SGS-CSTC Standards Technical Services Co., Ltd.

Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 1 of 47

TEST REPORT
Application No.: GZEM2401000091HS
Applicant: Breville Pty Ltd.
Address of Applicant: Ground Floor, Suite 2, 170-180 Bourke Road, Alexandria, NSW, 2015,
Auatralia

T
Manufacturer: Breville Pty Ltd.
Address of Manufacturer: Ground Floor, Suite 2, 170-180 Bourke Road, Alexandria, NSW, 2015,
Auatralia
Factory: G.E.W. China Manufacturing Co. Ltd
Address of Factory: 11 Yihuan Road,Che Ling Industrial Zone,Hou Jie Town, Dongguan
City,Guangdong Province.P.R.C.
Product Name: Breville the EyeQ Toaster
Model No.:

Trade Mark:
AF
Standard(s) :
BTA870 XXXYYY /ZZ, BTA850 XXXYYY /ZZ (where "XXX" indicate a
different colour and "YYY" indicates different country or region. Each "XXX"
or "YYY" can be "0-9, "A-Z" or "blank" will be added in the product
description. "/ZZ" indicates a different production version, and "ZZ" can be
"0-9'',"A-Z" and it is used as service code or blank.) 
Please refer to section 2 of this report which indicates which item was
actually tested and which were electrically identical.
Breville
EN IEC 55014-1: 2021
EN IEC 55014-2: 2021
EN IEC 61000-3-2: 2019+A1:2021
EN 61000-3-3: 2013+ A1:2019+A2:2021
Date of Receipt: 2024-01-03
Date of Test: 2024-01-09 to 2024-01-11
DR
Date of Issue: 2024-01-18
Test Result: Fail*
* In the configuration tested, the EUT complied with the standards specified above.

Jerry Chan
Manager
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 2 of 47

Revision Record

Version Report No. Date Remark

01 GZEM240100009101 2024-01-18 Original

T
AF
DR
Authorized for issue by:

Pank Feng/Project Engineer

Terry Lai/Reviewer
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 3 of 47

2 Test Summary
Emission Part
Item Standard Method Requirement Result
Conducted Emissions
CISPR 16-2-
at AC Mains Power Table 5 Pass
1:2014+A1:2017
Port (150kHz-30MHz)
EN IEC 55014-1:

T
Disturbance Power CISPR 16-2-2:2010 Table 7 & 8 Pass
2021
Discontinuous
Disturbance (150kHz- EN IEC 55014-1: 2021 Clause 4.4.2 Pass
30MHz)
Harmonic Current EN IEC 61000-3-2: EN IEC 61000-3-2:
Class A Pass
Emission 2019+A1:2021 2019+A1:2021
EN 61000-3-3:
Voltage Fluctuations EN 61000-3-3: 2013+
2013+ Clause 5 N/A
and Flicker A1:2019+A2:2021
A1:2019+A2:2021
AF
Immunity Part
Item
Electrostatic
Discharge
Electrical Fast
Transients Burst at
AC Mains Power Port
Surge at AC Mains
Standard Method
EN 61000-4-2:2009

EN 61000-4-4:2012

EN 61000-4-
Requirement
4kV Contact Discharge,
8kV Air Discharge
1kV, 5/50ns Tr/Td, 5kHz
Repetition Frequency
1.2/50µs Tr/Td, 1kV Line
to Line, 2kV Line to
Result
Pass

Pass

Pass
Power Port 5:2014+A1:2017
Ground
EN IEC 55014-2:
Conducted Immunity
2021
at AC Mains Power 3Vrms (emf),80%,1kHz
EN 61000-4-6: 2014 Pass
Port (150kHz- Amp. Mod.
230MHz)
For 60Hz: 0 % UT for
0.5cycle, 40 % UT for
DR
Voltage Dips and EN IEC 61000-4-11:
12cycles, 70 % UT for Pass
Interruptions 2020
30cycles, UT is Supply
Voltage
Note:
E.U.T./EUT means Equipment Under Test.
Pass means the test result passed the test standard requirement, please find the detailed decision rule
in the report relative section.

Model No.: BTA870 XXXYYY /ZZ, BTA850 XXXYYY /ZZ (where "XXX" indicate a different colour and
"YYY" indicates different country or region. Each "XXX" or "YYY" can be "0-9, "A-Z" or "blank" will be
added in the product description. "/ZZ" indicates a different production version, and "ZZ" can be "0-
9'',"A-Z" and it is used as service code or blank.)

The electrical circuit design, layout, components used and internal wiring for above models are
identical, only model name, rated power and below show the differences.
BTA870 – is the 4-slice model
BTA850 – is the 2-slice model.
Therefore only one model BTA870 was tested in this report.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 4 of 47

3 Contents
Page
1 Cover Page ................................................................................................................................................1

2 Test Summary ...........................................................................................................................................3

T
3 Contents ....................................................................................................................................................4

4 General Information ..................................................................................................................................6


4.1 Details of E.U.T. .................................................................................................................................6
4.2 Description of Support Units ..............................................................................................................6
4.3 Measurement Uncertainty ..................................................................................................................6
4.4 Test Location ......................................................................................................................................6
4.5 Test Facility ........................................................................................................................................7

6
4.6
4.7
4.8

6.1
AF Deviation from Standards ...................................................................................................................7
Abnormalities from Standard Conditions ...........................................................................................7
EMS Monitor.......................................................................................................................................7
Equipment List ..........................................................................................................................................8

Emission Test Results ...........................................................................................................................11


Conducted Emissions at AC Mains Power Port (150kHz-30MHz) ..................................................11
6.1.1 E.U.T. Operation ..........................................................................................................................11
6.1.2 Test Mode Description .................................................................................................................11
6.1.3 Test Setup Diagram .....................................................................................................................11
6.1.4 Measurement Procedure and Data.............................................................................................11
6.2 Disturbance Power ...........................................................................................................................14
6.2.1 E.U.T. Operation ..........................................................................................................................14
6.2.2 Test Mode Description .................................................................................................................14
6.2.3 Test Setup Diagram .....................................................................................................................14
DR
6.2.4 Measurement Procedure and Data.............................................................................................14
6.3 Discontinuous Disturbance (150kHz-30MHz) ..................................................................................16
6.3.1 E.U.T. Operation ..........................................................................................................................16
6.3.2 Test Mode Description .................................................................................................................16
6.3.3 Test Setup Diagram .....................................................................................................................17
6.3.4 Measurement Procedure and Data.............................................................................................17
6.4 Harmonic Current Emission .............................................................................................................18
6.4.1 E.U.T. Operation ..........................................................................................................................18
6.4.2 Test Mode Description .................................................................................................................18
6.4.3 Test Setup Diagram .....................................................................................................................18
6.4.4 Measurement Procedure and Data.............................................................................................18
6.5 Voltage Fluctuations and Flicker ......................................................................................................24
7 Immunity Test Results ...........................................................................................................................25
7.1 Electrostatic Discharge ....................................................................................................................26
7.1.1 Test Setup Diagram .....................................................................................................................26
7.1.2 E.U.T. Operation ..........................................................................................................................26
7.1.3 Test Mode Description .................................................................................................................26
7.1.4 Test Condition and Results: .........................................................................................................26
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 5 of 47
7.2 Electrical Fast Transients Burst at AC Mains Power Port ................................................................28
7.2.1 Test Setup Diagram .....................................................................................................................28
7.2.2 E.U.T. Operation ..........................................................................................................................28
7.2.3 Test Mode Description .................................................................................................................28
7.2.4 Test Condition and Results: .........................................................................................................28
7.3 Surge at AC Mains Power Port ........................................................................................................29
7.3.1 Test Setup Diagram .....................................................................................................................29
7.3.2 E.U.T. Operation ..........................................................................................................................29

T
7.3.3 Test Mode Description .................................................................................................................29
7.3.4 Test Condition and Results: .........................................................................................................29
7.4 Conducted Immunity at AC Mains Power Port (150kHz-230MHz) ..................................................31
7.4.1 Test Setup Diagram .....................................................................................................................31
7.4.2 E.U.T. Operation ..........................................................................................................................31
7.4.3 Test Mode Description .................................................................................................................31
7.4.4 Test Condition and Results: .........................................................................................................31
7.5 Voltage Dips and Interruptions .........................................................................................................32

9
AF
7.5.1 Test Setup Diagram .....................................................................................................................32
7.5.2 E.U.T. Operation ..........................................................................................................................32
7.5.3 Test Mode Description .................................................................................................................32
7.5.4 Test Condition and Results: .........................................................................................................32
Test Setup Photo ....................................................................................................................................34

EUT Constructional Details (EUT Photos) ...........................................................................................42


DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 6 of 47

4 General Information
4.1 Details of E.U.T.
Power supply: AC 120V 60Hz
Rated Power:
BTA870:1800W

T
BTA850:1200W
Test voltage: AC 120V
Clock frequency:<15MHz
Cable(s): AC mains cable:3 wires about 1.0m unshielded

4.2 Description of Support Units


AF Description Manufacturer Model No. Serial No.
-- -- -- --
The EUT has been tested as an independent unit.

4.3 Measurement Uncertainty


Test Item Measurement Uncertainty
Conducted Emissions at AC Mains Power Port (150kHz-
2.76dB (150kHz to 30MHz)
30MHz)
Disturbance Power 3.62dB(30MHz-300MHz)
Remark:
The Ulab (lab Uncertainty) is less than Ucispr (CISPR Uncertainty), so the test results
– compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
– non-compliance is deemed to occur if any measured disturbance level exceeds the disturbance
DR
limit.

4.4 Test Location


All tests were performed at:
SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory,
198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District,
Guangzhou, China 510663
Tel: +86 20 82155555 Fax: +86 20 82075059
No tests were sub-contracted.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 7 of 47

4.5 Test Facility


The test facility is recognized, certified, or accredited by the following organizations:
● ACMA
SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the
Australian/New Zealand Regulatory Compliance Mark (RCM).

T
● SGS UK(Certificate No.: 32), SGS-TUV SAARLAND and SGS-FIMKO
Have approved SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of
EMC TESTING SERVICES and SAFETY TESTING SERVICES.
● FCC Recognized Accredited Test Firm(Registration No.: 486818)
SGS-CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance
letter from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration
Number: 486818.

AF
ISED (Registration No.: 4620B, CAB identifier: CN0052)
SGS-CSTC Standards Technical Services Co., Ltd., has been registered by Innovation Science and
Economic Development Canada for Wireless Device Testing laboratories to test to Canadian radio
equipment requirements. Registration No. 4620B, CAB identifier: CN0052.
● VCCI (Registration No.: R-12460, C-12584, G-20107 and T-11179)
The 10m Semi-anechoic chamber, 966 Anechoic Chamber and Shielded Room of SGS-CSTC
Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for
Voluntary Control Measures with Registration No.: R-12460, C-12584, G-20107 and T-11179
respectively.
● CBTL (Lab Code: TL129)
SGS-CSTC Standards Technical Services Co., Ltd., E&E Laboratory has been assessed and fully
comply with the requirements of ISO/IEC 17025:2017, the Basic Rules, IECEE 01 and Rules of
procedure IECEE 02, and the relevant IECEE CB-Scheme Operational documents.
DR
4.6 Deviation from Standards
None

4.7 Abnormalities from Standard Conditions


None

4.8 EMS Monitor


Visual: motor running
Other: heating
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 8 of 47

5 Equipment List
Conducted Emissions at AC Mains Power Port (150kHz-30MHz)
Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
Coaxial Cable HangTianXing 2m EMC0107 2023-08-04 2024-08-03
8m x 3m x
Shielding Room ChangZhou ZhongYu EMC0306 2022-10-16 2025-10-15

T
3.8m
Two-Line V-Network-GZ Rohde & Schwarz ENV216 EMC2135 2023-09-08 2024-09-07
EMI Test Receiver
Rohde & Schwarz ESR3 EMC2221 2023-05-19 2024-05-18
(9kHz-3.6GHz)
Test Software E3r Audix Ver.6.11812 GZE100-77 N/A N/A
Artificial Mains Network
AFJ Instruments LT32C EMC2046 2023-10-20 2024-10-19
(LISN)
AF
Disturbance Power
Equipment

Shielding Room

EMI Test Receiver


(9kHz-3.6GHz)
Test Software E3r
Manufacturer

ChangZhou ZhongYu

Rohde & Schwarz

Audix
Model No.
8m x 3m x
3.8m

ESR3

Ver.6.11812
Inventory No.

EMC0306

EMC2221

GZE100-77
Cal Date

2022-10-16

2023-05-19

N/A
Cal Due Date

2025-10-15

2024-05-18

N/A
Slide Bar RP (KMS560) HD-GmbH KMS560 EMC0103 N/A N/A
Slide Bar Controller
HD-GmbH HD50 EMC0305 N/A N/A
(HD50)
Beijing Dazhe Co.
Absorbing Clamp-AUX ZN23201 EMC2040 2023-12-04 2024-12-03
Ltd.
Absorbing Clamp-Main Rohde & Schwarz MDS-21 EMC2184 2023-02-20 2024-02-19
DR
6 dB Attenuator with 8m
Rohde & Schwarz MDS-21 EMC2185 2023-02-20 2024-02-19
length cable

Discontinuous Disturbance (150kHz-30MHz)


Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
Click Analyzer (PMM Narda Safety Test
PMM CA0010 EMC2182 2023-09-08 2024-09-07
CA0010) Solutions
EMI Receiver (10Hz- Narda Safety Test
PMM 9010F EMC2183 2023-09-08 2024-09-07
30MHz) Solutions
Test Software PMM Narda Safety Test
Ver 1.06 GZE100-76 N/A N/A
Click Analysis Solutions
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 9 of 47

Harmonic Current Emission


Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
Digital power analyzer
for harmonics & flicker EMTEST DPA 500N EMC2235 2023-04-21 2024-04-20
testing
Programmable

T
NETWAVE 7-
multifunctional ac/dc EMTEST EMC2234 2023-04-21 2024-04-20
400
power source
NET.Control EMTEST Ver 3.2.3 GZE100-80 N/A N/A

Electrostatic Discharge
Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
ESD Ground Plane SGS-EMC 3m x 3m EMC0804 N/A N/A
AF
Aneroid Barometer

ESD Simulator-E

Equipment
Shanghai
Meteorological
Instrument Factory
Co., Ltd.
EMTEST

Manufacturer
YM3

NX30

Electrical Fast Transients Burst at AC Mains Power Port


Model No.
EMC2181

EMC2186

Inventory No.
2023-11-08

2023-02-20

Cal Date
2024-11-07

2024-02-19

Cal Due Date


Oscilloscope Tektronix TDS3052C EMC2055 2023-11-10 2024-11-09
NSG
EMC Immunity Test 3060&CDN306
TESEQ AG EMC2072 2023-12-15 2024-12-14
System 1&INA 6502
CIB
Test Software WIN 3000 TESEQ AG Ver 1.3.2 GZE100-68 N/A N/A
DR
Surge at AC Mains Power Port
Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
Oscilloscope Tektronix TDS3052C EMC2055 2023-11-10 2024-11-09
NSG
EMC Immunity Test 3060&CDN306
TESEQ AG EMC2072 2023-12-15 2024-12-14
System 1&INA 6502
CIB
Test Software WIN 3000 TESEQ AG Ver 1.3.2 GZE100-68 N/A N/A

Conducted Immunity at AC Mains Power Port (150kHz-230MHz)


Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
Dual Directional coupler Werlatone Inc. C1795 EMC1105 2023-05-15 2024-05-14
CDN M2 Schaffner Chase CDN-M2-16 EMC1107 2023-10-20 2025-10-19
Elektronik-
CDN M2/M3 L-801:M2/M3 EMC2048 2023-07-18 2024-07-17
Feinmechanik
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 10 of 47
Test System for
Conducted and Radiated TESEQ AG NSG 4070B-80 EMC2115 2023-11-10 2024-11-09
Immunity
Audio Analyzer Keysight U8903B EMC2180 2023-08-30 2024-08-29
Test Software
TESEQ AG Ver.1.3.0.1 GZE100-72 N/A N/A
NSG4070_Ctrl1
Oscilloscope Tektronix TDS3052C EMC2055 2023-11-10 2024-11-09

T
Voltage Dips and Interruptions
Equipment Manufacturer Model No. Inventory No. Cal Date Cal Due Date
Oscilloscope Tektronix TDS3052C EMC2055 2023-11-10 2024-11-09
NSG
EMC Immunity Test 3060&CDN306
TESEQ AG EMC2072 2023-12-15 2024-12-14
System 1&INA 6502
AF
Test Software WIN 3000

General used equipment


Equipment
DMM
DMM
TESEQ AG

Manufacturer
Fluke
Fluke
CIB
Ver 1.3.2

Model No
73
73
GZE100-68

Inventory No
EMC0006
EMC0007
N/A

Cal Date
2023-06-11
2023-06-11
N/A

Cal Due Date


2024-06-10
2024-06-10
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 11 of 47

6 Emission Test Results

6.1 Conducted Emissions at AC Mains Power Port (150kHz-30MHz)


Test Requirement: EN IEC 55014-1: 2021
Test Method: CISPR 16-2-1:2014+A1:2017

T
Limit:
0.15M-0.5MHz 66dB(μV)-56dB(μV) quasi-peak, 59dB(μV)-46dB(μV) average
0.5M-5MHz 56dB(μV) quasi-peak, 46dB(μV) average
5M-30MHz 60dB(μV) quasi-peak, 50dB(μV) average
Detector: Peak for pre-scan (9kHz resolution bandwidth) 0.15M to 30MHz

6.1.1 E.U.T. Operation


AF
Operating Environment:
Temperature: 22.7 C Humidity: 55.6 % RH Atmospheric Pressure: 1021 mbar

6.1.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.

6.1.3 Test Setup Diagram


DR

6.1.4 Measurement Procedure and Data


Frequency Range: 150kHz to 30MHz
An initial pre-scan was performed with peak detector.Quasi-Peak or Average measurement were
performed at the frequencies with maximized peak emission were detected.The red line show in
graphic is the limit in standard used in this section.
Measured Level = Read level + Cable Loss + LISN Factor
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 12 of 47

Test Mode: 00; Line: Live line

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 13 of 47

Test Mode: 00; Line: Neutral Line

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 14 of 47

6.2 Disturbance Power


Test Requirement: EN IEC 55014-1: 2021
Test Method: CISPR 16-2-2:2010
Limit:
30MHz- 300MHz: 45dB(pW)-55dB(pW) quasi-peak, 35dB(pW)-45dB(pW) average

T
200MHz- 300MHz: 0dB(pW)-10dB(pW) quasi-peak (reduction limit)
Detector: Peak for pre-scan (120kHz resolution bandwidth) 30MHz to 300MHz

6.2.1 E.U.T. Operation


Operating Environment:
Temperature: 22.7 C Humidity: 55.6 % RH Atmospheric Pressure: 1021 mbar

6.2.2 Test Mode Description


AF
Pre-scan / Mode
Final test Code
Final test 00

6.2.3 Test Setup Diagram


Description

Test the EUT in normal working mode,with heating and motor running.
DR
6.2.4 Measurement Procedure and Data
Frequency Range: 30MHz to 300MHz
An initial pre-scan was performed with peak detector.Quasi-Peak or Average measurement were
performed at the frequencies with maximized peak emission were detected.The red line show in
graphic is the limit in standard used in this section.
Measured Level = Read level + Cable Loss + Clamp Factor
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 15 of 47

Test Mode: 00

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 16 of 47

6.3 Discontinuous Disturbance (150kHz-30MHz)


Test Requirement: EN IEC 55014-1: 2021
Test Method: EN IEC 55014-1: 2021
Limit:
Provision Click Rate (N)

T
1 All clicks ≤ 20 ms 90 % click ≤ 10 ms N≤5
2 N < 0,2 Lq b= La + 44 Clicks ≤ 25% exceed Lq b
c

3 30 > N ≥ 0,2 Lq b= La + 20 lg(30/N) Clicks c ≤ 25% exceed Lq b


a The limits L of Conducted Emissions apply also to discontinuous disturbances from all equipment
which produce:
1) disturbances other than clicks, or
2) clicks with a click rate N equal to or greater than 30
b AF
The click limit Lq is calculated by increasing the relevant quasi-peak limit L for continuous
disturbances by certain value.
The click limit applies to the disturbance assessed according to the upper quartile method
c a quarter of the number of the clicks registered during the observation time T is allowed to

exceed the click limit Lq

6.3.1 E.U.T. Operation


Operating Environment:
Temperature: 22.1 C Humidity: 52.4 % RH Atmospheric Pressure: 1021 mbar

6.3.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 17 of 47

6.3.3 Test Setup Diagram

T
AF
6.3.4 Measurement Procedure and Data
Frequency Range: 150kHz to 30MHz

Test Mode: 00
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 18 of 47

6.4 Harmonic Current Emission


Test Requirement: EN IEC 61000-3-2: 2019+A1:2021
Test Method: EN IEC 61000-3-2: 2019+A1:2021

6.4.1 E.U.T. Operation


Operating Environment:

T
Temperature: 22.1 C Humidity: 52.3 % RH Atmospheric Pressure: 1021 mbar

6.4.2 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.

6.4.3 Test Setup Diagram


AF
DR
6.4.4 Measurement Procedure and Data
Frequency Range: 100Hz to 2kHz
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 19 of 47

Test Mode: 00

Standard Specific Results for IEC 61000-3-2 (Edition 5.1)

Standard Group: Industry

T
Standard Name: IEC 61000-3-2 (Edition 5.1)

Limits for harmonic current emissions (equipment input current < 16 A per phase)

Device Under Test: PASS

Power Source: PASS

Connection Type: L-N

Main Line:AF
Classification:

Appli. of Limits:

Test Duration:
120 V, 60 Hz

Class A

less than or equal to 150 % (Without POHC Enhancement)

2 min 30 s

Check Harmonics 2..40


First detected harmonic order > 150 %
Line 1: None
Harmonics orders > 150 %
Line 1: None
Harmonics orders with average > 100 %
DR
Line 1: None

Measured values
Fundamental Current
Line 1: 12.845 A
Active input Power
Line 1: 1532.247 W *
Circuit power factor
Line 1: 1*
* Absolute value.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 20 of 47
Current Test Result
Average and Maximum harmonic current results
Hn Average Maximum Harmonic
of Limit Limit of Limit Limit Result
Ieff [A] Result Ieff [A] Result
[%] [A] [%] [A]
1 11.511 12.845
2 0.667 61.718 1.080 PASS 0.748 46.151 1.620 PASS PASS

T
3 0.034 1.462 2.300 n/a 0.044 1.268 3.450 n/a PASS
4 0.138 32.019 0.430 PASS 0.154 23.869 0.645 PASS PASS
5 0.019 1.650 1.140 n/a 0.029 1.702 1.710 n/a PASS
6 0.056 18.574 0.300 n/a 0.063 13.928 0.450 n/a PASS
7 0.023 3.052 0.770 n/a 0.026 2.269 1.155 n/a PASS
8 0.032 14.106 0.230 n/a 0.038 11.152 0.345 n/a PASS
9 0.014 3.472 0.400 n/a 0.019 3.090 0.600 n/a PASS
10 0.020 10.993 0.184 n/a 0.023 8.350 0.276 n/a PASS
11
12
13
14
15
16
17
18
19
AF 0.012
0.013
0.007
0.011
0.004
0.007
0.002
0.007
0.001
3.691
8.697
3.162
8.536
2.818
6.344
1.809
6.654
1.032
0.330
0.153
0.210
0.131
0.150
0.115
0.132
0.102
0.118
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.015
0.017
0.010
0.013
0.008
0.009
0.005
0.009
0.004
2.978
7.272
3.281
6.677
3.479
5.394
2.532
5.832
2.204
0.495
0.230
0.315
0.197
0.225
0.173
0.199
0.153
0.178
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
20 0.005 5.711 0.092 n/a 0.006 4.562 0.138 n/a PASS
21 0.003 2.595 0.107 n/a 0.005 2.849 0.161 n/a PASS
22 0.004 4.760 0.084 n/a 0.006 4.983 0.125 n/a PASS
23 0.003 2.852 0.098 n/a 0.004 2.785 0.147 n/a PASS
24 0.004 4.958 0.077 n/a 0.005 4.308 0.115 n/a PASS
25 0.002 2.519 0.090 n/a 0.004 3.066 0.135 n/a PASS
26 0.003 4.062 0.071 n/a 0.004 4.068 0.106 n/a PASS
DR
27 0.001 1.459 0.083 n/a 0.003 2.472 0.125 n/a PASS
28 0.003 4.263 0.066 n/a 0.004 4.210 0.099 n/a PASS
29 0.001 1.238 0.078 n/a 0.003 2.329 0.116 n/a PASS
30 0.002 4.033 0.061 n/a 0.003 3.617 0.092 n/a PASS
31 0.001 1.515 0.073 n/a 0.003 2.458 0.109 n/a PASS
32 0.002 3.388 0.058 n/a 0.003 3.976 0.086 n/a PASS
33 0.001 2.046 0.068 n/a 0.003 2.480 0.102 n/a PASS
34 0.002 3.864 0.054 n/a 0.003 3.713 0.081 n/a PASS
35 0.001 1.851 0.064 n/a 0.002 2.545 0.096 n/a PASS
36 0.002 3.136 0.051 n/a 0.003 3.573 0.077 n/a PASS
37 0.002 2.646 0.061 n/a 0.003 3.010 0.091 n/a PASS
38 0.002 3.225 0.048 n/a 0.003 3.638 0.073 n/a PASS
39 0.001 1.561 0.058 n/a 0.002 2.414 0.087 n/a PASS
40 0.002 3.465 0.046 n/a 0.002 3.339 0.069 n/a PASS
Note: Harmonic currents less than 0.6 % of the input current measured under the test conditions, or less than 5 mA,
whichever is greater, are disregarded.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 21 of 47

Time Window 1

Time Domain of Time Window 1

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 22 of 47

Maximum / Average Values

Line 1

Maximum Values
Frequency 60 Hz

T
Voltage RMS 119.5 V
Current RMS 12.87 A

Peak Current 18.08 A


Fundamental Current 12.86 A

Current Crest Factor 2.052

Active Power P 1.534e+3 W


AF
Average Values
Power Factor

Total Harmonic Current (THC)


Instantaneous Partial Odd Harmonic Current (Inst. POHC)

Total Harmonic Distortion Current (THDC)

Total Harmonic Current (THC)


Instantaneous Partial Odd Harmonic Current (Inst. POHC)
1.000

0.7682 A
0.05272 A

0.05981

0.6880 A
5.637e-3 A

Total Harmonic Distortion Current (THDC) 0.05356


DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 23 of 47

Average Harmonics

Average Harmonics (Line 1)

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 24 of 47

6.5 Voltage Fluctuations and Flicker


Test Requirement: EN 61000-3-3: 2013+ A1:2019+A2:2021
Test Method: EN 61000-3-3: 2013+ A1:2019+A2:2021
There is no need for Flicker test to be performed on this product in accordance with EN 61000-3-3. For
further details, please refer to Clause 1 of EN 61000-3-3 which states:
This part of EN 61000 is applicable to electrical and electronic equipment having an input current equal to or

T
less than 16 A per phase, intended to be connected to public low-voltage distribution systems of between 220
V and 250 V line to neutral at 50 Hz, and not subject to conditional connection.

AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 25 of 47

7 Immunity Test Results

Performance Criteria Description


Criterion A: The apparatus shall continue to operate as intended during the test. No
degradation of performance or loss of function is allowed below a performance

T
level (or permissible loss of performance) specified by the manufacturer, when the
apparatus is used as intended. If the minimum performance level or the permissible
performance loss is not specified by the manufacturer, then either of these may be
derived from the product description and documentation, and from what the user
may reasonably expect from the apparatus if used as intended.
Criterion B: The apparatus shall continue to operate as intended after the test. No degradation
of performance or loss of function is allowed below a performance level (or
permissible loss of performance) specified by the manufacturer, when the
AF
Criterion C:
apparatus is used as intended. During the test, degradation of performance is
allowed, however. No change of actual operating state or stored data is allowed. If
the minimum performance level or the permissible performance loss is not
specified by the manufacturer, then either of these may be derived from the
product description and documentation and from what the user may reasonably
expect from the apparatus if used as intended.
Temporary loss of function is allowed, provided the function is self recoverable or
can be restored by the operation of the controls, or by any operation specified in
the instructions for use.
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 26 of 47

7.1 Electrostatic Discharge


Test Requirement: EN IEC 55014-2: 2021
Test Method: EN 61000-4-2:2009

7.1.1 Test Setup Diagram

T
AF
7.1.2 E.U.T. Operation
Operating Environment:
Temperature: 22.1 C Humidity: 52.4 % RH Atmospheric Pressure: 1021 mbar

7.1.3 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.
Final test 01 Test the EUT in idle mode.
DR
7.1.4 Test Condition and Results:
Performance Criterion: B
Discharge Impedance: 330 Ω / 150 pF
Discharge Voltage: Air Discharge: 8 kV; Contact Discharge:4 kV; VCP/HCP: 4 kV.
Polarity: Positive & Negative
Number of Discharge: Minimum 10 times at each test point
Discharge Mode: Single Discharge
Discharge Period: 1 second minimum
Test Point 1: All insulated enclosure & seams.
Test Point 2: All accessible metal parts of the enclosure.
Test Point 3: All sides.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 27 of 47

Result /
Discharge type Level (kV) Polarity Test Point
Observations
Air Discharge 8 + 1 A
Air Discharge 8 - 1 A
Contact Discharge 4 + 2 A
Contact Discharge 4 - 2 A

T
Horizontal Coupling 4 + 3 A
Horizontal Coupling 4 - 3 A
Vertical Coupling 4 + 3 A
Vertical Coupling 4 - 3 A
A: No degradation in the performance of the EUT was observed

AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 28 of 47

7.2 Electrical Fast Transients Burst at AC Mains Power Port


Test Requirement: EN IEC 55014-2: 2021
Test Method: EN 61000-4-4:2012

7.2.1 Test Setup Diagram

T
AF
7.2.2 E.U.T. Operation
Operating Environment:
Temperature: 21.7 C Humidity: 57.8 % RH Atmospheric Pressure: 1021 mbar

7.2.3 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.
Final test 01 Test the EUT in idle mode.
DR
7.2.4 Test Condition and Results:
Performance Criterion: B
Repetition Frequency: 5kHz
Burst Period: 300ms
Test Duration: 2 minute per level & polarity
Test Level: 1.0kV
Polarity: Positive & Negative

Repetition Result /
Port Level (kV) Polarity CDN/Clamp
Frequency: Observations
AC power port 1 + 5kHz CDN A
AC power port 1 - 5kHz CDN A
A: No degradation in the performance of the EUT was observed
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 29 of 47

7.3 Surge at AC Mains Power Port


Test Requirement: EN IEC 55014-2: 2021
Test Method: EN 61000-4-5:2014+A1:2017

7.3.1 Test Setup Diagram

T
AF
7.3.2 E.U.T. Operation
Operating Environment:
Temperature: 21.7 C Humidity: 57.8 % RH Atmospheric Pressure: 1021 mbar

7.3.3 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.
Final test 01 Test the EUT in idle mode.
DR
7.3.4 Test Condition and Results:
Performance Criterion: B
Interval: 60s between each surge
Test Level: ±1kV Live to Neutral; ±2kV Live, Neutral to Earth
Polarity: Positive & Negative
Generator source impedance: 2Ω
CDN coupling impedance(Line-to-ground):10Ω
Trigger Mode: Internal
No. of surges: 5 positive at 90°, 5 negative at 270°.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 30 of 47

Result /
Test Line Level (kV) Polarity Phase (deg)
Observations
L-N 1 + 90° A
L-N 1 - 270° A
L-PE 2 + 90° A
L-PE 2 - 270° A

T
N-PE 2 + 90° A
N-PE 2 - 270° A
A: No degradation in the performance of the EUT was observed

AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 31 of 47

7.4 Conducted Immunity at AC Mains Power Port (150kHz-230MHz)


Test Requirement: EN IEC 55014-2: 2021
Test Method: EN 61000-4-6: 2014

7.4.1 Test Setup Diagram

T
AF
7.4.2 E.U.T. Operation
Operating Environment:
Temperature: 21.7 C Humidity: 57.8 % RH Atmospheric Pressure: 1021 mbar

7.4.3 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.
Final test 01 Test the EUT in idle mode.
DR
7.4.4 Test Condition and Results:
Performance Criterion: A
Step Size: 1%
Frequency Range: 0.15MHz to 230MHz
Modulation: 80%, 1kHz Amplitude Modulation

Result /
Cable Port Level (Vrms) CDN/Clamp Dwell time
Observations
AC power port 3 CDN 2s A
A: No degradation in the performance of the EUT was observed
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 32 of 47

7.5 Voltage Dips and Interruptions


Test Requirement: EN IEC 55014-2: 2021
Test Method: EN IEC 61000-4-11: 2020

7.5.1 Test Setup Diagram

T
AF
7.5.2 E.U.T. Operation
Operating Environment:
Temperature: 21.7 C Humidity: 57.8 % RH Atmospheric Pressure: 1021 mbar

7.5.3 Test Mode Description


Pre-scan / Mode
Description
Final test Code
Final test 00 Test the EUT in normal working mode,with heating and motor running.
Final test 01 Test the EUT in idle mode.
DR
7.5.4 Test Condition and Results:
Performance Criterion:
For 50Hz: 0% of UT (Rated Voltage) for 0.5 Cycle: C; 40% of UT for 10 Cycles: C; 70% of UT for 25
Cycles: C.
For 60Hz: 0% of UT (Rated Voltage) for 0.5 Cycle: C; 40% of UT for 12 Cycles: C; 70% of UT for 30
Cycles: C.

No. of Dips / Interruptions: 3 per Level


Time between dropout: 10s
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 33 of 47

No. of Dips / Result /


Level % UT Phase (deg) Duration
Interruptions Observations
0 0° 0.5 Cycle for 60Hz 3 A
0 180° 0.5 Cycle for 60Hz 3 A
40 0° 12 Cycles for 60Hz 3 A
40 180° 12 Cycles for 60Hz 3 A

T
70 0° 30 Cycles for 60Hz 3 A
70 180° 30 Cycles for 60Hz 3 A
A: No degradation in the performance of the EUT was observed

AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 34 of 47

8 Test Setup Photo


Conducted Emissions at AC Mains Power Port (150kHz-30MHz)

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 35 of 47

Disturbance Power

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 36 of 47

Discontinuous Disturbance (150kHz-30MHz)

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 37 of 47

Harmonic Current Emission

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 38 of 47

Voltage Fluctuations and Flicker

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 39 of 47

Electrostatic Discharge

T
AF
Electrical Fast Transients Burst at AC Mains Power Port
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 40 of 47

Surge at AC Mains Power Port

T
AF
Conducted Immunity at AC Mains Power Port (150kHz-230MHz)
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 41 of 47

Voltage Dips and Interruptions

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 42 of 47

9 EUT Constructional Details (EUT Photos)

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 43 of 47

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 44 of 47

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 45 of 47

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 46 of 47

T
AF
DR
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
EMC-TRF-01 Rev 1.1 Report No.: GZEM240100009101
Page: 47 of 47

T
AF
DR

- End of the Report -