Professional Documents
Culture Documents
HF TETPOR II-Rev 3A
HF TETPOR II-Rev 3A
HF TETPOR II-Rev 3A
Filter Cartridges
• air / gas filters
• polytetrafluoroethylene PTFE
Performance Characteristics
1000 700
14 10
900
9
Differential Pressure (mbar)
600
12
Differential Pressure (psi)
800 0 barg
8
0 barg 500
700 10 7
600 6
8 400
500 5
6 300
400 4
2 barg 2 barg
300 4 200 3
200 2
2 100
100 1
0 0 0 0
0 100 200 300 400 500 600 700 0 20 40 60 80 100 120 140 160 180
Flow (Nm / hr) (air @ 21 °C)
3
Flow (Nm / hr) (air @ 21 °C)
3
Flow rates for other sizes available upon request Flow rates for other sizes available upon request
Specifications
Materials of Construction Sterilisation Integrity Test Data
Filtration Membrane: Polytetrafluoroethylene HIGH FLOW TETPOR II cartridges can be All cartridges are integrity tested prior to
PTFE in situ steam sterilised for up to 225 cycles despatch by the pressure decay and aerosol
Upstream Support: Polypropylene at 142 °C (287.6 °F). challenge test methods. Values are for
Downstream Support: Polypropylene cartridges wetted with 60 / 40 IPA / Water.
Inner Support Core: 316L Stainless Steel Retention Characteristics Cartridge Test Diffusional Water Water Water
Outer Protection Cage: Polypropylene HIGH FLOW TETPOR II cartridges have been
Pressure Flow Intrusion
Test Pressure
Intrusion Flow
End Caps: Polypropylene fully validated as 0.2 micron sterilising grade (bar) (psi) (ml / min) (barg) (psig) (ml / 10 min) (µl / 10 min)
End Cap Insert: Polysulphone filter cartridges, for compressed air and gas D 0.8 11.6 0.6 2.5 36.2 N/A N/A
Standard o-rings: Silicone applications. They exceed liquid bacterial C 0.8 11.6 1.1 2.5 36.2 N/A N/A
B 0.8 11.6 2.8 2.5 36.2 2.3 657
challenge levels as recommended by ASTM+.
A 0.8 11.6 5.6 2.5 36.2 4.6 1314
Food and Biological Safety In addition, HIGH FLOW TETPOR II is also
K 0.8 11.6 7.70 2.5 36.2 6.4 1828
Materials conform to the relevant validated by aerosol bacterial and 10¨ 0.8 11.6 16.50 2.5 36.2 13.5 3857
requirements of 21CFR Part 177, MS-2 Coliphage challenge testing. 20¨ 0.8 11.6 33.00 2.5 36.2 27.0 7714
EC1935 / 2004 and current USP Plastics +ASTM American Society for Testing and Materials 30¨ 0.8 11.6 49.50 2.5 36.2 40.5 11571
Class VI - 121 °C and ISO10993 equivalents.
Ordering Information
ZHFT / -
Parker domnick hunter has a continuous policy of product development and although the Company
reserves the right to change specifications, it attempts to keep customers informed of any alterations.
This publication is for general information only and customers are requested to contact our Process
Filtration Sales Department for detailed information and advice on a products suitability for specific
applications. All products are sold subject to the company’s Standard conditions of sale.
12/08 Rev. 3A