50x50mm purlin

75x100mm rafter
35° inclined Envirosphere Concepts
KM 1 Umukalika/Ngboko Road
Aba
140x140mm wall plate Nigeria
10mm rods for
2 parapet
6mm rod for rings

0.30
7 6 5 4 3 1 12mm rods for

Date
beam
Roof Members
100x50mm king post 0.90 3.28 2.43 2.06 0.37 1.05

140x140mm hard wood


wall plates 4 Roof Pitch 4 Roof Pitch
+13.469 +13.469 0.22

Change Name
aluminium roofing 0.40
sheets fixed to
hardwood purlins with
aluminium screw.
Detail
0.55mm thick D-01 SCALE 1:50

ChID
3.86
aluminium flashings.

50mmx50mm hard

RevID
wood purlins @ 900 c/c. D-01

75mmx100mm hard
wood rafters @ 1200mm
c/c. 3 Roof Eve 3 Roof Eve
+9.614 +9.614
50mmx100mm struts.

Proposed Residential Building


0.90
0.29

50mmx100mm struts.
(diagonal) walls composed of
machine vibrated
Stair Hall

3.21

Eastern Province, Kalahun District.


50mmx50mm ceiling sandcrete block units
noggings. elevated water tank laid in strtcher

Daru Town, Jawei Chiefdom


2.06
bond and rendered
400mmx300mm smooth with cement-
4.63

concrete facia. sand mortar to


architect's
2 Second Floor 2 Second Floor recommendation

Sierra Leone.
+6.400 +6.400

Daru Road
all internal wall surfaces
6.41

must be rendered
smooth finish with POP
(plaster of paris)
and painted with

3.20
elevated water tank

3.00
150mm mass concrete approved emulsion paint
floor slab to structural or otherwise stated
engineer's drawing D-02
details reinforced concrete
staircase with 150mm
300mm thick 1 First Floor 1 First Floor
rise and 300mm trad and
finished with
3.05

compacted hard core +3.200 +3.200


filling of broken stones granite slabs or its
to architect's wquivalent complete with
0.90

recommendation. 0.90 stainless steel handrails


to architect's
Sub-structural block recommendation
wall composed of

3.20
3.00

machine vibrated Burglary grille to


2.70

hollow sandcrete block windows shall be limited


2.06

units filled with to openings on the


1.43

concrete to architect's ground floor only


recommendation. Date
Foundation type, depth 0 Ground Floor 0 Ground Floor January 2024
0.43

and reinforcement to ±0.000 ±0.000


be determined by the
structural engineer.
Drawing Name
1.92

Building Section,
-1 Foundation Footing -1 Foundation Footing Detail
-1.920 -1.920

0.20
16mm rods for

0.50
16mm rods for
beams

0.30
cantilever beams
Drawing Scale
1:100, 1:30

0.30
12mm rods for
Building Section
S-1 lintols

0.30
SCALE 1:100

Sheet ID

A.01.6.1
Detail
D-02 SCALE 1:50
GSPublisherVersion 0.0.100.100