Hydraulic Calculations
For bottom most gate
1. Calculation for the floor level of Intakewell: 285.58 NSL
(a) Minimum water level in the reservoir(NSL) = 285.58 m
(b) Invert level of bottom most inlet gate = 284.58 m
(c) Depth of water required for impeller = 1 m
(d) Extra depth required for silt = 0.5 m
(e) Floor level = 283.08 m
Floor level provided = 283 m
Hence Safe
300
2. Calculation for Inlet gate of intake well:
(a) Flow required for 22 Ha CCA for anticipated = 10 lps 285.58 m
future expension
(b) Minimum water level in the reservoir = 285.58 m
(c) Invert level of bottom most inlet gate = 284.58 m 0.9 m
(d) Depth of gate provided = 0.1 m 284.68 m
(e) Width of gate provided = 0.1 m
(f) Elevation of top of gate = 284.68 m
(g) Head over the pipe at top of pipe = 0.9 m 0.1
(h) Velocity = (2gh)^0.5 = 4.202142311 m/s m
(i) Area of Gate provided = 0.01 sqm 284.58 m
(j) Discharge of Pipe (Q) = 42.02142311 lps 0.1 m
> 10
Hence Ok
Hydraulic Calculations
For top most gate
1. Calculation for inlet gate of intake well:
(a) Water level in the reservoir = 270 m
(b) Invert level of top most inlet gate = 269 m
(c) Depth of water required for impeller = 1 m
(d) Extra depth required for silt = 0.5 m
(e) Floor level = 267.5 m
Floor level provided 283 m
Not safe
Since the main steel required by the wall is equal to the steel required by hoop tension. Therefore steel is provided by the
min steel criteria till pump house floor RL 285.00 i.e. 16 mm 160 c/c