S PRIME REVIEW ONLINE "MECHANICAL ENGINEERING REVIEW. aa PROPERTIES OF AIR 1. Calculate the specific volume of an ait-vapor mixture in cubic meters per kilogram of dry air when the following conditions prevail: t= 30°C, » = 0.015, kgikg, and P; = 90 kPa A. 0.69 Vk C.0.79 mike. B. 0.89 mvkgs D.0.99 mks A4mx4.mx4 m room has a relative humidity ratio of 80%. The pressure in the room is 120 kPa and. temperature is 35C ( Psat = 5.628). What is the mass of vapor in the room. Use Rvagw = 0.4615 kN-mvkg- K A. 2.03 kgy C. 3.03 kev B. 5.03 kgv D. 1.03 kev AIR MIXING 3. The mass of an outside air at SO°C in an ait conditioning unit is 60 kg. Pind the temperature after mixing if the outside air mixed with 40 kg with recirculated air at 35°C. A. 35°C B. 65°C c.4a°e D.35C 4, In an air conditioning system, if the re-circulated air is three times the outside air and the mass of supply air is 20 kg’s, what is the mass of the outside air? A. Skuis C.Gkels B. 5.5 kgis D.Okgis HEAT LOADS 5. A room being air conditioned is being held at 25°C dry bulb and 50% relative humidity,/A. flow rate of 5 m/s of supply air at 15°C dry bulb aid 80% RH is being delivered to the room to maintain that steady. condition at 100 kPa, What is the sensible heat absorbed fiom the room air in kW? A. 60.5 kW C. 60.5 nP B. 88 kW D.214.2kW 6, Ifthe latent and sensible heat loads are 20 kW and 80 KW respectively, what is the sensible heat ratio? Al Ce B. OS D.08 7. In.an auditorium maintained at a temperature not to exceed 24°C and relative humidity not to exceed 660%, a sensible heat load of 132 kW and 78 kg of moisture per hour to be removed, Airis supplied to the auditorium at 18°C. How many kilograms of air ‘must be supplied per hour? A. 79200 keyhr C.97200 ka/he B. 79002 kghhr D. 72900 kg/hr POWER & INDUSTRIAL PLANT ENGINEERING ‘wor primereviewcentercomm COOLING TOWER 8. Determine the approximate load on a cooling tower if the entering and leaving temperatures are 96°F and 88°F, respectively and the flow rate of the water over the tower is 30 gpm. A. 2000 kW B. 2000 hP €. 2000 BTU/min D. 2000 BUT/s 9. The natural draft cooling tower has a 400 ton heat rejection load. The temperature of the water entering, the cooling tower is 90°F and leaving at 82°F. ‘Compute the approach, range and cooling tower efficiency when the outdoor wet-bulb temperature is IS, B. R=8°C, A=8°C, C.R=7C,A=7Ce D. R=7'C,A DUCTING & DRYER 10. A rectangular duct has a dimension of 0.25 m by 1 m, Determine the equivalent diameter of the duct. A 05m C.045 m B.04m D.0.55m 11, Copra enters a dryer containing 60% water and 40% of solids and feaves with $% water and 95% solids Find the weight of water removed based on each pound of original product. ‘A. 0.85 Ib €.0.58 Ib B_0241b D.0.42 Ib 12, Copra enters a dryer containing 60% water and 40% of solids and leaves with 5% water and 95% solids. Find the weight of water removed based on each pound of origital product. C. 085 Ib C058 Ib D. 0.24 1b D.0.42 Ib FACTORS (BY-PASS & CONTACT) AND BLEED-OFF 13, A-coil has an inlet temperature of 60°F and outlet of 90°F. If the mean tempeature of the coil is 100°F, find the bypass factor of the coil A. 0.60 €.030 B. 052 D.0.40 14, A coil has an inlet temperature of 60°F and outlet of 90°F. If the mean tempeature of the coil is 100°F, find the contact factor of the coil A. 0.60 c.030 B. 052 D.0.40 15, Determine the quantity of water lost by bleed off if the water flow rate over the tower is 30 gpm and the range is 10°F, Percent bleed-off required is 33% A. 0.099 gpm €..0.019 gpm B_ 0.010 gpm 1D. 0.089 gpm Please log-on to wivw.primerevieweenter.com for the enhancement of Elements(Terms) in Mathematics & Basic Engineering Sciences, Power & Industrial Plant Engineering and Machine Design,

You might also like