Spectrum Simulacion Clinica Avidanti 20240305

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Annual Production Report produced by Andres Pombo

Design 1 Diacor, Soacha


 Report  System Metrics  Project Location

Project Name Diacor Design Design 1

Project Address Soacha Module DC


218.1 kW
Nameplate
Andres Pombo
Prepared By Inverter AC 180.0 kW
andres@spectrumenergy.co
Nameplate Load Ratio: 1.21

Annual
268.7 MWh
Production

Performance
77.9%
Ratio

kWh/kWp 1,231.9

TMY, 10km Grid, meteonorm


Weather Dataset
(meteonorm)

4381389044-d85978f13c-33ed88bd0f-
Simulator Version
48a8c36a47

 Monthly Production  Sources of System Loss

30k
AC System:
System: 1.9% Shading: 1.7%
Shading:
Inverters: 1.9%
Inverters:
Reflection: 3.4%
Reflection:
Clipping: 0.4%
Clipping:
20k
Wiring: 0.4%
Wiring:
kWh

Soiling: 3.0%
Soiling:
10k Mismatch: 4.6%
Mismatch:

Irradiance: 0.9%
Irradiance:

0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Temperature: 6.2%
Temperature:

GHI POA Shaded Nameplate Grid


Month
(kWh/m2) (kWh/m2) (kWh/m2) (kWh) (kWh)
January 154.9 159.8 158.0 32,342.1 27,074.9
February 135.6 138.1 136.3 27,913.3 23,502.3
March 139.5 140.4 138.0 28,217.8 23,858.1
April 122.0 120.7 118.2 24,171.3 20,373.9
May 117.3 115.9 113.3 23,086.8 19,658.5
June 114.4 112.1 109.1 22,177.4 19,030.4
July 125.0 122.1 118.9 24,229.4 20,680.1
August 133.5 132.4 129.9 26,556.5 22,527.7
September 129.1 129.8 127.7 26,160.8 21,750.1
October 134.2 136.5 134.6 27,583.6 23,225.0
November 123.0 126.2 124.4 25,400.5 21,696.8
December 141.2 146.4 144.7 29,577.9 25,282.2

© 2024 Aurora Solar 1/3 March 05, 2024


Annual Production Report produced by Andres Pombo

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 2
Annual Global Horizontal Irradiance 1,569.7 Weather Dataset TMY, 10km Grid, meteonorm (meteonorm)
POA Irradiance 1,580.4 0.7%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,553.1 -1.7%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,499.9 -3.4%
Irradiance after Soiling 1,454.9 -3.0% Temperature Model Sandia Model
Total Collector Irradiance 1,455.0 0.0% Rack Type a b Temperature Delta
Nameplate 317,417.6 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 314,640.8 -0.9% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 295,099.8 -6.2% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 281,603.8 -4.6% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 280,345.0 -0.4%
J F M A M J J A S O N D
Constrained DC Output 279,326.9 -0.4% Soiling (%)
3 3 3 3 3 3 3 3 3 3 3 3
Inverter Output 274,000.3 -1.9%
Irradiation Variance 5%
Energy to Grid 268,660.0 -1.9%
Temperature Metrics Cell Temperature
4° C
Spread
Avg. Operating Ambient Temp 15.2 °C
Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 29.4 °C
Simulation Metrics AC System Derate 1.50%

Operating Hours 4494 Maximum Angle Backtracking


Trackers
Solved Hours 4494 60° Disabled
Uploaded
Module Characterization
Module By
Characterizations JAM72S30-565/LR (1500V) Spec Sheet
HelioScope
(JA Solar) Characterization, PAN
Component Device Uploaded By Characterization
Characterizations Solis-60K-LV-5G (Solis) HelioScope Spec Sheet

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
3 (180.0 Wiring Zone - 5-20 Along Racking
Inverters Solis-60K-LV-5G (Solis)
kW)
AC Panels 3 input AC Panel 1
 Field Segments
AC Home
10 AWG (Copper) 3 (70.3 m) Intrarow Frame
Runs Description Racking Orientation Tilt Azimuth Frames Modules Power
Spacing Size
AC Home
500 MCM (Copper) 1 (74.1 m) Field Segment Landscape 39.6
Runs Fixed Tilt 5° 149.5° 0.7 m 2x1 35 70
1 (Horizontal) kW
21 (1,439.2
Strings 10 AWG (Copper) Field Segment Landscape 23.7
m) Fixed Tilt 5° 150° 0.7 m 2x1 21 42
2 (Horizontal) kW
JA Solar, JAM72S30-565/LR 386 (218.1
Module Field Segment Landscape 13.6
(1500V) (565W) kW) Fixed Tilt 5° 150° 0.7 m 2x1 12 24
3 (Horizontal) kW
Field Segment Flush 141.3
Portrait (Vertical) 5° 150° 0.0 m 1x1 250 250
4 Mount kW

© 2024 Aurora Solar 2/3 March 05, 2024


Annual Production Report produced by Andres Pombo

 Detailed Layout

© 2024 Aurora Solar 3/3 March 05, 2024

You might also like