Professional Documents
Culture Documents
Theis Bellavista
Theis Bellavista
Theis Bellavista
Well 1
Pumping Test - Water Level Data Page 1 of 1
Project: Bellavista Test
Number: 1
Client: Jaime Jimenez Pinzón
Location: Toca, Boyacá Pumping Test: Theis Analysis Pumping Well: Well 1
Test Conducted by: José Santana Test Date: 29/08/2023 Discharge Rate: 2.38 [l/s]
Observation Well: Well 1 Static Water Level [m]: 38.00 Radial Distance to PW [m]: -
Time Water Level Drawdown
[min] [m] [m]
1 1 42.02 4.02
2 2 43.10 5.10
3 3 43.70 5.70
4 4 44.03 6.03
5 5 44.30 6.30
6 6 44.50 6.50
7 7 44.70 6.70
8 8 44.90 6.90
9 9 45.00 7.00
10 10 45.10 7.10
11 12 45.55 7.55
12 14 46.20 8.20
13 16 46.39 8.39
14 18 46.54 8.54
15 20 46.67 8.67
16 25 47.00 9.00
17 30 47.17 9.17
18 35 47.41 9.41
19 40 47.51 9.51
20 45 47.80 9.80
21 50 47.90 9.90
22 60 48.27 10.27
23 70 48.34 10.34
24 80 48.42 10.42
25 90 48.62 10.62
26 100 48.71 10.71
27 110 48.75 10.75
28 120 48.89 10.89
29 140 49.05 11.05
30 160 49.12 11.12
31 180 49.35 11.35
32 210 49.55 11.55
33 240 49.65 11.65
34 270 49.68 11.68
35 300 49.84 11.84
36 330 50.06 12.06
37 360 50.14 12.14
38 420 50.11 12.11
39 480 50.06 12.06
40 540 50.09 12.09
41 600 50.08 12.08
42 720 50.06 12.06
Pumping Test Analysis Report
1E1
1E0
Well 1
Calculation using Theis
Observation Well Transmissivity Hydraulic Conductivity Storage coefficient Radial Distance to PW
[m²/d] [m/d] [m]
0 -2 -2
Well 1 1.73 × 10 1.54 × 10 3.15 × 10