EPSON WF-6090, WF-6530, WF-6590 Series Service Manual Page 101-120
EPSON WF-6090, WF-6530, WF-6590 Series Service Manual Page 101-120
EPSON WF-6090, WF-6530, WF-6590 Series Service Manual Page 101-120
WF-6590 Series
Set the Ferrite Core on the position shown below.
1). Remove the Upper Housing Assy. (P.78)
2). Remove the Panel Housing Front. (P.79)
3). Remove the Panel Assy. (P.80) Image after installation
4). Remove the Panel Lower Front Cover. (P.81)
5). Remove the Right Upper Front Cover. (P.82) Ferrite Core
6). Remove the Stacker Assy. (P.77) CSIC Board Cover
7). Remove the Cassette Assy. (P.203)
8). Remove the Front Cover Microswitch. (P.82)
9). Remove the Front Housing. (P.84)
10). Remove the Middle Housing. (P.86)
2. Disconnect the FFC from the connector of the CSIC Board. 4. Disconnect the FFC from the four connectors of the CSIC Board.
3. Disengage the six hooks, and CSIC Board Cover. 5. Remove the four screws (S11), and remove the CSIC Board.
Hooks
CSIC Board Cover
Hooks Connector
FFC
FFC
Connector
Connector
Hook
S11
Figure 2-91. Removing the CSIC Board Cover Figure 2-92. Removing the CSIC Board
For the screw types, see "2.1.2 Screw types used in the printer (p40)". Connector
1. Remove the following parts.
WF-6590/WF-6530 Series
1). Remove the Panel Assy. (P.66)
2). Remove the Paper Support Support. (P.62)
3). Remove the Left ADF Hinge Cover. (P.63)
4). Remove the Right ADF Hinge Cover. (P.64) Cable
5). Remove the ADF/Scanner Unit. (P.181)
6). Remove the Panel Lower Front Cover. (P.68)
7). Remove the Right Upper Front Cover. (P.69)
Clamp
8). Remove the Stacker Assy. (P.62)
9). Remove the Cassette Assy. (P.203) Figure 2-93. Remove the Power Supply unit (1)
10). Remove the Front Cover Microswitch. (P.69)
11). Remove the Front Housing. (P.70)
12). Remove the Middle Housing. (P.73)
5. Remove the three screws (S32), and remove the Power Supply Unit.
Engage the two ribs with the two positioning holes on the Power
Supply Unit (refer to Figure 2-94).
Ribs
Carry out the adjustments referring to "3.1 Required
Adjustments" (p224) when the Power Supply Unit is replaced.
S32
Connector
Cable
Clamp
S32
Figure 2-94. Removing the Power Supply Unit (2)
2.3.7 Carriage Mechanism/ Ink System Mechanism 1. Remove the following parts.
WF-6590/WF-6530 Series
2.3.7.1 Print Head
1). Remove the Panel Assy. (P.66)
2). Remove the Paper Support Support. (P.62)
3). Remove the Left ADF Hinge Cover. (P.63)
4). Remove the Right ADF Hinge Cover. (P.64)
5). Remove the ADF/Scanner Unit. (P.181)
6). Remove the Panel Lower Front Cover. (P.68)
7). Remove the Right Upper Front Cover. (P.69)
8). Remove the Stacker Assy. (P.62)
9). Remove the Cassette Assy. (P.203)
10). Remove the Front Cover Microswitch. (P.69)
11). Remove the Front Housing. (P.70)
12). Remove the Middle Housing. (P.73)
WF-6590 Series
1). Remove the Upper Housing Assy. (P.78)
2). Remove the Panel Housing Front. (P.79)
3). Remove the Panel Assy. (P.80)
4). Remove the Panel Lower Front Cover. (P.81)
For the screw types, see "2.1.2 Screw types used in the printer (p40)".
5). Remove the Right Upper Front Cover. (P.82)
6). Remove the Stacker Assy. (P.77)
If Printer can not perform Ink Flushing by fatal error, refer to 7). Remove the Cassette Assy. (P.203)
repair procedure of "2.3.7.19 Print Head / Ink Supply Unit (When 8). Remove the Front Cover Microswitch. (P.82)
the Printer cannot perform the Ink Flushing by fatal error)"
9). Remove the Front Housing. (P.84)
(p152).
10). Remove the Middle Housing. (P.86)
2. Install the Ink cartridge.
3. Install the following parts by the following procedure. 4. Turn the printer on.
(start the WF-6590/WF-6530 Series in the” Maintenance SP Mode” (P.249).)
3-1. Install the Panel Assy.(p.66, p.80)
3-2. Install the Front Cover Microswitch. (p.69, p.82) 5. Select the “Ink flushing” on the adjustment program.
3-3. Wrap the Front Cover Microswitch with tape to disable their sensor function. 6. Click the [Perform], and execute the Ink flushing.
7. Remove the AC Cable from the Power Supply Unit. 8. Move the CR Unit to the hole position for access to the screws.
CR Unit
CR Unit
Connector
FFC
10. Remove the four screws (S23: 3pcs, S30: 1pcs), and remove the Printhead.
When disconnecting the Head FFC, make sure to pull them
straight off one by one from their connector terminals.
Ink Tube 12. Remove the two screws (S2), and remove the Ink Tube.
S23
S30
Figure 2-100. Removing the Printhead (3)
11. Disconnect the four Head FFC from the connectors of the Print Head. S2
Head FFC
Performing the Reassembly, Adjustment and Inspection according 5. Install the Leakage check PET Chip.
to the following procedure, after removing the Print head.
kind of the Leakage Check PET Chip.
Make sure to wipe out the ink on the ink tube due to 10mm
influence on the ink leakage check result. LEAK 1684354 Put it to Rear
TESTER side
SHEET
REAR
Wiping area
15mm
90°
5-1. Set the PET Chip (x2) at the Ink Tube connected position of 6. Secure the three screws (S2: 2pcs, S30: 1pcs), and fix the
Print head. Ink tube.
Take care that the PET Chip is different between the Make sure to use the new Printhead Seal.
PET Chip for rear side and the PET Chip for front (ASP Single Part)
side in length. Make sure to check the Printhead Seal is completely
Set the PET Chip with contacting the smoked face of inserted.
the PET Chip. Make sure to check the foreign material is not
adhering to the Printhread seal.
Rear side Do not install the Printerhead Seal doubly.
LEAK TESTER SHEET REAR
Printhead Seal
15mm
The Smoked face of
two pet chips are put
toward the upside.
10mm
7. Move the CR Unit to the Home position.
Figure 2-104. Setting position of the Leakage Check PET Chip (1)
5-2. Install the Ink Tube to Print head.
Perform the Adjustment in the following procedure when you 2.3.7.2 CR Waste Ink Pad
detach/exchange the Print head.
If you check the Ink Leak by using the the Ink Leak
Measurement jig, perform it after Mechanism
Adjustment.
(Perform it between procedure 1 and procedure 2)
S23
S30
4. At the home side, remove the CR Scale from the hook of the frame. 6. Turn the CR Scale 90 degrees upward at the full side and disengage it from the
hook on the frame.
Hook
Hook
Figure 2-109. Removing the CR Scale (2) Figure 2-111. Removing the CR Scale (4)
5. Pull out the CR Scale from the slit of the CR Unit.
When installing the CR Scale, make sure to install it by reverse
procedure of the disassembly.
Side view
CR Unit
Slit
Sensor Cover
For the screw types, see "2.1.2 Screw types used in the printer (p40)". 5. Remove the three FFC clamps, and remove the Head FFC Assy from Frame.
1. Remove the following parts.
Head FFC
WF-6590/WF-6530 Series
Frame Assy
1). Remove the Panel Assy. (P.66)
2). Remove the Paper Support Support. (P.62)
3). Remove the Left ADF Hinge Cover. (P.63)
4). Remove the Right ADF Hinge Cover. (P.64)
5). Remove the ADF/Scanner Unit. (P.181)
6). Remove the Panel Lower Front Cover. (P.68)
7). Remove the Right Upper Front Cover. (P.69)
FFC clamp
8). Remove the Stacker Assy. (P.62)
9). Remove the Cassette Assy. (P.203)
10). Remove the Front Cover Microswitch. (P.69)
11). Remove the Front Housing. (P.70)
12). Remove the Middle Housing. (P.73) Figure 2-113. Removing the Head FFC (1)
6. Release the Upper Supply Tube Holder Clamp and three Tube Clamps. 10. Release the Tube Clamp.
Tube Clamp
Tube Clamp
Figure 2-114. Removing the Head FFC (2) Figure 2-115. Removing the Head FFC (3)
7. Disconnect the FFC from the connector of the CR Encoder Sensor. 11. Slide the Head FFC Assy in the direction of the arrow, and remove the Head FFC
Assy from the Printhead.
8. Remove the four screws (S23:3pcs, S30:1pcs), and remove the Printhead.(P.111)
Don’t remove the Ink Tube when the print head is removed.
9. Disconnect the four Head FFC from the connector of the Printhead.
12. Disengage the hook, slide the Upper Supply Tube Holder in the direction of the 2.3.7.6 CR Motor
arrow, and remove the Head FFC Assy from the Frame.
Frame
Hook
For the screw types, see "2.1.2 Screw types used in the printer (p40)".
1. Remove the following parts.
WF-6590/WF-6530 Series
Figure 2-117. Removing the head FFC (5)
1). Remove the Panel Assy. (P.66)
13. Remove the Head FFC Assy from the Upper Supply tube Holder. 2). Remove the Paper Support Support. (P.62)
14. Remove the Support Part from the Head FFC Assy. 3). Remove the Left ADF Hinge Cover. (P.63)
4). Remove the Right ADF Hinge Cover. (P.64)
5). Remove the ADF/Scanner Unit. (P.181)
6). Remove the Panel Lower Front Cover. (P.68)
7). Remove the Right Upper Front Cover. (P.69)
8). Remove the Stacker Assy. (P.62)
9). Remove the Cassette Assy. (P.203)
10). Remove the Front Cover Microswitch. (P.69)
11). Remove the Front Housing. (P.70)
12). Remove the Middle Housing. (P.73)
WF-6590 Series 8. Disengage the Extension Spring on the CR Driven Pulley Assy from the hook and
1). Remove the Upper Housing Assy. (P.78) release the tension of the CR Timing Belt.
2). Remove the Panel Housing Front. (P.79)
3). Remove the Panel Assy. (P.80)
4). Remove the Panel Lower Front Cover. (P.81) CR Driven Pulley Assy
5). Remove the Right Upper Front Cover. (P.82)
Hook
6). Remove the Stacker Assy. (P.77)
7). Remove the Cassette Assy. (P.203)
8). Remove the Front Cover Microswitch. (P.82)
9). Remove the Front Housing. (P.84)
10). Remove the Middle Housing. (P.86)
2. Remove the APG Gear Assy. (P.129) Extension Spring
3. Remove the USB Connector Assy. (P.95) Figure 2-118. Removing the CR Driven Pulley Assy
4. Remove the USB/FAX Cover. (P.94) 9. Remove the CR Timing Belt from the pinion gear of the CR Motor.
5. Remove the Main Board Shield Plate and Cable Holder. (refer to "Main Board 10. Remove the two screws (S27), and remove the CR Motor.
Unit" (p96))
6. Disconnect the CR Motor Cable from the connector of the Main Board. (refer to Pinion gear
"Main Board Unit" (p96)) CR Timing Belt
7. Slide the Ink Supply Unit. (refer to "Ink Supply Unit" (p135))
S27
Figure 2-119. Removing the CR Motor
For the screw types, see "2.1.2 Screw types used in the printer (p40)". 2. Remove the USB/FAX Cover. (P.94)
1. Remove the following parts. 3. Remove the Main Board Unit. (P.96)
WF-6590/WF-6530 Series 4. Remove the Ink Supply Unit and Printhead. (P.135)
1). Remove the Panel Assy. (P.66) Make sure to not disconnect the connection of the
2). Remove the Paper Support Support. (P.62) Ink Supply Unit and Printhead.
3). Remove the Left ADF Hinge Cover. (P.63)
4). Remove the Right ADF Hinge Cover. (P.64)
5). Remove the ADF/Scanner Unit. (P.181)
6). Remove the Panel Lower Front Cover. (P.68)
7). Remove the Right Upper Front Cover. (P.69) 5. Remove the Head FFC. (P.119)
8). Remove the Stacker Assy. (P.62) 6. Remove the CR Scale. (P.116)
9). Remove the Cassette Assy. (P.203)
10). Remove the Front Cover Microswitch. (P.69) 7. Remove the APG Gear Assy.(P.129)
11). Remove the Front Housing. (P.70) 8. Remove the CR Driven Pulley Assy. (P.121)
12). Remove the Middle Housing. (P.73)
9. Remove the USB Connector Assy. (P.95)
10. Remove the CR Motor. (P.121)
11. At the full side, remove the CR Support Spring. 13. Remove the E-ring and bush, and remove the APG Gear and parallel pin.
CR Support Spring
APG Gear
E-ring
Parallel pin
Bush
Figure 2-120. Removeing CR Support Spring at the full side When removing the APG Gear, be careful not to touch the PF
12. Remove the screw (S16), remove the CR Support Plate. Scale.
Be careful not to drop the parallel pin.
CR Support Plate
14. At the home side, put a marking at the point where the rib on the frame is in
contact with the Right PG Adjust lever.
Rib Marking
Figure 2-121. Removing the CR Support Plate at the full side. Figure 2-123. Marking on the Right PG Adjust Lever at the home side