Professional Documents
Culture Documents
ICB12 ICB18 ICB30 3-Wire IOL DS
ICB12 ICB18 ICB30 3-Wire IOL DS
ICB12 ICB18 ICB30 3-Wire IOL DS
Benefits
• A complete family. Available in M12, M18 and M30
robust nickel-plated brass housings with an operating
distance of 4 to 22 mm.
• Less machine downtime. Lower risk of mechanical
damage thanks to the extended operating distance.
• Easy to install. ICB sensors have a milled section for
wrench grip and two different thread lengths. The user
can choose between 2 m PVC cable and M12-disconnect
plug versions.
• High precision. The onboard advanced microcontroller
ensures better stability with respect to environmental
influences, with highly reliable repeatable measurements
between -25 and +70°C.
• Easy customization to specific OEM requests:
different cable lengths and materials, special labelling,
customized pig-tail solutions with special cables and
connectors are possible on request.
• The output can be operated either as a switching output
or in IO-Link mode.
Description • Fully configurable via IO-Link v1.1. Electrical outputs
can be configured as PNP/NPN/Push-pull, normally
open or normally closed.
The new generation ICB series is a complete • Timer functions can be set, such as switch-on and
family of high performance inductive sensors for switch-off delay
contactless and wear free detection of metallic • Adjustable sensing distance and hysteresis: sensing
objects in industrial automation applications, such distance can be set to 33%, 50%, 75% or 100% of the
as packaging, materials handling and machine maximum sensing distance
• Temperature monitoring: over or under-run temperature
tools. The advanced electronics is enclosed in a
alarms can be set
robust nickel-plated brass housing. It is available
in three diameters: M12, M18 and M30 with an
extended sensing distance range between 4 and •
22 mm.
On-board IO-Link communication opens up many
possibilities, such as easy configuration and set-
up of the devices and advanced parameter setting.
Applications
• Non contact detection of metal objects in general position-sensing and presence-sensing in industrial applications
• Particularly suitable for rotational speed monitoring thanks to the high operating frequency
Main functions
• Integrated diagnostic function with flashing LED in the event of a short circuit or overload
• The devices can be operated in IO-Link mode once connected to an IO-Link master, or in standard I/O mode.
• In IO-Link mode the switching signals of the sensor are made available in the process data via the IO-Link interface.
• Several sensor functions can be set via the IO-Link interface:
► Adjustable switching distance: 33%, 50%, 75% or 100% of the maximum switching distance.
► Adjustable hysteresis: standard or increased value.
► Divider function: the sensor gives a signal after a specified number of actuation pulses has been
reached.
► Switch-on delay: the switching pulse is generated after the sensor actuation.
► Switch-off delay: the generation of the switch signal is delayed by the set time after sensor actuation.
► Temperature error: temperature is out of specifications.
► Temperature over-run and under-run: temperature is out of the limits defined by the user.
References
Order code
ICB IO
Selection guide
ICB12
Detec-
Con-
Body tion Rated operating dis-
nec- Output type Ordering no.
style princi- tance Sn
tion
ple
Cable ICB12S30F04A2IO
Flush
Plug ICB12S30F04M1IO
Short
Cable Non- Configurable: 33%, 50%, ICB12S30N08A2IO
flush Configurable: NPN/PNP/push-pull
Plug 75% or 100% of the ICB12S30N08M1IO
NO/NC
Cable maximum Sn ICB12L50F04A2IO
Flush Factory setting: PNP, NO
Plug Factory setting: 100% ICB12L50F04M1IO
Long
Cable Non- ICB12L50N08A2IO
Plug flush ICB12L50N08M1IO
ICB18
Detec-
Con-
Body tion Rated operating dis-
nec- Output type Ordering no.
style princi- tance Sn
tion
ple
Cable ICB18S30F08A2IO
Flush
Plug ICB18S30F08M1IO
Short
Cable Non- Configurable: 33%, 50%, ICB18S30N14A2IO
flush Configurable: NPN/PNP/push-pull
Plug 75% or 100% of the ICB18S30N14M1IO
NO/NC
Cable maximum Sn ICB18L50F08A2IO
Flush Factory setting: PNP, NO
Plug Factory setting: 100% ICB18L50F08M1IO
Long
Cable Non- ICB18L50N14A2IO
Plug flush ICB18L50N14M1IO
ICB30
Detec-
Con-
Body tion Rated operating dis-
nec- Output type Ordering no.
style princi- tance Sn
tion
ple
Cable ICB30S30F15A2IO
Flush
Plug ICB30S30F15M1IO
Short
Cable Non- Configurable: 33%, 50%, ICB30S30N22A2IO
flush Configurable: NPN/PNP/push-pull
Plug 75% or 100% of the ICB30S30N22M1IO
NO/NC
Cable maximum Sn ICB30L50F15A2IO
Flush Factory setting: PNP, NO
Plug Factory setting: 100% ICB30L50F15M1IO
Long
Cable Non- ICB30L50N22A2IO
Plug flush ICB30L50N22M1IO
Structure
ICB12
A B C D E A B C D A
C
D
ICB18
A B C D E A B C D A
ICB30
A B C D A B C A
B
C
Sensing
Detection
Rated operating distance Sn 4 to 22 mm: depending on housing diameter and version (flush or non-flush)
The operating distance is measured according to IEC 60947-5-2, using a
standard target moving axially.
This target is square shape 1 mm thickness, made of steel e.g. type Fe 360
as defined in ISO 630 and it shall be of the rolled finish.
Reference target
The length of the side of the square is equal to
– the diameter of the circle inscribed on the active surface of the sensing face,
or
– three times the rated operating distance Sn whichever is greater
Assured operating sensing distance
0 ≤ Sa ≤ 0.81 x Sn (e.g. with Sn of 4 mm, Sa is 0 ... 3.24 mm)
(Sa)
Effective operating distance (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x Sn
Usable operating distance (Su) 0.9 x Sr ≤ Su ≤ 1.1 x Sr
Hysteresis (H) 1...20%
S
Y S: sensor
X
T T: target
2 T 0,1 4 T 0,18
[Inches]
[Inches]
[mm]
[mm]
0 S 0 0 S 0
-2
-0,11 -4 -0,18
-4
-0,21 -8
-6 -0,37
-8 -0,32 -12
-0,5 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 -0,55
0 1 2 3 4 5 6 7 8
Distance [mm] Distance [mm]
Fig. 1 M12 Flush Fig. 2 M12 Non-flush
Distance [Inches]
Distance [Inches] -0,2 -0,1 0 0,1 0,2 0,3 0,4 0,5 0,6
-0,02 0,02 0,06 0,1 0,14 0,18 0,22 0,26 0,3 24
0,55
12 0,76
16
0,37
8
0,38
T 0,18 8 T
4
[Inches]
[Inches]
[mm]
[mm]
0 S 0 0 S 0
-4 -0,18 -8
-0,38
-8
-0,37
-16
-12 -0,76
-0,55
0 1 2 3 4 5 6 7 8 -24
Distance [mm] -4 -2 0 2 4 6 8 10 12 14
Distance [mm]
Fig. 3 M18 Flush Fig. 4 M18 Non-flush
Distance [Inches] Distance [Inches]
-0,04 0,04 0,12 0,2 0,28 0,36 0,44 0,52 0,6 -0,24 -0,09 0,06 0,21 0,36 0,51 0,66 0,81
24 1,4
0,76 30
16 1,05
20
0,7
0,38
8 T 10 T 0,35
[Inches]
[Inches]
[mm]
[mm]
0 S 0 0 S 0
-10 -0,35
-8 -0,38
-0,7
-20
-16
-0,76 -1,05
-30
-24 -1,4
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22
Distance [mm] Distance [mm]
Correction factors
The specific operating distance Sn refers to defined measuring conditions. The following data have to be
considered as general guidelines.
Fe360 : Steel
CrNi : Chrome-nickel
CuZn : Brass
Al : Aluminium
Cu : Copper
Sr : Effective operating distance
Accuracy
Features
Power Supply
Outputs
Response times
≤ 2 kHz ICB12
Operating frequency (f) ≤ 1.5 kHz ICB18
≤ 1 kHz ICB30
Indication
Standard IO mode:
IO-Link mode:
Green LED:
• LED is ON for 0.75 s and OFF for 0.075 s
• Possibility to disable the LED
Environmental
Ambient temperature for cable ver- Operating: -25° to +70°C (-13° to +158°F)
sions Storage: -30° to +80°C (-22° to +176°F)
Ambient temperature for plug ver- Operating: -40° to +70°C (-40° to +158°F)
sions Storage: -40° to +80°C (-40° to +176°F)
Operating: 35% to 95%
Ambient humidity
Storage: 35% to 95%
10 to 55 Hz, amplitude 1.0 mm; sweep cycle 5
Vibration IEC 60068-2-6
min; in X, Y and Z direction
Shock 30 G /11 ms. 10 shocks in X, Y and Z direction IEC 60068-2-27
Rough handling shocks 2 times from 1m, 100 times from 0.5m IEC 60068-2-31
Degree of protection IP67 IEC 60529; EN 60947-1
Rated impulse withstand voltage ≥ 1 kV with 500 Ω
Approvals (UL508)
CCC is not required for products rated ≤ 36 V
Mechanical data
Cable version: short, flush: 76.2g; short, non-flush: 76.8g; long, flush:
82.2g; long, non-flush: 82.8g;
M12
Plug version: short, flush: 29.5g; short, non-flush: 30.1g; long, flush:
35.2g; long, non-flush: 35.8g.
Cable version: short, flush: 100.3g; short, non-flush: 102.8g; long, flush:
Weight (including 2 nuts and the 112.6g; long, non-flush: 115.1g;
M18
packaging) max. Plug version: short, flush: 57.4g; short, non-flush: 59.9g; long, flush:
69.8g; long, non-flush: 72.3g.
Cable version: short, flush: 191.1g; short, non-flush: 197.6g; long, flush:
219.4g; long, non-flush: 226g;
M30
Plug version: short, flush: 127g; short, non-flush: 133.5g; long, flush:
159.6g; long, non-flush: 166.1g.
Mounting Flush mountable or non-flush mountable
Housing: Nickel-plated brass
Material
Front cap: Grey thermoplastic polyester
ICB12: 10 Nm
Max tightening torque ICB18: 25 Nm
ICB30: 30 Nm
Electrical connection
ICB12 and ICB18: 2m, 3 x 0.25 mm2, Ø4.1 mm, PVC, grey, oil proof
Cable
ICB30: 2m, 3 x 0.34 mm2, Ø5.2 mm, PVC, grey, oil proof
Plug M12 x 1, 4 pin, male connector
Communication
Connection Diagrams
1 BN + 1 BN +
4 BK
4 BK
3 BU 3 BU
- -
Fig. 8 NPN - Normally open Fig. 9 NPN - Normally closed
1 BN + 1 BN +
4 BK
4 BK
3 BU 3 BU
- -
Fig. 10 PNP - Normally open Fig. 11 PNP - Normally closed
1 BN +
4 BK Out/IO-Link
3 BU
-
Fig. 12 IO-Link
Colour code
BN: brown BK: black BU: blue
Dimensions [mm]
ICB12 [mm]
4 SW17 4 SW17
LED LED
M12x1
M12x1
7.5
Ø4.1
Ø4.1
7.5
2x lock washer 2x lock washer
30 4 30
32 36
Fig. 13 Short body, flush version, cable Fig. 14 Short body, non-flush version, cable
4 3 4 3
1 2 1 2
33.2 33.2
4 SW17 Ø3 LEDx4 Ø3 LEDx4
4 SW17
8.2 8.2
M12x1
M12x1
M12x1
M12x1
7.5 7.5
11.1 11.1
2x lock washer 2x lock washer
30 4 30
50.2 54.2
Fig. 15 Short body, flush version, plug Fig. 16 Short body, non-flush version, plug
4 SW17 4 SW17
LED LED
M12x1
M12x1
7.5 7.5
Ø4.1
Ø4.1
4 3 4 3
1 2 1 2
M12x1
M12x1
M12x1
7.5 7.5
11.1 11.1
2x lock washer 2x lock washer
50 4 50
70.2 74.2
Fig. 19 Long body, flush version, plug Fig. 20 Long body, non-flush version, plug
ICB18 [mm]
4 SW24 4 SW24
LED LED
M18x1
M18x1
Ø4.1
Ø4.1
7.5 7.5
2x lock washer 2x lock washer
30 10 30
32 42
Fig. 21 Short body, flush version, cable Fig. 22 Short body, non-flush version, cable
4 3 4 3
1 2 1 2
36.5 36.5
4 SW24 4 SW24
Ø3 LEDx4 Ø3 LEDx4
8 8
M18x1
M18x1
M12x1
M12x1
7.5 11 7.5 11
2x lock washer 2x lock washer
30 10 30
54 64
Fig. 23 Short body, flush version, plug Fig. 24 Short body, non-flush version, plug
4 SW24 4 SW24
LED LED
M18x1
M18x1
Ø4.1
7.5
Ø4.1
7.5
2x lock washer 2x lock washer
50 10 50
52 62
Fig. 25 Long body, flush version, cable Fig. 26 Long body, non-flush version, cable
4 3
4 3
1 2
1 2
56.5 56.5
4 SW24 4
Ø3 LEDx4 SW24 Ø3 LEDx4
8 8
M18x1
M12x1
M18x1
M12x1
7.5 11 7.5 11
ICB30 [mm]
5 SW36 5
SW36
LED LED
M30x1.5
M30x1.5
Ø5.2
Ø5.2
2x lock washer 2x lock washer
30 12 30
32 44
Fig. 29 Short body, flush version, cable Fig. 30 Short body, non-flush version, cable
4 3 4 3
37.5 1 2 37.5 1 2
5 SW36 5 SW36
Ø3 LEDx4 Ø3 LEDx4
8 8
M30x1.5
M30x1.5
M12x1
M12x1
9 9
LED
M30x1.5
LED
M30x1.5
Ø5.2
Ø5.2
4 3
57.5 4 3
5
1 2 57.5 1 2
SW36 5 SW36
Ø3 LEDx4 Ø3 LEDx4
8 8
M30x1.5
M30x1.5
M12x1
M12x1
9 9
2x lock washer
2x lock washer 12 50
50 87
75
Fig. 35 Long body, flush version, plug Fig. 36 Long body, non-flush version, plug
Installation
d d d
≥ 3 x Sn **
d
Fig. 37 Flush sensor, when installed in damping Fig. 38 Flush sensors, when installed together in
material damping material
d d 2xd d d
≥ 3 x Sn ≥3xd **
d
≥ 2 x Sn
Fig. 39 Non-flush sensor, when installed in damping Fig. 40 Non-flush sensors, when installed together in
material damping material
M30 non-flush
d d 4xd d d
≥ 3 x Sn ≥4xd **
d
≥ 2 x Sn
Fig. 41 Non-flush sensor, when installed in damping Fig. 42 Non-flush sensor, when installed together in
material damping material
≥ 6 x Sn
Fig. 43 For sensors installed opposite each other, a minimum space of 6 x Sn (the nominal sensing dis-
tance) must be observed
Cable version
Delivery contents and compatible components
Delivery contents
Further reading
COPYRIGHT ©2021
Content subject to change. Download the PDF: www.gavazziautomation.com