Date 31/03/2024

Vessel MV ACHUS
MECHANICAL DEPARTMENT Order No./Job No. NDP241008/20BB001
QUALITY CONTROL
MEASUREMENT REPORT

Subject : Stern tube alignment readings. (Initial)


STERN ALIGNMENT

OD BOX
Fwd Bearing Aft Bearing
Laser Transmeter
Gearbox 2 3 4 5
1

2180
2427
3962
4495

GearBox Stern tube FWD Housing Stern tube AFT Housing


Fwd end of Aft end of Fwd end of Aft end of
Ref. GearBox
Fwd Housing Fwd Housing Fwd Housing Fwd Housing
1 2 3 4 5
Distances 0 2180 2427 3962 4495
Vertical
0.00 0.06 0.35 3.70 4.84
Deviation
Horizontal Deviation 0.00 -2.74 -2.67 -1.66 -1.23
Ref. Point

Vertical Alignment
Vertical Deviation (mm)

6.00 4.84 Top


3.70
4.00
2.00 0.00 0.06 0.35
0.00
-2.00 Bottom
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Distances (mm)

Horizontal Alignment
0.00
0.00
Stbd.
Horizontal Deviation (mm)

-0.50 -1.23
-1.00 -1.66
-1.50
-2.00 -2.74 -2.67
-2.50
-3.00
-3.50
Port
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Distances (mm)

Measurement Condition

P Before Repair After Repair


Note: Witness by chief engineer.
Instrument used Easy laser E710
Serial No. 74287 ( Calibration due- May 2025)
Range 0~40000
Measuring units mm
Measured By 26857

Q.C Supervisor Incharge Supervisor Owner Representative

26857/1000459

Form No. MD/Q.C/02/Rev.2 1 of 1