Professional Documents
Culture Documents
Alan Segovia - Project - VC0-Report1
Alan Segovia - Project - VC0-Report1
Alan Segovia - Project - VC0-Report1
PVsyst TRIAL
PVsyst - Simulation report
Grid-Connected System
PVsyst TRIAL
PVsyst TRIAL
Autor(a)
PVsyst TRIAL
Project: Alan Segovia
Variant: Nueva variante de simulación
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
PVsyst TRIAL
with v7.3.1
Project summary
Geographical Site Situation Project settings
La Argelia Latitude -0.27 °S Albedo 0.20
Ecuador Longitude -78.53 °W
Altitude 2850 m
Time zone UTC-5
Meteo data
La Argelia
Meteonorm 8.1 (2016-2021), Sat=100% - Sintético
System summary
PVsyst TRIAL
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters Battery pack
Nb. of modules 24 units Nb. of units 1 unit Storage strategy: Self-consumption
Pnom total 10.92 kWp Pnom total 10.00 kWac Nb. of units 20 units
Pnom ratio 1.092 Voltage 120 V
Capacity 478 Ah
PVsyst TRIAL
Results summary
Produced Energy 14644 kWh/year Specific production 1341 kWh/kWp/year Perf. Ratio PR 82.12 %
Used Energy 91104 kWh/year Solar Fraction SF 16.07 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Predef. graphs 7
Single-line diagram 8
PVsyst TRIAL
PVsyst TRIAL
01/03/24 PVsyst Evaluation mode Page 2/8
Project: Alan Segovia
Variant: Nueva variante de simulación
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
PVsyst TRIAL
with v7.3.1
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 45 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PVsyst TRIAL
91.1 MWh/Year
Storage
Kind Self-consumption
Charging strategy Discharging strategy
When excess solar power is available As soon as power is needed
PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model ODA-455-36-MHT Model NXV0010
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 455 Wp Unit Nom. Power 10.00 kWac
Number of PV modules 24 units Number of inverters 1 unit
PVsyst TRIAL
Nominal (STC) 10.92 kWp Total power 10.0 kWac
Modules 2 Strings x 12 In series Operating voltage 340-800 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.09
Pmpp 9.96 kWp
U mpp 449 V
I mpp 22 A
Battery Storage
Battery
PVsyst TRIAL
Manufacturer Generic
Model PVX-2580L
Battery pack Battery Pack Characteristics
Nb. of units 10 in series Voltage 120 V
x2 in parallel Nominal Capacity 478 Ah (C10)
Discharging min. SOC 20.0 % Temperature Average between fixed 20 °C
Stored energy 45.9 kWh and External
Battery input charger
Model Generic
Max. charg. power 4.6 kWdc
Max./Euro effic. 97.0/95.0 %
Battery to Grid inverter
Model Generic
Max. disch. power 10.5 kWac
PVsyst TRIAL
Max./Euro effic. 97.0/95.0 %
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
PVsyst TRIAL
with v7.3.1
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 336 mΩ Loss Fraction -0.8 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
01/03/24 PVsyst Evaluation mode Page 4/8
Project: Alan Segovia
Variant: Nueva variante de simulación
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
PVsyst TRIAL
with v7.3.1
Main results
System Production
Produced Energy 14644 kWh/year Specific production 1341 kWh/kWp/year
Used Energy 91104 kWh/year Performance Ratio PR 82.12 %
Solar Fraction SF 16.07 %
Battery aging (State of Wear)
Cycles SOW 99.9 %
Static SOW 80.0 %
PVsyst TRIAL
Balances and main results
PVsyst TRIAL
January
February
March
April
GlobHor
kWh/m²
177.9
139.5
163.7
159.6
DiffHor
kWh/m²
70.46
72.60
82.51
65.09
T_Amb
°C
14.22
14.13
14.10
13.83
GlobInc
kWh/m²
94.9
93.0
127.7
147.3
GlobEff
kWh/m²
85.0
86.4
120.9
142.3
EArray
kWh
879
890
1235
1430
E_User
kWh
7738
6989
7738
7488
E_Solar
kWh
834
828
1155
1337
E_Grid
kWh
0.000
0.000
0.000
0.000
EFrGrid
kWh
6904
6161
6583
6151
May 170.9 62.93 14.08 180.0 175.8 1743 7738 1632 0.000 6105
June 168.8 60.95 13.93 188.9 185.3 1836 7488 1724 0.000 5764
July 180.5 57.28 13.97 197.6 193.5 1905 7738 1789 0.000 5949
August 190.3 65.88 14.52 186.4 181.0 1802 7738 1693 0.000 6045
September 167.2 66.54 14.28 139.3 132.6 1334 7488 1246 0.000 6242
October 154.8 69.40 14.25 106.5 99.2 1013 7738 939 0.000 6799
November 146.5 72.13 13.84 86.6 78.9 815 7488 749 0.000 6739
PVsyst TRIAL
December 164.1 71.34 14.00 84.9 75.7 784 7738 719 0.000 7019
Year 1983.7 817.10 14.10 1633.1 1556.7 15665 91104 14644 0.000 76460
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_User Energy supplied to the user
T_Amb Ambient Temperature E_Solar Energy from the sun
GlobInc Global incident in coll. plane E_Grid Energy injected into grid
GlobEff Effective Global, corr. for IAM and shadings EFrGrid Energy from the grid
PVsyst TRIAL
01/03/24 PVsyst Evaluation mode Page 5/8
Project: Alan Segovia
Variant: Nueva variante de simulación
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
PVsyst TRIAL
with v7.3.1
Loss diagram
1984 kWh/m² Global horizontal irradiation
PVsyst TRIAL
-0.93% PV loss due to irradiance level
PVsyst TRIAL
-0.06% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
14623 kWh Available Energy at Inverter Output
PVsyst TRIAL
from grid from solar
PVsyst TRIAL
01/03/24 PVsyst Evaluation mode Page 6/8
Project: Alan Segovia
Variant: Nueva variante de simulación
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
PVsyst TRIAL
with v7.3.1
Predef. graphs
Diagrama entrada/salida diaria
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
01/03/24 PVsyst Evaluation mode Page 7/8
PVsyst V7.3.1
VC0, Simulation date:
01/03/24 20:17
with v7.3.1