10020MT IGS-10020MT IGS-10020MT

ODF to
technical
room X220 X220
A X24A B X24B
- + - +
DC 24V DC 24V

F2 F4
PSU 1 PSU 2
NL ++ -- NL ++ --
PE

PE

F1 TSP 090-124 F3 TSP 090-124

115-240 VAC 115-240 VAC


PE N L PE N L

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 34
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Tower Interface - LAN Switches - QDC15 Power

UPS 220V

X 220 A X24 A
+
bk br + - V1 LAN
DJ rd
bl bl PSU 1 + Switch 5
F1 24V F2 - V2 10.2.3
3 C2 1A
1155
L + rd +
N - - V1
- bk bk LAN
+ Switch 6
wh gn PE
10.2.1 - V2 10.2.4

+
- V1 LAN
X 220 B X24 B Switch 7
+
bk br + - V2 10.2.5
DJ rd
bl bl PSU 2
F3 F4 +
24V
C2 1A - V1 LAN
3
1156
L + + Switch 8
rd
N - - V2
- bk bk 10.2.6
wh gn PE
10.2.2

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 35
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.6 ATIS

ACAMS | ATIS - Cabling


ACAMS Rack

TB1 TB3
LAN
8 VOIP1 A.S.U. Radio 1 1 to MDF/DG
Switch 1 108 810
TX 2 2
1.1.14 ATIS
Switchover
Unit
8 VOIP2 Audio 1 1
LAN 208 811
Switch 3 1.1.25
9 LAN Audio 2 2
1.1.16 209 812

ACAMS Rackmount
Server 3 Audio 3 Sound Bar
813
1.1.3 (green)

ACAMS
Server 4 Audio 4
814
1.1.4 (green) 1.1.11

ACAMS | ATIS - Signal routing


Technical Room

ACAMS Rack ATIS TX


Local
Infrastructure
810 TB1 TB3 460
AF 1 1 ATIS Rack
Radio
A.S.U Jump
TX PTT 2 2 A.S.U
W5
1.1.25 DB37
F

Recording

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 36
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.7 INTRAER

ACAMS | INTRAER Network connectivity


Technical room

ACAMS Rack

ACAMS Firewall 1 8 8 Firewall 2 ACAMS


LAN
300 LAN
1.1.18 1.1.19
3 3

Network Rack
404 405

Switch to ABV

spare

INTRAER Network
via INFRANET

Telespazio

ACAMS CATS/DCL AMHS SAGITARIO


Support SITA

NTP Sigma TATIC Flow BINTRA


Server (CGNA)

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 37
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.8 ATN BR

ACAMS | ATN BR Network connectivity


Technical room

ACAMS Rack

ACAMS 8 8 ACAMS
LAN Firewall 1 300 Firewall 2 LAN
1.1.18 1.1.19
5 5

422 423

ATN BR Rack n/c *Connections are still to be defined. n/c

Switch Switch

ATN BR
Network

Telespazio

ACAMS AMHS Sagitário


Support

NTP Sigma TATIC BINTRA


Server Flow
(CGNA)

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 38
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.9 INFRANET

ACAMS | INFRANET Network connectivity


Technical room

ACAMS Rack

ACAMS 8 8 ACAMS
LAN Firewall 1 300 Firewall 2 LAN
1.1.18 1.1.19
7 6 4 4 6 7

Network
Rack 406 Switch to 416
GRU
407 417
418
408
VLAN
spare COA

VLAN
n/c n/c
IP phones
*Provision

VLAN
n/c n/c
Cameras
*Provision *Connections are still to
be defined.

GRU
Network
Crash alarm group call

Airport
SCI Cameras
IP Phones

*Provision *Provision

GRU TATIC
COA Positions
*Provision

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 39
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.10 Meteorology

ACAMS | Meteorology System Connectivety


Signal: Met Data

Serial Device 1 TB2 - RS232 -


DB9
2 9 P10
MetData 401A 401 MetData
M F RJ50

1.1.12
Terminal
Serial Device 2 Server
2
MetData 401B

1.1.13

Signal: Brightness Feedback

Serial Device 1 TB2 - RS232 -


Brightness 5 8 DB9 P6 Brightness
400A 400
Feedback F M RJ50 Feedback

1.1.12
Terminal
connection
Alternative

Serial Device 2 Server


Brightness 5
*400A
Feedback
*400A is connected manually to
1.1.13 port 5 of serial device 1 or 2

Signal: Met Report *Provision

Serial Device 1 TB2 - RS232 -


DB9
3 7 Pxx
MetData 403A 403 n/c MetReport
M F RJ50

1.1.12
Terminal
Serial Device 2 Server
3
MetData 403B
*Connection still
1.1.13 to be defined.

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 40
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Aviation barometer - Cabling

AviMet
Console
Weather Panel Display PDU
WID513
8.1.1
UPS 220V
RS485 24V DC

J10 R- R+ - + 1260
4 5 1260A
wh 24V DC
bk PSU
gn ye bl rd 8.1.3

450
6 8 7 9
DB9 F

PTB330
Barometer

8.1.2

ACAMS | Aviation barometer – DIP Switches

On
PTB330
On
DIP switches S1
On
Configuration
On

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 41
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.11 NAVAIDS

ACAMS | NAVAIDS Link


ILS: LOC / GL / DME
Technical room
ACAMS Rack NAVAIDS Rack
Serial TB1 RCSI 447
Device 1
9 DB9
NAVAIDS 481A 3
481 481C
4 F M
5 DB9
1.1.12 ‘Y cable’ RS422
DB9 F M
481D
Serial F M
481E
Device 2
9 DG1 Tower
NAVAIDS 481B Interlock
Assembly
14.1
1.1.13 V13
TB1 TB30 480 314
ACAMS
LAN

31
467 481F CTU 443
32

ILS: DVOR / DME


Technical room
ACAMS Rack NAVAIDS Rack
Serial TB1 RCSI 447
Device 1
NAVAIDS 10 470A 8 DB9
470 RS232
1.1.12 F M

Serial
Device 2
NAVAIDS 10 470B

1.1.13

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 42
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | NDB Monitoring - Circuit


Technical room

ACAMS Rack NAVAIDS Rack

NA 1
NDB Monitor
DI 1
Input
X102 TB1 TB1
2 Carrier Alarm
11
1.1.26.3
2a 10 NC
wh wh
C NO

14 12 +A1 9
n/c
N0 NC 24 V
K5 Coil bk wh Modulation Alarm
8
11 -A2 n/c
C
R1
7 NC
330Ω 491 492
C NO
6
2b or 9b or
wh/or wh/or
bk bk
+28V
1 bl 9a bl 5
0V
wh/bl wh/bl
0V
(24V)
Screw
SAK Krone
terminal

Crash alarm and I/O Assembly

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 43
Client:
Project

Section:
Document:

© ACAMS AS
6.12 Interlock
CISCEA

ACAMS | Interlock Assembly – Internal layout


X220A X24A
Guarulhos International Airport

DO DI
NA 1
Standard Tower Installation Manual

1 1

EQUIPMENT CABLING AND WIRING


DC 24V 3 2 1
NA 4010 M 2801 M 1801
F2
8 7 6 5
MY2K
PSU 1

L
N
PE
+++ --- 0 1 0 1 0 1
K 01
F21 TCL 060-124
24V DC
2 3 2 3 2 3 12 11 10 9

4 5 4 5 4 5 4 14 13
115-240 VAC

6 7 6 7 6 7

Document ID:
Date:
44 Page:
25.05.2022
20300-0304-B01
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Interlock Assembly – Power


10/28 Interlock Assembly

X220A X24A
1265
+ rd
Console
Interlock
NA1
socket Circuit
PSU1
strip +
3 F1 24V F2
rd 0-6
- bk 1-4
UPS
220V br L
14.1.1
bl N + rd +24 V
gn PE -
- bk bk 0V (24V)
14.1.2.1

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 45
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS |Interlock – Command circuit to CTU


10/28 Interlock Assembly

NA 1
DO 1 10 28
RWY 10
0 bk

wh
Selection
RWY 28 switch
3 bk
wh

X24A

rd +24 V

DI 1 RWY 10
RWY 10
0 bl bk rd +24 V
Lights
RWY 28
3 bl bk rd +24 V
RWY 28
bl/wh

or/wh
*Cable 480 is
connected directly
to the CTU RWY 12 1 5 4 8 14
Selector PCB. K1
The CTU Key RESET SET
switch is disabled.
Relay
9 10 11 13

br/wh
bk 0V
480
bk 0V

bk 0V
CTU RWY
443 Select

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 46
Client:
Project

Section:
Document:

© ACAMS AS
CISCEA

6.13 Crash Alarm

ACAMS | Crash alarm and I/O Assembly - Layout


X24A X48A X101 X102
- + - +
Guarulhos International Airport

X220B

X220A
DC 24V DO DI 12 12 12 12 12 DC 24V
Standard Tower Installation Manual

EQUIPMENT CABLING AND WIRING


NA 1 1 1 11 11 11 11 11

NA 4010 M 2801 M 1801 14 14 14 14 14


F2 F4

NO
NO
NO
NO
NO
LT

PE
PE
0V
0V

LQ

PSU 1 ++ -- 0 1 0 1 0 1 PSU 2 +-

K1
K2
K3
K4
K5
F1 F3
TSP 090-124 TSP 090-124
Command
Command
Command
NDB Alarm

2 3 2 3 2 3

24V
24V
24V
24V
24V
4 5 4 5 4 5
- - - - -
6 7 6 7 6 7 + + + + +
115-240 VAC 115-240 VAC
PE N L PE N L Crash NDB
Beacon
Alarm IK

Document ID:
Date:
47 Page:
25.05.2022
20300-0304-B01
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Crash alarm and I/O Assembly – Power


ACAMS Rack
X24 A
1036
NA1
+ rd
+ rd 0-6
PSU1 F2
6 3 F1 - bk 1-4
24V
br L
PDU 2 bl N - bk
gn PE
UPS 1.1.26.3
X220 A 1.1.26.2.1
220V
SAK SAK
Command
Socket X48 A circuits
strip
1037

+ rd

PSU2 F4
7 3 ‘ F3 24V
br L + rd +48 V
bl N - bk - bk 0V (48V)
gn PE
1.1.21
X220 B 1.1.26.2.2
SAK SAK

Crash Alarm and I/O Assembly

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 48
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Crash Alarm - Command circuit


Technical room Tower
ACAMS Rack Console
Crash Alarm 11.1.1
NA 1 +48V
Push button
1.1.26.3
NO
DI 1 + -
X48A TB2 TB3 TB30
Output
0 445 460 444
rd
K1 1 1 11 5
bl bl
wh/bl ab ab ab wh/bl
wh rd
+A1 11 Jump
24 V C
Coil
14 or 2 12 6 or
-A2 12 N0
NC 3 wh/or ab ab ab wh/or
bk wh
MDF / DG
Krone
---
Local
0V
(24V) Infrastructure SCI – Fire Station
MDF/DG QDC20
Siren
TB X101
449
gn 4 14 255 2
wh/gn ab ab ab
+

Jump
Siren
circuit
0V 2 br 3 13 254 1
(48V)
bk
wh/br ab ab ab
-

SAK Krone Krone SAK

Crash alarm and I/O Assembly

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 49
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | SCI Crash alarm - QDC20 - Layout

K1 12
X101
11

14

NO
L1 L2 L3 13NO A1

K2
F1 T1 T2 T3 14NO A2

- +

24V
-
+

ACAMS | SCI Crash alarm – Siren Circuit


SCI – Fire Station

MDF/DG QDC20 – Siren command enclosure

TB X101 K2
449
from - 255 -
ACAMS -A2 12 14 T1 T3 Siren
Rack A1
NC N0
48 V 220 V
--- Coil Coil K1
Crash 11 A2 L1 L3
256 + +A1 C
Alarm
Assembly +

F1
C10
L
220V
N

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 50
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.14 Backup Radio

ACAMS | TWR Backup Radio - Cabling


Tower TWR Position Tower
Roof top

Controller Surge TWR


Arrestor VHF Aerial
13.1.2
Antenna
Console DB15 M
PDU
1242 901
Technical
UPS 220V MDF/DG
RJ45 room
V5
QFA-008 TB30 TB1
DJ 04 Mini VHF Facilities 1 1

DB15 M
1240 UPS 1241 Transceiver 900 462
Recording
13.1.4 13.1.1

ACAMS | GND Backup Radio - Cabling


Tower GND Position Tower
Roof top

Controller Surge GND


Arrestor VHF Aerial
13.2.2
Antenna
Console DB15 M
PDU
1245 904
Technical
UPS 220V MDF/DG
RJ45 room
V5
QFA-008 TB30 TB1
Facilities

DJ 11 Mini VHF 2 2
DB15 M

1243 UPS 1244 Transceiver 903 462


Recording
13.2.4 13.2.1

ACAMS | Airport Backup Radio - Cabling


Technical
MDF/DG
room
Console
TB30
PDU
UPS 4
911 462
220V Recording
NAV Brasil
Radio

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 51
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.15 Access Control

ACAMS | Tower access control – QDC13 Layout

ON
Delay
OFF adjustment

1-

Solid state
+2
PSU 1
relay
K2
+4 3- Magnectic lock power supply
Network
Camera
PoE
Midspan

110-240 V AC DC 12V

X220 A X101 X102


a a

PE
F1 N N L L + - + - - + K1
12V

1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4

b b
Keyboard
Keyboard

Bell
RS232
12V aux
Lock

Lock

Lock
Open

Open
output

Green LED
Red LED

Relay input
Open

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 52
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Access control QDC13 - Power


QDC13 - Access control enclosure
UPS 220V X220 A
(TB1)

br bk L PSU 1
DJ br
Magnetic lock
bk N 7.1.2.1
F1 bl
C6
bk L
3
1153 bl SAK N 3 PoE Midspan
wh gn PE 7.1.4

br bl gn

220V

Main

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 53
ACAMS | Tower Access control circuit
QDC13 - Access control enclosure QDC15
Data In
3 310 ACAMS LAN
220V AC PoE Midspan Data & Power
310A
Client:

7.1.4
Project

Out

Section:
UPS X102 (TB3) 437 Network Camera
Document:

K1 12V Relay K2 2 2
3+ rd wh/or +12V LAN+PoE

© ACAMS AS
Solid state R3 1,2kΩ 4 4
-A2 NO 11 4- bk or OUT (0V)
relay 1 1
wh/bl 0V
CISCEA

connector
NO 3 3
+A1 14 2+ 1- bl IN
7.2.1
SAK
439
X101 438
wh wh
220V AC (TB2) 434A 434B Access Control Panel
bk rd wh wh wh wh wh wh Connector(s) Bell push EXIT
Guarulhos International Airport

8 button push
F M
Standard Tower Installation Manual

EQUIPMENT CABLING AND WIRING


3 NO NO button
Open + wh wh
7 7 NC
command wh 7.3.2 7.2.3
input - wh wh rd rd
3 12 9 431C
12V aux or rd 435 435A + Keypad
4 11 8 431B
jump bk 436 436A -
1 4 6
PSU 1 or Fo Break-glass
2 8 7
Magnetic wh/or Co (0V) emergency
11 1 1 switch
or gn TX
lock *Cable 440 DB9 F 12 2 2
for keypad 440 bl br RX NC
setup wh/or 13 5 3
RS232 wh/gn gnd 7.3.1 7.2.4
wh/bl 6
gn wh/br
LED 14a LED Assembly Emergency key
433 SAK 433A
commands rd n/c R2 14b 14 switch
2,2kΩ D4 wh/bl (441B) bl
441A
10b 13
3,3kΩ D3 bl (441C) 441D rd

SAK Intenal
R1

Document ID:
Date:
Page:
9 15 D2 D5
bk wh
NC
jump 432E 432F 7.3.3

54
10
bk 432B 432D bk
Open 5 9
- rd/bk bk 432A 432C bk 7.3
command transparent 6

25.05.2022
+ rd rd 431A
output
rd 431C

20300-0304-B01
7.1.2.1 10a
rd 431 bl +
C1
SAK D1 430 Magnetic lock
2,2µF
bk 432 br - 7.2.2
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.16 Tower Lighting

ACAMS | Common ceiling lights - Electrical


Tower
Dimmer IDB-01 Ceiling lights
panel
Dimmer 1 1221 X101 1222 A
1220 GND 1222
D1
1
1 bk L
7 to 10
7 bl N 1222 B
D2
Dimmer 2 1223 A
TWR 1223
D3
L N 2
2 bk L

Com. 220V bl N 1223 B


QLA-004 D4
DJ 10
Dimmer 3 1224 A
CLR 1224
D5
3
3 bk L

bl N 1224 B
D6
Dimmer 4 1225 A
Stairs 1225
D7
4
4 bk L

bl N 1225 B
D8
Dimmer 5 1226 A
SUP 1226
D9
5
5 bk L

bl N 1226 B
D10
Dimmer 6 1227 A
Room 1227
D11
6
6 bk L

bl N 1227 B
D12

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 55
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Spotlights QDC10 - Layout


X24
A
NA 1 AO AO
1 2
Dimmer Module 1 NA 4010
NA NA

F2
4010 4010

UDK-04-10 (0-10V)
+ - 0 1 0 1 0 1
Analog IN 1
Analog IN 2
Analog IN 3
Analog IN 4
Signal gnd

A B C D
2 3 2 3 2 3
N N L L LD N N L L LD N N L L LD N N L L LD
4 5 4 5 4 5
12345
| Nº 490 | 10/06/2021 6 7 6 7 6 7

Dimmer Module 2

UDK-04-10 (0-10V)
Analog IN 1
Analog IN 2
Analog IN 3
Analog IN 4
Signal gnd

A B C D
N N L L LD N N L L LD N N L L LD N N L L LD

12345

X220 X220
A B - + X101
DC 24V

PSU 1
NL NN L NL NL NL NL NL NL NL NL
PE
PE

PE

PE

PE

PE

PE

PE

PE

PE

F1 TSP 090-124

123 456 789


10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

115-240 VAC
GND TWR TWR CLR CLR SUP Room Stairs
PE N L
Asst. Asst.

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 56
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Spotlights QDC10 - Power

QDC10 – Spotlights control enclosure


UPS 220V
X220 A X220 B X24A
1150
+ rd
bk bk
DJ bl bl
PSU 1
F1 24V F2
C6 1A NA 1
3
br L br
+ 0-6
bl N bl
- bk - 1-4
wh PE gn 6.1.5 6.1.2

X101

N N
PE PE
Spotlights power
distribution
circuit

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 57
ACAMS |Spotlights - Command circuit
QDC10 – Spotlights control enclosure
Tower Dimmer Module 1 5.1.4.1
Client:
Project

4 bk 1 Signal Gnd

Section:
UPS A B C D
AO
Document:

220 V 0 bk 2 Analog IN 1

© ACAMS AS
1
1 bk 3 Analog IN 2
2 bk 4 Analog IN 3
X101
1150
CISCEA

Dimmer Dimmer Dimmer Dimmer


3 bk 5 Analog IN 4
Output Output Output Output
PE N N L L LD N N L L LD N N L L LD N N L L LD

PE N L PE
L br br br 12
gn bl bk br
bl bl bl
Guarulhos International Airport

N
X220 9
br
Standard Tower Installation Manual

NA 1

EQUIPMENT CABLING AND WIRING


A 6
br

F1 3
br

Dimmer Module 2 5.1.4.2


X220 4 bk 1 Signal Gnd
B AO A B C D
0 bk 2 Analog IN 1
2
1 bk 3 Analog IN 2
2 bk 4 Analog IN 3
Spotlighs - Power distribution circuit

gn bl bk Dimmer Dimmer Dimmer Dimmer


3 bk 5 Analog IN 4
Output Output Output Output

5.1.3 PE N N L L LD N N L L LD N N L L LD N N L L LD

PE

Document ID:
Date:
Page:
L br br br 24
br
N bl bl bl

58
21
br
18

25.05.2022
br
15

20300-0304-B01
br
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Spotlight rails - Power distribution


QDC10 – Spotlights control enclosure Intermediate Spotlight
connections Rails
X101

1170A
Dimmer 1
module 1 PE gn gn wh
2 GND
N bl bl bl 1170 3x 1,5mm²
L1
3
A LD br br bk

4 n/c
PE gn wh
5 n/c TWR
N bl bl 1171 3x 1,5mm²
L2
6
B LD br bk bk

7
PE gn gn wh
8 TWR Asst.
N bl bl bl 1172 3x 1,5mm²
L1
9
C LD br br bk

10 n/c
PE gn wh
11 n/c CLR Asst.
N bl bl 1173 3x 1,5mm²
L2
12
D LD br bk bk

Dimmer 13 n/c
module 2 PE gn wh
14 n/c CLR
N bl bl 1174 3x 1,5mm²
L3
15
A LD br rd bk
1172A
16
PE gn wh
17 SUP
N bl bl 1175 3x 1,5mm²
L1
18
B LD br bk

19
PE gn wh
20 Room
N bl bl 1176 3x 1,5mm²
L1
21
C LD br bk

22
PE gn wh
23 Stairs
N bl bl 1177 3x 1,5mm²
L1
24
D LD br bk

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 59
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

6.17 Tower Sunshade Blinds

ACAMS | Sunshade blinds QDC 11 - Layout

UP DOWN Selection

NA 1 DO1 DO2 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
M M
NA 4010
2801 2801 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14
K 10
K 11
K 12
K 13
K 14
K 15
K 16
K 17
K 18
K 19
K 20
K 21
K 22
K 23
K 24
0 1 0 1 0 1
K1
K2
K3
K4
K5
K6
K7
K8
K9

2 3 2 3 2 3
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V
24V

24V
24V
24V
24V
24V
24V
24V
24V
4 5 4 5 4 5
- - - - - - - - - - - - - - - - - - - - - - - -
6 7 6 7 6 7 + + + + + + + + + + + + + + + + + + + + + + + +

X220 X220 X24


A B A X101
- +
DC 24V

F2
PSU 1
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
1
2
3
4
5
6
7
8
9

F1 ++ --
PE

N
L

TSP 090-124

115-240 VAC
L2 Down

L2 Down

L2 Down

L2 Down

L2 Down

L2 Down

L2 Down

L2 Down
Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral

Neutral
L1 Up

L1 Up

L1 Up

L1 Up

L1 Up

L1 Up

L1 Up

L1 Up

PE N L
PE

PE

PE

PE

PE

PE

PE

PE

1 2 3 4 5 6 7 8
Motor number

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 60
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Sunshade blinds QDC11 - Power

QDC11 – Sunshade blinds control enclosure

UPS 220V 1151 X220B

bk
bl L L 220V
DJ
X24A Command
F1 circuit
3 C6 + rd +
+24V
-
L br br
PSU 1
0V
F2
N bl Phase bl 24V
X220A 1A
Filter NA1
+
wh PE gn 0-6
-
- bk 1-4
5.1.5 5.1.2

Motors
power
distribution
circuit
X101

N N
PE PE

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 61
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS | Sunshades blinds – Command circuit principle


QDC11 – Sunshades blinds control enclosure

x = Motor number
NA 1
(Sunshade blinds 1 to 8)
DO 1
L
Output
‘x-1’
+A1 11
Sunshade C Selection Relays:
24 V K9 to K16
blind ‘x’ Coil
Selection 12
-A2 NC 14
N0
0V (24V)
X101

DO 2 PE
Sunshade
Output 6 N
Blinds
+A1 11
UP 24 V
C Up - Relays:
command Coil K1 to K4
12
-A2 NC 14
N0 L1
0V (24V) UP Motor ‘X’

Output 7

+A1 11
DOWN 24 V
C Down - Relays:
command Coil K5 to K8
12
-A2 NC 14
N0 L2
0V (24V) DOWN

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 62
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS |Sunshade blinds QDC11 - Command circuit


NA 1 L QDC11 – Sunshades blinds control enclosure
K9 K1 K5
0 A1 A2
0V
A1 A2
0V
A1 A2
0V

12 NC 12 NC 12 NC
11 11 X101 11 X101
C 14 NO C 14 NO L1 1 1 C 14 NO L2 2 1
22 NC 22 NC
21 X101 21 X101
C 24 NO L1 5 2 C 24 NO L2 6 2

K10
1 A1 A2
0V

12 NC
11
C 14 NO

K11 K2 K6
2 A1 A2
0V
A1 A2
0V
A1 A2
0V

12 NC 12 NC 12 NC
11 11 X101 11 X101
DO 1 C 14 NO C 14 NO L1 9 3 C 14 NO L2 10 3
22 NC 22 NC
21 X101 21 X101
C 24 NO L1 13 4 C 24 NO L2 14 4

K12
3 A1 A2
0V

12 NC
11
C 14 NO

K13 K3 K7
4 A1 A2
0V
A1 A2
0V
A1 A2
0V

12 NC 12 NC 12 NC
11 11 X101 11 X101
C 14 NO C 14 NO L1 17 5 C 14 NO L2 18 5
22 NC 22 NC
21 X101 21 X101
C 24 NO L1 21 6 C 24 NO L2 22 6

K14
5 A1 A2
0V

12 NC
11
C 14 NO

K15 K4 K8
6 A1 A2
0V
A1 A2
0V
A1 A2
0V

12 NC 12 NC 12 NC
11 11 X101 11 X101
C 14 NO C 14 NO L1 25 7 C 14 NO L2 26 7
22 NC 22 NC
21 X101 21 X101
C 24 NO L1 29 8 C 24 NO L2 30 8

K16
7 A1 A2
0V

12 NC
11
DO 2 C 14 NO

6
7
6.1.3 Selection Relays UP Relays Motor DOWN Relays Motor

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 63
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

ACAMS |Sunshade blinds – Power distribution


QDC11 – Sunshades Blinds control enclosure
Sunshade
Command X101 Blind
Motor
circuit 1
connector
PE gn
2
gn/yw
N bl
3
bl
1191 4x 1mm² Motor 1
L2 DOWN wh bk
1 L1 UP wh 4 br
5
PE gn
6
gn/yw
N bl
7
bl
1192 4x 1mm² Motor 2
L2 DOWN wh bk
2 L1 UP wh 8 br
9
PE gn
10
gn/yw
N bl
11
bl
1193 4x 1mm² Motor 3
L2 DOWN wh bk
3 L1 UP wh 12 br
13
PE gn
14
gn/yw
N bl
15
bl
1194 4x 1mm² Motor 4
L2 DOWN wh bk
4 L1 UP wh 16 br
17
PE gn
18
gn/yw
N bl
19
bl
1195 4x 1mm² Motor 5
L2 DOWN wh bk
5 L1 UP wh 20 br
21
PE gn
22
gn/yw
N bl
23
bl
1196 4x 1mm² Motor 6
L2 DOWN wh bk
6 L1 UP wh 24 br
25
PE gn
26
gn/yw
N bl
27
bl
1197 4x 1mm² Motor 7
L2 DOWN wh bk
7 L1 UP wh 28 br
29
PE gn
30
gn/yw
N bl
31
bl
1198 4x 1mm² Motor 8
L2 DOWN wh bk
8 L1 UP wh 32 br

Neutral - Blue STAK 3


Motor connector

Down - Black Connector


Up - Brown

Gound
Green/yellow

Section: EQUIPMENT CABLING AND WIRING Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 64
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

7 CABLE LIST

The ACAMS System cables are identified with a 3 or 4 digit number and for fiber-optic
cables/cords, an ‘OF’ prefix is specifically added. Functionally related cables can be identified
with the same number followed by a letter or number suffix.

7.1 Master Cable List

Cable
From To Type Remarks
ID
100-199 | Central Equipment - LAN 1 (Blue cabling)
1.1.14 1.1.1
101 RJ45 LAN
LAN Switch 1 P1 ACAMS Server 1 P1 CAT6 --
1.1.14 1.1.3
102 RJ45 LAN
LAN Switch 1 P2 ACAMS Server 3 P1 CAT6 --
1.1.14 1.1.5
103 RJ45 LAN
LAN Switch 1 P3 TATIC Server 1 P1 CAT6 --
1.1.14 1.1.7
104 RJ45 LAN
LAN Switch 1 P4 TATIC Server 3 P1 CAT6 --
1.1.14 1.1.4
105 RJ45 LAN
LAN Switch 1 P5 ACAMS Server 4 iLO CAT6 --
1.1.14 1.1.8
106 RJ45 LAN
LAN Switch 1 P6 TATIC Server 4 iLO CAT6 --
1.1.14 1.1.12
107 RJ45 LAN
LAN Switch 1 P7 Serial Device Nport 1 LAN CAT6 --
1.1.14 1.1.25
108 RJ45 LAN
LAN Switch 1 P8 ASU VoIP 1 CAT6 --
109
-- -- -- *Provision
110
-- -- -- *Provision
1.1.14 1.1.18
111 RJ45 LAN
LAN Switch 1 P11 Firewall 1 P1 CAT6 --
1.1.14 1.1.19
112 RJ45 LAN
LAN Switch 1 P12 Firewall 2 P1 CAT6 --

1.1.15 1.1.2
151 RJ45 LAN
LAN Switch 2 P1 ACAMS Server 2 P1 CAT6 --
1.1.15 1.1.4
152 RJ45 LAN
LAN Switch 2 P2 ACAMS Server 4 P1 CAT6 --
1.1.15 1.1.6
153 RJ45 LAN
LAN Switch 2 P3 TATIC Server 2 P1 CAT6 --
1.1.15 1.1.8
154 RJ45 LAN
LAN Switch 2 P4 TATIC Server 4 P1 CAT6 --
1.1.15 1.1.1
155 RJ45 LAN
LAN Switch 2 P5 ACAMS Server 1 iLO CAT6 --
1.1.15 1.1.5
156 RJ45 LAN
LAN Switch 2 P6 TATIC Server 1 iLO CAT6 --

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 65
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1.1.15 1.1.9.1
157 RJ45 LAN
LAN Switch 2 P7 SAN Controller 1 CAT6 --

200-299 | Central Equipment - LAN 2 (Yellow cabling)


1.1.16 1.1.1
201 RJ45 LAN
LAN Switch 3 P1 ACAMS Server 1 P2 CAT6 --
1.1.16 1.1.3
202 RJ45 LAN
LAN Switch 3 P2 ACAMS Server 3 P2 CAT6 --
1.1.16 1.1.5
203 RJ45 LAN
LAN Switch 3 P3 TATIC Server 1 P2 CAT6 --
1.1.16 1.1.7
204 RJ45 LAN
LAN Switch 3 P4 TATIC Server 3 P2 CAT6 --
1.1.16 1.1.2
205 RJ45 LAN
LAN Switch 3 P5 ACAMS Server 2 iLO CAT6 --
1.1.16 1.1.6
206 RJ45
LAN Switch 3 P6 TATIC Server 2 iLO LANCAT6 --
1.1.16 1.1.13
207 RJ45 LAN
LAN Switch 3 P7 Serial Device Nport 2 LAN CAT6 --
1.1.16 1.1.25
208 RJ45 LAN
LAN Switch 3 P8 ASU VoIP 2 CAT6 --
1.1.16 1.1.25
209 RJ45 LAN
LAN Switch 3 P9 ASU LAN CAT6 --
210
-- -- -- *Provision
1.1.16 1.1.18
211 RJ45 LAN
LAN Switch 3 P11 Firewall 1 P2 CAT6 --
1.1.16 1.1.19
212 RJ45 LAN
LAN Switch 3 P12 Firewall 2 P2 CAT6 --

1.1.17 1.1.2
251 RJ45 LAN
LAN Switch 4 P1 ACAMS Server 2 P2 CAT6 --
1.1.17 1.1.4
252 RJ45 LAN
LAN Switch 4 P2 ACAMS Server 4 P2 CAT6 --
1.1.17 1.1.6
253 RJ45 LAN
LAN Switch 4 P3 TATIC Server 2 P2 CAT6 --
1.1.17 1.1.8
254 RJ45 LAN
LAN Switch 4 P4 TATIC Server 4 P2 CAT6 --
1.1.17 1.1.3
255 RJ45 LAN
LAN Switch 4 P5 ACAMS Server 3 iLO CAT6 --
1.1.17 1.1.7
256 RJ45 LAN
LAN Switch 4 P6 TATIC Server 3 iLO CAT6 --
1.1.17 1.1.9.2
257 RJ45 LAN
LAN Switch 4 P7 SAN Controller 2 CAT6 --
1.1.17 1.1.26.1
258 RJ45 LAN
LAN Switch 4 P8 Crash Alarm - NA1 CAT6 --

300-399 | System LAN and Optical fibres


1.1.18 1.1.19
300 RJ45 LAN
Firewall 1 P8 Firewall 2 P8 CAT6 --

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 66
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1.1.14 1.1.15
301 RJ45 LAN
LAN Switch 1 P22 LAN Switch 2 P22 CAT6 --
1.1.16 1.1.15
302 RJ45 LAN
LAN Switch 3 P23 LAN Switch 2 P23 CAT6 --
1.1.15 1.1.17
303 RJ45 LAN
LAN Switch 2 P24 LAN Switch 4 P22 CAT6 --
1.1.14 1.1.17
304 RJ45 LAN
LAN Switch 1 P23 LAN Switch 4 P23 CAT6 --
1.1.14 1.1.16
305 RJ45 LAN
LAN Switch 1 P24 LAN Switch 3 P22 CAT6 --
1.1.16 1.1.17
306 RJ45 LAN
LAN Switch 3 P24 LAN Switch 4 P24 CAT6 --
10.2.3 10.2.4
RJ45 LAN Tower LAN Interface
307
LAN switch 5 P8 LAN switch 6 P7 CAT6 QDC15
10.2.4 10.2.5
RJ45 LAN Tower LAN Interface
308
LAN switch 6 P8 LAN switch 7 P7 CAT6 QDC15
10.2.5 10.2.6
RJ45 LAN Tower LAN Interface
309
LAN switch 7 P8 LAN switch 8 P7 CAT6 QDC15
10.2.3 7.1.4
310 RJ45 LAN
LAN Switch 5 P7 PoE Midspan CAT6 Access Control | LAN
7.1.4 7.2.1
RJ45 LAN Access Control
310A
PoE Midspan Network Camera CAT6 LAN+PoE
10.2.6 5.1.3
311 RJ45
LAN switch 8 P3 QDC10 Spotlights - NA1 LANCAT6 Spotlights | LAN
10.2.4 6.1.3
312 RJ45 LAN
LAN switch 6 P3 QDC11 Sunshades - NA1 CAT6 Sunshades | LAN
10.2.5 9.1
313 RJ45 LAN
LAN switch 7 P3 Printer CAT6 Printer
314
-- -- -- *Interlock Provision
10.2.4 15.1.2
RJ45 LAN Tower PTZ Camera
315
LAN switch 6 P4 PoE Injector CAT6 LAN
15.1.2 15.1.1
RJ45 LAN Tower PTZ Camera
315A
PoE Injector PTZ Camera CAT6 LAN+PoE
10.2.4 15.1.3
RJ45 LAN Tower PTZ Camera
316
LAN switch 6 P5 PTZ Controller CAT6 LAN

3.1.2.1 3.1.2.4
321 RJ45 LAN
QDC1 Switch 11 P1 QDC1 NA11 CAT6 ALCMS *Provision
3.1.3.1 3.1.3.4
322 RJ45 LAN
QDC1 Switch 21 P1 QDC1 NA21 CAT6 ALCMS *Provision
323
-- -- -- ALCMS *Provision

1.1.14.1 1.1.27
OF
Rack ODF - OF1 to Tower 1- OF single
341 LAN switch 1 P25
2 mode LAN to QDC15 Switch 5
1.1.15.1 1.1.27
OF
Rack ODF - OF1 to Tower 3- OF single
342 LAN switch 2 P25
4 mode LAN to QDC15 Switch 6

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 67
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1.1.16.1 1.1.27
OF
Rack ODF - OF2 to Tower 7- OF single
343 LAN switch 3 P25
8 mode LAN to QDC15 Switch 7
1.1.17.1 1.1.27
OF344 Rack ODF - OF2 to Tower 9- OF
LAN switch 4 P25
10 singlemode LAN to QDC15 Switch 8
OF 1.1.14 1.1.27
OF single ALCMS
345 LAN switch 1 P26 Rack ODF - OF to KF 1-2 mode LAN to QDC1 Switch 11
OF 1.1.16 1.1.27
OF single
346 LAN switch 3 P26 Rack ODF - OF to KF 3-4 mode ALCMS *Provision
OF
347 -- -- -- ALCMS *Provision

OF 1.1.27 10.2.7
OF single
351 Rack ODF - OF1 to Tower QDC15 - ODF mode OF1 to Tower (1 to 6)
OF 1.1.27 10.2.7
OF single
352 Rack ODF - OF2 to Tower QDC15 - ODF mode OF2 to Tower (7 to 12)
OF 1.1.27 3.1.4
OF single
353 Rack ODF - OF to KF QDC1 - ODF mode ALCMS *Provision
OF
354 -- -- -- ALCMS *Provision

OF 10.2.7 10.2.3
OF single Tower LAN Interface
361 QDC 15 - ODF 1-2 LAN switch 5 P9 mode QDC15
OF 10.2.7 10.2.4
OF single Tower LAN Interface
362 QDC 15 - ODF 3-4 LAN switch 6 P9 mode QDC15
OF 10.2.7 10.2.5
OF single Tower LAN Interface
363 QDC 15 - ODF 7-8 LAN switch 7 P9 mode QDC15
OF 10.2.7 10.2.6
OF single Tower LAN Interface
364 QDC 15 - ODF 9-10 LAN switch 8 P9 mode QDC15
OF 3.1.4 3.1.2.1
OF single
365 KF QDC1 - ODF 1-2 QDC1 Switch 11 P5 mode ALCMS *Provision
OF 3.1.4 3.1.3.1
OF single
366 KF QDC1 - ODF 3-4 QDC1 Switch 21 P5 mode ALCMS *Provision
OF
367 -- -- -- ALCMS *Provision

OF
371 -- -- -- NAVAIDS *Provision

400 - 499 | External systems & connections


1.1 Vaisala SH95 SH95 Brightness
400
ACAMS Rack TB2-8 Terminal Server P6 RS232 feedback
1.1 1.1.12 or 1.1.13
400A Serial Device Nport 1 or 2 - SH95 Brightness
ACAMS Rack TB2-8
P5 RS232 feedback
1.1 Vaisala SH95
401
ACAMS Rack TB2-9 Terminal Server P12 RS232 SH95 Met Data
1.1 1.1.12
401A
ACAMS Rack TB2-9 Serial Device Nport 1 - P2 RS232 SH95 Met Data

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 68
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1.1 1.1.13
401B
ACAMS Rack TB2-9 Serial Device Nport 2 - P2 RS232 SH95 Met Data
402
-- -- -- Meteorology *Provision
1.1 Vaisala SH95
403
ACAMS Rack TB2-7 Terminal Server P16 RS232 SH95 Met Report
1.1 1.1.12
403A
ACAMS Rack TB2-7 Serial Device Nport 1 - P3 RS232 SH95 Met Report
1.1 1.1.13
403B
ACAMS Rack TB2-7 Serial Device Nport 2 - P3 RS232 SH95 Met Report
1.1.18
RJ45 LAN INFRANET/INTRAER
404
Firewall 1 P3 NAV Switch #1 CAT6 Connection 1
1.1.19
RJ45 INFRANET/INTRAERConnection
405
Firewall 2 P3 NAV Switch #2 LANCAT6 2
1.1.18
406 RJ45 LAN
Firewall 1 P4 NAV Switch #1 CAT6 INFRANET - COA
1.1.18
407 RJ45 LAN
Firewall 1 P6 NAV Switch #1 CAT6 INFRANET - IP Phones
1.1.18
RJ45 LAN INFRANET
408
Firewall 1 P7 -- CAT6 Cameras * Provision

1.1.14
RJ45 LAN Ground Radar
414
LAN Switch 1 P20 -- CAT6 *Provision
1.1.16
RJ45 LAN Ground Radar
415
LAN Switch 3 P20 -- CAT6 *Provision
1.1.19
416 RJ45
Firewall 2 P4 NAV Switch #2 LANCAT6 INFRANET - SISO/COA
1.1.19
417 RJ45 LAN
Firewall 2 P6 NAV Switch #2 CAT6 INFRANET - IP Phones
1.1.19
RJ45 LAN INFRANET
418
Firewall 2 P7 -- CAT6 Cameras * Provision
419
-- -- -- *Provision
1.1
RJ45 LAN IP Phones Recording
420
ACAMS Rack Recorder/VCX CAT6 *Provision
1.1
RJ45 LAN IP Phones Recording
421
ACAMS Rack Recorder/VCX CAT6 *Provision
1.1.18
RJ45 LAN ATN BR 1 Network
422
Firewall 1 P5 ATN BR CAT6 *Provision
1.1.19
RJ45 LAN ATN BR 2 Network
423
Firewall 2 P5 ATN BR CAT6 *Provision

7.1 7.2.2
430
QDC13 - TB2 Magnetic lock 2 wires Access control
7.1 430
431
QDC13 - TB2 to Magnetic lock 1 wire Access control
7.1 7.2.4
431A
QDC13 - TB2 Break-glass switch 1 wire Access control
7.2.4 7.2.3
431B
Break-glass switch Exit push button 1 wire Access control

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 69
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID

7.2.3 7.1
431C
Exit push button QDC13 - TB2 1 wire Access control
7.1 430
432
QDC13 - TB2 to Magnetic lock 1 wire Access control
7.1 7.3.3
432A
QDC13 - TB2 Emergency Key switch 1 wire Access control
7.1 7.3.3
432B
QDC13 - TB2 Emergency Key switch 1 wire Access control
7.1 7.3.3
432C
QDC13 - TB2 Emergency Key switch 1 wire Access control
7.1 7.3.3
432D
QDC13 - TB2 Emergency Key switch 1 wire Access control
7.1 7.3
432E Access Control Panel - LED
QDC13 - TB2 Assembly 1 wire Access control
7.1 7.3
432F Access Control Panel - LED
QDC13 - TB2 Assembly 1 wire Access control
7.1 7.3
433
QDC13 - TB2 Access Control Panel UTP Access control
7.1 7.3.1
433A
QDC13 - TB2 Keypad UTP Access control
7.1 7.3.2
434A
QDC13 - TB3 Bell push button 1 wire Access control
7.1 7.3.2
434B
QDC13 - TB3 Bell push button 1 wire Access control
7.1 7.3.1
435
QDC13 - TB2 Keypad 1 wire Access control
7.1 7.3.1
435A
QDC13 - TB2 Keypad 1 wire Access control
7.1 7.3.1
436
QDC13 - TB2 Keypad 1 wire Access control
7.1 7.3.1
436A
QDC13 - TB2 Keypad 1 wire Access control
7.1 7.2.1 Access control
437
QDC13 - TB3 Network Camera UTP Camera Controls
7.1 7.2.3
438
QDC13 - TB2 Exit push button 1 wire Access control
7.1 7.2.3
439
QDC13 - TB2 Exit push button 1 wire Access control
7.1 n/c (in QDC13) RS232 Access control
440
QDC13 - TB2 Keypad setup UTP Keypad Setup cable
7.1 7.3
441 Access Control Panel - LED Access control
QDC13 - TB2 Assembly UTP *Provision
7.1 7.3
441A Access Control Panel - LED
QDC13 - TB2 Assembly 1 wire Access control
7.1 7.3
441B Access Control Panel - LED Access control
QDC13 - TB2 Assembly 1 wire *Provision

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 70
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
7.1 7.3
441C Access Control Panel - LED
QDC13 - TB2 Assembly 1 wire Access control*Provision
7.1 7.3
441D Access Control Panel - LED
QDC13 - TB2 Assembly 1 wire Access control
442
-- -- -- *Provision
443
-- -- -- *Provision
11.1.1 10.1.1 UTP Crash Alarm
444
Crash Alarm push button QDC12 - TB50 4 pairs Push button
1.1.26 1.1 UTP
445
Crash Alarm Assembly X101 ACAMS Rack TB2 4 pairs Crash Alarm
446
-- -- -- Crash Alarm *Provision

8.1.1 8.1.2
450
AviMet Display Barometer UTP Aviation Barometer

1.1 VCS QDG-ST UTP


460
ACAMS Rack TB3 MDF - DG 20 pairs Rack Analog Interface
Analog Interface
461
-- -- -- *Provision
10.1.1 UTP
462
MDF - DG QDC12 - TB50 50 pairs Tower Analog Interface

1.1 Thales NAVAIDS | DVOR/DME


470
ACAMS Rack TB1 - 8 RCSI 447 RS232 *Provision
1.1.12 1.1 NAVAIDS | DVOR/DME
470A
Serial Device Nport 1 P10 ACAMS Rack TB1 - 8 RS232 *Provision
1.1.13 1.1 NAVAIDS | DVOR/DME
470B
Serial Device Nport 2 P10 ACAMS Rack TB1 - 8 RS232 *Provision
471
-- -- -- NAVAIDS *Provision

14.1 Thales
480
Interlock Assembly CTU 443 -- NAVAIDS *Provision

1.1.26 1.1 UTP


491
Crash Alarm Assembly X102 ACAMS Rack TB1 4 pairs NDB Monitoring
10.1.1
492 NDB Monitor - Alarm UTP NDB Monitoring
QDC12 - TB50
Output 4 pairs *Provision

500 - 699 | Operator positions


10.2.3 2.1.2
501 Workstation 2 - TWR RJ45 LAN
LAN Switch 5 P1
ACAMS CAT6 Position 1

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 71
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
10.2.6 2.2.2
502 Workstation 4 - GND RJ45 LAN
LAN Switch 8 P1
ACAMS CAT6 Position 2
10.2.4 2.3.2
503 RJ45 LAN
LAN Switch 6 P1 Workstation 6 - CLR ACAMS CAT6 Position 3
10.2.5 2.4.2
504 RJ45 LAN
LAN Switch 7 P1 Workstation 8 - SUP ACAMS CAT6 Position 4
1.1.15 2.5.2
505 Workstation 10 - SO RJ45 LAN
LAN Switch 2 P10
ACAMS CAT6 Position 5
2.6.2
506 Workstation 12 - TWR Asst RJ45 LAN
--
ACAMS CAT6 Position 6 *Provision
1.1.14 2.7.2
507 Workstation 14 - TCMS RJ45 LAN
LAN Switch 1 P13
ACAMS CAT6 Position 7

2.1.4 2.1.2
511 Workstation 2 - TWR
Monitor - TWR ACAMS
ACAMS DP - DP Position 1
2.2.4 2.2.2
512 Workstation 4 - GND
Monitor - GND ACAMS
ACAMS DP - DP Position 2
2.3.4 2.3.2
513
Monitor - CLR ACAMS Workstation 6 - CLR ACAMS DP - DP Position 3
2.4.4 2.4.2
514
Monitor - SUP ACAMS Workstation 8 - SUP ACAMS DP - DP Position 4
2.5.4 2.5.2
515 Workstation 10 - SO
Monitor - SO ACAMS
ACAMS DP - DP Position 5
2.6.4 2.6.2
516 Workstation 12 - TWR Asst
Monitor - TWR Asst ACAMS
ACAMS DP - DP Position 6 *Provision
2.7.4 2.7.2
517 Workstation 14 - TCMS
Monitor - TCMS ACAMS
ACAMS DP - DP Position 7

2.1.4 2.1.2
521 Workstation 2 - TWR
Monitor - TWR ACAMS
ACAMS USB Position 1
2.2.4 2.2.2
522 Workstation 4 - GND
Monitor - GND ACAMS
ACAMS USB Position 2
2.3.4 2.3.2
523
Monitor - CLR ACAMS Workstation 6 - CLR ACAMS USB Position 3
2.4.4 2.4.2
524
Monitor - SUP ACAMS Workstation 8 - SUP ACAMS USB Position 4
2.5.4 2.5.2
525 Workstation 10 - SO
Monitor - SO ACAMS
ACAMS USB Position 5

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 72
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
2.6.4 2.6.2
526 Workstation12 - TWR Asst
Monitor - TWR Asst ACAMS
ACAMS USB Position 6 *Provision
2.7.4 2.7.2
527 Workstation 14 - TCMS
Monitor - TCMS ACAMS
ACAMS USB Position 7

2.1.7 2.1.2
531 Workstation 2 - TWR
KVM
ACAMS USB Position 1
2.2.7 2.2.2
532 Workstation 4 - GND
KVM
ACAMS USB Position 2
2.3.7 2.3.2
533
KVM Workstation 6 - CLR ACAMS USB Position 3
2.4.7 2.4.2
534
KVM Workstation 8 - SUP ACAMS USB Position 4
2.5.7 2.5.2
535 Workstation 10 - SO
KVM
ACAMS USB Position 5
2.6.7 2.6.2
536 Workstation 12 - TWR Asst
KVM
ACAMS USB Position 6 *Provision
2.7.7 2.7.2
537 Workstation 14 - TCMS
KVM
ACAMS USB Position 7 *Provision

2.1.8 2.1.2
541 Workstation 2 - TWR
Speaker
ACAMS USB Position 1
2.2.8 2.2.2
542 Workstation 4 - GND
Speaker
ACAMS USB Position 2
2.3.8 2.3.2
543
Speaker Workstation 6 - CLR ACAMS USB Position 3
2.4.8 2.4.2
544
Speaker Workstation 8 - SUP ACAMS USB Position 4
2.5.8 2.5.2
545 Workstation 10 - SO
Speaker
ACAMS USB Position 5
2.6.8 2.6.2
546 Workstation 12 - TWR Asst
Speaker
ACAMS USB Position 6 *Provision
2.7.8 2.7.2
547 Workstation 14 - TCMS
Speaker
ACAMS USB Position 7

2.1.9.1 2.1.2
551 Workstation 2 - TWR
XLR-USB Adapter
ACAMS USB Position 1

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 73
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
2.2.9.1 2.2.2
552 Workstation 4 - GND
XLR-USB Adapter
ACAMS USB Position 2
2.3.9.1 2.3.2
553
XLR-USB Adapter Workstation 6 - CLR ACAMS USB Position 3
2.4.9.1 2.4.2
554
XLR-USB Adapter Workstation 8 - SUP ACAMS USB Position 4
2.5.9.1 2.5.2
555
XLR-USB Adapter Workstation 10 - SO ACAMS USB Position 5 *Provision
2.6.9.1 2.6.2
556 Workstation 12 - TWR Asst
XLR-USB Adapter
ACAMS USB Position 6 *Provision
2.6.9.1 2.7.2
557 Workstation 14 - TCMS
XLR-USB Adapter
ACAMS USB Position 7 *Provision

2.1.9.1 2.1.9
561
XLR-USB Adapter Microphone - TWR XLR Position 1
2.2.9.1 2.2.9
562
XLR-USB Adapter Microphone - GND XLR Position 2
2.3.9.1 2.3.9
563
XLR-USB Adapter Microphone - CLR XLR Position 3
2.4.9.1 2.4.9
564
XLR-USB Adapter Microphone - SUP XLR Position 4
2.5.9.1 2.5.9
565
XLR-USB Adapter Microphone - SO XLR Position 5 *Provision
2.6.9.1 2.6.9
566
XLR-USB Adapter Microphone - TWR Asst XLR Position 6 *Provision
2.6.9.1 2.7.9
567
XLR-USB Adapter Microphone - TCMS XLR Position 7 *Provision

2.1.7 KVM
571
KVM Port selector --- Position 1
2.2.7 KVM
572
KVM Port selector --- Position 2
2.3.7 KVM
573
KVM Port selector --- Position 3
2.4.7 KVM
574
KVM Port selector --- Position 4
2.5.7 KVM
575
KVM Port selector --- Position 5
2.6.7 KVM
576
KVM Port selector --- Position 6 *Provision
2.7.7 KVM
577
KVM Port selector --- Position 7 *Provision

2.1.7 2.1.5
581
KVM Keyboard - TWR USB Position 1
2.2.7 2.2.5
582
KVM Keyboard - GND USB Position 2

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 74
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
2.3.7 2.3.5
583
KVM Keyboard - CLR USB Position 3
2.4.7 2.4.5
584
KVM Keyboard - SUP USB Position 4
2.5.7 2.5.5
585
KVM Keyboard - SO USB Position 5
2.6.1 2.6.5
586 Workstation 11 - TWR Asst
Keyboard - TWR Asst
TATIC USB Position 6
2.7.2 2.7.5
587
Workstation 14 - TCMS ACAMS Keyboard - TCMS USB Position 7

2.1.7 2.1.6
591
KVM Mouse - TWR USB Position 1
2.2.7 2.2.6
592
KVM Mouse - GND USB Position 2
2.3.7 2.3.6
593
KVM Mouse - CLR USB Position 3
2.4.7 2.4.6
594
KVM Mouse - SUP USB Position 4
2.5.7 2.5.6
595
KVM Mouse - SO USB Position 5
2.6.1 2.6.6
596 Workstation 11 - TWR Asst
Mouse - TWR Asst
TATIC USB Position 6
2.7.2 2.7.6
597
Workstation 14 - TCMS ACAMS Mouse - TCMS USB Position 7

10.2.3 2.1.1
601 RJ45 LAN
LAN Switch 5 P2 Workstation 1 - TWR TATIC CAT6 Position 1
10.2.6 2.2.1
602 RJ45 LAN
LAN Switch 8 P2 Workstation 3 - GND TATIC CAT6 Position 2
10.2.4 2.3.1
603 RJ45 LAN
LAN Switch 6 P2 Workstation 5 - CLR TATIC CAT6 Position 3
10.2.5 2.4.1
604 RJ45 LAN
LAN Switch 7 P2 Workstation 7 - SUP TATIC CAT6 Position 4
1.1.17 2.5.1
605 RJ45 LAN
LAN Switch 4 P10 Workstation 9 - SO TATIC CAT6 Position 5
10.2.3 2.6.1
606 Workstation 11 - TWR Asst RJ45 LAN
LAN Switch 5 P3
TATIC CAT6 Position 6
2.7.1
607 Workstation 13 - TCMS RJ45 LAN
--
TATIC CAT6 Position 7 *Provision

2.1.3 2.1.1
611
Monitor - TWR TATIC Workstation 1 - TWR TATIC DP - DP Position 1
2.2.3 2.2.1
612
Monitor - GND TATIC Workstation 3 - GND TATIC DP - DP Position 2
2.3.3 2.3.1
613
Monitor - CLR TATIC Workstation 5 - CLR TATIC DP - DP Position 3
Section: CABLE LIST Document ID: 20300-0304-B01
Date: 25.05.2022
© ACAMS AS Page: 75
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
2.4.3 2.4.1
614
Monitor - SUP TATIC Workstation 7 - SUP TATIC DP - DP Position 4
2.5.3 2.5.1
615
Monitor - SO TATIC Workstation 9 - SO TATIC DP - DP Position 5
2.6.3 2.6.1
616 Workstation 11 - TWR Asst
Monitor - TWR Asst TATIC
TATIC DP - DP Position 6
2.7.3 2.7.1
617 Workstation 13 - TCMS
Monitor - TCMS TATIC
TATIC DP - DP Position 7 *Provision

2.1.3 2.1.1
621
Monitor - TWR TATIC Workstation 1 - TWR TATIC USB Position 1
2.2.3 2.2.1
622
Monitor - GND TATIC Workstation 3 - GND TATIC USB Position 2
2.3.3 2.3.1
623
Monitor - CLR TATIC Workstation 5 - CLR TATIC USB Position 3
2.4.3 2.4.1
624
Monitor - SUP TATIC Workstation 7 - SUP TATIC USB Position 4
2.5.3 2.5.1
625
Monitor - SO TATIC Workstation 9 - SO TATIC USB Position 5
2.6.3 2.6.1
626 Workstation 11 - TWR Asst
Monitor - TWR Asst TATIC
TATIC USB Position 6
2.7.3 2.7.1
627 Workstation 13 - TCMS
Monitor - TCMS TATIC
TATIC USB Position 7 *Provision

2.1.7 2.1.1
631
KVM Workstation 1 - TWR TATIC USB Position 1
2.2.7 2.2.1
632
KVM Workstation 3 - GND TATIC USB Position 2
2.3.7 2.3.1
633
KVM Workstation 5 - CLR TATIC USB Position 3
2.4.7 2.4.1
634
KVM Workstation 7 - SUP TATIC USB Position 4
2.5.7 2.5.1
635
KVM Workstation 9 - SO TATIC USB Position 5
2.6.7 2.6.1
636 Workstation 11 - TWR Asst
KVM
TATIC USB Position 6 *Provision
2.7.7 2.7.1
637 Workstation 13 - TCMS
KVM
TATIC USB Position 7 *Provision

700 - 799 | Substations & ALCMS

*Provision

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 76
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
800 - 899 | Miscellaneous internal
1.1.10 1.1.1
801
KVM Tray P1 ACAMS Server 1 KVM --
1.1.10 1.1.2
802
KVM Tray P2 ACAMS Server 2 KVM --
1.1.10 1.1.3
803
KVM Tray P2 ACAMS Server 3 KVM --
1.1.10 1.1.4
804
KVM Tray P3 ACAMS Server 4 KVM --
1.1.10 1.1.5
805
KVM Tray P4 TATIC Server 1 KVM --
1.1.10 1.1.6
806
KVM Tray P5 TATIC Server 2 KVM --
1.1.10 1.1.7
807
KVM Tray P7 TATIC Server 3 KVM --
1.1.10 1.1.8
808
KVM Tray P8 TATIC Server 4 KVM --

1.1.25 1.1
RJ45 LAN ATIS
810
ASU Radio TX ACAMS Rack TB1 1-2 CAT6 audio + PTT output
1.1.25 1.1.11 Mini
811
ASU AUDIO 1 Sound Bar P1 Jack --
1.1.25 1.1.11 Mini
812
ASU AUDIO 2 Sound Bar P2 Jack --
1.1.3 1.1.11
813
ACAMS Server 3 Sound Bar P3 Audio --
1.1.4 1.1.11
814
ACAMS Server 4 Sound Bar P4 Audio --

1.1.9.1 1.1.5
821
SAN Controller 1 - SAS 1 TATIC Server 1 SAS --
1.1.9.2 1.1.5
822
SAN Controller 2 - SAS 1 TATIC Server 1 SAS --
1.1.9.1 1.1.6
823
SAN Controller 1 - SAS 2 TATIC Server 2 SAS --
1.1.9.2 1.1.6
824
SAN Controller 2 - SAS 2 TATIC Server 2 SAS --
1.1.9.1 1.1.7
825
SAN Controller 1 - SAS 3 TATIC Server 3 SAS --
1.1.9.2 1.1.7
826
SAN Controller 2 - SAS 3 TATIC Server 3 SAS --
1.1.9.1 1.1.8
827
SAN Controller 1 - SAS 4 TATIC Server 4 SAS --
1.1.9.2 1.1.8
828
SAN Controller 2 - SAS 4 TATIC Server 4 SAS --

900 - 999 | Others


13.1.1 10.1.1 Backup VHF
900
Transceiver TWR QDC12 - TB50 - 21 Audio Recording

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 77
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
13.1.1 13.1.2
901
Transceiver TWR Controller TWR Audio Backup VHF
13.1.1 13.1.2 Backup VHF
902
Transceiver TWR Controller TWR Audio *Provision
13.2.1 10.1.1 Backup VHF
903
Transceiver GND QDC12 - TB50 - 22 Audio Recording
13.2.1 13.2.2
904
Transceiver GND Controller GND Audio Backup VHF
13.2.1 13.2.2 Backup VHF
905
Transceiver GND Controller GND Audio *Provision

GRU 10.1.1
910
Airport Radio QDC12 - TB50 - 23 Audio Radio Recording

1000 - 1099 | Central Equipment Power


1.1.20 1.1 UPS
1001
ACAMS Rack - PDU1 ACAMS Rack - X220A 220V AC --
1.1.21 1.1 UPS
1002
ACAMS Rack - PDU2 ACAMS Rack - X220B 220V AC --
1.1.22 1.1 UPS
1003
ACAMS Rack - PDU3 ACAMS Rack - X220C 220V AC --
1.1.23 1.1 UPS
1004
ACAMS Rack - PDU4 ACAMS Rack - X220D 220V AC --
1.1 Technical Room UPS 220V UPS
1005
ACAMS Rack - X220A QDF 220V AC --
1.1 Technical Room UPS 220V UPS
1006
ACAMS Rack - X220B QDF 220V AC --
1.1 Technical Room UPS 220V UPS
1007
ACAMS Rack - X220C QDF 220V AC --
1.1 Technical Room UPS 220V UPS
1008
ACAMS Rack - X220D QDF 220V AC --
1009
-- -- -- *Provision
1010
-- -- -- *Provision
1.1.20 1.1.1 UPS
1011
ACAMS Rack - PDU1 P1 ACAMS Server 1 - PSU1 220V AC --
1.1.20 1.1.3 UPS
1012
ACAMS Rack - PDU1 P2 ACAMS Server 3 - PSU1 220V AC --
1.1.20 1.1.5 UPS
1013
ACAMS Rack - PDU1 P3 TATIC Server 1 - PSU1 220V AC --
1.1.20 1.1.7 UPS
1014
ACAMS Rack - PDU1 P4 TATIC Server 3 - PSU1 220V AC --
1.1.20 1.1.9 UPS
1015
ACAMS Rack - PDU1 P5 SAN - PSU1 220V AC --
1.1.20 1.1.25 UPS
1016
ACAMS Rack - PDU1 P6 ATIS Switchover Unit - PSU1 220V AC --
1.1.20 1.1.14 UPS
1017
ACAMS Rack - PDU1 P7 LAN Switch 1 220V AC --

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 78
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1.1.20 1.1.18.1 UPS
1018
ACAMS Rack - PDU1 P8 12V DC PSU Firewall 1 220VAC --
1018 1.1.20 1.1.18
A 12V DC PSU Firewall 1 Firewall 1 DC 12V --
1.1.20 1.1.12 UPS
1019
ACAMS Rack - PDU1 P9 Serial device Nport1 220V AC --
1.1.20 1.1.24 UPS
1020
ACAMS Rack - PDU1 P10 Bell Modems - PSU 1 220V AC *Provision
1.1.20 1.1.28
1021 NAVAIDS OFC Assembly - UPS
ACAMS Rack - PDU1 P11
PSU 1 220V AC *Provision

1.1.21 1.1.2 UPS


1031
ACAMS Rack - PDU2 P1 ACAMS Server 2 - PSU1 220V AC --
1.1.21 1.1.4 UPS
1032
ACAMS Rack - PDU2 P2 ACAMS Server 4 - PSU1 220V AC --
1.1.21 1.1.6 UPS
1033
ACAMS Rack - PDU2 P3 TATIC Server 2 - PSU1 220V AC --
1.1.21 1.1.8 UPS220V
1034
ACAMS Rack - PDU2 P4 TATIC Server 4 - PSU1 AC --
1.1.21 1.1.16 UPS
1035
ACAMS Rack - PDU2 P5 LAN Switch 3 220V AC --
1.1.21 1.1.26 UPS
1036
ACAMS Rack - PDU2 P6 Crash alarm Assembly 220V AC --
1.1.21 1.1.26.5 UPS
1037
ACAMS Rack - PDU2 P7 Crash alarm PSU2 48V 220V AC *Provision

1.1.22 1.1.1 UPS


1051
ACAMS Rack - PDU3 P1 ACAMS Server 1 - PSU2 220V AC --
1.1.22 1.1.3 UPS
1052
ACAMS Rack - PDU3 P2 ACAMS Server 3 - PSU2 220V AC --
1.1.22 1.1.5 UPS
1053
ACAMS Rack - PDU3 P3 TATIC Server 1 - PSU2 220V AC --
1.1.22 1.1.7 UPS
1054
ACAMS Rack - PDU3 P4 TATIC Server 3 - PSU2 220V AC --
1.1.22 1.1.9 UPS
1055
ACAMS Rack - PDU3 P5 SAN - PSU2 220V AC --
1.1.22 1.1.25 UPS
1056
ACAMS Rack - PDU3 P6 ATIS Switch Over - PSU2 220V AC --
1.1.22 1.1.15 UPS
1057
ACAMS Rack - PDU3 P7 LAN Switch 2 220V AC --
1.1.22 1.1.19.1 UPS
1058
ACAMS Rack - PDU3 P8 12V DC PSU Firewall 2 220V AC --
1058 1.1.19.1 1.1.19
A 12V DC PSU Firewall 2 Firewall 2 DC 12V --
1.1.22 1.1.13 UPS
1059
ACAMS Rack - PDU3 P9 Serial device Nport2 220V AC --
1.1.22 1.1.24 UPS
1060
ACAMS Rack - PDU3 P10 Bell Modems - PSU2 220V AC *Provision

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 79
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1.1.22 1.1.28
1061 NAVAIDS OFC Assembly - UPS
ACAMS Rack - PDU3 P11
PSU 2 220V AC *Provision
1.1.23 1.1.2 UPS
1071
ACAMS Rack - PDU4 P1 ACAMS Server 2 - PSU2 220V AC --
1.1.23 1.1.4 UPS
1072
ACAMS Rack - PDU4 P2 ACAMS Server 4 - PSU2 220V AC --
1.1.23 1.1.6 UPS
1073
ACAMS Rack - PDU4 P3 TATIC Server 2 - PSU2 220V AC --
1.1.23 1.1.8 UPS
1074
ACAMS Rack - PDU4 P4 TATIC Server 4 - PSU2 220V AC --
1.1.23 1.1.17 UPS
1075
ACAMS Rack - PDU4 P5 LAN Switch 4 220V AC --
1.1.23 1.1.10 UPS
1076
ACAMS Rack - PDU4 P6 KVM tray 220V AC --
1.1.23 1.1.11 UPS
1077
ACAMS Rack - PDU4 P7 Sound bar 220V AC --

1100 - 1399 | Operator Position & Tower Systems Power


Tower UPS 220V Tower Console UPS
1101
QDFE PDU - Socket strip - TWR 220V AC --
Tower UPS 220V Tower Console
1102 PDU - Socket strip - TWR UPS
QDFE
Asst 220V AC --
Tower UPS 220V Tower Console UPS
1103
QDFE PDU - Socket strip - GND 220V AC --
Tower UPS 220V Tower Console UPS
1104
QDFE PDU - Socket strip - CLR 220V AC --
Tower UPS 220V Tower Console UPS220V
1105
QDFE PDU - Socket strip - SUP AC --
Tower UPS 220V Tower Console UPS
1106
QDFE PDU - Socket strip - Table 220V AC --

1111 Tower Console 2.1.2.1 UPS


A PDU - Socket strip PSU – Workstation 2 220V AC Position 1
DC Adapter 2.1.2
1111
Workstation 2 - TWR
B PSU – Workstation 2
ACAMS 19V DC Position 1
1112 Tower Console 2.2.2.1 UPS
A PDU - Socket strip PSU – Workstation 4 220V AC Position 2
2.2.2.1 2.2.2
1112
Workstation 4 - GND
B PSU – Workstation 4
ACAMS 19V DC Position 2
Tower Console 2.3.2.1 UPS220V
1113A
PDU - Socket strip PSU – Workstation 6 AC Position 3
1113 2.3.2.1 2.3.2
B PSU – Workstation 6 Workstation 6 - CLR ACAMS 19V DC Position 3
1114 Tower Console 2.4.2.1 UPS
A PDU - Socket strip PSU – Workstation 8 220V AC Position 4

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 80
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
1114 2.4.2.1 2.4.2
B PSU – Workstation 8 Workstation - SUP ACAMS 19V DC Position 4
1115 SO Position 2.5.2.1 UPS
A PDU - Socket strip PSU – Workstation 10 220V AC Position 5
2.5.2.1 2.5.2
1115
Workstation 10 - SO
B PSU – Workstation 10
ACAMS 19V DC Position 5
1116 Tower Console 2.6.2.1 UPS
A PDU - Socket strip PSU – Workstation 12 220V AC Position 6 *Provision
2.6.2.1 2.6.2
1116
Workstation 12 - TWR Asst
B PSU – Workstation 12
ACAMS 19V DC Position 6 *Provision
1117 Technical Room 2.7.2.1 UPS
A PDU - Socket strip PSU – Workstation 14 220V AC Position 7
2.7.2.1 2.7.2
1117
Workstation 14 - TCMS
B PSU – Workstation 14
ACAMS 19V DC Position 7

1121 Tower Console 2.1.1.1 UPS


A PDU - Socket strip PSU – Workstation 1 220V AC Position 1
1121 2.1.1.1 2.1.1
B PSU – Workstation 1 Workstation 1 - TWR TATIC 19V DC Position 1
1122 Tower Console 2.2.1.1 UPS
A PDU - Socket strip PSU – Workstation 3 220V AC Position 2
1122 2.2.1.1 2.2.1
B PSU – Workstation 3 Workstation 3 - GND TATIC 19V DC Position 2
1123 Tower Console 2.3.1.1 UPS
A PDU - Socket strip PSU – Workstation 5 220V AC Position 3
1123 2.3.1.1 2.3.1
B PSU – Workstation 5 Workstation 5 - CLR TATIC 19V DC Position 3
1124 Tower Console 2.4.1.1 UPS
A PDU - Socket strip PSU – Workstation 7 220V AC Position 4
1124 2.4.1.1 2.4.1
B PSU – Workstation 7 Workstation 7 - SUP TATIC 19V DC Position 4
1125 SO Position 2.5.1.1 UPS
A PDU - Socket strip PSU – Workstation 9 220V AC Position 5
1125 DC Adapter 2.5.1
B PSU – Workstation 9 Workstation 9 - SO TATIC 19V DC Position 5
1126 Tower Console 2.6.1.1 UPS
A PDU - Socket strip PSU – Workstation 11 220V AC Position 6
2.6.1.1 2.6.1
1126
Workstation 11 - TWR Asst
B PSU – Workstation 11
TATIC 19V DC Position 6
1127 Technical Room 2.7.1.1 UPS
A PDU - Socket strip PSU – Workstation 13 220V AC Position 7 *Provision
2.7.1.1 2.7.1
1127
Workstation 13 - TCMS
B PSU – Workstation 13
TATIC 19V DC Position 7 *Provision

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 81
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
Tower Console 2.1.4 UPS
1131
PDU - Socket strip Monitor - TWR ACAMS 220V AC Position 1
Tower Console 2.2.4 UPS
1132
PDU - Socket strip Monitor - GND ACAMS 220V AC Position 2
Tower Console 2.3.4 UPS
1133
PDU - Socket strip Monitor - CLR ACAMS 220V AC Position 3
Tower Console 2.4.4 UPS
1134
PDU - Socket strip Monitor - SUP ACAMS 220V AC Position 4
SO Position 2.5.4 UPS
1135
PDU - Socket strip Monitor - SO ACAMS 220V AC Position 5
Tower Console 2.6.4 UPS
1136
PDU - Socket strip Monitor - TWR Asst ACAMS 220V AC Position 6 *Provision
Technical Room 2.7.4 UPS
1137
PDU - Socket strip Monitor - TCMS ACAMS 220V AC Position 7

Tower Console 2.1.3 UPS


1141
PDU - Socket strip Monitor - TWR TATIC 220V AC Position 1
Tower Console 2.2.3 UPS
1142
PDU - Socket strip Monitor - GND TATIC 220V AC Position 2
Tower Console 2.3.3 UPS
1143
PDU - Socket strip Monitor - CLR TATIC 220V AC Position 3
Tower Console 2.4.3 UPS
1144
PDU - Socket strip Monitor - SUP TATIC 220V AC Position 4
SO Position 2.5.3 UPS220V
1145
PDU - Socket strip Monitor - SO TATIC AC Position 5
Tower Console 2.6.3 UPS
1146
PDU - Socket strip Monitor - TWR Asst TATIC 220V AC Position 6
Technical Room 2.7.3 UPS
1147
PDU - Socket strip Monitor - TCMS TATIC 220V AC Position 7 *Provision

Tower UPS 220V 5.1 UPS


1150
QDFE 2 - DJ 13 QDC10 - Spotlights 220V AC Spotlights
Tower UPS 220V 6.1 UPS
1151
QDFE 2 - DJ 14 QDC11 - Sunshades 220V AC Sunshades
UPS
1152
-- -- 220V AC *Provision
Tower UPS 220V 7.1 UPS
1153
QDFE 2 - DJ 03 QDC13 - Access Control 220V AC Access Control
UPS
1154
-- -- 220V AC *Provision
1155 Tower UPS 220V 10.2 UPS Tower LAN Interface
A QDFE 2 - DJ 01 QDC15 - X220A 220V AC Power Supply 1
1155 Tower UPS 220V 10.2 UPS Tower LAN Interface
B QDFE 2 - DJ 02 QDC15 - X220B 220V AC Power Supply 2

5.1 5.2
1168
QDC10 Spotlight Rails Gnd Spotlights *Provision
5.1 5.2
1169
QDC10 Spotlight Rails Neutral Spotlights *Provision

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 82
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
5.1 1170A
1170 Controlled
QDC10 - X100 Spotlight Rails Power Spotlights
1170 1170 to 1172 5.2.1
Controlled
A from QDC10 - X100 Spotlights - Table Power L1 Spotlights
5.1 5.2
1171 Controlled
QDC10 - X100 Spotlight Rails Power Spotlightse
1171 1170 to 1172 5.2.2
Controlled
A from QDC10 - X100 Spotlights - TWR Power L2 Spotlights
5.1 5.2
1172 Controlled
QDC10 - X100 Spotlight Rails Power Spotlights
1172 1170 to 1172 5.2.3
Controlled
A from QDC10 - X100 Spotlights - TWR Asst Power L3 Spotlights
5.1 5.2
1173 Controlled
QDC10 - X100 Spotlight Rails Power Spotlights
1173 1170 to 1172 5.2.4
Controlled
A from QDC10 - X100 Spotlights - GND Power L1 Spotlights
5.1 5.2
1174 Controlled
QDC10 - X100 Spotlight Rails Power Spotlights
1174 1170 to 1172 5.2.5
Controlled
A from QDC10 - X100 Spotlights - CLR Power L2 Spotlights
5.1 5.2
1175 Controlled
QDC10 - X100 Spotlight Rails Power Spotlights
1175 1170 to 1172 5.2.6
Controlled
A from QDC10 - X100 Spotlights - Room Power L3 Spotlights
5.1 5.2.7
1176 Controlled
QDC10 - X100 Spotlights - SUP Power L1 Spotlights
5.1 5.2.8
1177 Controlled
QDC10 - X100 Spotlights - Stairs Power L1 Spotlights

6.1 6.2 Sunshades


1180
QDC11 Sunshades Motors Gnd *Provision
6.1 6.2
1181
QDC11 Sunshades Neutral Sunshades*Provision

6.1 6.2.1.1
1191 Controlled
QDC11 - X100 Sunshade 1 - Motor 1 Power Sunshades
6.1 6.2.2.1
1192 Controlled
QDC11 - X100 Sunshade 2 - Motor 2 Power Sunshades
6.1 6.2.3.1
1193 Controlled
QDC11 - X100 Sunshade 3 - Motor 3 Power Sunshades
6.1 6.2.4.1
1194 Controlled
QDC11 - X100 Sunshade 4 - Motor 4 Power Sunshades
6.1 6.2.5.1
1195 Controlled
QDC11 - X100 Sunshade 5 - Motor 5 Power Sunshades
6.1 6.2.6.1
1196 Controlled
QDC11 - X100 Sunshade 6 - Motor 6 Power Sunshades
6.1 6.2.7.1
1197 Controlled
QDC11 - X100 Sunshade 7 - Motor 7 Power Sunshades
6.1 6.2.8.1
1198 Controlled
QDC11 - X100 Sunshade 8 - Motor 8 Power Sunshades

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 83
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
6.1 Sunshades
1199
QDC11 -- -- *Provision
6.1 Sunshades
1200
QDC11 -- -- *Provision
6.1 Sunshades
1201
QDC11 -- -- *Provision
6.1 Sunshades
1202
QDC11 -- -- *Provision

4.1 UPS QDC4 Beacon


1205
QDC4 Beacon 220V AC *Provision

Tower Commercial 220V 5.4.1 Com.


1220
QDL Dimmer Panel 220V AC Common lights
Com. Common lights
1221
-- -- 220V AC *Provision
5.4.1 1222A and 1222B Com.
1222
Dimmer Panel - Dimmer 1 Ceiling lights - D1 and D2 220V AC Common lights
1222 1222 Com.
A from Dimmer 1 Ceiling light - D1 220V AC Common lights
1222 1222 Com.
B from Dimmer 2 Ceiling light - D2 220V AC Common lights
5.4.1 1223A and 1223B Com.
1223
Dimmer Panel - Dimmer 2 Ceiling lights - D3 and D4 220V AC Common lights
1223 1223 Com.
A from Dimmer 3 Ceiling light - D3 220V AC Common lights
1223 1223 Com.
B from Dimmer 4 Ceiling light - D4 220V AC Common lights
5.4.1 1224A and 1224B Com.
1224
Dimmer Panel - Dimmer 3 Ceiling lights - D4 and D5 220V AC Common lights
1224 1224 Com.
A from Dimmer 5 Ceiling light - D5 220V AC Common lights
1224 1224 Com.
B from Dimmer 6 Ceiling light - D6 220V AC Common lights
5.4.1 1225A and 1225B Com.
1225
Dimmer Panel - Dimmer 4 Ceiling lights - D5 and D6 220V AC Common lights
1225 1225 Com.
A from Dimmer 7 Ceiling light - D7 220V AC Common lights
1225 1225 Com.
B from Dimmer 8 Ceiling light - D8 220V AC Common lights

Backup VHF 13.1.4 Com.


1240
Main socket - TWR Mini UPS - TWR 220V AC Backup VHF
13.1.4 13.1.1 Com.
1241
Mini UPS - TWR Transceiver TWR 220V AC Backup VHF
13.1.4 13.1.2 Com.
1242
Mini UPS - TWR Controller TWR 220V AC Backup VHF
Backup VHF 13.2.4 Com.
1243
Main socket - GND Mini UPS - GND 220V AC Backup VHF

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 84
Document: Standard Tower Installation Manual
Project Guarulhos International Airport
Client: CISCEA

Cable
From To Type Remarks
ID
13.2.4 13.2.1 Com.
1244
Mini UPS - GND Transceiver GND 220V AC Backup VHF
13.2.4 13.2.2 Com.
1245
Mini UPS - GND Controller GND 220V AC Backup VHF

Tower Console 9.1 UPS


1248
PDU - Socket strip Printer 220V AC Printer
Tower Console 12.1.2 UPS
1249
PDU - Socket strip Light Gun Charger 220V AC Signal Light Gun
Tower Commercial 220V Backup VHF Com.
1250
QDL Main socket - TWR 220V AC Backup VHF
Tower Commercial 220V Backup VHF Com.
1251
QDL Main socket - GND 220V AC Backup VHF
Tower Commercial 220V Tower
1252 220V
QDL Com. PDU - Socket strip 1 Comercial General Purpose PDU
Tower Commercial 220V Tower
1253 220V
QDL Com. PDU - Socket strip 2 Comercial General Purpose PDU
Tower Commercial 220V Tower
1253 220V
QDL Com. PDU - Socket strip 3 Comercial General Purpose PDU

Tower Console 8.1.3 UPS


1260
PDU - Socket strip Barometer PSU 220V AC Aviation Barometer
1260 8.1.3 8.1.1
A Barometer PSU AviMet Display 24V DC Aviation Barometer

Tower Console 15.1.2 UPS


1270
PDU - Socket strip PoE Injector 220V AC Tower PTZ Camera *Provision
Tower Console 15.1.3 UPS
1271
PDU - Socket strip PTZ Controller 220V AC Tower PTZ Camera *Provision

1400 - 1499 | Substation & External Power


Substation UPS 220V 3.1 UPS
1401
DJ ACAMS QDC1 220V AC ALCMS *Provision

***

Section: CABLE LIST Document ID: 20300-0304-B01


Date: 25.05.2022
© ACAMS AS Page: 85