Client:

D01 D01 D01 D01


────── ────── ────── ──────
T11 T12 T13 T14 Ministry of Housing, Utilities
8300 9600 8550 & Urban Communities

New Urban Communities


D01
────── Authority
T01
Project Engineer:

Shair & Partners


7000
Contractor:

D01
──────
T02 Consultant: ®

SARDINI GROUP INC


萨蒂尼工程顾问有限公司
7800

Record Engineer:

D01 Project Name:


──────
T03 Alamein Downtown Towers

Key Plan:
7800

D01
──────
T04

GENERAL NOTES
1- ALL TENDON PROFILE ARE GIVEN TO CENTROID OF
7800

TENDON AND CENTERLINE AT ANCHORAGE.


2- ALL TENDON PROFILE ARE STRAIGHT UNLESS NOTED
OTHERWISE.

3- LEGEND :

DEAD END ANCHORAGE

D01 LIVE END ANCHORAGE


──────
STRESSING PAN
T05
4- TENDON NOTATION:

(100)

(100)
D01 D01 D01 D01 D01
────── ────── ────── ────── ────── Tendon ID/ No. of Strands
Level to Level to Level to
T15 T16 T17 T18 T19 centroid centroid centroid
7800

of tendon at of tendon of tendon at


stressing end dead-end

5- STRAND TYPE : ALL STRAND SHALL BE 12.7MM DIA.


(U.N.O.).
7800 7800 7800 7800 9100
6- MINIMUM TENDON OFFSET FROM CENTRE LINE TO
2 OPENING SHALL BE 100MM.

D01 7- STRENGTH OF CONCRETE AT TRANSFER SHALL NOT BE


────── LESS THAN 30 Mpa (CUBE STRENGTH = 30 Mpa).
T06
8- TENDONS TO HAVE PRIORITY IN CASE OF CLASHES
WITH REBAR.

9- ALL THE SLAB/BEAM PROFILE VALUES ARE WITH


RESPECT TO THE BOTTOM OF THE CORRESPONDING SLAB.

10- TENDON FORCE FOR EACH STRAND SHALL BE


7750

138 KN FOR 12.70mm STRAND (75% GUTS).


2
11- KEEP EDGE OF SLAB AND ADJACENT BAYS SHORED
UNTIL THE POURING STRIP IS CAST AND CONCRETE HAS
ATTAINED THE REQUIRED CONCRETE CUBIC STRENGTH.
AS PER PROJECT SPECIFICATIONS.

12-THE PROPING SHALL BE USED AND THE CALCULATION


FOR THE SUPPORTING SLAB SHALL BE SUBMITTED
D01 TO THE ENGINEER FOR APPROVEL.
──────
T07 13-THIS DRAWINGS SET IS VALID FOR RESIDENTIALTOWERS
D02,D01M AND D02M. D01M IS MIRRORED FROM D01
AND D02M IS MIRRORED FROM D02.

14-THE LOCATION AND DIMENSION OF PAN


BOX REFER TO FLOOR FRAME PLAN
DWG-CSCEC-D01-FD-ST-SC-01-XX-00-0000-XX
8600

D01
──────
T08
300
8600

Revision Table:

D01
──────
T09
02 For Approved AUG.2022 S.Z.
01 For Approved AUG.2022 S.Z.
00 For Approved JUL.2022 S.Z.
No. Description Date App.
5850

Drawing Title:

D01-RESIDENTIAL TOWER

D01 LEVEL 07 TENDON LAYOUT


────── Y-DIRECTION PLAN
T10 2

2 2

Designed Checked Approved

C.W. X.K. S.Z.

LEVEL 07 TENDON LAYOUT Y-DIRECTION PLAN Drawn Date Scale

G.Z. AUG.2022 1:100


SC: 1 : 100
DWG-CSCEC-D01-FD-ST-SC-02-07-00-0004-02
Document Contractor' s
Building Phase Trade Discipline Elements Floor Level Part No. Sequence No . Rev.
Type Name