EngSolutions RCB Version 9.1.

1 - License No: A7225-A13579


==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-1 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 A(1-2) V30X45 4 5.8 4.5
1(A-B) V30X45 1 6.8 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 0.0 30.2
Cb = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 2.0 2.6
Joint shear Vj --> = 18.5 27.6
Shear ratio Vj/ØVc = 0.30 0.44
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 36.0 0.0
Ca = 1.25 fy As+ . = 0.0 23.7
Vcol . . . . . . . = 3.1 2.1
Joint shear Vj <-- = 32.8 21.6
Shear ratio Vj/ØVc = 0.52 0.34
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.52


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-1 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 A(1-2) V30X45 4 5.0 3.9
1(A-B) V30X45 1 5.9 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 0.0 26.3
Cb = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 2.0 2.3
Joint shear Vj --> = 18.6 24.0
Shear ratio Vj/ØVc = 0.30 0.38
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 31.1 0.0
Ca = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 2.8 1.9
Joint shear Vj <-- = 28.3 18.7
Shear ratio Vj/ØVc = 0.45 0.30
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.45


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-1 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 A(1-2) V30X40 4 3.4 3.4
1(A-B) V30X45 1 3.9 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 0.0 17.9
Cb = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 2.9 2.1
Joint shear Vj --> = 17.6 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 20.6 0.0
Ca = 1.25 fy As+ . = 0.0 17.9
Vcol . . . . . . . = 2.9 2.1
Joint shear Vj <-- = 17.6 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.28


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-1 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 B(1-2) V30X45 4 6.1 4.7
1(A-B) V30X45 3 6.8 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 35.9 32.2
Cb = 1.25 fy As+ . = 0.0 0.0
Vcol . . . . . . . = 3.1 2.8
Joint shear Vj --> = 32.8 29.4
Shear ratio Vj/ØVc = 0.52 0.47
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 0.0
Ca = 1.25 fy As+ . = 20.6 24.6
Vcol . . . . . . . = 2.0 2.2
Joint shear Vj <-- = 18.6 22.3
Shear ratio Vj/ØVc = 0.30 0.36
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.52


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-1 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 B(1-2) V30X45 4 5.5 3.9
1(A-B) V30X45 3 5.9 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 31.0 28.9
Cb = 1.25 fy As+ . = 0.0 0.0
Vcol . . . . . . . = 2.8 2.5
Joint shear Vj --> = 28.2 26.4
Shear ratio Vj/ØVc = 0.45 0.42
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 0.0
Ca = 1.25 fy As+ . = 20.6 20.6
Vcol . . . . . . . = 2.0 1.9
Joint shear Vj <-- = 18.6 18.7
Shear ratio Vj/ØVc = 0.30 0.30
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.45


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-1 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 B(1-2) V30X40 4 3.4 3.4
1(A-B) V30X45 3 3.9 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 20.6 17.9
Cb = 1.25 fy As+ . = 0.0 0.0
Vcol . . . . . . . = 2.9 2.2
Joint shear Vj --> = 17.6 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 0.0
Ca = 1.25 fy As+ . = 20.6 17.9
Vcol . . . . . . . = 2.9 2.2
Joint shear Vj <-- = 17.6 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.28


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-2 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 A(1-2) V30X45 2 5.5 4.0
A(2-3) V30X45 4 5.5 4.0
Dir. 2 Dir. 3 2(A-B) V30X45 1 9.2 4.4
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 2
ØVc . . . . . . . . = 78.4 78.4

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 0.0 28.7
Cb = 1.25 fy As+ . = 22.9 21.2
Vcol . . . . . . . = 2.4 4.4
Joint shear Vj --> = 20.5 45.5
Shear ratio Vj/ØVc = 0.26 0.58
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 48.3 28.7
Ca = 1.25 fy As+ . = 0.0 21.2
Vcol . . . . . . . = 4.2 4.4
Joint shear Vj <-- = 44.1 45.5
Shear ratio Vj/ØVc = 0.56 0.58
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.58


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-2 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 A(1-2) V30X45 2 4.7 3.9
A(2-3) V30X45 4 4.7 3.9
Dir. 2 Dir. 3 2(A-B) V30X45 1 8.7 4.1
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 2
ØVc . . . . . . . . = 78.4 78.4

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 0.0 24.5
Cb = 1.25 fy As+ . = 21.7 20.6
Vcol . . . . . . . = 2.4 4.0
Joint shear Vj --> = 19.3 41.1
Shear ratio Vj/ØVc = 0.25 0.52
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 45.5 24.5
Ca = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 4.1 4.0
Joint shear Vj <-- = 41.4 41.1
Shear ratio Vj/ØVc = 0.53 0.52
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.53


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-2 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 A(1-2) V30X40 2 3.4 3.4
A(2-3) V30X40 4 3.4 3.4
Dir. 2 Dir. 3 2(A-B) V30X45 1 4.8 3.9
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 2
ØVc . . . . . . . . = 78.4 78.4

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 0.0 17.9
Cb = 1.25 fy As+ . = 20.6 17.9
Vcol . . . . . . . = 3.2 4.2
Joint shear Vj --> = 17.3 31.6
Shear ratio Vj/ØVc = 0.22 0.40
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 24.9 17.9
Ca = 1.25 fy As+ . = 0.0 17.9
Vcol . . . . . . . = 3.7 4.2
Joint shear Vj <-- = 21.2 31.6
Shear ratio Vj/ØVc = 0.27 0.40
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.40


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-2 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 B(1-2) V30X45 2 5.6 4.3
B(2-3) V30X45 4 5.6 4.3
Dir. 2 Dir. 3 2(A-B) V30X45 3 9.9 4.7
Effective width, be = 40 40 2(B-C) V30X45 1 9.9 4.7
Effective area, Ae = 1600 1600
Confined faces . . = 2 2
ØVc . . . . . . . . = 104.6 104.6

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 51.8 29.3
Cb = 1.25 fy As+ . = 24.5 22.8
Vcol . . . . . . . = 6.9 4.5
Joint shear Vj --> = 69.4 47.6
Shear ratio Vj/ØVc = 0.66 0.45
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 51.8 29.3
Ca = 1.25 fy As+ . = 24.5 22.8
Vcol . . . . . . . = 6.9 4.5
Joint shear Vj <-- = 69.4 47.6
Shear ratio Vj/ØVc = 0.66 0.45
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.66


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-2 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 B(1-2) V30X45 2 4.7 3.9
B(2-3) V30X45 4 4.7 3.9
Dir. 2 Dir. 3 2(A-B) V30X45 3 8.7 4.1
Effective width, be = 40 40 2(B-C) V30X45 1 8.7 4.1
Effective area, Ae = 1600 1600
Confined faces . . = 2 2
ØVc . . . . . . . . = 104.6 104.6

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 45.8 24.8
Cb = 1.25 fy As+ . = 21.8 20.6
Vcol . . . . . . . = 6.3 4.0
Joint shear Vj --> = 61.2 41.3
Shear ratio Vj/ØVc = 0.59 0.40
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 45.8 24.8
Ca = 1.25 fy As+ . = 21.8 20.6
Vcol . . . . . . . = 6.3 4.0
Joint shear Vj <-- = 61.2 41.3
Shear ratio Vj/ØVc = 0.59 0.40
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.59


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-2 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 B(1-2) V30X40 2 3.4 3.4
B(2-3) V30X40 4 3.4 3.4
Dir. 2 Dir. 3 2(A-B) V30X45 3 5.5 3.9
Effective width, be = 40 40 2(B-C) V30X45 1 5.5 3.9
Effective area, Ae = 1600 1600
Confined faces . . = 2 2
ØVc . . . . . . . . = 104.6 104.6

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 29.1 17.9
Cb = 1.25 fy As+ . = 20.6 17.9
Vcol . . . . . . . = 7.4 4.2
Joint shear Vj --> = 42.3 31.6
Shear ratio Vj/ØVc = 0.40 0.30
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 29.1 17.9
Ca = 1.25 fy As+ . = 20.6 17.9
Vcol . . . . . . . = 7.4 4.2
Joint shear Vj <-- = 42.3 31.6
Shear ratio Vj/ØVc = 0.40 0.30
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.40


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: D-2 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 D(2-2a) V30X45 4 5.6 4.1
2(C-D) V30X45 3 7.7 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 40.5 29.2
Cb = 1.25 fy As+ . = 0.0 0.0
Vcol . . . . . . . = 3.6 2.5
Joint shear Vj --> = 36.9 26.7
Shear ratio Vj/ØVc = 0.59 0.43
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 0.0
Ca = 1.25 fy As+ . = 20.6 21.4
Vcol . . . . . . . = 2.1 1.9
Joint shear Vj <-- = 18.4 19.5
Shear ratio Vj/ØVc = 0.29 0.31
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.59


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: D-2 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 D(2-2a) V30X45 4 4.8 3.9
2(C-D) V30X45 3 7.2 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 37.9 25.0
Cb = 1.25 fy As+ . = 0.0 0.0
Vcol . . . . . . . = 3.4 2.2
Joint shear Vj --> = 34.4 22.8
Shear ratio Vj/ØVc = 0.55 0.36
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 0.0
Ca = 1.25 fy As+ . = 20.6 20.6
Vcol . . . . . . . = 2.1 1.8
Joint shear Vj <-- = 18.4 18.7
Shear ratio Vj/ØVc = 0.29 0.30
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.55


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: D-2 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 D(2-2a) V30X40 4 3.4 3.4
2(C-D) V30X45 3 3.9 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 20.6 17.9
Cb = 1.25 fy As+ . = 0.0 0.0
Vcol . . . . . . . = 3.1 2.1
Joint shear Vj --> = 17.5 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 0.0
Ca = 1.25 fy As+ . = 20.6 17.9
Vcol . . . . . . . = 3.1 2.1
Joint shear Vj <-- = 17.5 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.28


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-3 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

3 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


2 Sec: C40X40 A(2-3) V30X45 3 4.8 3.9
3(A-B) V30X45 2 8.0 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 25.0 0.0
Cb = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 2.1 2.1
Joint shear Vj --> = 22.8 18.5
Shear ratio Vj/ØVc = 0.36 0.29
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 41.8
Ca = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 1.8 3.6
Joint shear Vj <-- = 18.8 38.1
Shear ratio Vj/ØVc = 0.30 0.61
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.61


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-3 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

3 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


2 Sec: C40X40 A(2-3) V30X45 3 4.2 3.9
3(A-B) V30X45 2 7.2 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 22.1 0.0
Cb = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 1.9 2.1
Joint shear Vj --> = 20.1 18.5
Shear ratio Vj/ØVc = 0.32 0.29
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 37.7
Ca = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 1.8 3.4
Joint shear Vj <-- = 18.7 34.3
Shear ratio Vj/ØVc = 0.30 0.55
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.55


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: A-3 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

3 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


2 Sec: C40X40 A(2-3) V30X40 3 3.4 3.4
3(A-B) V30X45 2 3.9 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 17.9 0.0
Cb = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 2.1 3.0
Joint shear Vj --> = 15.8 17.5
Shear ratio Vj/ØVc = 0.25 0.28
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 20.6
Ca = 1.25 fy As+ . = 17.9 0.0
Vcol . . . . . . . = 2.1 3.0
Joint shear Vj <-- = 15.8 17.5
Shear ratio Vj/ØVc = 0.25 0.28
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.28


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-3 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

3 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


2 Sec: C40X40 B(2-3) V30X45 3 5.0 3.9
3(A-B) V30X45 4 8.7 4.1
Dir. 2 Dir. 3 3(B-C) V30X45 2 8.7 4.1
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 2
ØVc . . . . . . . . = 78.4 78.4

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 26.1 45.4
Cb = 1.25 fy As+ . = 0.0 21.6
Vcol . . . . . . . = 2.2 6.1
Joint shear Vj --> = 23.9 60.9
Shear ratio Vj/ØVc = 0.30 0.78
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 45.4
Ca = 1.25 fy As+ . = 20.6 21.6
Vcol . . . . . . . = 1.8 6.1
Joint shear Vj <-- = 18.8 60.9
Shear ratio Vj/ØVc = 0.24 0.78
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.78


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-3 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

3 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


2 Sec: C40X40 B(2-3) V30X45 3 4.4 3.9
3(A-B) V30X45 4 7.5 3.9
Dir. 2 Dir. 3 3(B-C) V30X45 2 7.5 3.9
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 2
ØVc . . . . . . . . = 78.4 78.4

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 23.3 39.4
Cb = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 2.0 5.6
Joint shear Vj --> = 21.3 54.3
Shear ratio Vj/ØVc = 0.27 0.69
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 39.4
Ca = 1.25 fy As+ . = 20.6 20.6
Vcol . . . . . . . = 1.8 5.6
Joint shear Vj <-- = 18.7 54.3
Shear ratio Vj/ØVc = 0.24 0.69
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.69


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: B-3 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

3 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


2 Sec: C40X40 B(2-3) V30X40 3 3.4 3.4
3(A-B) V30X45 4 4.7 3.9
Dir. 2 Dir. 3 3(B-C) V30X45 2 4.7 3.9
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 2
ØVc . . . . . . . . = 78.4 78.4

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 17.9 24.6
Cb = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 2.1 6.6
Joint shear Vj --> = 15.8 38.6
Shear ratio Vj/ØVc = 0.20 0.49
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 24.6
Ca = 1.25 fy As+ . = 17.9 20.6
Vcol . . . . . . . = 2.1 6.6
Joint shear Vj <-- = 15.8 38.6
Shear ratio Vj/ØVc = 0.20 0.49
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.49


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: D-3 FLOOR: 2 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 D(2a-3) V30X45 2 5.7 4.0
3(C-D) V30X45 3 8.2 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 43.1 0.0
Cb = 1.25 fy As+ . = 0.0 21.1
Vcol . . . . . . . = 3.8 1.9
Joint shear Vj --> = 39.4 19.2
Shear ratio Vj/ØVc = 0.63 0.31
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 29.8
Ca = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 2.1 2.5
Joint shear Vj <-- = 18.5 27.2
Shear ratio Vj/ØVc = 0.29 0.43
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.63


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: D-3 FLOOR: 3 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 D(2a-3) V30X45 2 4.9 3.9
3(C-D) V30X45 3 7.5 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 39.2 0.0
Cb = 1.25 fy As+ . = 0.0 20.6
Vcol . . . . . . . = 3.5 1.8
Joint shear Vj --> = 35.7 18.7
Shear ratio Vj/ØVc = 0.57 0.30
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 25.8
Ca = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 2.1 2.2
Joint shear Vj <-- = 18.4 23.5
Shear ratio Vj/ØVc = 0.29 0.37
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.57


EngSolutions RCB Version 9.1.1 - License No: A7225-A13579
==============================================================================================
Company: COINGEST SAS Engineer: ING MIGUEL PINZON
Project: Untitled 11:51:55 a. m. 23/01/2024
==============================================================================================

AXIS: D-3 FLOOR: 4 B E A M - C O L U M N J O I N T S H E A R C H E C K UNITS: ton, cm, cm²

2 Mat: 3000PSI Beam Section Col.Face As(top) As(bot)


3 Sec: C40X40 D(2a-3) V30X40 2 3.4 3.4
3(C-D) V30X45 3 4.0 3.9
Dir. 2 Dir. 3
Effective width, be = 40 40
Effective area, Ae = 1600 1600
Confined faces . . = 1 1
ØVc . . . . . . . . = 62.7 62.7

SWAY ---------> Dir. 2+ Dir. 3+


Ta = 1.25 fy As- . = 21.2 0.0
Cb = 1.25 fy As+ . = 0.0 17.9
Vcol . . . . . . . = 3.1 2.1
Joint shear Vj --> = 18.0 15.8
Shear ratio Vj/ØVc = 0.29 0.25
SHEAR CHECK -----> = OK OK

SWAY <--------- Dir. 2- Dir. 3-


Tb = 1.25 fy As- . = 0.0 17.9
Ca = 1.25 fy As+ . = 20.6 0.0
Vcol . . . . . . . = 3.1 2.1
Joint shear Vj <-- = 17.5 15.8
Shear ratio Vj/ØVc = 0.28 0.25
SHEAR CHECK <----- = OK OK

MAX. SHEAR RATIO, Vj/ØVc = 0.29