Airplane Identifier Status Flight Number Leg Count Leg Date Departure/Arrival
VT-ANJ New AI135 0 22-Mar-2018 : 11:27 MAA/MAD

Process Items Close Window Item History Screen Help Print

Maintenance memo shows on


Fault-FDE: 342 463 42 17-Mar-2018 : 06:50 Inactive -12
CMCF: AHRU R - MMO

[ ] 27-14113 Climb Intermittent (1) 17-Mar-2018 : 06:50 Inactive


-12
Right Flight Controls Module is inoperative.
Maintenance memo shows on
Fault-FDE: 342 464 42 17-Mar-2018 : 06:50 Inactive -12
CMCF: IRU R - MMO

[ ] 27-14113 Climb Intermittent (1) 17-Mar-2018 : 06:50 Inactive


-12
Right Flight Controls Module is inoperative.
NITROGEN GENERATION SYS:
Fault-FDE: message (Status) shows on 471 121 00 22-Mar-2018 : 11:29 Active 0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11 -12 -13 -14
EICAS - STATUS

[ ] 24-50247 Engine Start Mode 22-Mar-2018 : 01:16 Latched


-2
Right APU Start Contactor does not follow open command.

[ ] 24-50897 Engine Start Mode 22-Mar-2018 : 01:16 Latched


Common Motor Start Controller (Right 2 CAC) has detected an internal or feeder -2 -3 -4 -5 -6 -7 -8 -9 -11 -12 -13
fault.

[ ] 24-50898 Engine Start Mode 22-Mar-2018 : 01:16 Latched


Common Motor Start Controller (Right 2 EMP) has detected an internal or feeder -2 -3 -4 -5 -6 -7 -8 -9 -11 -12 -13
fault.

[ ] 24-50977 Engine Start Mode 12-Mar-2018 : 03:44 Latched


Common Motor Start Controller (Right 2 CAC) speed is too low.

[ ] 27-13502 Engine Start Hard 10-Mar-2018 : 22:24 Active


C1 Flight Controls Module circuit breaker is open.

[ ] 27-14112 Cruise Hard 10-Mar-2018 : 15:33 Active


C1 Flight Controls Module is inoperative.

[ ] 27-14113 Climb Intermittent (1) 17-Mar-2018 : 06:50 Inactive


Right Flight Controls Module is inoperative.

[ ] 47-10240 Cruise Mode 06-Mar-2018 : 21:36 Active


NGS Flow Control/Ejector Valve position feedback does not agree with commanded
position.

[ ] 47-10980 Engine Start Mode 22-Mar-2018 : 11:29 Active


0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11
NGS Compressor Motor controller has a fault.
Quick Reference Handbook
B787QuickReferenceHandbook(QRH)-FORREFERENCEONLY.pdf
Show All Documents Preferences Advanced Flight History Bar

Fault-FDE: Maintenance memo shows on CMCF: AHRU R - MMO 342 463 42 Repeat Return to Top

Activity Date Leg Count History Notes


-12
Inactive 17-Mar : 06:50 -12 I
Minimum Equipment List (MEL)
Check MEL. AHM is unable to determine if a MEL item exists for this fault.
Fault Isolation Manual (FIM)
Fault Isolation Manual for: Maintenance memo shows on CMCF: AHRU R - 342 463 42

Fault-FDE: Maintenance memo shows on CMCF: IRU R - MMO 342 464 42 Repeat Return to Top

Activity Date Leg Count History Notes


-12
Inactive 17-Mar : 06:50 -12 I
Minimum Equipment List (MEL)
Check MEL. AHM is unable to determine if a MEL item exists for this fault.
Fault Isolation Manual (FIM)
Fault Isolation Manual for: Maintenance memo shows on CMCF: IRU R - 342 464 42

Fault-FDE: NITROGEN GENERATION SYS: message (Status) shows on EICAS - STATUS 471 121 00 Repeat Return to Top

Activity Date Leg Count History Notes


0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11 -12 -13 -14
Active 22-Mar : 11:29 0 A A A A A A A A A A A A A A A

https://www.myboeingfleet.com/ahm/classic/wrapperFaultDetails.jsp?gAISList=143495420&aC=AIN&pWAII=2 1/6
3/22/2018 AHM: Fault Item Details
Minimum Equipment List (MEL)
47-11-1-1 Nitrogen Generation Performance
Service Letters Show
Fleet Team Digest Show
Fault Isolation Manual (FIM)
Fault Isolation Manual for: NITROGEN GENERATION SYS - 471 121 00

MMSG: 27-14113 - Right Flight Controls Module is inoperative. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes


-12
Inactive Intermittent(1) Climb 17-Mar : 06:50 -12 I
CL
Detected By
27 FCM OPS (LEFT)
Fault Report Code - Monitor Code
14113 - 15047 15053 15128 15048
Possible Causes PRITA
Fix Effectiveness
Part Name Maintenance Action
Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Checked OK All 49 83.7 30.3
AIN 0 0.0 0.0
Maint. (Other) All 16 81.2 9.9
AIN 0 0.0 0.0
Flight Controls Module (FCM) (Right) E2702004M3 Replaced All 21 85.7 8.3
AIN 0 0.0 0.0
Flight Controls Module (FCM) (C1) E2702001M3 Replaced All 1 100.0 0.6
AIN 0 0.0 0.0
Right Actuator Control Electronics (ACE) Module E2702004M2 Replaced All 1 100.0 0.1
AIN 0 0.0 0.0
Unknown Replaced All 2 100.0 1.8
AIN 0 0.0 0.0
Right Power Conditioning Module (PCM) E2702004M1 Replaced All 0 0.0 0.0

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 27-14113
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken
Maintenance Tips Show
Service Letters Show
Fleet Team Digest Show

MMSG: 24-50247 - Right APU Start Contactor does not follow open command. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes


-2
Latched Mode Engine Start 22-Mar : 01:16 -2 L
ES
Detected By
COMMON MOTOR START CONTROLLER (RIGHT 2 CAC)
Fault Report Code - Monitor Code
2074 -

Possible Causes PRITA


Fix Effectiveness
Part Name Maintenance Action
Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Checked OK All 98 55.1 46.7
AIN 0 0.0 0.0
Auxiliary Power Unit (APU) Start Contactor (Right) CK2412502 Replaced All 12 50.0 2.9
AIN 0 0.0 0.0
Maint. (Other) All 2 100.0 1.8
AIN 0 0.0 0.0
Common Motor Start Controller (CMSC) (Right) (2) CAC M2415041 Replaced All 6 100.0 1.0
AIN 0 0.0 0.0
Unknown Replaced All 3 66.7 1.8
AIN 0 0.0 0.0
Wiring Replaced All 0 0.0 0.0

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 24-50247
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken
Fleet Team Digest Show

https://www.myboeingfleet.com/ahm/classic/wrapperFaultDetails.jsp?gAISList=143495420&aC=AIN&pWAII=2 2/6
3/22/2018 AHM: Fault Item Details

MMSG: 24-50897 - Common Motor Start Controller (Right 2 CAC) has detected an internal or feeder fault. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes


-2 -3 -4 -5 -6 -7 -8 -9 -11 -12 -13
Latched Mode Engine Start 22-Mar : 01:16 -2 L L L L L L L L L L L
ES ES ES ES ES ES ES TA ES ES ES
Detected By
COMMON MOTOR START CONTROLLER (RIGHT 2 CAC)
Fault Report Code - Monitor Code
2052 -

Possible Causes PRITA


Maintenance Fix Effectiveness
Part Name
Action Operator Graph Attempts Fix % Score

Nitrogen Generation System (NGS) Motor Driven Compressor (MDC) AIN 0 0.0 0.0
Replaced All 223 59.2 92.2
B4700001
AIN 0 0.0 0.0
Common Motor Start Controller (CMSC) (Right) (2) CAC M2415041 Replaced All 79 44.3 18.3
AIN 0 0.0 0.0
Checked OK All 110 13.6 12.8

Common Motor Start Controller (CMSC) (Right) (2) Electric Motor Pump AIN 0 0.0 0.0
Replaced All 1 100.0 0.6
(EMP) M2415042
AIN 0 0.0 0.0
Unknown Replaced All 20 30.0 5.8
AIN 0 0.0 0.0
HVDC Power Panel (Right) P800 Replaced All 0 0.0 0.0
AIN 0 0.0 0.0
Wiring Replaced All 0 0.0 0.0

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 24-50897
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken
Service Letters Show

MMSG: 24-50898 - Common Motor Start Controller (Right 2 EMP) has detected an internal or feeder fault. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes


-2 -3 -4 -5 -6 -7 -8 -9 -11 -12 -13
Latched Mode Engine Start 22-Mar : 01:16 -2 L L L L L L L L L L L
ES ES ES ES ES ES ES TA ES ES ES
Detected By
COMMON MOTOR START CONTROLLER (RIGHT 2 EMP)
Fault Report Code - Monitor Code
2052 -

Possible Causes PRITA

Maintenance Fix Effectiveness


Part Name
Action Operator Graph Attempts Fix % Score

Nitrogen Generation System (NGS) Motor Driven Compressor (MDC) AIN 0 0.0 0.0
Replaced All 231 59.3 96.8
B4700001
AIN 0 0.0 0.0
Checked OK All 124 21.8 23.6

Common Motor Start Controller (CMSC) (Right) (2) Electric Motor Pump AIN 0 0.0 0.0
Replaced All 76 46.1 17.2
(EMP) M2415042
AIN 0 0.0 0.0
Common Motor Start Controller (CMSC) (Right) (2) CAC M2415041 Replaced All 1 100.0 0.4
AIN 0 0.0 0.0
Wiring Replaced All 3 33.3 0.2
AIN 0 0.0 0.0
Unknown Replaced All 21 33.3 6.4
AIN 0 0.0 0.0
HVDC Power Panel (Right) P800 Replaced All 0 0.0 0.0

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 24-50898
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken
Service Letters Show

MMSG: 24-50977 - Common Motor Start Controller (Right 2 CAC) speed is too low. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes

Latched Mode Engine Start 12-Mar : 03:44 -27


Detected By

https://www.myboeingfleet.com/ahm/classic/wrapperFaultDetails.jsp?gAISList=143495420&aC=AIN&pWAII=2 3/6
3/22/2018 AHM: Fault Item Details
COMMON MOTOR START CONTROLLER (RIGHT 2 CAC)
Fault Report Code - Monitor Code
2055 -

Possible Causes PRITA


Fix Effectiveness
Part Name Maintenance Action
Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Checked OK All 9 44.4 3.3
AIN 0 0.0 0.0
Common Motor Start Controller (CMSC) (Right) (2) CAC M2415041 Replaced All 4 25.0 0.9
AIN 0 0.0 0.0
Right 2 Cabin Air Compressor (CAC) M2151004 Replaced All 9 66.7 0.5
AIN 0 0.0 0.0
Unknown Replaced All 5 80.0 3.6

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 24-50977
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken
Fleet Team Digest Show

MMSG: 27-13502 - C1 Flight Controls Module circuit breaker is open. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes

Active Hard Engine Start 10-Mar : 22:24 -29


Detected By
27 FCM OPS (LEFT)
27 FCM OPS (RIGHT)
Fault Report Code - Monitor Code
13502 13502 -
Possible Causes PRITA
Fix Effectiveness
Part Name Maintenance Action
Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Flight Controls Module (FCM) (C1) E2702001M3 Replaced All 3 66.7 1.4
AIN 0 0.0 0.0
C1 Power Conditioning Module (PCM) E2702001M1 Replaced All 0 0.0 0.0
AIN 0 0.0 0.0
Flight Controls Electronics (FCE) Cabinet (C1) E2702001 Replaced All 0 0.0 0.0

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 27-13502
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken

MMSG: 27-14112 - C1 Flight Controls Module is inoperative. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes

Active Hard Cruise 10-Mar : 15:33 -30


Detected By
27 FCM OPS (LEFT)
27 FCM OPS (RIGHT)
Fault Report Code - Monitor Code
14112 14112 -

Possible Causes PRITA


Fix Effectiveness
Part Name Maintenance Action
Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Checked OK All 83 71.1 44.7
AIN 0 0.0 0.0
Flight Controls Module (FCM) (C1) E2702001M3 Replaced All 20 90.0 10.7
AIN 0 0.0 0.0
Maint. (Other) All 7 85.7 4.5
AIN 0 0.0 0.0
C1 Power Conditioning Module (PCM) E2702001M1 Replaced All 1 100.0 0.5
AIN 0 0.0 0.0
C1 Actuator Control Electronics (ACE) Module E2702001M2 Replaced All 4 25.0 0.1
AIN 0 0.0 0.0
Unknown Replaced All 14 57.1 7.2

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 27-14112
AHM Reports
Fault Summary
https://www.myboeingfleet.com/ahm/classic/wrapperFaultDetails.jsp?gAISList=143495420&aC=AIN&pWAII=2 4/6
3/22/2018 AHM: Fault Item Details
Message Detail Message Occurrence Graphical Report Action Taken
Maintenance Tips Show
Service Letters Show
Fleet Team Digest Show

MMSG: 47-10240 - NGS Flow Control/Ejector Valve position feedback does not agree with commanded position. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes

Active Mode Cruise 06-Mar : 21:36 -39


Detected By
47 NGS OPS
Fault Report Code - Monitor Code
10240 -
Possible Causes PRITA
Maintenance Fix Effectiveness
Part Name
Action Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Checked OK All 109 45.0 41.1
AIN 0 0.0 0.0
Nitrogen Generation System (NGS) Flow Control Ejector Valve V4730001 Replaced All 15 80.0 3.7

Common Core System (CCS) Remote Data Concentrator (RDC) (21) (Crown AIN 0 0.0 0.0
Replaced All 1 100.0 0.8
Door) (2) (Left) M4240021
AIN 0 0.0 0.0
Maint. (Other) All 1 100.0 0.7
AIN 0 0.0 0.0
Unknown Replaced All 14 57.1 7.2
AIN 0 0.0 0.0
Wiring Replaced All 0 0.0 0.0

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 47-10240
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken

MMSG: 47-10980 - NGS Compressor Motor controller has a fault. Return to Top

Activity Intermittence Flight Phase Date Leg Count History Notes


0 -1 -2 -3 -4 -5 -6 -7 -8 -9 -10 -11 -12 -13 -14
Active Mode Engine Start 22-Mar : 11:29 0 A A A A A A A A A A A A A A A
ES ES ES ES ES ES ES ES ES TA ES ES ES ES ES
Detected By
47 NGS OPS
Fault Report Code - Monitor Code
10980 -
Possible Causes PRITA
Maintenance Fix Effectiveness
Part Name
Action Operator Graph Attempts Fix % Score
AIN 0 0.0 0.0
Checked OK All 367 51.5 156.1

Nitrogen Generation System (NGS) Motor Driven Compressor (MDC) AIN 0 0.0 0.0
Replaced All 270 59.6 110.4
B4700001
AIN 0 0.0 0.0
Common Motor Start Controller (CMSC) (Right) (2) CAC M2415041 Replaced All 72 47.2 14.1

Common Motor Start Controller (CMSC) (Right) (2) Electric Motor Pump AIN 0 0.0 0.0
Replaced All 30 53.3 4.0
(EMP) M2415042
AIN 0 0.0 0.0
Maint. (Other) All 7 57.1 3.3
AIN 0 0.0 0.0
Unknown Replaced All 32 43.8 12.8

Fault Isolation Manual (FIM)


Fault Isolation Manual for: 47-10980
AHM Reports

Fault Summary Message Detail Message Occurrence Graphical Report Action Taken
Maintenance Tips Show

Close Window Item History Help Print

https://www.myboeingfleet.com/ahm/classic/wrapperFaultDetails.jsp?gAISList=143495420&aC=AIN&pWAII=2 5/6
3/22/2018 AHM: Fault Item Details

Copyright © 1999-2018. The Boeing Company. All rights reserved. Terms of Use

https://www.myboeingfleet.com/ahm/classic/wrapperFaultDetails.jsp?gAISList=143495420&aC=AIN&pWAII=2 6/6

You might also like