INSTALLATION

How to Use the Ball Gap Matrix


The rail temperature at the inspection is 10oC(50oF). Max rail
temperature is reached during sanitation and is 50oC(122oF).
According to the matrix a total ball gap of 8 balls (see highlight-
ed cell in table 2) should be installed in the outer driver system
on a GC M7.

GC Ball Gap Matrix


Inner Drive
t1-t2 Total ball gap to be installed in number of balls
t ( C)
o GCP42 GC M58 CL600 / GC60 GC M7 / M8 GC M9 / M92 GC M10 / M106
0 C (32 F)
O o
3 4 4 4 5 6
10oC (50oF) 3 4 4 5 6 7
20oC (68oF) 3 5 5 6 7 8
30oC (86oF) 4 5 6 6 8 9
40oC (104oF) 4 6 6 7 9 10
50oC (122oF) 4 6 7 8 10 10
60 C (140 F)
o o
4 7 7 8 10 11
70oC (158oF) 5 7 8 9 11 12
80oC (176oF) 5 8 8 10 12 13
90oC (194oF) 5 8 9 11 14 15
100oC (212oF) 6 9 9 11 14 15

1000-07-01GB-37-02
t1=Max rail temperature.
t2=Rail temperature at installation.
t= t1-t2

Outer Drive
t1-t2 Total ball gap to be installed in number of balls
t ( C)
o GCP42 GC M58 CL600 / GC60 GC M7 / M8 GC M9 / M92 GC M10 / M106
0OC (32oF) 3 4 4 5 6 6
10 C (50 F)
o o
4 5 5 6 7 7
20oC (68oF) 4 5 6 6 8 8
30oC (86oF) 4 6 6 7 9 9
40oC (104oF) 5 7 7 8 10 11
50oC (122oF) 5 7 8 9 11 12
60oC (140oF) 6 8 8 9 12 13
70oC (158oF) 6 8 9 10 13 14
80oC (176oF) 6 9 10 11 14 15
90oC (194oF) 7 10 10 12 15 16
100oC (212oF) 7 10 11 12 16 17
t1=Max rail temperature.
t2=Rail temperature at installation.
t= t1-t2

~~~