(312.4) 3A Sanitary In-Line Turbine Flow Meter
Meets 3A sanitary standard number 28-03 requirements
Available in CIP/SIP and COP/SOP environments
Accuracy: ±1% of reading
Repeatability: ±0.1% Model B2800 Flow Monitor
Flow ranges from 0.6 - 3 GPM to 40 - 400 GPM
Meter sizes 3/8 to 2 inches (9.5 to 50 mm)
HAND-HELD Microprocessor-based flow monitor and totalizer
Connection sizes: 3/4, 1-1/2, and 2-1/2 inches
SWIVEL MOUNT Use with Blancett® turbine flow meters as well as other flow meters
.75 (19.0) NPT Port
with a frequency output
.75
4.25
(107.9)
(19.0) 2.75 Battery (1.5 VDC) and Loop-powered (4-20 mA) versions available
(69.9)
Meter, Remote, Panel and Swivel mount versions available
5.0
(127)
Hand-Held and Explosion-Proof models also available
4.25 4.75
(107.9) (120.7) 8635 Washington Avenue, Racine, WI 53406-3738 U.S.A.
E-mail: info@blancett.com
1-800-235-1638 www.blancett.com ®
Flow Meters © 2006 Blancett Printed in USA 5/06 Form No. 2800
PANEL MOUNT EXPLOSION-PROOF Division of Racine Federated Inc. Blancett is a registered trademark of Racine Federated Inc.
CSA is a registered trademark of Canadian Standards Association
QuikSert is a trademark of Racine Federated Inc.
5
Flow Monitor Model B2800 Flow Monitor Model B2800 Flow Monitor Model B2800
Fixed or toggle modes of operation for flow rate and total display
swivel mount plus hand-held versions) Pulse Type Opto-isolated open collector transistor Cable lengths from 10' (3 meters) up to 100' (30.5 meters) sold separately
Battery-powered unit utilizes one “D” size 1.5 volt alkaline Max Voltage 30 VDC Units Display And
battery for up to 3-1/2 years of service Pulse Width (ON State) 20 ms/max pulse rate 20 Hz
Programming Programming Choices Swivel Mount
Keys
Loop-powered, 4-20 mA version available Current (ON State) 0.9 V drop @ 5.0 mA or Capable of adjusting orientation up to 180 degrees
User friendly front panel programming 0.7 V drop @ 0.1 mA Offers additional protection from the sun/elements
Ten point linearization (Advanced model only) Inputs: Magnetic pickup Increased visibility in difficult viewing installations
NEMA 4X enclosure suitable for outdoor monitoring (meter, Frequency Range 1 to 3500 Hz Certifications:
Remote swivel mount also available, consult factory for details
remote, and swivel mount versions) Trigger Sensitivity 30 mV p-p CSA Intrinsically Safe: Class I, Division 1, Groups C & D
NEMA 4X (IP-66) enclosure
(Meter, Remote & Swivel Mount) Class II, Division 1, Groups E, F & G
Intrinsically safe (meter, remote and swivel mount versions) Over Voltage Protected 30 VDC 8 digit 0.7 inches (18 mm) numeric display (rate/total display;
CE: (Meter, Remote & Swivel Mount) IEC 61326-1 programming choices)
Microprocessor-based, low power consumption Frequency
Measurement ±0.1% CSA: (Panel Mount Only) Ordinary Area 8 digit 0.35 inches (9 mm) alphanumeric display (run/programming mode)
Six mounting options: meter, remote, swivel, hand-held, panel or
Accuracy: CSA Hazardous Locations: Class I, Division 1, Groups B, C & D Fixed or toggle modes of operation for flow rate and total display
explosion-proof
Analog Output: (Explosion-Proof Model Only) Class II, Groups E, F & G
Simplified model displays in five selectable units of measure: (Loop-Powered Version) 4-20 mA
Class III, Type 4, T6 @ 70 C Hand-Held
GPM/gallons, LPM/liters, M3PD/cubic meters, BPD/barrels, or Operating
-22 °F (-30 °C) to 158 °F (70 °C) Units of Measure (Rate/total): GPM/gallons, LPM/liters, M3PD/ Battery-powered
M3PH/cubic meters Temperature: (Simplified Version - user selectable) cubic meters, BPD/barrels, Portable, includes handle, extendable cable and sensor dock
Advanced model offers thirteen selectable units of measure: Humidity: 0-90% non-condensing M3PH/cubic meters
gallons, oil barrels, liters, cubic meters, Mgal, MCF, MMCF, On/Off switch for power conservation
Enclosure Rating: Meter, Remote and Swivel mount: Units of Measure (Total): Gallons, Oil Barrels, Liters, Cubic Magnetic pickup included with monitor
cubic ft, Mliters, acre ft, liquid barrels, lbs, or kgs NEMA/UL/CSA Type 4X (IP-66) (Advanced Version - user selectable) Meters, MGal, Cubic Ft, MLiters,
Advanced model allows selection of time intervals for rate MCF, MMCF, Acre Ft, Liquid Barrels, 8 digit 0.7 inches (18 mm) numeric display (rate/total display;
Panel mount: NEMA 4 (front only) programming choices)
measurement in either day, hour, minute, or second Hand-Held: General Purpose Lbs, Kgs
8 digit 0.35 inches (9 mm) alphanumeric display (run/programming mode)
Advanced model includes gas measurement with correction Explosion-proof: NEMA 4X (IP-66) Time Intervals (Rate): Day, Hour, Minute, Second
(Advanced Version - user selectable) Fixed or toggle modes of operation for flow rate and total display
software for pressure and temperature
General Purpose enclosure
Fixed or toggle modes of operation for flow rate and total display
swivel mount plus hand-held versions) Pulse Type Opto-isolated open collector transistor Cable lengths from 10' (3 meters) up to 100' (30.5 meters) sold separately
Battery-powered unit utilizes one “D” size 1.5 volt alkaline Max Voltage 30 VDC Units Display And
battery for up to 3-1/2 years of service Pulse Width (ON State) 20 ms/max pulse rate 20 Hz
Programming Programming Choices Swivel Mount
Keys
Loop-powered, 4-20 mA version available Current (ON State) 0.9 V drop @ 5.0 mA or Capable of adjusting orientation up to 180 degrees
User friendly front panel programming 0.7 V drop @ 0.1 mA Offers additional protection from the sun/elements
Ten point linearization (Advanced model only) Inputs: Magnetic pickup Increased visibility in difficult viewing installations
NEMA 4X enclosure suitable for outdoor monitoring (meter, Frequency Range 1 to 3500 Hz Certifications:
Remote swivel mount also available, consult factory for details
remote, and swivel mount versions) Trigger Sensitivity 30 mV p-p CSA Intrinsically Safe: Class I, Division 1, Groups C & D
NEMA 4X (IP-66) enclosure
(Meter, Remote & Swivel Mount) Class II, Division 1, Groups E, F & G
Intrinsically safe (meter, remote and swivel mount versions) Over Voltage Protected 30 VDC 8 digit 0.7 inches (18 mm) numeric display (rate/total display;
CE: (Meter, Remote & Swivel Mount) IEC 61326-1 programming choices)
Microprocessor-based, low power consumption Frequency
Measurement ±0.1% CSA: (Panel Mount Only) Ordinary Area 8 digit 0.35 inches (9 mm) alphanumeric display (run/programming mode)
Six mounting options: meter, remote, swivel, hand-held, panel or
Accuracy: CSA Hazardous Locations: Class I, Division 1, Groups B, C & D Fixed or toggle modes of operation for flow rate and total display
explosion-proof
Analog Output: (Explosion-Proof Model Only) Class II, Groups E, F & G
Simplified model displays in five selectable units of measure: (Loop-Powered Version) 4-20 mA
Class III, Type 4, T6 @ 70 C Hand-Held
GPM/gallons, LPM/liters, M3PD/cubic meters, BPD/barrels, or Operating
-22 °F (-30 °C) to 158 °F (70 °C) Units of Measure (Rate/total): GPM/gallons, LPM/liters, M3PD/ Battery-powered
M3PH/cubic meters Temperature: (Simplified Version - user selectable) cubic meters, BPD/barrels, Portable, includes handle, extendable cable and sensor dock
Advanced model offers thirteen selectable units of measure: Humidity: 0-90% non-condensing M3PH/cubic meters
gallons, oil barrels, liters, cubic meters, Mgal, MCF, MMCF, On/Off switch for power conservation
Enclosure Rating: Meter, Remote and Swivel mount: Units of Measure (Total): Gallons, Oil Barrels, Liters, Cubic Magnetic pickup included with monitor
cubic ft, Mliters, acre ft, liquid barrels, lbs, or kgs NEMA/UL/CSA Type 4X (IP-66) (Advanced Version - user selectable) Meters, MGal, Cubic Ft, MLiters,
Advanced model allows selection of time intervals for rate MCF, MMCF, Acre Ft, Liquid Barrels, 8 digit 0.7 inches (18 mm) numeric display (rate/total display;
Panel mount: NEMA 4 (front only) programming choices)
measurement in either day, hour, minute, or second Hand-Held: General Purpose Lbs, Kgs
8 digit 0.35 inches (9 mm) alphanumeric display (run/programming mode)
Advanced model includes gas measurement with correction Explosion-proof: NEMA 4X (IP-66) Time Intervals (Rate): Day, Hour, Minute, Second
(Advanced Version - user selectable) Fixed or toggle modes of operation for flow rate and total display
software for pressure and temperature
General Purpose enclosure
Fixed or toggle modes of operation for flow rate and total display
swivel mount plus hand-held versions) Pulse Type Opto-isolated open collector transistor Cable lengths from 10' (3 meters) up to 100' (30.5 meters) sold separately
Battery-powered unit utilizes one “D” size 1.5 volt alkaline Max Voltage 30 VDC Units Display And
battery for up to 3-1/2 years of service Pulse Width (ON State) 20 ms/max pulse rate 20 Hz
Programming Programming Choices Swivel Mount
Keys
Loop-powered, 4-20 mA version available Current (ON State) 0.9 V drop @ 5.0 mA or Capable of adjusting orientation up to 180 degrees
User friendly front panel programming 0.7 V drop @ 0.1 mA Offers additional protection from the sun/elements
Ten point linearization (Advanced model only) Inputs: Magnetic pickup Increased visibility in difficult viewing installations
NEMA 4X enclosure suitable for outdoor monitoring (meter, Frequency Range 1 to 3500 Hz Certifications:
Remote swivel mount also available, consult factory for details
remote, and swivel mount versions) Trigger Sensitivity 30 mV p-p CSA Intrinsically Safe: Class I, Division 1, Groups C & D
NEMA 4X (IP-66) enclosure
(Meter, Remote & Swivel Mount) Class II, Division 1, Groups E, F & G
Intrinsically safe (meter, remote and swivel mount versions) Over Voltage Protected 30 VDC 8 digit 0.7 inches (18 mm) numeric display (rate/total display;
CE: (Meter, Remote & Swivel Mount) IEC 61326-1 programming choices)
Microprocessor-based, low power consumption Frequency
Measurement ±0.1% CSA: (Panel Mount Only) Ordinary Area 8 digit 0.35 inches (9 mm) alphanumeric display (run/programming mode)
Six mounting options: meter, remote, swivel, hand-held, panel or
Accuracy: CSA Hazardous Locations: Class I, Division 1, Groups B, C & D Fixed or toggle modes of operation for flow rate and total display
explosion-proof
Analog Output: (Explosion-Proof Model Only) Class II, Groups E, F & G
Simplified model displays in five selectable units of measure: (Loop-Powered Version) 4-20 mA
Class III, Type 4, T6 @ 70 C Hand-Held
GPM/gallons, LPM/liters, M3PD/cubic meters, BPD/barrels, or Operating
-22 °F (-30 °C) to 158 °F (70 °C) Units of Measure (Rate/total): GPM/gallons, LPM/liters, M3PD/ Battery-powered
M3PH/cubic meters Temperature: (Simplified Version - user selectable) cubic meters, BPD/barrels, Portable, includes handle, extendable cable and sensor dock
Advanced model offers thirteen selectable units of measure: Humidity: 0-90% non-condensing M3PH/cubic meters
gallons, oil barrels, liters, cubic meters, Mgal, MCF, MMCF, On/Off switch for power conservation
Enclosure Rating: Meter, Remote and Swivel mount: Units of Measure (Total): Gallons, Oil Barrels, Liters, Cubic Magnetic pickup included with monitor
cubic ft, Mliters, acre ft, liquid barrels, lbs, or kgs NEMA/UL/CSA Type 4X (IP-66) (Advanced Version - user selectable) Meters, MGal, Cubic Ft, MLiters,
Advanced model allows selection of time intervals for rate MCF, MMCF, Acre Ft, Liquid Barrels, 8 digit 0.7 inches (18 mm) numeric display (rate/total display;
Panel mount: NEMA 4 (front only) programming choices)
measurement in either day, hour, minute, or second Hand-Held: General Purpose Lbs, Kgs
8 digit 0.35 inches (9 mm) alphanumeric display (run/programming mode)
Advanced model includes gas measurement with correction Explosion-proof: NEMA 4X (IP-66) Time Intervals (Rate): Day, Hour, Minute, Second
(Advanced Version - user selectable) Fixed or toggle modes of operation for flow rate and total display
software for pressure and temperature
General Purpose enclosure
9.25
(235)
1.25
(31.8) .25 (6.4) DIA
(4 HOLES)
7.38
(187.4)
7.00
(177.8) 7.00
(177.8)
12.30
(312.4) 3A Sanitary In-Line Turbine Flow Meter
Meets 3A sanitary standard number 28-03 requirements
Available in CIP/SIP and COP/SOP environments
Accuracy: ±1% of reading
Repeatability: ±0.1% Model B2800 Flow Monitor
Flow ranges from 0.6 - 3 GPM to 40 - 400 GPM
Meter sizes 3/8 to 2 inches (9.5 to 50 mm)
HAND-HELD Microprocessor-based flow monitor and totalizer
Connection sizes: 3/4, 1-1/2, and 2-1/2 inches
SWIVEL MOUNT Use with Blancett® turbine flow meters as well as other flow meters
.75 (19.0) NPT Port
with a frequency output
.75
4.25
(107.9)
(19.0) 2.75 Battery (1.5 VDC) and Loop-powered (4-20 mA) versions available
(69.9)
Meter, Remote, Panel and Swivel mount versions available
5.0
(127)
Hand-Held and Explosion-Proof models also available
4.25 4.75
(107.9) (120.7) 8635 Washington Avenue, Racine, WI 53406-3738 U.S.A.
E-mail: info@blancett.com
1-800-235-1638 www.blancett.com ®
Flow Meters © 2006 Blancett Printed in USA 5/06 Form No. 2800
PANEL MOUNT EXPLOSION-PROOF Division of Racine Federated Inc. Blancett is a registered trademark of Racine Federated Inc.
CSA is a registered trademark of Canadian Standards Association
QuikSert is a trademark of Racine Federated Inc.
5
Model B2800 Related Blancett Products Flow Monitor Model B2800
9.25
(235)
1.25
(31.8) .25 (6.4) DIA
(4 HOLES)
7.38
(187.4)
7.00
(177.8) 7.00
(177.8)
12.30
(312.4) 3A Sanitary In-Line Turbine Flow Meter
Meets 3A sanitary standard number 28-03 requirements
Available in CIP/SIP and COP/SOP environments
Accuracy: ±1% of reading
Repeatability: ±0.1% Model B2800 Flow Monitor
Flow ranges from 0.6 - 3 GPM to 40 - 400 GPM
Meter sizes 3/8 to 2 inches (9.5 to 50 mm)
HAND-HELD Microprocessor-based flow monitor and totalizer
Connection sizes: 3/4, 1-1/2, and 2-1/2 inches
SWIVEL MOUNT Use with Blancett® turbine flow meters as well as other flow meters
.75 (19.0) NPT Port
with a frequency output
.75
4.25
(107.9)
(19.0) 2.75 Battery (1.5 VDC) and Loop-powered (4-20 mA) versions available
(69.9)
Meter, Remote, Panel and Swivel mount versions available
5.0
(127)
Hand-Held and Explosion-Proof models also available
4.25 4.75
(107.9) (120.7) 8635 Washington Avenue, Racine, WI 53406-3738 U.S.A.
E-mail: info@blancett.com
1-800-235-1638 www.blancett.com ®
Flow Meters © 2006 Blancett Printed in USA 5/06 Form No. 2800
PANEL MOUNT EXPLOSION-PROOF Division of Racine Federated Inc. Blancett is a registered trademark of Racine Federated Inc.
CSA is a registered trademark of Canadian Standards Association
QuikSert is a trademark of Racine Federated Inc.
5
More Options and Features.
Same Trusted Brand.
The NEW B3000 Series flow monitor provides you with a flexible, durable,
easy-to-use platform for your flow metering applications. Blancett’s trusted
flow metering technology now offers an exciting new flow monitor with more
options and features than ever before with the B3000 Series.
B 3 0 – C S
Units of Measure
CS) Customer Selectable
Mounting Style
Model
M) Meter
B) Base
R) Remote (cable sold separately)
A) Advanced
S) Swivel
S) Solar
W) Explosion-Proof (Base)* – Loop Power Only
X) Explosion-Proof (Base)* – Battery and Loop Power
Y) Explosion-Proof (Advanced)* – Loop Power Only
Z) Explosion-Proof (Advanced)* – Battery and Loop Power
* For hazardous locations the monitor must be installed on an Explosion-Proof rated meter.
To maintain compliance, optional kit P/N B280-737 for meter mounting is required.
MODEL: XXXXXXXXXX
SERIAL: XXXXXXXXXX
Electrical and Hazardous
Pulse Output Reset Input Turbine Input Location Safety
V Max 28 Vdc 5 Vdc Voc=2.5V Exxxxxx
I Max 100mA 5mA Ics=1.8mA Intrinsically Safe When
Installed Per Drawing - Class I Div 1 Groups C,D
Ci
Li
0.0µF
0.0mH
0.0µF
0.0mH
Ca=1.5µF
La=1.65H
B300020
SÈcuritÈ intrinsËque
Class I Zone 0, IIB, T4
Class II Div 1 Groups E,F,G MODEL: XXXXXXXXXX
lorsqu'il est installÈ Class III
WARNING: Substitution of Components May Impair Intrinsic par le dessin B300020
Safety
Max Ambient 70∞C
SERIAL: XXXXXXXXXX
ADVERTSSEMENT: La Substitution De Composants Peut Electrical and Hazardous
Compromettre La Securtie Intrinseque Pulse Output Reset Input Turbine Input Location Safety
1243 II 2 G Ex ib IIB T4
V Max 28 Vdc 5 Vdc Voc=2.5V Exxxxxx
I Max 100mA 5mA Ics=1.8mA Intrinsically Safe When
Class I Div 1 Groups C,D
Installed Per Drawing -
Ci 0.0µF 0.0µF Ca=1.5µF B300020 Class I Zone 0, IIB, T4
Li 0.0mH 0.0mH La=1.65H SÈcuritÈ intrinsËque Class II Div 1 Groups E,F,G
lorsqu'il est installÈ Class III
MODEL: XXXXXXXXXX
Max Ambient 70∞C
WARNING: Substitution of Components May Impair Intrinsic par le dessin B300020
Safety
ADVERTSSEMENT: La Substitution De Composants Peut
Compromettre La Securtie Intrinseque 1243 II 2 G Ex ib IIB T4 SERIAL: XXXXXXXXXX
Electrical and Hazardous
Pulse Output Reset Input Turbine Input Location Safety
V Max 28 Vdc 5 Vdc Voc=2.5V Exxxxxx
Explosion-Proof
for ease of viewing.
Remote Mount
sold separately.
included.
•
•
•
•
Trademarks appearing in this document are the property of their respective entities.
Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding
contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved.
info@blancett.com | www.blancett.com | www.badgermeter.com
Phone: 262-639-6770 | Fax: 262-417-1155
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412