Utilization Ratio: C-100x50x5x7.5D Double Channel Back To Back
Utilization Ratio: C-100x50x5x7.5D Double Channel Back To Back
Utilization Ratio: C-100x50x5x7.5D Double Channel Back To Back
1
Software licensed to Shinryo Corporation Part
CONNECTED User: Khun Rashaton
Job Title Ref
By Date23-Jun-20 Chd
Utilization Ratio
Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
7512 C100X50X5 C100X50X5 0.258 1.000 0.258 AISC- H2-1 100 23.840 375.996 151.211 3.440
10140 C100X50X5 C100X50X5 0.000 1.000 0.000 SHEAR -Y 100 23.840 375.996 151.211 3.440
10153 C100X50X5 C100X50X5 0.000 1.000 0.000 SHEAR -Y 100 23.840 375.996 151.211 3.440
C-100x50x5x7.5D
Double channel
back to back