Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

800 400

800 400
R.L +56.50
600
NOTES:
R.L +55.90
600
1. All dimensions are in millimeter unless otherwise mentioned & levels in meter . Only written dimensions
are to be followed.
2. 25 mm premoulded bituminous expansion pad shall be provided at expansion joint.
3. Position of Returnwalls, Railings, Guard post, shall be decided by Engineer in charge.
4. Water spouts of 100mm dia G.I pipe are provided @ 3 m c/c.
5. Concrete shall have minimum 28 days characteristic strength on 150 mm cubes for elements of
superstructure shall be 20Mpa.

1500
800 6. High strength O.P.C should be used of 43 Grade conforming to IS: 12269.

1500
R.L VARIES FROM R.L
+50.00 TO R.L +47.50 800 7. All reinforcement bars shall be HYSD Fe-500 conforming to IS:1786-2008.
R.L +50.00
8. Cover in deck slab is 40 mm.
R.L +47.00 9. Available suitable steel sheet pile conforming to I.S2314-1986.
R.L +48.80
10. R.C.C Work shall be conform to IS 456-2000.
11. The section of various component may be adjusted as per site
4300 1200 5000 12. Any discrepancy noticed in the drawing should be brought to the notice of the chief engineer.
3500 1200 5000
13. The minimum cover in bottom raft is 60 mm and in other component 40 mm.
10500
9700 14. Earthen embankment of bund must be negotiated.
ABUTMENT 15. Angle of internal friction of back fill material of wing wall and abutment should not be less then 30 deg.
SECTION C-C ABUTMENT
SECTION B-B 16. Joint with water seal shall be provided at all junction of structure.
17. The actual dimension of block outs , embedded parts & gate shall be obtained from gate design.
18. Reinforcement in H/R abutment , wing wall are same as main structure.
WEIR AXIS
HYDRAULIC PARTICULARS OF WEIR
A
B C D

EXPANSION JOINT WITH SEAL

EXPANSION JOINT WITH SEAL

X DIVIDE WALL X

S- 3:1

1200

600
5000
550 500 500
5000

550
500

JOINT WITH 3250


3550 JOINT WITH 3250 3625 SEAL
SEAL 3625 3250 3250 3250 3250 3250

B C
A
9000 D 20000 COUNTERFORT
11200 2500
SPECIFICATION OF MATERIAL TO BE USED
R.L +57.15
R.L +55.90 R.L +55.90
U/S WING WALL R.L +54.90 GATE GROOVE

VERTICAL JOINT VERTICAL JOINT D/S WING WALL R.L +54.90


WITH SEAL WITH SEAL
FLOW VERTICAL JOINT
WITH SEAL

GOVT. OF BIHAR
R.L +50.00 WATER RESOURCES DEPARTMENT
CHIEF ENGINEER , IRRIGATION CREATION W.R.D DARBHANGA
3:1
R.L +48.80 R.L +48.50 CONSTRUCTION OF GATED WEIR & ALLIED STRUCTURES IN THE
R.L +47.50 RIVER SUGERWAY AT MADANPATTI , PHULPARAS BLOCK MADHUBANI
300 mm TH. PCC M 10
R.L +47.00
R.L +46.30
600 MM TH. Western Kosi Canal division Design and Mont. Division Western Kosi Canal Circle
Jhanjharpur Jhanjharpur
INVERTED Darbhanga
Approved by
FILTER

Design and Mont. Circle IRRIGATION CREATION W.R.D DARBHANGA


SECTION AT X - X : ABUTMENT , U/S WING WALL ,D/S WING WALL Darbhanga

You might also like