1
Coriolis Mass Flow
xFC300 Toolbox
z A Hardware & Software tool for the GDC-based electronics from KROHNE
z Data recording
2
Coriolis Mass Flow
3
Coriolis Mass Flow
4
Coriolis Mass Flow
Data Logger
5
Coriolis Mass Flow
Recording direct to PC
z All the measurement and diagnostic values are saved in the background
z All these values can be exported in an Excel file format for further process analysis and
diagnosis
6
Coriolis Mass Flow
Direct connection
with USB-GDC
Adapter
7
Coriolis Mass Flow
z Select Logging > Start (F5) to start logging, or Logging > Stop (F6) to stop logging
8
Coriolis Mass Flow
Recording direct to PC
9
Coriolis Mass Flow
Recording direct to PC
10
Coriolis Mass Flow
Trace setup
11
Coriolis Mass Flow
Graph Title
z The default Graph Title contains the Converter Electronics type followed by the start
date and time
z Select Setup > Title (or click the title) to display the Edit Title dialog
12
Coriolis Mass Flow
z Pan
z Hold down the middle mouse button (or scroll wheel) and move the graph up or down.
13
Coriolis Mass Flow
14
Coriolis Mass Flow
Auto Scale
15
Coriolis Mass Flow
Auto Scale
16
Coriolis Mass Flow
Go To Time
z The Go To Time dialog is used to set the current scroll position without altering the
scale
z Right click on the graph to open the context menu and then select Go To…
z Enter the new scroll position and then select OK
17
Coriolis Mass Flow
Saving file
Saving file
19
Coriolis Mass Flow
z CSV files can be used by other applications, for example Microsoft Excel
z Select File > Export > CSV File
20
Coriolis Mass Flow
z The include Header option writes the Converter Electronics type, CG number and
electronic serial number at the top of the CSV File
z The selected Data Parameters specify the data that is to be exported in columns
z If Data Padding On is selected, every position in the CSV File contains data
z If Data Padding Off is selected, the CSV File will have gaps in the data because GDC
measurements are updated at independent sample rates
21
Coriolis Mass Flow
Time Mass Flow Process Temperature Density Tube Frequency MT Stain Sensor A Sensor B Drive Level
secs kg/h °C kg/m³ Hz Ohm % %
1126.029348 0 22.91997681 1200 314.2046509 392.9199829 80 81 0
1126.131223 0 22.91997681 1200 314.2046509 392.9199829 80 81 0
1126.233098 0 22.91997681 1200 314.1722717 392.8999939 80 81 0
1126.334973 0 22.91997681 1200 314.1722717 392.8999939 80 81 0
1126.436848 0 22.91997681 1200 314.1722717 392.8999939 80 81 0
1126.538723 0 22.91997681 1200 314.119751 392.8999939 80 80 0
1126.640598 0 22.91997681 1200 314.119751 392.8999939 80 80 0
1126.742473 0 22.91997681 1200 314.119751 392.8999939 80 80 0
1126.84414 0 22.91997681 1200 314.1674805 392.8599854 80 81 0
1126.946015 0 22.91997681 1200 314.1674805 392.8599854 80 81 0
1127.04789 0 22.91997681 1200 314.180542 392.8599854 80 81 0
1127.149765 0 22.89998779 1200 314.180542 392.8599854 80 81 0
1127.25164 0 22.91997681 1200 314.180542 392.8599854 80 81 0
1127.353515 0 22.91997681 1200 314.1949463 392.8599854 80 80 0
1127.45539 0 22.91997681 1200 314.1949463 392.8599854 80 80 0
1127.557265 0 22.91997681 1200 314.1949463 392.8599854 80 80 0
1127.65914 0 22.91997681 1200 314.1317749 392.8599854 80 81 0
1127.761015 0 22.91997681 1200 314.1317749 392.8599854 80 81 0
1127.86289 0 22.91997681 1200 314.1352234 392.9199829 80 81 0
1127.964556 0 22.91997681 1200 314.1352234 392.9199829 80 81 0
1128.066431 0 22.91997681 1200 314.1352234 392.9199829 80 81 0
1128.168306 0 22.91997681 1200 314.1542969 392.8599854 80 81 0
1128.270181 0 22.91997681 1200 314.1542969 392.8599854 80 81 0
1128.372056 0 22.91997681 1200 314.1542969 392.8599854 80 81 0
1128.473931 0 22.91997681 1200 314.1986389 392.8599854 80 81 0
22
Coriolis Mass Flow
Time Mass Flow Process Temperature Density Tube Frequency MT Stain Sensor A Sensor B Drive Level
secs kg/h °C kg/m³ Hz Ohm % %
1126.029348 0 1200 314.2046509 392.9199829 80 81 0
1126.131223 0 314.2046509 392.9199829 80 81 0
1126.233098 0 314.1722717 392.8999939 80 81 0
1126.334973 0 314.1722717 392.8999939 80 81 0
1126.436848 0 314.1722717 392.8999939 80 81 0
1126.538723 0 22.91997681 314.119751 392.8999939 80 80 0
1126.640598 0 314.119751 392.8999939 80 80 0
1126.742473 0 314.119751 392.8999939 80 80 0
1126.84414 0 314.1674805 392.8599854 80 81 0
1126.946015 0 314.1674805 392.8599854 80 81 0
1127.04789 0 1200 314.180542 392.8599854 80 81 0
1127.149765 0 22.89998779 314.180542 392.8599854 80 81 0
1127.25164 0 22.91997681 314.180542 392.8599854 80 81 0
1127.353515 0 314.1949463 392.8599854 80 80 0
1127.45539 0 314.1949463 392.8599854 80 80 0
1127.557265 0 314.1949463 392.8599854 80 80 0
1127.65914 0 314.1317749 392.8599854 80 81 0
1127.761015 0 314.1317749 392.8599854 80 81 0
1127.86289 0 314.1352234 392.9199829 80 81 0
1127.964556 0 314.1352234 392.9199829 80 81 0
1128.066431 0 1200 314.1352234 392.9199829 80 81 0
1128.168306 0 22.91997681 314.1542969 392.8599854 80 81 0
1128.270181 0 314.1542969 392.8599854 80 81 0
1128.372056 0 314.1542969 392.8599854 80 81 0
1128.473931 0 314.1986389 392.8599854 80 81 0
23
Coriolis Mass Flow
z Data from GDC Log Files can be exported to smaller GDC Log Files
z The visible portion of the X Axis specifies the data section to be exported
z Select File > Export > GDC Log File and the Export Current View as GDC Log File
dialog is displayed.
24
Coriolis Mass Flow
25
Coriolis Mass Flow
z Module can be plugged in to the GDC port on the xFC300 display behind the lid and can be set to
log data for several hours or days as required
z All measurement and diagnostic values can be saved and analysed off line at a later date using the
software
26
Coriolis Mass Flow
27
Coriolis Mass Flow
Orientate card as
shown
28
Coriolis Mass Flow
z Data Logger Module will start to log data automatically when connected to the
converter electronics
z Data logging is indicated by the 4 Light Emitting Diodes (LED) flashing in sequence
29
Coriolis Mass Flow
Retrieving data
30
Coriolis Mass Flow
z Data Logger Module only supports micro-SD cards that have the FAT file system
z FAT is also sometimes referred to as FAT16
z If the micro-SD card is not formatted with the FAT file system
z Use Windows to format the card
31
Coriolis Mass Flow
32
Coriolis Mass Flow
33
Coriolis Mass Flow
34
Coriolis Mass Flow
z Hardware required
z USB-GDC Adapter
35
Coriolis Mass Flow
z Click “Next”
36
Coriolis Mass Flow
z Click “Browse”
z Locate file
z Click “Open”
z Click “Next”
37
Coriolis Mass Flow
z Click “Finish”
z Program ends
38
Coriolis Mass Flow
z Note the .bin file is based on the User Interface version applicable at the time
z Bin files is based on configuration settings at the point the meter was produced
z Subsequent changes are not recognised or traceable
z Only possible with meters that have been fully supplied as a system
z i.e. Not available where sensor & electronics have been supplied separately
39
Coriolis Mass Flow
Availability
40
Coriolis Mass Flow
41
Coriolis Mass Flow
42
Coriolis Mass Flow
43