Calcul conducte sub presiune

Debit Q= 0.001940 [mc/s]


Coef de vascozitate n= 1 10e-6 [mp/s]
Diametru D= 0.043 [m]
.

V= (4*Q)/(3,14*D^2) 1.3478412613776 [m/s]

Re = (V x D)/n = 57714.562812187

Rugozitate ke= 0.15

Lamda = 0,11 x ( ke/D + 68/Re )^0,25

ke/D = 0.003503
68/Re = 0.001178
S1 = ke/D + 68/Re = 0.004681
S1^0,25 = 0.261571
Lamda = 0,11 x S1 = 0.028773

Modul de rezistenta M = 0,0826 x ( Lamda x L )/D^5

Lungime conducta L= 8.30 [m]

S2 = 0,0826 x ( Lamda x L ) = 0.0197


D^5 = 0.000000
M= 137027.5603 [s^2/m^5]

Pierdere liniara hd = (Lamda x L /D ) / ( V² / ( 2 x g ) )=

(Lamda x L)/D = 5.5771783132349


V² / (2 x g ) = 0.093
hd1= 0.5164 [mCA]