Govan Catalog 2009

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 86

 about US

Govan Industries Pty Ltd. is a privately owned Electrical Engineering


Company based in Melbourne, Australia. For over 40 years, Govan
Industries have used most advanced technology to manufacture
explosion protection electrical equipment for installation in
hazardous areas.

The Research and Development team at Govan uses computer aided


drafting techniques to produce a full range of Flameproof (Exd),
Increased safety (Exe), Dust excluding ignition proof (DIP) and
Pressurised (Exp) electrical equipments.

To ensure high quality products, Govan has adopted a quality


assurance system to AS/NZS 9001:2000. All products are tested by the
internationally recognised testing stations, to those standards
specified by Standards Association of Australia. The Australian
standards are aligned to those produced by the IEC (International
Electrotechnical Commission) and are similar to American standards.

Govan products are used by all major oil companies in Australia and
are exported to over 20 countries in the Asia-pacific and Middle East
regions.

Govan has a successful heritage in providing state-of-the-art quality


products and services to its clients. Govan’s key objective is to improve
products and processes through an ongoing commitment to research
and development. This has made Govan a successful and reputed
global technology organisation.

Source IEC (281) 882-8300 www.sourceiec.com


 SECTION - 0

SECTION - 1

INDEX
SECTION - 2

SECTION - 3

SECTION - 4

SECTION - 5

SECTION - 6

SECTION - 7

SECTION - 8

SECTION - 9

Source IEC (281) 882-8300 www.sourceiec.com


INTRODUCTION 0-9

Hazardous areas and hazardous area equipment


Classification and general information
Temperature and zone classification
Protection techniques
Ingress protection (IP ratings)
Quick reference guide

EX LIGHTING 1 - 19

Zone 1 and 2 lighting


Fluorescent
High bay
Floodlight
Well glass
Signalling equipment
Vessel light
Dust excluding ignition proof (D.I.P.) lighting

CONTROL STATIONS 2 - 14

Zone 1 Exde modules


Pushbuttons / switches, indicating lights, modules, combination control stations
Increased safety control stations
Exd modules
Flameproof control stations
Dust excluding ignition proof (D.I.P.) control stations

JUNCTION / TERMINAL BOXES 3 - 15

Zone 1 and 2
Increased safety (Exe)
Flameproof (Exd)
Dust excluding ignition proof (D.I.P.)

SIGNALLING AND SPECIAL PURPOSE EQUIPMENT (Exd AND D.I.P.) 4-6

Pressure switches
Limit switches, float switches
Thermostats, security cameras, foot and palm switches
Bell, sail switches

PRESSURISED EQUIPMENT (Exp) 5-6

System and instrument enclosures with windows

CUSTOM BUILT SWITCHBOARDS AND CONTROL STATIONS (Exd) 6-5

Direct on line, reversing and auto star Delta motor


Circuit breaker panels and motor control panels

INTERLOCKED SWITCH RECEPTACLES AND PLUGS (Exd) 7-3

10 amp to 63 amp / 240 V to 415 V pin receptacle and pin plugs

FITTING AND ACCESSORIES 8-5

Adaptors, reducers, nipples, stopping plugs, tees and elbows


Conduit seals, lock nuts

DUST EXCLUDING IGNITION PROOF CONTROL STATIONS AND LIGHTING (D.I.P) 9-6

Control stations
Lighting
Specialised equipment (D.I.P.)
Source IEC (281) 882-8300 www.sourceiec.com
HAZARDOUS AREA EQUIPMENT

Hazardous areas and hazardous area equipment


A hazardous area is defined as an area in which an explosive atmosphere is present, or may be expected
to be present, in quantities such as to require special precautions for the construction, installation and
use of potential ignition sources.
Major industries affected would include oil, gas, petroleum refineries, chemical plants, sewerage
treatment and grain handling. Other industries include spray painting shops, aircraft hangars, petrol
depots, terminals and garages.
Therefore the use of any electrical apparatus in these areas is strictly controlled through various
protection techniques to enable the operators to facilitate the handling or processing of the hazardous
materials. This removes the possibility of ignition being caused by the electrical apparatus contained
within the hazardous area.
Standards Australia prepares, publishes and maintains Australian Standards and in the case of hazardous
areas, looks at all aspects of implementing standards that affect the certification, testing, installation and
maintenance of electrical equipment in these areas.

Note: Australian Standards has endorsed the adoption of the IEC 60079 gases and
vapours and IEC 61241 dust series of standards as joint Australian / New Zealand
Standards. In the new series of standards there is no reference to Class I and Class II
areas. The different zones are identified as zones 0, 1 and 2 for explosive gas
atmospheres and zones 20, 21 and 22 for explosive dust atmospheres.

Conditions required for an explosion


An explosion will only occur when three basic conditions are present:
Explosive material
Oxygen / air
Sources of ignition
Remove any one of these basic conditions and an explosion will
not occur.

IN TEMPERATURE, SPA
ISE RK
AR ,E
TC
.
INF
LAMMABLE SUBS

EXPLOSION
IR

To produce an explosion, three


THE A

elements are required.


N IN

TANC
E
YG

ES
OX

GA
, LI S
QU
ID, D
UST )

0-1

Source IEC (281) 882-8300 www.sourceiec.com


HAZARDOUS AREA EQUIPMENT
Classification of hazardous areas
Explosive gas atmospheres AS 2430.1
Combustible dusts AS/NZS 61241.3 (AS 2430.2)
Specific occupancies AS 2430.3
Group II Flammable gas, vapour or mist Combustible dusts

Zone classification
Zone 0 Continuously hazardous (protection technique allowed)
Exia intrinsic safety
Zone 1 Frequently hazardous (protection technique allowed)
Exib intrinsic safety
Exd flameproof
Exe increased safety
Exp pressured or purged
Exv ventilation
Exs special protection
Zone 2 Infrequently hazardous (protection technique allowed)
Exn Non-sparking
Group II Classification (protection technique allowed)
D.I.P dust - excluding ignition proof:- the new D.I.P standard will
reflect 3 zones for dust areas, zone 20, 21 and 22.

Group II hazardous area zones

Gas/vapour area zones


Zone 2

Zone 0
Zone 1

Zone 1
Zone 1 Dust area zones

Zone 0 Zone 0

Zone 22

Zone 21

Zone 20
0-2

Source IEC (281) 882-8300 www.sourceiec.com


HAZARDOUS AREA EQUIPMENT
The classification of ZONE is a complex problem but the main factors to consider are:
• The probability of the presence of gas
• The quantity and duration of hazardous vapour
• The amount of ventilation
• The nature of gas: lighter or heavier than air

The consequence of an explosion:


The division of plant or parts of plant into zones is generally undertaken by the supervisory authority in
that industry in tandem with process engineers / chemists at the design and or construction stage.

Group classification
Hazardous area equipment is specified in terms of the types of gases present, being:
Group I For mining applications
Group II For general industry
Equipment must be categorised as being suitable for use with gases in Group II industries.
Group I equipment has a representative gas of Methane and all equipment used in underground mining
applications fall into this category. Any other equipment will be Group II classified.
As shown in the table below, Group II is again segmented into three different representative gas groups,
Propane, Ethylene and Hydrogen. Groups IIA, IIB and IIC respectively. The consequence of an explosion:
The division of plant or parts of plant into zones is generally undertaken by the supervisory authority in
that industry in tandem with process engineers / chemists at the design and or construction stage.

Group
Classification Representative Gas
I Methane
IIA Propane
IIB Ethylene
IIC Hydrogen, Acetylene

As stated these are only representative gases where in fact there are many different types of gases one
can be presented with when classifying equipment.

Temperature classification
Temperature Class T1 T2 T3 T4 T5 T6
Maximum surface
temperature (˚C) < 450 < 300 < 200 < 135 < 100 < 85
Minimum ignition
temperature of gas (˚C) > 450 > 300 > 200 > 135 > 100 > 85
Minimum ignition
temperature of dust (˚C) > 500 > 350 > 250 > 185 > 150 > 135

0-3

Source IEC (281) 882-8300 www.sourceiec.com


HAZARDOUS AREA EQUIPMENT
Temperature classification takes into account the ignition temperature of the flammable gases
present in the particular environment.
Ambient temperatures are of course considered in this appraisal, however circumstances which may
increase this surface temperature must also be taken into account.
For example, an enclosure shall over a period of time, collect a layer of dust on its surfaces. This shall
increase the units overall operating and surface temperatures, to a point where if it rises to a point
nearing the flash or combustion point of surrounding gases, liquids or dusts, then an explosive
situation would occur.
For Group I classified electrical equipment, where coal dust can form a layer, the maximum surface
temperature shall not exceed 150 ˚C. If this layer can be avoided thr ough sealing or protection from
the ingress of dust, the inter nal surfaces must not exceed 450 ˚C. In respect to Group II electrical
equipment, temperatures are classified as per the following table.
Temperature classes T1 to T6 (AS 1280.1) are used for all protection techniques, and corr espond to
the electrical devices maximum operational temperature.
The better the equipment, the lower the rated surface temperature. In other words a rating of T4 is
better than that of T2.
Therefore, those items certified as being T6, can be used in T1, T2, T3, T4, T5 and T6 gases. Whereas
a T2 certification only allows a piece of equipment to be used in T1 and T2 gases.

Zone protection techniques


A protection technique is a specific process which negates one of the three components of
combustion.

Group II
Applicable Protection Relevant standard
zone technique Equipment Installation Description
Zones 1 & 2 Exd AS 2380.2 AS 2381.2 Flameproof Enc.
Zones 1 & 2 Exe AS 2380.6 AS 2381.6 Increased safety
Zones 0 - ia Exi AS 2380.7 AS 2381.7 Intrinsic safety
1 - ib
2 - ib
Zones 1 & 2 Exm AS 2431 - Encapsulated app.
Zones 2 Exn AS 2380.9 AS 1076.7 Non-sparking
Zones 1 & 2 Exo IEC 60079-6 - Oil immersion
Zones 1 & 2 Exp AS 2380.4 AS 2380.4 Pressurised
rooms & encl.
Zones 1 & 2 Exq IEC 60079-5 - Sand filled
Zones 0,1 & 2 Exs AS 1826 AS 1076.8 Special protection

Zones 1 & 2 Exv AS 1482 - Ventilation

Zones 20, 21 & 22 D.I.P AS/NZS 61241.3 AS/NZS 61241.3 Dust ignition proof
Zones 20, 21 & 22 Exi AS 2380.7 AS 2381.7 Intrinsic safety
Zones 20, 21 & 22 Exm AS 2431 - Encapsulation
Zones 20, 21 & 22 Exp AS 2380.4 AS 2380.4 Pressurised
rooms & encl.

0-4

Source IEC (281) 882-8300 www.sourceiec.com


Zone protection techniques
The Australian standards are based on Inter national Electrotechnical Commission (IEC) standards and
are similar to Cenelec and British standards in respect of Zone classifications, Gas groups,
Temperature ratings and Testing Methods. This is illustrated in the table below.

ITEMS AUSTRALIA IEC CENELEC USA

Class 1 ZONE ZONE 0 ZONE 0 ZONE 0 DIVISION 1


Classification ZONE 1 ZONE 1 ZONE 1
ZONE 2 ZONE 2 ZONE 2 DIVISION 2

Exd 2380-2 60079 -1 EN50018 UL698


Applicable
Standards Exe 2380-6 60079 - 7 EN50019 -
For Various
Explosion Exn 2380-9 60079 -15 EN50021 CSA22213
Protection Exp 2380-4 60079 -2 EN50016 NPF496
Techniques
Exi 2380-7 60079 -11 EN50020 ANS14913
II A Ammonia, Butane, Propane, Pentane, D Acetone, Propane
Benzene, Acetone, Hexane, Heptane, Ethane, Butane
Iso-octane, Decane, Cyclohexane, Methanol.

Gas Groups and II B Butadiene, Ethylene Oxide, Town Gas, C Acetaldehyde


Representative Coke-oven Gas. Ethylene
Gasses
II C Hydrogen, Acetylene. B Hydrogen, Butadiene
Ethylene oxide

A Acetylene

Max Ignition Temp (oC) Max Ignition Temp (oC)


Temperature Rating
(Limit of Temp. Rise T1 T2 T3 T4 T5 T6 T1 T2 T2A T2B T2C T2D T3
Over Ambient Of
450 300 200 135 100 85 450 300 280 260 230 215 200
40oC)
T3A T3B T3C T4 T4A T5 T6
180 165 160 135 120 100 85

DEGREES OF PROTECTION

Weather Proof IP 54 Nema 3


Water Tight IP 65 Nema 4
Dust Tight IP 66 Nema 4x
Immersion Proof IP 67 Nema 6
Explosion Proof Exd Nema 7
Dust Ignition Proof D.I.P. Nema 9

Note: The information in this catalogue is subject to change and should always be verified against the
current Australian Standard.

0- 5

Source IEC (281) 882-8300 www.sourceiec.com


HAZARDOUS AREA EQUIPMENT
Explosion protection techniques

Exclusion D.I.P Dust-excluding ignition proof


Exm Encapsulation
Exn Non-sparking (hermetically sealed devices, sealed
devices and restricted breathing)
Exp Pressurised enclosure / Rooms
Exq Sand-filled (powder filling)
Explosion containment Exd Flameproof enclosure
Energy limitation Exi Intrinsic safety
Dilution Exv Ventilation
Avoidance of ignition Exe Increased safety
source Exn Non-sparking (inherently non-sparking)

Ex protection techniques

Type of Protection Principle Symbol Typical Application

Power Apparatus, Switchgears, Motors (all


Flame proof
d devices able to ignite flammable mixtures
Enclosure
in normal operations)

Powder Filling q Capacitors, Electronics

Pressurised Power Apparatus (requires special measures


Apparatus P to maintain safety features)

Oil Immersion o Transformers

Measuring and Control Systems (avoiding


Encapsulation m
hot spots on printed boards)

Terminal and Connection boxes, Squirrel


Increased
e cage Motors and Lightning (no incendiary
Safety
or hot surfaces in normal operations)

Terminal and Connection Boxes, Data


Intrinsic Safety i
Processing (small electrical values)

0- 6

Source IEC (281) 882-8300 www.sourceiec.com


INGRESS PROTECTION (IP)
RATINGS TO AS 1939 (IEC 529)
Degree of protection of the enclosures for electrical equipment in accordance with the IEC 529 and EN
60529 standards.

Protection against solid bodies Protection against liquids

Note: 1 The explosion protection certification of the equipment alone does not necessarily mean it
has an adequate degree of protection for specified weather or environment. Hence it is
necessary to check the IP rating of the equipment before selection for a particular
environment.
2 All GOVAN equipment is tested and certified for minimum IP 65 rating.

0-7
Source IEC (281) 882-8300 www.sourceiec.com
QUICK REFERENCE GUIDE
Description Section
Adaptors 8
Break glass alarms 4
Beacons - rotating 1
- flashing 1
Bells 4
Cable glands 8
Conduit fittings - weatherproof 8
Circuit breakers 6
Compound 8
Control stations 9
Pushbuttons 9
Pilot lights 9
Switch 9
Custom built control panels 6
Distribution boards 6
Dust ignition proof junction boxes (D.I.P.) 3
Increased safety junction boxes (Exe) 3
Elbows 8
Enclosures with windows 5, 6
Flameproof junction boxes (Exd) 3
Small round 3
Rectangular 3
Large 3
Screwed cover 3
Float switch 4
Foot and palm switch 4
Fluorescent lights 1
Zone 1
Zone 2 1
Flood lights 1
Zone 1
Zone 2 1
High bay lights - High intensity discharge 1
Zone 1
Zone 2 1
Incandescent lights 1
Instrument enclosures 5
Isolators 2

0-8
Source IEC (281) 882-8300 www.sourceiec.com
QUICK REFERENCE GUIDE
Description Section
Junction boxes 3
Exd 3
Exe & D.I.P. 3
Key switches 2
Lighting 1
Limit switches 4
Motor starters 6
DOL 6
Star/Delta 6
Reversing 6
Meter housing 5
Modules - components 2
Motor control centres 6
Nipples 8
Panelboards 6
Pilot lights 2
Plugs 7
Pressur e switches 4
Pushbutton stations 2
Pressurised systems 5
Receptacles 7
Reducers 8
Switch racks / switchboards 6
Selector switches 2
Sealing fittings 8
Strobe lights 1
Sealing compounds 8
Stopping plugs 8
Sail switch 4
Security camera 4
Tank observation lights 1
Tees 8
Thermostats 4
Unions 8
Vessel lights 1, 4
Weatherproof conduit fittings 8

0-9
Source IEC (281) 882-8300 www.sourceiec.com
SECTION 1
SECTION 1 Ex LIGHTING

HAZARDOUS AREA LIGHTING (Exd, Exn, Exe & D.I.P.)

CAT NO. DESCRIPTION AREA SUITABILITY PAGE NO.

GL2 Exn/D.I.P. fluorescent fixtures Zone 2, 21 and 22 1-2

GL7 Fluorescent luminaries Zone 1 1-3

GL10 Explosion proof well glass Zone 1 and 2 1-4 to 1-5

GL4M Exd Mercury vapour well glass Zone 1 and 2 1-6 to 1-7

GL4H Exd Metal halide well glass Zone 1 and 2 1-6 to 1-7

GL4S Exd HPS well glass Zone 1 and 2 1-6 to 1-7

GL3M Exn/D.I.P. Mercury vapour well glass Zone 2, 21 and 22 1-8 to 1-9

GL3H Exn/D.I.P. Metal halide well glass Zone 2, 21 and 22 1-8 to 1-9

GL3S Exn/D.I.P. HPS well glass Zone 2, 21 and 22 1-8 to 1-9

GL9M Exn Stainless steel mercury vapour fixture Zone 2 1-10 to 1-11

GL9H Exn Stainless steel metal halide fixture Zone 2 1-10 to 1-11

GL9S Exn Stainless steel HPS fixture Zone 2 1-10 to 1-11

GL16M Exd Mercury vapour floodlight Zone 1 and 2 1-12 to 1-13

GL16H Exd Metal halide floodlight Zone 1 and 2 1-12 to 1-13

GL16S Exd HPS floodlight Zone 1 and 2 1-12 to 1-13

GD Exn Titan floodlight Zone 2 1-14 to 1-15

GL5/2M Exn/D.I.P. Mercury vapour floodlight Zone 2, 21 and 22 1-16 to 1-17

GL5/2H Exn/D.I.P. Metal halide floodlight Zone 2, 21 and 22 1-16 to 1-17

GL5/2S Exn/D.I.P. HPS floodlight Zone 2, 21 and 22 1-16 to 1-17

FB1 Exd/D.I.P. Beacon Zone 1, 2, 21 and 22 1-18

FB2 Exd/D.I.P. Beacon - flashing and rotating Zone 1, 2, 21 and 22 1-18

GL10 Exd Vessel light Zone 1 and 2 1-19

1-1 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINAIRE


Non sparking and dust ignition proof (Exn and D.I.P.) ZONE 2

 Features
• Body is produced from non corrosive glass fibre reinforced polyester
• Diffuser is produced from impact proof polycarbonate, textured for improved light Govan Golux 2 series luminaires are for
distribution general purpose lighting, suitable for
outdoor and indoor applications, in Exn
• Retaining clips for diffuser are made from corrosion resistant stainless steel
and D.I.P hazardous locations
• Gear tray is powder coated white and is removed by single action securing locks,
and attached with safety cords for ease of maintenance
• Quality control gear is used to ensure a high running efficiency
• Entry configuration allows through wiring, and on twin tube units an additional
entry at one end, up to M20
• Standard control gear 240 V, 50 Hz. Other voltages on request
• Eye bolt mounting supplied as standard, optional mounting available
• Power factor correction
Dimensions (mm) 
 Specifications
GL2 fluorescent fixture
Classification Degree of protection
IEC 60079-0 IP66
IEC 60079-15
IEC 61241-1-1
Approval Type of protection
Certificate No. IECEx CSA 07.0005X nA, DIP
Ex nA IIC T3 IP66
DIP A21 Ta T4 IP66

 Ordering Information
Dimensions (mm)
Watts Weight A B C D Cat. NO.
2 x 18 2.6 kg 676 398 154 124 GL2-18T
2 x 36 5.5 kg 1276 798 154 124 GL2-36T
2 x 58 6.8 kg 1576 1100 154 124 GL2-58T

 Options
• Add option suffix to catalogue number : -Suffix
• Through wiring (M20 entry each end) : -T
• Ceiling mounting : -C
• Eyebolt hanger mounting : -H
• Pipe mounting (1 - 1/4" pipe) : -P
• Wall mounting (90 degrees) : -W
• Maintained emergency battery pack : -ME
• Non-maintaining emergency battery pack : -NME
• Typical ordering code : GL2-36T-T-C-ME

1-2 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF FLUORESCENT LUMINARIES ZONE 1

The GOLUX 7 SERIES luminaires are for general


purpose lighting suitable for outdoor and indoor
applications, in Exd hazardous locations, ie:
Liquid stores, Spray booths, Chemical plants,
Refineries, Ammunition Depots etc.

 Standards Compliance
Exd : CLASS 1 ZONE 1 TO AS 2380.2
GAS GROUPS : II C
TEMPERATURE : T5, T6
DEGREE : IP66
Exd APPROVAL : AUS Ex 3735

 Features
• Control box and end cap are from a corrosion resistant Aluminium alloy.
• Polycarbonate tube outer case. ( Optional Toughened Glass Tube Outer case)
• Screwed Body arrangement is easily disconnected for lamping of fitting.
• Powder coated mild steel mounting reflector for greater light distribution.
• Standard control gear supply is 240V. 50Hz. Other supplies available on request.
• Entry 2x M20 (Standard)

 Product Selection Chart


Cat. No Watt Weight Dimension L (mm)
GL7-S18 1*18 5.25Kg 1183
GL7-S36 1*36 8.00Kg 1800
GL7-S58 1*58 9.50Kg 2090
GL7-T18 2*18 11.00Kg 1183
GL7-T36 2*36 15.00Kg 1800
GL7-T58 2*58 18.00Kg 2105

OPTION: Emergency light fitting available with 2-hour battery back-up. Other
ratings on request.
Emergency Light Cat No.: GL7-T18-ME (TYP) For maintained emergency.
GL7-T18-NME (TYP) For non-maintained emergency.

1-3 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF WELL GLASS LUMINAIRE


Up to 200 Watt (Exd) ZONE 1

 Features
• The GL 10 series luminaire is a well glass light fitting without control gear suitable
for hazardous area Group II Zone 1 & 2. It can be fitted with lamps up to 200 watt
incandescent, 160 watt self ballasted Mercury Vapour and SL type fluorescent
up to 25 watt
• Stainless steel hardware
• Ribbed body for added strength and better cooling of the light fitting
• One piece silicon gasket for water tight seals
• Variety of mounting arrangements
• Choice of reflectors in polyester
GL10 with polyester dome reflector
• Toughened and tempered heat r esistant glass

 Specifications
GL10 Well glass
Classification Ambient temperature
IEC 60079-0 -20 ˚C to 50 ˚C
IEC 60079-1
Approval Lamp holder
IECEx TSA 07.0004X Porcelain ES or BC
Exd IIB T* IP66
Temp Class : T3-T6
ATEX : Sira 07ATEX1131X
II2G
Degree of protection Terminals
IP 66 Insulated connectors up to 4 sq mm
Housing material Weight
Marine grade corrosion resistant Aluminium alloy - 7 kg
aluminium alloy or cast stainless steel Stainless steel - 15.5 kg
grade 316
Diffuser Cable entry
Impact resistant toughened glass Standard 2 x M20
Reflector Standard finish
Polyester RAL7032 for aluminium alloy fitting
Stainless steel - unpainted
Rated voltage
220-250 V ±10 %, 50 Hz

 Options
1. Luminaire housing from cast stainless steel grade 316.
2. Other voltages and frequencies available.
3. Two coat epoxy paint finish.
4. Other cable entries available as requested.

 Accessories
1. Variety of reflectors.
2. Wire guard for glass globe.
3. Cast aluminium guard.

1-4 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF WELL GLASS LUMINAIRE (Exd)

 O rdering Information
Temp Ceiling Mount Pendant Mount Wall Mount 15˚ Wall Mount
Lamp Type Watts Rating Cat. No. Cat. No. Cat. No. Cat. No.
Incandescent 75 T5 GL10N07C GL10N07P GL10N07W GL10N07AW
Incandescent 1 0 T5 GL10N010C GL10N10P GL10N10W GL10N10AW
Incandescent 150 T5 GL10N015C GL10N15P GL10N15W GL10N15AW
Incandescent 200 T4 GL10N020C GL10N20P GL10N20W GL10N20AW
Self ballasted mercury 100 T5 GL10M10C GL10M10P GL10M10W GL10M10AW
Self ballasted mercury 160 T3 GL10M16C GL10M16P GL10M16W GL10M16AW
Fluorescent SL 18 T6 GL10F18C GL10F18P GL10F18W GL10F18AW
Fluorescent SL 23 T6 GL10F23C GL10F23P GL10F23W GL10F23AW

 Notes Dimensions (mm) 


1. The above catalogue number do not include lamps.
2. Please specify voltage, frequency, lamp holder and cable entry size when
ordering.
3. Optional accessories
A. Wire guard - Code 1.
B. Cats aluminium guard - Code 3. Ceiling Mounting
C. Polyester 300 angle reflector - Code A.
D. Polyester dome reflector - Code D.
4. Add "s" after the catalogue number for cast stainless steel fitting.
Typical example of ordering
GL10N20C-A1
GL10M16P-D3
Gl10F25W-B-S- (Stainless steel)

 Intensity distribution curves Pendant Mounting


(Principal Planes)
GL10 Incandescent floodlight with white 300
polyester dome reflector.
200 w clear incandescent lamp.
Beam efficiency 56%
Beam type Wide/NEMA 7 h x 7 h

 Intensity distribution curves Wall Mounting


(Polar Curves)
GL10 N20 Incandescent fitting with glass dome
lens/polyester dome reflector.
200 w incandescent lamp.
LOR 71%
Peak intensity @ 210 263 cd/1000 lm

15˚ Wall Mounting

1-5 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF WELL GLASS LUMINAIRE


UP to 400 Watt (Exd) ZONE 1

 Features
The GL4 series luminaire is a high intensity discharge (H.I.D.) well glass
fitting suitable for hazardous area Group II Zone 1 & 2. It can be fitted with lamps
up to 400 watt high pressure Sodium, Mer cury Vapour and Metal Halide
Integral control gear
Stainless steel hardware
Hinged cover allows ease for servicing and relamping
One piece silicon gasket for water tight seals
Variety of mounting arrangements
Choice of reflectors in polyester and aluminium
Stanchion mounting bracket allows 10 to 150˚ rotation in vertical plane for setting
light direction
Ideal for use as a symmetrical floodlight with aluminium reflector and yoke arm

 Specifications
GL4 well glass
Classification Rated voltage
Group IIII, Zone 1 & 2, 220-250 V ±10 %, 50 Hz GL4 with aluminium dome reflector
Exd Gas group IIIIA & II B (II
IIIIB + H2), T3
Approval Ambient temperature
AUS Ex 2017 to AS 2380-2 (IEC 60079 -1) -20 ˚C to 50 ˚C
Degree of protection Lamp holder
IP 66 Porcelain E27 or E40
Housing material Terminals
Marine grade corrosion resistant High grade melamine up to 4 sq mm
aluminium alloy or cast stainless steel
grade 316
Diffuser Weight
Impact resistant toughened glass Aluminium alloy - 24 kg
Stainless steel - 37 kg
Reflector Cable entry
Polyester, aluminium Standard 2 x M20
Control gear integral
Standard finish
RAL7032 for aluminium alloy fitting
Stainless steel - unpainted

 Options
1. Luminaire housing from cast stainless steel grade 316.
2. Other voltages and frequencies available.
3. Two coat epoxy paint finish. GL4 with well glass
4. Other cable entries available as requested.

 Accessories
1. Variety of reflectors.
2. Wire guard for glass globe.

1-6 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINAIRE

 Ordering Information
Ceiling Mount Pendant Mount Stanchion Mount Wall Mount
Lamp Type Watts Cat. No. Cat. No. Cat. No. Cat. No.
Mercury vapour 80 GL4M08C GL4M08P GL4M08S GL4M08W
Mercury vapour 125 GL4M12C GL4M12P GL4M12S GL4M12W
Mercury vapour 250 GL4M25C GL4M25P GL4M25S GL4M25W
Mercury vapour 400 GL4M40C GL4M40P GL4M40S GL4M40W
HPS 70 GL4S07C GL4S07P GL4S07S GL4S07W
HPS 150 GL4S15C GL4S15P GL4S15S GL4S15W
HPS 250 GL4S25C GL4S25P GL4S25S GL4S25W
HPS 400 GL4S40C GL4S40P GL4S40S GL4S40W
Metal halide 175 GL4H17C GL4H17P GL4H17S GL4H17W
Metal halide 250 GL4H25C GL4H25P GL4H25S GL4H25W
Metal halide 400 GL4H40C GL4H40P GL4H40S GL4H40W

 Notes Dimensions (mm) 


1. The above catalogue numbers do not include lamps.
2. Please specify voltage, fr equency, and cable entry size when ordering.
3. Optional accessories
A. Wire guard - Code 1. Ceiling
B. Polyester dome reflector - Code D. Mounting
C. Polyester 30˚ angle reflector - Code A.
D. Aluminium high bay reflector - Code C.
4. Add S after the catalogue number for cast 316 stainless steel fitting.
Typical example of ordering
GL4M25W-A1
GL4S4OC-C
GL4H25S-B-S- (Stainless steel)
Wall
 Intensity distribution curves Mounting
(Principal Planes)
GL4 symmetrical floodlight. (AL. reflector & glass
dome)
400 w Mercury Vapour lamp.
Beam efficiency 60%
Beam type Wide/NEMA 6 h x 6 h

 Intensity distribution curves Pendant


Mounting
(Polar Curves)
GL4M40 High bay fitting (AL. reflector & glass dome)
400 w Mercury Vapour lamp.
LOR 63%
Peak intensity @ 20˚ 263 cd/1000 lm

Stanchion
Mounting

1-7 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINAIRE


Up to 400 Watt (Exn and D.I.P.) ZONE 2

 Specifications
Gl3 Well glass
Classification Degree of protection
ExnR Group IIII, Zone 2 to AS 2380.9 IP 66 to AS 1939
D.I.P Group II to AS 2236
Gas group IIC
Approval Temperature class
Certificate No. Ex 967x T2-T3 (up to 250 W with prismatic glass )
D.I.P Certificate AUS Ex 935x T4 ( up to 250 W Reflector/Lens)
T3 (400 W Reflector/Lens)
 Technical Data
Voltage / Frequency 240 V/50 Hz … Other voltages available on request Cat. No. GL3
Wattage Mercury Vapour 50, 80, 125, 250, 400 W
Metal Halide 175, 250, 400 W
High Pressure Sodium 50, 70, 150, 250, 400 W
Power factor 0.85, Integral Ballast Dimensions (mm) 
Weight MV MH HPS
Under 250 W 10 kg 15 kg 11 kg
250W 11 kg 16 kg 12 kg
Ceiling
400 W 12 kg 18 kg 14 kg Mounting
Lamp Holder Porcelain E27 (low wattages) or E40 (high wattages)
Terminal Block High grade Melamine for up to 4 mm2 wire. Insulation grade
105 ˚C up to 250 W, 115 ˚C for 400 W
Cable Entries 2 x M25 conduit standard, M20 optional. (One entry
plugged and available for restricted breathing test of
installation).
Materials High grade cast aluminium body, grey enamel finish.
Silicone rubber seals. Stainless steel external hardware.
Fibreglass reinforced polyester or spun aluminium reflectors. Pendant
Mounting

 Photometrics

Stanchion
Mounting

Without reflector With aluminium highbay reflector


Wall
Mounting

1-8 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINAIRE (Exn AND D.I.P.)

 Ordering Information

 Products with Mercury Vapour Lamp


Ceiling Pendant Stanchion Mount Wall Mount
Mount Mount (25˚,1 1/4" Pipe)
Lamp Watts Cat.No. Cat.No. Cat.No. Cat.No.
50 GL3M05C GL3M05P GL3M05S GL3M05W
80 GL3M08C GL3M08P GL3M08S GL3M08W
125 GL3M12C GL3M12P GL3M12S GL3M12W
250 GL3M25C GL3M25P GL3M25S GL3M25W
400 GL3M40C GL3M40P GL3M40S GL3M40W

 Products with High Pressure Sodium Lamp


Ceiling Pendant Stanchion Mount Wall Mount
Mount Mount (25˚,1 1/4" Pipe)
Lamp Watts Cat.No. Cat.No. Cat.No. Cat.No.
50 GL3S05C GL3S05P GL3S05S GL3S05W
70 GL3S07C GL3S07P GL3S07S GL3S07W
150 GL3S15C GL3S15P GL3S15S GL3S15W
250 GL3S25C GL3S25P GL3S25S GL3S25W
400 GL3S40C GL3S40P GL3S40S GL3S40W

 Products with Metal Halide Lamp


Ceiling Pendant Stanchion Mount Wall Mount
Mount Mount (25˚,1 1/4" Pipe)
Lamp Watts Cat.No. Cat.No. Cat.No. Cat.No.
175 GL3H17C GL3H17P GL3H17S GL3H17W
250 GL3H25C GL3H25P GL3H25S GL3H25W
400 GL3H40C GL3H40P GL3H40S GL3H40W

The above fixtures are fitted with prismatic glass globes as standard up to 250 watt and
refractor glass as standard on 400 watt lights. If guards, reflectors or different optics are
required then the following suffix should be added to the basic code selected above.

Optics alternatives Reflector option for glass globe


Reflector/Lens for 400 W L Polyester, 30˚ angle A
Guard options Aluminium high bay B
Wire guard for glass globe 1 Polyester dome D
Wire guard for reflector/lens 2 Examples: GL3M05C Notes 
Cast guard for glass globe 3
GL3M05C-R 1. Lamps not included as part of
GL3M05C-1A supply unless specifically
requested as a priced option
(code … Y).
2. Specify conduit entry size (default
size is M25).

1-9 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINARIES (Exn)


UP to 400 Watt in stainless steel Zone 2

The GOLUX 9 stainless steel luminaire is a high intensity discharged light fixture for use
with Mercury Vapour, High Pressur e Sodium and Metal Halide lamps up to 400 watt.
The GOLUX9 light fitting is designed for Group II Zone 2 hazardous areas with extreme
corrosive environments.
Typical examples of these types of areas are oil and gas platforms, refineries, wharfs,
jetties and any environments where salt water or salt laden air creates corrosion problems.

 Specifications
GL9 Stainless steel luminaire
Classification Degree of protection
ExnR Group IIII, Zone 2 to AS 2380.9 (IEC 60079-15) IP 66
Gas group IIIIC
Approval Temperature class
Certificate AUS Ex 2035X T2-T4
Voltage/Frequency Power factor
220-250 V, 50 Hz (other voltages available) 0.85 Cat. No. GL9
Wattage Weight
Mercury Vapour … 50, 80, 125, 250, 400 W MV - 11 kg
Metal Halide … 175, 250, 400 W MH - 16 kg
High Pressure Sodium 50, 70, 150, 250, 400 W HPS - 12 kg
Ambient temperature Lamp holder
-20 ˚C to 50 ˚C Porcelain E27 E40
Cable entries Control gear
2 x M25 conduit standard, other sizes Integral
optional. Pendant 1 … 1/4" BSP.

 Features
The fittings housing and covers are produced from 1.5 mm thick 316
grade stainless steel
All securing screws and other hardware used is stainless steel
Control gear is integrally mounted and is easily accessible for maintenance
Factory mounted terminal block for ease of field wiring
One piece silicon gaskets for long lasting water tight seals
Heat resistant clear prismatic glass globe fitted to housing by screwing into a
stainless steel 316 grade retaining ring

1-10 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINAIRES (Exn) ZONE 2

 Ordering Information

 Products with Mercury Vapour Lamp


Ceiling Mount Pendant Mount Stanchion Mount Wall Mount
Lamp Watts Cat.No. Cat.No. Cat.No. Cat.No.
50 GL9M05C GL9M05P GL9M05S GL9M05W
80 GL9M08C GL9M08P GL9M08S GL9M08W
125 GL9M12C GL9M12P GL9M12S GL9M12W
250 GL9M25C GL9M25P GL9M25S GL9M25W
400 GL9M40C GL9M40P GL9M40S GL9M40W

 Products with High Pressure Sodium Lamp


Ceiling Mount Pendant Mount Stanchion Mount Wall Mount
Lamp Watts Cat.No. Cat.No. Cat.No. Cat.No.
50 GL9S05C GL9S05P GL9S05S GL9S05W
70 GL9S07C GL9S07P GL9S07S GL9S07W
150 GL9S15C GL9S15P GL9S15S GL9S15W
250 GL9S25C GL9S25P GL9S25S GL9S25W
400 GL9S40C GL9S40P GL9S40S GL9S40W

 Products with Metal Halide Lamp


Ceiling Mount Pendant Mount Stanchion Mount Wall Mount
Lamp Watts Cat.No. Cat.No. Cat.No. Cat.No.
175 GL9H17C GL9H17P GL9H17S GL9H17W
250 GL9H25C GL9H25P GL9H25S GL9H25W
400 GL9H40C GL9H40P GL9H40S GL9H40W

 Options
Suffix to be added to code
Polyester, 30˚ angle A
Polyester dome D
Wire guard 1
Typical examples of codes:
GL9M12W-A1, GL9S25C-BS

Notes 
1 Lamps not included as part of
supply unless specifically
requested as a priced option.
2 Specify conduit entry size (default
size is M25)

1-11 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF FLOODLIGHT LUMINARIES (Exn)


UP to 600 Watt (Exd) Zone 1

 Features
The GL16 series luminaire is a high intensity discharge (H.I.D) floodlight fitting
suitable for use in hazardous area, Zone 1 and 2. It can be fitted with lamps up to
600 watt high pressur e Sodium or up to 400 watt Mercury Vapour and Metal Halide
Hinged cover for ease of maintenance and relamping
Stainless steel hardware
Yoke mounting allows a 120˚ rotation in the vertical plane for setting light direction
Integral control gear
Variety of mounting arrangements

 Specifications
GL16 Floodlight Diffuser
Classification Degree of protection
Zone 1 & 2 Exd IP 66
Gas group IIIIB + H 2
Approval Housing material
AUS Ex 3660X to AS 2380 -2 (IEC60079 -1) Marine grade corrosion
resistant Aluminium alloy
Cat. No. GL16
Diffuser Reflector
Impact resistant toughened glass High purity anodised
aluminium
Rated voltage Ambient temperature
220-250 V ±10%, 50 Hz -20 ˚C to 50 ˚C
Lamp holder Terminals
Porcelain ES 40 High grade melamine up
to 4 sq mm
Luminaire weight Cable entry
Aluminium - 42 kg without control gear Standard 2 x M25
Control gear
Integral

 Options
1. Other voltages and frequencies available
2. Two coat epoxy paint finish
3. Other cable entries available as requested

 Accessories
1. Pole mounting adaptor
2. Wire guard
3. Deflector / Weather hood

1-12 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF HIGH BAY LUMINAIRES (Exd)

 Ordering Information
Lamp Yoke mount Pole mount Wall mount
type Watts T rating Cat. No. Cat. No. Cat. No.
Metal halide 250 T3 GL16H25Y GL16H25P GL16H25W
Metal halide 400 T2 GL16H40Y GL16H40P GL16H40W
HPS 250 T3 GL16S25Y GL16S25P GL16S25W
HPS 400 T2 GL16S40Y GL16S40P GL16S40W
Mercury vapour 250 T3 GL16M25Y GL16M25P GL16M25W
Mercury vapour 400 T2 GL16M40Y GL16M40P GL16M40W

 Notes Dimensions (mm) 


1. The above catalogue numbers do not include lamps.
2. Please specify voltage, cable entries and mounting when ordering.
3. Optional accessories
A. Wire guard - Code 1 eg. GL16M25Y-1
B. Deflector / Weather hood - Code D eg. GL16M25W-D

 Intensity distribution curves


(Principal Planes)
GL16 floodlight Yoke Mounting
400 W HPS, tubular clear lamp
Beam efficiency 39%
Beam type Wide/NEMAƒ6 h x 5 h

Pole Mounting

Wall Mounting (Refer Yoke Mounting)

1-13 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF FLOODLIGHT (Exn) ZONE 2

 Features
Remote gear (in either Exn or Exd enclosure)
Long life and low maintenance
Adjustable lamp bracket for required aiming angle
Floodlight … Heavy duty die cast, low copper content aluminium body, large
efficient 99.9 % pure non-ageing aluminium reflector. Hot dip
galvanised mounting bracket (or powder coated). Stainless steel
external screws, nuts, bolts and clips
Glass … Toughened safety. High temp. silicon rubber gaskets
Beam types … Narrow (5 x 2), Wide (6 x 6) Cat. No. GD (Titan)
Lamp … Bench tested and supplied with each floodlight
… All lamps are high output HID tubular type
Control gear … Standard reactor type to .85 pfc, supplied separately on a
pre-wired and tested gear tray assembly; or Exn / Exd enclosures
IP Rating … IP 66, Simtars Report No. NE92/0129
Dimensions (mm) 
 Applications
Large area lighting, car park, industrial sites, jetties, tank farms, marshalling yards,
marinas, quays, security areas, wharfs, refineries and petrochemical complexes etc.

 Specifications
GD Floodlight
Classification Degree of protection
ExnR Group II , Zone 2 IP 66
Gas Group IIIIC
Approval Temperature class
Ex 2034X to AS 2380.9 (IEC 60079 -15) T2
Circuit diagram 
 Accessories / Options
GD1185 240 V to 415 V transformer
GD1186 240 V 2 kW lamp and ignitor
GD1190 cast aluminium waterproof gear box
GD1192 louvre, vertical
GD1193 415 V gear and D1190
GD1195 louvre, horizontal

GL9 Stainless steel luminaire


 Ordering Information Classification
Lamp Circuit Amps Circuit Supply Control Gear Beam Weight (kgs)
Watts Type Start Run Watts Volts Location Type Light only Cat. No.
2000 MH 8.2 5.74 2072 415 Remote Narrow 24 GD1100
1000 MH 8 5.3 1050 240 Remote Narrow 24 GD1105
1000 HPS 6.7 5.23 1068 240 Remote Narrow 24 GD1110
2000 MH 8.2 5.74 2072 415 Remote Wide 24 GD1115
1000 MH 8 5.3 1050 240 Remote Wide 24 GD1120
1000 HPS 6.7 5.23 1068 240 Remote Wide 24 GD1125

1-14 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF FLOODLIGHT (Exn)


Photometric Data

 Intensity Distribution Curves


(principal planes)
GD1115 2 kW high capacity floodlight
2000 W Metal Halide tubular lamp
Beam efficiency 80%
Beam type wide … NEMA 6 h x 6 h

 Isolux Contours
(Titan wide beam floodlight)
The isolux contours are standardised in a grid determined by the mounting height (h).
Used as a design tool, the accompanying multi-purpose contours, makes it possible to
estimate the area covered and illuminance levels, based upon the nominated mounting
height/scale related contours for each lamp type.
The position of the maximum Eh value is marked (A) and is 100 %. The isolux contours
B, C, D and E are percentage contours of that maximum.
The curves and effective illuminances are valid only, when the TITAN GD 115 floodlight
is aimed at 65˚ to the downward vertical.

 Illuminance Value at Typical Mounting Heights


Lamp Height Contours / Eh Lux (initials)
Type/ Watts h (ms) A B C D E
Metal Halide 20 50 40 25 15 5
2 kW 15 90 72 45 27 9
10 200 160 100 60 20
Metal Halide 20 21 17 10 6 2
1 kW 15 40 32 20 12 4
10 84 67 42 25 8
High Pressur e 20 40 32 20 12 4
Sodium 15 68 54 34 20 7
1 kW 10 156 124 78 46 15

1-15 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 1 Ex LIGHTING

EXPLOSION PROOF WELL FLOODLIGHT


UP to 400 Watt (Exn and D.I.P.) ZONE 2

 Golux 5/2 (GL5/2)


The Golux 5 series Exn and D.I.P. luminaries are versatile, rugged and economical high
intensity discharge floodlight fixtures. Supplied complete with integral control gear for
use with Mercury Vapour, Metal Halide and High Pressure Sodium lamps up to 400
watt, all factory installed and fully tested with lamp as supplied. Packed complete and
ready to install.

 Features
Both body and cover are made of heavy duty one-piece pressure die cast low copper
content aluminium or stainless steel fabricated fitting type GL5
Hinged cover for ease of access to integral ballast and capacitor
Thermal shock and impact resistant glass lens
Gaskets are of heavy duty, high temperatur e silicon rubber GL5/2 Flood Light Fitting
Porcelain heavy duty ES40 socket with spring loaded centre contact and brass nickel
plated double lamp grip screw shell
High grade dimpled, pure aluminium reflector
Different mounting options available

1-16 Source IEC (281) 882-8300 www.sourceiec.com


Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
SECTION 2 CONTROL STATIONS AND MODULES

POLYESTER AND STAINLESS STEEL CONTROL STATIONS (Exde)

 Multiple Operators

 Ordering Information
Polyester Stainless steel
Description Cat. No. Cat. No.
3 Pushbutton 1 N/O + 1 N/C engraved to suit EP2315-1-1-1 ES2315-1-1-1
1 Mushroom head 1 N/O + 1 N/C
Emergency stop button twist to reset
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-3 ES2315-1-1-3
1 Mushroom head 1 N/O + 1 N/C
Emergency stop key to reset
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-4 ES2315-1-1-4 Cat. No. ES2315-1-1-1-1-1-1
1 Mushroom head 1 N/O + 1 N/C stop button
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-8 ES2315-1-1-8
1 LED pilot light 24, 48, 110, 240 V AC/DC
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-11 ES2315-1-1-11
1 Selector switch OFF/ON + 2 N/O
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-201 ES2315-1-1-201
1 Meter 48 mm
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-ME-1-1 ES2315-ME-1-1
1 Meter 48 mm
1 Selector switch OFF/ON
2 N/O EP2315-ME-201 ES2315-ME-201

Note: Other combinations available on request

Cat. No. EP2315-1-8-201

2-5 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

PUSHBUTTON MODULES (Exd)


Flameproof electrical equipment for explosive atmospheres

 Specifications
MN Push button modules
Classification
Temperature rating
Group II Zone 1 and 2 T6
Gas Group II B
II B+H2 also available
D.I.P. Zones 21 and 22
Approvals Degree of protection
For use in certified Exd Enclosures IP 66 protection to AS 1939
Exd to AS 2380.1
Aus Ex 1268U
Current ratings Rated voltage
3 Amps 240 V standard Pushbutton - Key operated
Cat. No. MN05
other voltages available
Electrical components Standard finish
1 N/C or N/C Anodised aluminium
OPTION: 2 Additional Contacts available

Pushbutton - Pull to reset - Padlockable


Cat. No. MN06

Pushbutton - Recessed actuator elease Pushbutton - Mushroom head


Cat. No. MN01 Cat. No. MN03 Cat. No. MN08

Pushbutton - Projection actuator eset


Cat. No. MN02 Cat. No. MN04 Cat. No. MN08-A

2-6 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

SWITCH MODULES (Exd)


Flameproof electrical equipment for explosive atmospheres

 Specifications
Lamp type pilot light No. 11 module
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas Group IIIIB
IIIIB+H 2 also available
D.I.P. Zones 21 and 22
Approvals Degree of protection
For use in Certified Exd enclosures IP 66 protection to AS 1939
Exd to AS 2380.1
Aus Ex 1268U

Standard finish Standard voltage


Aluminium 240 VAC/ 415 VAC, 24 VDC
When ordering nominate volts required and colour. Standard colours: red, green, amber.

 Specifications
CA10 Switch modules
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas Group IIIIB
IIIIB+H 2 also available
Approvals Degree of protection
For use in Certified Exd enclosures IP 66 protection to AS 1939
Exd to AS 2380.1 Cat. No. MNS0
Aus Ex 1268U

Ratings Standard finish


Volts - TBA; Amps -TBA Aluminium
Note : Select type of switch from Page 2-14

 Specifications
CA20B - C42 Switch modules
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas Group IIIIB
IIIIB+H 2 also available
Approvals Degree of protection
For use in Certified Exd enclosures IP 66 protection to AS 1939
Exd to AS 2380.1
Aus Ex 1268U Cat. No. MNS1

Ratings Standard finish


Volts - TBA; Amps -TBA Aluminium

Note : Select type of switch from Page 2-14

2-7 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

CONTROL STATIONS WITH COMBINATIONS OF MODULES (Exd)


Flameproof electrical equipment for explosive atmospheres

 Specifications
FC4 Control stations
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
Cat. No. FC4
II 2 G D
Standard entries Weight
2xM20 1.9 kg

 Ordering Information
Step 1: Select Cat. No. of basic configuration from table A e.g. 1PB/SW/1PL = FC4H
Step 2: Select type of switch from table B e.g. 2 pole isolator = 201
Step 3: Select pushbutton from table C e.g. mushroom head turn to reset = 3
Step 4: Select type, colour and voltage of pilot light from table D e.g. Incandescent
240 V blue = FC4-H-201-3-9 blue

Table A Cat. No.


Combinations of up to four modules

No. of Pushbuttons No. of Switches No. of Pilot lights


2 1 FC4E
1 1 FC4F
1 2 FC4G
1 1 1 FC4H
1 1 FC4L
2 1 FC4M
1 2 FC4N
Any combinations of 4 Any combinations of 4 FC4Z

Note: For all combinations contact your local branch office.

2-8 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

COMBINATIONS OF CONTROL STATIONS WITH MODULES (Exd), FLAME


PROOF ELECTRICAL EQUIPMENT FOR EXPLOSIVE ATMOSPHERES

Table B - Switches

Code Rating Poles Description


201 240 / 20 A 2 Isolator
210 240 / 20 A 1 Change over with off
220 240 / 20 A 1 Change over without off
176 240 / 20 A 1 Start stop
178 240 / 20 A 1 Start stop off
203 415 / 20 A 4 Isolator
211 415 / 20 A 2 Changeover with off
221 415 / 20 A 2 Changeover without off

Table C - Pushbuttons

Code Description
1 Pushbutton recessed actuator
2 Pushbutton projecting actuator
3 Pushbutton mushroom head twist to reset
4 Pushbutton mushroom head key to r eset
5 Key operated pushbutton
6 Pushbutton mushroom head pull to reset padlockable
8 Pushbutton mushroom head

Table D - Pilot lights

Code Description
9 Incandescent 12 V / 240 V
11 7 x LED - nominate colour and voltage
Colours - red, green, amber, blue, white.

Combinations of more than four modules


The following table is an indication of the number of each module that can be installed in
Govan enclosures. Eg. the F7 enclosure can have seven pushbuttons, seven pilot lights,
four CA10 switches, two CA20B switches or combinations of modules. Where required,
enclosures can be joined together.

Pushbuttons Pilot lights CA10 Switches CA20B Switches .


Cat. No
7 7 4 2 F7
9 9 9 9 F22
12 12 12 12 F35
15 15 10 8 F42
24 24 24 24 F150
36 36 36 TBA F560

2-9 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

SINGLE PUSHBUTTON STATIONS (Exd)


Flameproof electrical equipment for explosive atmospheres

 Specifications
FWI Pushbutton stations
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Degree of protection
IECEx TSA 07.0005X IP66
Exd IIB T6 IP66
ATEX : Sira 07ATEX1132X
II 2G
Standard entries Weight
2 x M20 1.1 kg
Rated
240 V, 3 A

 Ordering Information
Description Cat. No.
Pushbutton recessed actuator FWI-1
Pushbutton projecting actuator FWI-2
Pushbutton mushroom head twist to reset FWI-3
Pushbutton mushroom head key to r eset FWI-4
Key operated pushbutton FWI-5
Pushbutton mushroom head pull to reset padlockable FWI-6
Pushbutton mushroom head FWI-8

 Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Standard entries Weight
2xM20 1.7 kg

 Ordering Information
Description Cat. No.
Pushbutton recessed actuator FC4I-1
Pushbutton projecting actuator FC4I-2
Pushbutton mushroom head twist to reset FC4I-3
Pushbutton mushroom head key to r eset FC4I-4
Key operated pushbutton FC4I-5
Pushbutton mushroom head pull to reset padlockable FC4I-6
Pushbutton mushroom head FC4I-8

2-10 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

MULTIPLE OPERATOR PUSHBUTTON STATIONS (Exd)


Flameproof electrical equipment for explosive atmospheres

 Specifications
FC4J Pushbutton stations
Classification
Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
Cat. NO. FC4
II 2 G D
Standard entries Weight
FC4J - 2 x M20 FC4J - 1.7 kg
FC4K - 2 x M25 FC4K - 1.8 kg

 Multiple Operators
 Ordering Information
Description Cat. No.
1 x pushbutton recessed actuator
1 x pushbutton recessed actuator FC4J-1-1
1 x pushbutton recessed actuator
1 x pushbutton projecting actuator FC4J-1-2
1 x pushbutton recessed actuator
1 x pushbutton mushroom head twist to reset FC4J-1-3
1 x pushbutton recessed actuator
1 x pushbutton mushroom head key to reset FC4J-1-4
1 x pushbutton recessed actuator
1 x key operated pushbutton FC4J-1-5
1 x pushbutton recessed actuator
1 x pushbutton mushroom head pull to reset padlockable FC4J-1-6
1 x pushbutton recessed actuator
1 x pushbutton mushroom head FC4J-1-8

3 x pushbutton recessed actuator FC4K-1-1-1


1 x pushbutton recessed actuator
2 x pushbutton projecting actuator FC4K-1-2-2
1 x pushbutton recessed actuator
2 x pushbutton mushroom head twist to reset FC4K-1-3-3
1 x pushbutton recessed actuator
2 x pushbutton mushroom head key to reset FC4K-1-4-4
1 x pushbutton recessed actuator
2 x key operated pushbuttons FC4K-1-5-5
1 x pushbutton recessed actuator
2 x pushbutton mushroom head pull to reset padlockable FC4K-1-6-6
1 x pushbutton recessed actuator
2 x pushbutton mushroom head FC4K-1-8-8

2-11 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

PILOT LIGHT STATION (Exd)


Flameproof electrical equipment for explosive atmospheres

 Specifications
Pilot light stations
Classification Temperature rating
T6
IEC 60079-0
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Cat. No. FC4O-11
Standard voltage
240 V
Standard colours: red, green, white, amber

 Ordering Information
Description Standard Entries Weight (kg) Cat. No.
1 x (7 x LED) type pilot light; colour
and voltage to be nominated 2 x M20 1.5 FC4O-11

 Ordering Information
Description Standard Entries Weight (kg) Cat. No.
2 x (7 x LED) pilot lights: colour
and voltage to be nominated 2 x M20 1.6 FC4P-11

2-12 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

SINGLE GANG SWITCHES (Exd)


Flame proof electrical equipment for explosive atmospheres

 Specifications
Single gang switches
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 60079-0
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X (FC4) IP66
Exd IIC T6 IP66
Ex td A21 IP66
ATEX: Sira 07ATEX1133X amp isolator
II 2 G D
IECEx TSA 07.0005X (FW)
Exd IIB T6 IP66
ATEX: Sira 07ATEX1132X
II 2 G
Standard entries Weight
4 x M 20 - FW and FC4A series 1 kg - FW series
4 x M 25 - FC4B and FC4C series 1.7 kg - FC4A series
2 x M 32 - FC4U and FC4V series 2.9 kg - FC4B series
Material
Marine grade aluminium
Stainless steel hardware

Cat. No. FC4A 203-415, 4 pole, 20


amps isolator
 Ordering Information
Current Rating No. of Poles Description Electrical components e style Cat. No.
240 V 20 A ACI 2 Isolator A201 CA10 FW201
240 V 20 A ACI 1 Changeover with off A210 CA10 FW210
240 V 20 A ACI 1 Changeover without off A220 CA10 FW220
415 V 20 A ACI 4 Isolator A203 CA10 4 FC4A203
415 V 20 A ACI 2 Changeover with off A211 CA10 4 FC4A211
415 V 20 A ACI 2 Changeover without off A221 CA10 4 FC4A221
415 V 20 A ACI 3 Changeover with off A212 CA10 4 FC4A212
415 V 20 A ACI 3 Changeover without off A222 CA10 4 FC4A222
415 V 20 A ACI 3 Reversing A401 CA10 4 FC4A401
415 V 20 A ACI 4 Changeover with off A213 CA10 7 FC4A213
415 V 20 A ACI 4 Changeover without off A223 CA10 7 FC4A223
415 V 32 A ACI 4 Isolator A203 C26 4 FC4C203
415 V 40 A ACI 4 Isolator A203 C32 7 FC4U203
415 V 55 A ACI 4 Isolator A203 C42 7 FC4V203
Notes: 1. Special control switches, spring return, multi position available on r equest.
2. Control switches with gold plated contacts available on r equest.
3. Switches with barriers between power and control contacts available on
request.
4. Combination of switches wired to terminal blocks available on request.

2-13 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 2 CONTROL STATIONS AND MODULES

FLAMEPROOF CONTROL STATION AND MODULES (Exd)


FC4 Range of combinations

 Ordering Information
Description Cat. No.
CA10 switch FC4A
Sail switch FC4A - SS
Float switch FC4A - FS
CA20B switch FC4B
C26 switch FC4C
Switch (CA10 to C26) + 1 pushbutton FC4D
Switch (CA10) + 2 pushbuttons FC4E
Switch (CA10 to C26) + 1 pilot light FC4F
Switch (CA10) + 2 pilot lights FC4G
Switch (CA10) + 1 pushbutton + 1 pilot light FC4H
Break glass alarm station FC4I - Q
Single pushbutton FC4I
6" bell 25 V DC or 240 V AC FC4I -BE6
2 pushbuttons FC4J
3 pushbuttons FC4K
1 pushbutton + 1 pilot light FC4L
2 pushbuttons + 1 pilot light FC4M
1 pushbutton +2 pilots FC4N
1 pilot light FC4O
2 pilot lights FC4P
Q break glass alarm station (REF to FC4I) FC4Q
3 pilot lights FC4R
2 x switches (CA10) FC4S
Thermostat FC4T
Thermostat / 2.5 kW element FC4TC
C32 switch (style 7 only) FC4U
C42 switch (style 7 only) FC4V
Email single phase motor sentinel FC4W
Combination of 4 pushbuttons (style 6 only) FC4X
Combination of pushbuttons and pilot lights (style 6 only) FC4Z

Modules for (Exd) flameproof enclosure Cat No.


Recessed actuator MN01
Projecting actuator MN02
Mushroom head twist to release (emergency stop) MN03
Mushroom head press in key to reset (emergency stop) MN04
Key operated pushbutton MN05
Mushroom head push in pull to reset padlockable (emergency stop) MN06
Module blanking plug (used for spares) MN07
Mushroom actuator (non latching) MN08
Large mushroom head black actuator (non latching) MN08A
240 V LED pilot light (other voltages available) MN11
Potentiometer MN13

2-14 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3
SECTION 3 JUNCTION/TERMINAL BOXES

INCREASED SAFETY AND GUST IGNITION PROOF JUNCTION BOXES


(Exe AND D.I.P.)

CA . NO. DESCRIPTION AREA SUITABILITY PAGE NO.

EP and DP range Glassfibre reinforced polyester Zone 1, 2, 21 and 22 3-2

ES and DS range Stainless steel 316 Zone 1, 2, 21 and 22 3-3

GE range Sheet steel and stainless steel Zone 1 and 2 3-3 to 3-4

DE range Aluminium Zone 1, 2, 21 and 22 3-5 to 3-6

FLAME PROOF ALUMINIUM JUNCTION BOXES (Exd )

FW Flame proof junction boxes in aluminium Zone 1 and 2 3-7

FC4 Flame proof junction boxes in aluminium Zone 1 and 2 3-7

FC4/5 Flame proof junction boxes in aluminium Zone 1 and 2 3-8

FC15 Flame proof junction boxes in aluminium Zone 1 and 2 3-8

F7 Flame proof junction boxes in aluminium Zone 1 and 2 3-9

F22 Flame proof junction boxes in aluminium Zone 1 and 2 3-9

F35 Flame proof junction boxes in aluminium Zone 1 and 2 3-10

F42 Flame proof junction boxes in aluminium Zone 1 and 2 3-10

F150 Flame proof junction boxes in aluminium Zone 1 and 2 3-11

F160 Flame proof junction boxes in aluminium Zone 1 and 2 3-12

F400 Flame proof junction boxes in aluminium Zone 1 and 2 3-12

F560 Flame proof junction boxes in aluminium Zone 1 and 2 3-13

F24 Flame proof junction boxes in aluminium Zone 1 and 2 3-13

- Quick selection chart - 3-14 to 3-15

3-1 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

INCREASED SAFETY AND DUST IGNITION PROOF


JUNCTION BOXES (Exe AND D.I.P.)

 EP and DP polyester enclosures

 Specifications
Classification Temperature class
Group II Zone 1, 2, 21 and 22 T6
Gas group IIIIC
Approvals Degree of protection
AS 2380-6 IP 66 to AS 1939
Standards Aus. Cert. non flammable
AUS Ex 2441X - EP1511,EP2315
Material Strength
Cat. No. EP2315
Glass reinforced polyester Impact resistant 7 Nm wall
thickness 3.5 mm minimum
Hinges Gaskets
For PE30315 and PE60300 Neoprene rubber

 Dimensions (mm)

Cat. No. EP6030

 Ordering Information and dimensions (mm)


Enclosure Maximum number of terminals Maximum number of entries
Cat. No. A B C 2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 Side M20 M25 M32 M40 M50 Weight
EP1511 119 154 87 12 10 8 6 - Short 2 2 1 - - 1.25 kg
DP1511 Long 3 2 2 - -
EP2315 150 230 117 25 22 18 15 12 Short 4 3 2 1 1 2 kg
DP2315 Long 6 5 3 2 2
EP3030 311 300 170 64 60 50 40 20 All 8 8 4 3 2 -
DP3030
EP6030 300 600 170 128 120 100 80 40 Short 8 8 4 3 2 -
DP6030 Long 16 16 8 5 4

3-2 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

INCREASED SAFETY AND DUST IGNITION PROOF JUNCTION


BOXES (Exe AND D.I.P.)

 ES and DS stainless steel enclosures


Specifications
 Classification Temperature rating
Group II Zone 1, 2, 21 and 22 T6
Gas group IIC
Approvals Degree of protection
AS 2380.1, 6 AS 1939 IP 66 to AS 1939
IEC 60079 -7
Standards Aus.Cert. IEC 60079 - 7
Aus Ex 2484x
Material Gaskets
316L stainless steel Neoprene rubber
Rated voltage Rated current
600 V AC To be advised
Cable entries
To be advised

 Ordering Information / dimensions (mm)


Height Width Depth
Cat. No. (mm) (mm) (mm) Weight
ES1110 120 100 70 1.00 kg
DS1110
ES1511 150 120 78 1.5 kg
DS1511
ES2315 230 150 115 2.5 kg
DS2315 Cat. No. ES 1511

 Ordering Information and dimensions (mm)


Enclosure Maximum number of terminals Maximum number of entries
2 2 2 2 2
Cat. No. A B C 2.5 mm 4 mm 6 mm 10 mm 16 mm Side M20 M25 M32 M40 M50 Weight
ES1110 100 120 70 6 5 4 - - Short 2 2 1 - - 1Kg
DS1110 Long 2 2 1 - -
ES1511 119 154 87 12 10 8 6 - Short 2 2 1 - - 1.25 KG
DS1511 Long 3 2 1 - -
ES2315 150 230 117 25 22 18 15 12 Short 4 3 2 1 1 2KG
DS2315 Long 6 5 3 2 2

3-3 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

INCREASED SAFETY JUNCTION BOXES (Exe)

 GE sheet metal / stainless steel enclosures

 Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIC
Approvals Degree of protection
Cat. No. GE33
SAA Cert. No. AUS Ex 869X for IP67
GE33, GE45 and GE56
Material Gaskets
Sheet metal / Stainless steel Neoprene rubber
Gland plates Hinges
1 or 3 2 pin type or bracket type

 Dimensions (mm)

Cat. No. GE56

Ordering Information and dimensions (mm)


Enclosure Maximum number of terminals Maximum number of entries
Cat. No. A B C D 2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 Side 20 mm 25 mm 32 mm 40 mm 50 mm Weight
G E33 300 300 200 325 45 38 25 32 20 All 17 14 8 6 3 9.0 kg
Short 26 20 12 10 4
G E45 400 500 200 425 120 110 90 70 60 14.5 kg
Long 32 26 14 12 5
Short 32 26 14 12 5
G E56 500 600 200 530 180 150 120 100 90 Long 40 32 18 16 7 18.5 kg

3-4 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

INCREASED SAFETY AND DUST IGNITION PROOF


JUNCTION BOXES (EXE AND D.I.P)

 DE Aluminium junction boxes


The DE range of junction boxes are certified by Standards Australia for installation in
Group II hazardous gas and dust areas. They are also suitable for heavy duty industrial
use both indoor and outdoor.

 Specifications
Classification Temperature rating
Zone 1, 2, 21 and 22 T6
Gas group of IIIIC
Approval Degree of protection
D.I.P. - AS2236 DE1…IP65, DE2…IP 66,
Standards Australia Certificates DE3…IP 66, DE4…IP 66
DE1 AUS Ex 699, DE2 Ex 1173X,
DE3 Ex 1176X, DE4 Ex 3277X

Exe - Exe to AS 2380.6


DE1 Ex 751, DE2 Ex 1180X
DE3 Ex 1184X, DE4 Ex 3278X
Rated voltage Standard finish
415 V Cast from CP601 marine grade aluminium
Cover fixing Gasket
Stainless steel hexagon screws Neoprene

 Ordering Information
Maximum No. of terminals
2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 Weight Cat No. Cat. No. DE2
12 … … … … 1.3 kg DE1-2
… 10 … … … 1.3 kg DE1-4
24 … … … … 4 DE2-
k
… 20 … … … 4 k
DE2-
… … 18 … … 4.2 kg DE2-
… … … 15 … 4.3 kg DE2-1
… … … … 12 4.3 kg DE2-1
64 … … … … 9.5 kg DE3-2
… 60 … … … 9.5 kg DE3-4
… … 50 … … 9.5 kg DE3-6
… … … 40 … 9.4 kg DE3-10
… … … … 20 9.5 kg DE3-16
160 150 125 104 86 18.5 kg DE4

Note: Other terminal sizes or combinations of terminals available on request

3-5 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

INCREASED SAFETY AND DUST IGNITION PROOF JUNCTION BOXES


(Exe and D.I.P.)

Maximum No. of entries per side


Enclosure M20 M25 M32 M40 M50 Cat. No.
Short side 1 1 … … …
DE1
Long side 2 2 1 … …
All sides 4 3 2 2 1 DE2
All sides 8 6 4 3 2 DE3
Short side 10 8 6 4 3
DE4
Long side 20 16 12 8 6

Note: Other threads available on request. Combination of entries available on request.

 Specifications
DE Range (Aluminium)

DE1
Approx. weight - 1.3 kg

DE2
Approx. weight - 4 kg

DE3
Approx. weight - 9.5 kg

DE4
Approx. weight - 18.5 kg

3-6 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

FLAME PROOF JUNCTION BOXES (Exd)

 FW Junction Boxes
 Specifications
Classification Temperature rating
IEC 60079- 0 T6
IEC 60079-1
Approvals Degree of protection
IECEx TSA 07.0005X IP66
Exd IIB T6 IP66
ATEX: Sira 07ATEX1132X
II 2 G
Weight Material
600 g Aluminium / stainless steel hardware
Accessories
4 way terminal blocks

Layout Entry Size No. Entries Cat. No. Dimensions (mm) 


M 20 2 FW22I
M 20 2 FW22L
M 20 3 FW23T
M 20 4 FW24X
M 20 5 FW25
M 25 2 FW32I
M 25 2 FW32L
M 25 3 FW33T
M 25 4 FW34X
M 25 5 FW35
 FC4 Junction Boxes
 Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Weight Material
1.1 kg Aluminium / stainless steel hardware

Layout Entry Size No. Entries Cat. No.


M 20 2 FC4 22I
Dimensions (mm) 
M 20 2 FC4 22L
M 20 3 FC4 23T
M 20 4 FC4 24X
M 25 2 FC4 32I
M 25 2 FC4 32L
M 25 3 FC4 33T
M 25 4 FC4 34X

3-7 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

FLAME PROOF JUNCTION BOXES (Exd)

 FC4/5 Junction Boxes


 Specifications
Classification Temperature rating
IEC 60079- 0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX : Sira 07ATEX1133X
II 2 G D Cat. No. FC4/5

Standard finish Weight


Cast Iron / Aluminium / Stainless 8 kg / 2.6 kg Dimensions (mm) 
steel hardware
Maximum No. of Entries
M16 M 20 M 25 M 32 M 40 M 50
Top 4 4 3 2 1 1
Bottom 4 4 3 2 1 1
Sides 2 2 2 1 - -
Back 1 1 1 1 - -

 FC15 Junction Boxes


 Specifications
Classification Temperature rating
Exd Group II Zones 1 and 2 T6
Gas group IIB

Approvals Degree of protection


Exd to AS 2380.2 IP 66 to AS 1939
Cert No. Aus EX 1260

FC15 Govan Junction box


Standard finish Weight
Aluminium / Stainless steel hardware FC 15D - 4.2 kg Dimensions (mm) 
FC 15 - 3.5 kg
Maximum No. of Entries
Cat. No. M 20 M 25 M 32
Top 2 2 -
Bottom 2 2 2

3-8 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

FLAME PROOF JUNCTION BOXES (Exd)

 F35 Junction Boxes


The F35 is made from standard or marine grade aluminium and comes complete with
stainless steel hardwar e. Fixing is by means of two zinc plated steel straps. Entries are
possible in the top and bottom only in standard junction boxes. Special side filled boxes
with entries on all sides are possible on r equest.

 Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIIIB Cat. No. F35
II B+H2 also available
Approvals Degree of protection
Dimensions (mm) 
Exd to AS 2380.2 IP 66 to AS 1939
Cert. No. Aus Ex 853
Weight
15.5 kg
Maximum No. of entries per side
Entry location M 20 M 25 M 32 M 40 M 50
Top & bottom only for
standard junction boxes 11 9 6 4 2
1
Maximum No. of entries per side )
Entry location 1
/2 " 3
/4" 1" 1-1 /4 " 1-1 /2 " 2"
Top & bottom only for
standard junction boxes 11 9 6 4 2 1
Note: 1) All are NPT threads

 F42 Junction Boxes


 Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIIIB
II B+H2 also available
Approvals Degree of protection
Exd to AS 2380.2 IP 66 to AS 1939
Cert. No. Aus Ex 3607
Material
Cat. No. F42
Cast aluminium / Stainless steel hardware

Maximum No. of entries per side


Dimensions (mm) 
Entry size Long Side (Qty) Short side (Qty) Standard centres
M20 24 12 40 mm
M25 15 8 50 mm
M32 10 6 60 mm
M40 8 4 70 mm
M50 4 2 88 mm
M63 3 1 105 mm

3-10 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

FLAME PROOF JUNCTION BOXES (Exd)

 F160 Junction Boxes


The F160 is made from standard or marine grade aluminium and comes complete with
stainless steel hardware. Fixing is by means of four feet cast the enclosure. Entries are
possible on all sides.
 Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Degree of protection
IECEx TSA 07.0040 IP 66
F160-* Exd IIB T6 IP66
FH160-* Exd IIB+Hydrogen T6 IP66
ATEX: Sira 07ATEX1136X
II 2 G Dimensions (mm) 
Weight Standard finish
37 kg/ 90 kg Aluminium/Cast Iron/ Stainless Steel
hardware
Maximum No. of entries per side
Entry location M 20 M 25 M 32 M 40 M50
Long side 26 18 12 8 6
Short side 12 8 6 5 3

1
Maximum No. of entries per side )
Entry location 1
/2 " /4"
3
1" 1-1 /4 " 1-1 /2 " 1-3 /4 " 2"
Long side 26 18 12 8 6 6 4
Short side 12 8 6 5 3 3 2
Note: 1) All are NPT threads

 F400 Junction Boxes


 Specifications
Approval Degree of protection
IECEx SIM 07.0005X IP66
Exd IIB+Hydrogen T6 IP66
IEC 60079-0
IEC 60079-1
ATEX: Sira 07ATEX1138X
II 2 G
Weight Internal dimensions Cat. No. F400
60 kg 507 x 305 x 206 mm
Material Dimensions (mm) 
Aluminium/Stainless steel hardware
Maximum No. of entries per side
Standard Centres 40 mm 50 mm 60 mm 70 mm 88 mm 105 mm
Long side 34 28 14 12 8 6
Short side 20 17 9 7 5 3
Entry size M20 M25 M32 M40 M50 M63

3-12 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

FLAME PROOF JUNCTION BOXES (Exd)

 F560 Junction Boxes


The F560 is made from standard or marine grade aluminium and comes complete with
stainless steel hardware. Fixing is by means of four feet cast into the enclosure. Entries
are possible on all sides.

 Specifications
Classification Temperature rating
IEC 60079- 0 T6
IEC 60079-1
Approval Degree of protection
IECEx SIM 07.0002X IP66 Cat. No. F560
F560 - Ex d IIB T6 IP66
FH560 - Ex d IIB+Hydrogen T6 IP 66
ATEX : Sira 07ATEX1137X
Dimensions (mm) 
II 2 G
Weight Standard Finish.
54 kg/153 kg Aluminum/Cast Iron/ Stainless Steel
hardware

Maximum No. of entries per side


Entry location M 20 M 25 M 32 M 40 M 50 M 63
Long side 31 29 12 10 6 5
Short side 26 24 10 7 5 4
1
Maximum No. of entries per side )
Entry location 1
/2 " 3
/4 " 1" 1- 1/ 4 " 1- 1/ 2 " 1"
Long side 31 29 12 10 6 4
Short side 26 24 10 7 5 4

Note: 1) All are NPT threads

 F24 Junction Boxes


The F24 is made from standard or marine grade aluminium and comes complete with
stainless steel hardware. Entries are possible on all sides.

 Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIIIB Cat. No. F24
IIIIB+H2 also available
Approvals Degree of protection Dimensions (mm) 
Exd to AS 2380.2 IP 66 to AAS 1939
Cert. No. Aus Ex 837
Weight Internal dimensions
85 kg 698 x 394 x 101 mm

3-13 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

QUICK SELECTION CHART FOR FLAME PROOF ENCLOSURES (Exd)

Quick reference guide to Govan flame proof and D.I.P. enclosures


Dimensions in millimetres (approximate only)

P/buttons
Internal dimensions Overall dimensions Classification Klippon P/light Switch
Cat. No. H x W x D (mm) H x W x D (mm) Entries Cover Exd D.I.P. terminal modules modules
FW 64 dia x 41 114 dia x 60 All sides Flat & dome X 1 x BK4 1 1
FJ1 64 dia x 41 114 dia x 60 All sides Dome screw on X 1 x BK4 Nil Nil
FC4 104 dia x 60 152 dia x 80 All sides Flat & dome X X 10 x SAK2.5 4 2
FC4/5 110 dia x 80 160 x 170 x 100 All sides Flat & dome X 12 x SAK2.5 4 2
DE1 120 x 78 x 50 172 x 85 x 70 All sides Flat Exe X 15 x SAK2.5 2 1
DE2 178 x 178 x 128 200 x 200 x 152 All sides Flat Exe X 24 x SAK2.5 9 9
DE3 246 x 246 x 128 300 x 300 x 160 All sides Flat Exe X 64 x SAK2.5 16 16
DE4 680 x 300 x 128 738 x 350 x 160 All sides Flat X X 160 x SAK2.5 40 40
FC15 150 dia x 75 210 dia x 110 Top & bottom Flat X X 20 x SAK2.5 7 4
F7 170 x 170 x 120 210 x 210 x 156 All sides Flat X X 20 x SAK2.5 7 4
F7D 170 x 170 x 177 210 x 210 x 213 All sides Dome X X 43 x SAK2.5 4 4
F22 228 x 177 x 150 295 x 245 x 200 Top & bottom Flat X 33 x SAK2.5 9 9
F35 304 x 228 x 150 370 x 295 x 200 Top & bottom Flat X 50 x SAK2.5 12 12
F150 411 x 279 x 160 490 x 358 x 208 All sides Flat X 150 x SAK2.5 24 24
F160 411 x 279 x 230 490 x 358 x 275 All sides Dome X 150 x SAK2.5 4 4
F42 362 x 207 x 154 400 x 245 x 196 All sides Flat
F400 507 x 305 x 206 570 x 368 x 255 All sides Flat X 200 x SAK2.5 TBA TBA
F24/2 698 x 394 x 190 775 x 470 x 280 All sides Dome X 400 x SAK2.5 TBA TBA
F560 525 x 425 x 170 600 x 500 x 224 All sides Dome X 160 x SAK2.5 36 36

Flame proof junction boxes


How to order
Step 1. Select enclosures from Quick Reference Chart above
Step 2. Select entry type from Table A below
Step 3. Check enclosur e in catalogue if the number of entries required is permissible
Step 4. Select entry arrangement fr om Table B on page 3-15

Table A
0 1 2 3 4 5 6 7
Metric = (M) - 16 20 25 32 40 50 63
BSP = (P)
1
/2" - 3
/ 4" 1" 1 1/4" 1 1/2" 2" -
NPT = (T) 1
/2" - 3
/ 4" 1" 1 1/4" 1 1/2" 2" -
Conduit = (C) - 5
/8" 3
/ 4" 1" 1 /4"1
1 /2"
1
2" 2 / 2"
1

3-14 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 3 JUNCTION/TERMINAL BOXES

QUICK SELECTION CHART FOR FLAMEPROOF ENCLOSURES (Exd)

Table B
When ordering please specify type of wiring method, eg. conduit - pyrotenax -
gland, etc.

F7 M3 5 23

Enclosure Metric 25 mm Entry arrangement

5 entries
(Refer page 3-9)

3-15 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 4 SIGNALLING AND SPECIAL PURPOSE EQUIPMENT

Flameproof electrical equipment for explosive atmospheres

 Specifications
F7PS pressure switches
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx TSA 07.0029 IP 66
Ex d IIB T6 IP66
Ex tD A21 T80 0C IP66
ATEX: Sira 07ATEX1134
II 2 G D Cat. No. F7PS
Standard finish Current rating
Aluminium Volts and amps to be advised
Dimensions Internal dimensions
210 x 210 mm F7A2D = 115 mm deep Dimensions (mm) 
F7A2DD = 155 mm deep
F7PS = 205 mm deep

Note: When ordering, nominate pressur e range

 Specifications
FWI-Q Break glass alarm
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Degree of protection
IECEx. TSA 07.0005X IP 66
ATEX : Sira 07ATEX1132X
Exd IIB T6 IP66
Current rating Weight
240V,3A 1.9 kg.
Standard Finish Dimensions
Aluminium 114x 114x 143
= mm

Catalogue number
FWI-Q

4-2 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 4 SIGNALLING AND SPECIAL PURPOSE EQUIPMENT

Flame proof electrical equipment for explosive atmospheres

 Specifications
FC4 Limit switch
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Degree of protection
IECEx TSA 07.0005X IP 66
Ex d IIB T6 IP66
ATEX: Sira 07ATEX1132
II 2 G D
Current rating Weight
240 V, 5 A 1.8 kg Cat. No. FW1 - LP
Standard finish Dimensions
Aluminium 114 x 136 x 60 mm
Catalogue number 
FW1 - LP
FW1 - LR

 Specifications
FC4FT Foot & palm switch Dimensions (mm) 
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1 o 152
IEC 61241-0 o 7. 130
IEC 61241-1
2 HOLES G O VA N
Approvals Current rating
IECEx SIM 07.0001X 240 V, 3 A
Exd IIC T6 IP66
56

Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Standard finish Weight
Aluminium 1.5 kg 166
Dimensions Catalogue number
153 x 153 x 160 mm FC4FT

Note: See page 3-7 for mounting dimensions for FC4.


o 94

4-4 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 4 SIGNALLING AND SPECIAL PURPOSE EQUIPMENT

FLAMEPROOF ELECTRICAL EQUIPMENT FOR EXPLOSIVE


ATMOSPHERES

 F7PD security camera


The F7PD is made from standard marine grade aluminium and comes complete with
stainless steel hardware. Fixing is by means of four feet casts into enclosure. Entries
possible on all sides.

 Applications
Refineries/petrochemical complexes, boundary monitoring, security for petrochemicals,
defence stores and continuous area monitoring etc.

 Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0 Cat. No. F7PD
IEC 61241-1
Approvals Degree of protection
IECEx TSA 07.0029 IP 66
Ex d IIB T6 IP66
0
Weight Ex tD A21 T80 C IP66
ATEX: Sira 074ATEX1134
II 2 G D
Weight Catalogue number
10 kg F7PD

Cat. No. FB2

4-6 Source IEC (281) 882-8300 www.sourceiec.com


Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
Source IEC (281) 882-8300 www.sourceiec.com
SECTION 6 CUSTOM BUILT SWITCHBOARDS/MOTOR STARTERS

CIRCUIT BREAKERS (Exd)


Flame proof electrical equipment for explosive atmospheres

 Specifications
FCB Circuit breakers
Classification Degree of protection Temperature rating
Zone 1 and 2 IP 66 T6
Gas Group II B
Approvals
Exd protection to IECEx TSA 06.0054 (F150 & FH150)
AS 2380, Aus Ex 460X ATEX: Sira 07ATEX1135X
IECEx TSA 07.0029 (F7) II 2 G
ATEX: Sira 07ATEX1134
II 2 G D
Current rating Ordering information
415/240 V, 6/100 A / 225 Cat. No. FCB/no.breakers/no.
of poles
Standard finish Dimensions
Aluminium Please refer to section 3 Current
Enclosure Poles Breakers kA (Amp) Cat. No.
 Ordering information FC15D 2 1 6 6-40 FCB2
FC15D 2 2 6 6-40 FCB22
No. of kA FC15D 3 1 6 6-40 FCB3
Poles rating FC15D 4 1 6 6-40 FCB4
F22 3 2 6 6 - 100 FCB23
1. FCB kA
F35 4 2 6 6 - 100 FCB24
No. of Current F22 2 3 6 6 - 100 FCB32
Breakers rating F35 3 3 6 6 - 100 FCB33
F6 4 3 6 6 - 100 FCB34
F6 2 4 6 6 - 100 FCB42
2. Combination of different kA incoming and outgoing breaker F6 4 3 6 6 - 100 FCB43
Incoming Outgoing No. Outgoing F150 4 4 6 6 - 100 FCB44
Current rating of Breakers Current rating F6 2 5 6 6 - 100 FCB52
F150 3 5 6 6 - 100 FCB53
kA
Current
kA Enclosure Poles Breakers kA (Amp) Cat. No.
Incoming Incoming No. of
Poles kA Poles rating F6 2 6 6 10 - 100 FCB62
F150 2 7 6 10 - 100 FCB72
3 Cir cuit breakers available with earth leakage relay and shunt F150 2 8 6 10 - 100 FCB82
trip on r equest.
FC15D 2 1 6 10-40 FCB2EL
4 For a greater number of breakers and distribution boards,
FC15D 2 2 6 10-40 FCB22EL
more than one enclosure is joined together by compound
bush. F22 3 1 6 10-13 FCB3EL
5 Custom built distribution boards with a combination of F22 4 1 6 10-13 FCB4EL
isolators and circuit breakers is available. F22 3 1 18 10-63 FCB3-63
F22 4 1 18 10-63 FCB4-63
F35 3 1 18 10 - 100 FCB3-100
F35 4 1 18 10 - 100 FCB4-100
F35 3 1 18 10 - 125 FCB3-125
F35 4 1 18 10 - 125 FCB4-125
F150 3 1 18 10 - 160 FCB3-160
F150 4 1 18 10 - 175 FCB4-175
F150 3 1 18 10 - 200 FCB3-200
F150 4 1 18 10 - 200 FCB4-200

6-3 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 6 CUSTOM BUILT SWITCHBOARDS/MOTOR STARTERS

CUSTOM BUILT CONTROL STATIONS & SWITCHBOARDS (Exd)


Flame proof electrical equipment for explosive atmospheres


Control stations / switchboards are suitable for hazardous area Group II Zone
1, Gas group IIA, and IIB+H2

F22 Control Panel

Dimensions (mm) 

F6 Control Panel

F150 Control Panel

6-4 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 6 CUSTOM BUILT SWITCHBOARDS/MOTOR STARTERS

CUSTOM BUILT CONTROL STATIONS & SWITCHBOARDS (Exd)


Flameproof electrical equipment for explosive atmospheres

 By adding the (Exd) modules in section 2 to the enclosures in section 3, numerous


combinations are available. Our technical staff are at your service and can provide design
information and drawing to meet your requirements. Flameproof control stations/
switchboards can be supplied wired, ready to install.

Typical - Free-Standing Switchboard

F150 Control Panel

Dimensions (mm) 

F24/4 Control Panel

6-5 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 7
SECTION 7 INTERLOCKED SWITCH RECEPTACLES/PLUG

CAT. NO. DESCRIPTION AREA SUITABILITY PAGE NO.

FRT 1 15 Amp, 240 V, 3 or 4 pin plug Zone 1 and 2 7-2

FRT2 20 Amp, 415 V, 3 or 4 pin plug Zone 1 and 2 7-2

FRT3 32 Amp, 415 V, 3, 4 or 5 pin plug Zone 1 and 2 7-2

FRT4 40 Amp, 415 V, 4 or 5 pin plug Zone 1 and 2 7-2

FRT5 63 Amp, 415 V, 4 or 5 pin plug Zone 1 and 2 7-2

FP103 10 Amp, 240 V power outlet Zone 1 and 2 7-3

FP153 15 Amp, 240 V power outlet Zone 1 and 2 7-3

FP203 20 Amp, 240 V power outlet Zone 1 and 2 7-3

FP104 10 Amp, 415 V power outlet Zone 1 and 2 7-3

FP154 15 Amp, 415 V power outlet Zone 1 and 2 7-3

FP204 20 Amp, 415 V power outlet Zone 1 and 2 7-3

FP324 32 Amp, 415 V power outlet Zone 1 and 2 7-3

FP325 32 Amp, 415 V power outlet Zone 1 and 2 7-3

FP404 40 Amp, 415 V power outlet Zone 1 and 2 7-3

FP405 40 Amp, 415 power outlet Zone 1 and 2 7-3

FP634 63 Amp, 415 V power outlet Zone 1 and 2 7-3

FP635 63 Amp, 415 V power outlet Zone 1 and 2 7-3

7-1 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 7 INTERLOCKED SWITCH RECEPTACLES/PLUG

POWER OUTLET PLUG TOPS (Exd)


Flameproof electrical equipment for explosive atmospheres

 FRT Flame proof plugs


For use with suitable portable equipment in hazardous locations where gas groups IIA
and IIB exit. Positive and safe, interlocking with switch receptacle. Cannot be withdrawn
unless switch is at "OFF" position. Earth terminal is first to make and last to break,
ensuring full protection.

 Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Cat. No. FRT1
Approvals Weight
IECEx TSA 06.0020 1.1 kg
ATEX : Sira 07ATEX1139
II 2 G Dimensions (mm) 
Standard finish Dimensions
Plated brass 59 x 59 x 124 mm

 Ordering Information
Gland Entry
Volts Amps Pins Sizes Cat. No.
240 / 250 10 / 15 / 20 3 20 mm FRT1-3 / FRT2-3
415 / 440 10 / 15 / 20 4 25 mm FRT1-4 / FRT2-4
415 / 440 32 3/4/5 25 mm FRT3-3 / FRT3-4 / FRT3-5
415 / 440 40 4/5 32 mm FRT4-4 / FRT4-5
415 / 440 63 4/5 32 mm FRT5-4 / FRT5-5

Cat. No. FRT5

Dimensions (mm) 

7-2 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 7 INTERLOCKED SWITCH RECEPTACLES/PLUG

POWER OUTLET (Exd)


Flame proof electrical equipment for explosive atmospheres

 FP Power outlet
The Govan power outlet has a fully interlocking switch mechanism. Switching is
achieved by the insertion and rotation of the plug. The plug cannot be withdrawn
when the switch is on and cannot be switched on unless the plug is fully inserted.
Having an internally operated switch the FP type outlet especially suitable for harsh
environments.
 Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Weight
IECEx TSA 06.0020 4.5 kg
Ex d IIB T6 IP66
IP44 When socket & plug engaged
ATEX: Sira 07ATEX1139
II 2 G
Degree of protection Entry
IP 66 M25
Volts, Current rating Standard finish
415 / 240 V, 16 / 63 A Aluminium

The FP power outlets are manufactured from corrosion resistant marine grade aluminium
and use stainless steel hardwar e.

 O rdering Information
Outlet Code Amps Volts Pins Plug Code
FP 103 10 240 3 FRT1-3
FP 153 15 240 3 FRT1-3
FP 203 20 240 3 FRT2-3
FP 104 10 415 4 FRT1-4
FP 154 15 415 4 FRT1-4
FP 204 20 415 4 FRT2-4
FP 324 32 415 4 FRT3-4
FP 325 32 415 5 FRT3-5
FP 404 40 415 4 FRT4-4
FP 405 40 415 5 FRT4-5
FP 634 63 415 4 FRT5-4
FP 635 63 415 5 FRT5-5

7-3 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 8
SECTION 8 FITTINGS AND ACCESSORIES

FLAME PROOF AND NON-FLAME PROOF FITTINGS AND


ACCESSORIES

CAT. NO. DESCRIPTION AREA SUITABILITY PAGE NO.

FAMC Adaptors … Metric to conduit Zone 1 8-2

FAPM Adaptors … BSP to metric Zone 1 8-2

FAMT Adaptors … Metric to NPT Zone 1 8-2

FAMT Adaptors … NPT to metric Zone 1 8-2

FSMM Conduit seals … Metric Zone 1 8-3

FSPM Conduit seals … BSP to metric Zone 1 8-3

FHNM Nipples … Metric Zone 1 8-4

FHNT Nipples …NPT Zone 1 8-4

FRMM Reducers … Metric Zone 1 8-4

FRTM Reducers … NPT to metric Zone 1 8-4

FSM Stopping plugs … Metric Zone 1 8-5

FST Stopping plugs … NPT Zone 1 8-5

DSM Stopping plugs … Nylon Zone 1 8-5

DLM Lock nuts … Nylon Zone 1 8-5

FT2/FT3 Tees … Metric Zone 1 8-5

FL2/FL3 Elbows … Metric Zone 1 8-5

8-1 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 8 FITTINGS AND ACCESSORIES

ADAPTORS
Flameproof accessories for explosive atmospheres

 FA Adaptors
 External to Internal
Size Conduit to Metric Cat.No.
3/4" 20 mm FACM 2-2
1" 25 mm FACM 3-3
1 1/4" 32 mm FACM 4-4
1 1/2" 40 mm FACM 5-5
Cat. No. FAMC_
2" 50 mm FACM 6-6

Size BSP to Metric Cat.No. Approvals


1/2" 20 mm FAPM 0-2 IECEx CSA 06.0008U
3/4" 25 mm FAPM 2-3 ATEX: Sira 07ATEX1140U
II 2 G D
1" 32 mm FAPM 3-4 Type of Protection: Ex d IIC, DIP A21
1 1/4" 40 mm FAPM 4-5
1 1/2" 50 mm FAPM 5-6
Classification
IEC 60079-0
Size Metric to NPT Cat.No. IEC 60079-1
20 mm 1
/ 2" FAMT 2-0 IEC 61241-1-1
25 mm 3
/ 4" FAMT 3-2
32 mm 1" FAMT 4-3
40 mm 1 1/ 4" FAMT 5-4
50 mm 1 1/ 2" FAMT 6-5

Size NPT to Metric Cat.No.


1/2" 20 mm FATM 0-2
3/4" 25 mm FATM 2-3
1" 32 mm FATM 3-4
1 1/4" 40 mm FATM 4-5
1 1/2" 50 mm FATM 5-6

8-2 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 8 FITTINGS AND ACCESSORIES

SEALING FITTINGS
Flame proof accessories for explosive atmospheres

 FSMM Conduit Seals


Metric Internal
Conduit Size Cat.No.
20 mm 20 mm FSMM 2-2
25 mm 25 mm FSMM 3-3
32 mm 32 mm FSMM 4-4
40 mm 40 mm FSMM 5-5
50 mm 50 mm FSMM 6-6
63 mm 63 mm FSMM 7-7
Cat. No. FSMM_
Note: Other combinations are available to order. NPT threads have similar catalogue
numbers, e.g. FSTT1-1 etc. Made from aluminium castings.

 FSPM Conduit Seals


Internal
BSP Metric Cat.No.
1
/2" 20 mm FSPM 0-2
3
/4" 25 mm FSPM 2-3
1" 32 mm FSPM 3-4
1 /4"1
40 mm FSPM 4-5
1 1/2" 50 mm FSPM 5-6
2" 63 mm FSPM6-7
3
/4" 20 mm FSPM 2-2
1" 25 mm FSPM 3-3
1- 1/4" 32 mm FSPM 4-4
1- 1/2" 40 mm FSPM 5-5
2" 50 mm FSPM 6-6

Approval No. ANZEx.07.3045


Note: BSP entry at bottom in all cases.

Sealing Compound
o
Type SC2. 3M Scotch N 4 Electrical Resin

8-3 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 8 FITTINGS AND ACCESSORIES

NIPPLES AND REDUCERS


Flameproof accessories for explosive atmospheres

 FHN Nipples
Size Metric Cat. No.
20 mm 20 - 20 FHNM2
25 mm 25 - 25 FHNM3
32 mm 32 - 32 FHNM4
40 mm 40 - 40 FHNM5
50 mm 50 - 50 FHNM6
63 mm 63 - 63 FHNM7 Cat. No. FHNM_

Size Metric Cat. No.


/ 2"
1 1
/2"-1/2" FHNT0
/ 4"
3 3
/4"-3/4" FHNT2
1" 1"-1" FHNT3
1 /41 1 / 4"-1 /4"
1 1 FHNT4
11/2 1 1/2"-11/2" FHNT5
2 2"-2" FHNT6

Sealing Compound

 FR Reducers
External to Internal
Size Metric Cat. No.
20 mm 16 mm FRMM 2-1
25 mm 20 mm FRMM 3-2 Cat. No. FRMM_
32 mm 25 mm FRMM 4-3
Approvals
40 mm 32 mm FRMM 5-4
IECEx CSA 06.0008U
50 mm 40 mm FRMM 6-5 ATEX: Sira 07ATEX1140U
63 mm 50 mm FRMM 7-6 II 2 G D
NPT to metric
Type of Protection: Ex d IIC, DIP A21
Size Metric Cat. No.
/ 4"
3
20 mm FRTM 2-2 Classification
1" 25 mm FRTM 3-3 IEC 60079-0
1 1/ 4" 32 mm FRTM 4-4 IEC 60079-1
IEC 61241-1-1
1 / 2"
1
40 mm FRTM 5-5
2" 50 mm FRTM 6-6

Note: All nipples and reducers are manufactured from brass. Other combinations are
available.

8-4 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 8 FITTINGS AND ACCESSORIES

STOPPING PLUGS, LOCK NUTS, TEES AND ELBOWS


Flameproof accessories for explosive atmospheres

 FSM and FST Stopping plugs - Brass

Size Metric Cat. No.


16 mm FSM1
20 mm FSM2
25 mm FSM3
32 mm FSM4
40 mm FSM5
50 mm FSM6
63 mm FSM7
Size NPT Cat. No. Cat. No. FSM_
1
/2 FST0
3
/4 FST2 Approvals
1" FST3 IECEx CSA 06.008U
1 1/4 FST4
Type of Protection: Ex d IIC, DIP A21
1 1/2 FST5
2" FST6
 DSM Stopping plugs - Nylon Classification
Size Metric Cat. No. IEC 60079-0
IEC 60079-1
20 mm DSM2
IEC 61241-1-1
25 mm DSM3 ATEX: Sira 07ATEX1104U
32 mm DSM4 II 2 G D
40 mm DSM5
50 mm DSM6
63 mm
75 mm
DSM7
DSM8
Dimensions (mm) 
Note: Certification for Exe, D.I.P. Approval No. Aus Ex 2476U 47.5
 DLM Lock nuts - Nylon
Size Metric Cat. No.
20 mm DLM2
25 mm DLM3

O35
32 mm DLM4
40 mm DLM5
47.5

50 mm DLM6
63 mm DLM7
75 mm DLM8
Note: Optional Materials: Aluminium, S. Steel, Brass (Nickel Plate)
O35
 FT Tees 1 )
Size Cat. No.
20 mm FT2
25 mm FT3
1/2" BSP FTP0 40
3/4" BSP FTP 2
 FL Elbows 1)
Size Cat. No.
O41

20 mm FL2
25 mm FL3
1/2" BSP FLP0
3/4" BSP FLP 2
Note: 1) Made from Aluminium. Approval No. ANZEx. 07.3045 Cat. No. FL_

8-5 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 9
SECTION 9 DUST IGNITION PROOF EQUIPMENT

CONTROL STATIONS AND LIGHTING (D.I.P)

CAT. NO. DESCRIPTION PAGE NO.

CONTROL STATIONS

DP DP range - Polyester 9-2

DS DS range - Stainless steel 9-2

DE DE range 9-3

FC4 FC4 range 9-4 to 9-5

F7 F7 range 9-4

FC15 FC15 range 9-4

FC4 D.I.P. specialised equipment 9-5

LIGHTING

GL2D GL2 fluorescent lighting 9-6

GL3D GL3 H.I.D. high bay lighting 9-6

GL5/2 GL5 H.I.D. floodlight 9-6

FB1 FB1 range 9-6

FB2 FB2 range 9-6

9-1 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 9 DUST IGNITION PROOF EQUIPMENT

DUST IGNITION PROOF EQUIPMENT (D.I.P)


Control Stations type DP (GRP) and DS (Stainless Steel)

 Specifications
Classification Degree of protection
Certified for D.I.P. T6 Zones 21 & 22 IP 65/66
Approvals Rated voltage
Cert. of conform Aus Ex 2441X 240 V AC
Standards Aus. AS 2236
AS 1939
Int. standards IEC 61241
Complete range of stainless steel
Rated current Cable entries and polyester control stations
3A Control stations 2 x 20 mm (not threaded)
Materials
Glass reinforced polyester (GRP) Impact resistant to 7nM
Surface resistant to 109 OHMS UV stabilised
Flame retardant / self extinguishing Captive stainless cover screws
Stainless steel earth continuity
plate optional

Note: Custom built D.I.P. Control Stations are available

 Specifications
DS and DP Stainless steel control stations
Certification Temperature rating
DP range
Certified for D.I.P. Zones 21 & 22 T6
Approvals Degree of protection
Cert. of conform Aus Ex 2484X IP 65/IP 66
Standards Aus. AS 2236
Int. standards IEC 61241
Rated voltage Rated current
240 V AC 3A
Cable entries Materials
2 x 20 mm 316L stainless steel

 Ordering Information
Dimensions (mm)
H W D Weight (kg) Cat. No.
150 110 78 0.05 DP1511 DS range

230 150 115 1.25 DP2315


300 300 150 3.5 DP3030
600 300 150 5 DP6030

120 100 70 1 DS1110


150 120 78 1.5 DS1511
230 150 115 2.5 DS2315

9-2 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 9 FITTINGS AND ACCESSORIES

DUST IGNITION PROOF EQUIPMENT (D.I.P)


Control Station - DE Range (Aluminium)

 Specifications
DE control stations
Classification Degree of protection
Group II IP 65
D.I.P. AS 2236, Zone 21, 22 Cat. No. DE1I
Approvals Materials
AUS Ex 699 (DE1)
AUS Ex 1173X (DE2)
AUS Ex 1176X (DE3)
AUS Ex 3277X (DE4)
Standards: AS/NZS61241 IEC 61241
Rated voltage Cable entries
TBA TBA
Note: Custom built Group II D.I.P. control stations are available using enclosure types Cat. No. DE10
DE2, DE3 & DE4, or a combination of enclosures.

 O rdering information
Refer
Cat. No. Description Section
DE1I Single pushbutton station 2 and 3
DE10 Single pilot light station 2 and 3
DEJ1 Twin pushbutton station 2 and 3
DE1P Twin pilot light station 2 and 3
DE1A201 Single gang switch 2 pole 2 and 3 Cat. No. DEJ1
DE1A203 Single gang switch 4 pole 2 and 3

Cat. No. DE1A201

Other types
available

9-3 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 9 FITTINGS AND ACCESSORIES

DUST IGNITION PROOF EQUIPMENT (D.I.P)


Control Stations

 Specifications
FC4, and F7D control stations
Classification Degree of protection
IEC 60079-0 IP 66
IEC 60079-1
IEC 61241-0
IEC 61241-1

Approvals Materials
IECEx SIM 07.0001X (FC4) Cat. No. FC4
Exd IIC T6 IP66
Ex tD A21 IP66
IECEx TSA 07.0029 (F7)
Ex d IIB T6 IP66
Ex tD A21 T80 0C IP66
ATEX: Sira 07ATEX1133X (FC4)
II 2 G D
ATEX: Sira 07ATEX1134 (F7)
II 2 G D

Rated voltage Cable entries


TBA TBA
Note: Select enclosures complete with pushbuttons and selector switch modules as
well as pilot lights. See section 2 of catalogue.

Cat. No. FC4A203


For ordering details contact Govan Industries Pvt. Ltd.

Cat. No. F7D

9-4 Source IEC (281) 882-8300 www.sourceiec.com


SECTION 9 FITTINGS AND ACCESSORIES

DUST IGNITION PROOF EQUIPMENT (D.I.P)


Specialised Equipment

 Specifications
Specialised equipment
Classification Degree of protection
IEC 60079-0 IP 66
IEC 60079-1
IEC 61241-0
Cat. No. FC4-T
IEC 61241-1
Approvals Materials o 152
IECEx SIM 07.0001X Marine grade aluminium o 7. 130
Exd IIC T6 IP66
2 HOLES
Ex tD A21 IP66 G O VA N

ATEX: Sira 07ATEX1133X


II 2 G D

56
Cable entries
TBA

O rdering information
166

Refer
Cat. No. Description Section Page No.

o 94
FC4FT Foot / palm stop switch 4 4-4
FC4-T Thermostat 4 4-5
FC4SS Sail switch 4 4-5 Cat. No. FC4FT
FC41BE6 Bell 4 4-3
FC4A-FS Float switch 4 4-3

Cat. No. FC41-BE6

9-5 Source IEC (281) 882-8300 www.sourceiec.com


Cat. No. FC4AFS
SECTION 9 DUST IGNITION PROOF EQUIPMENT

DUST IGNITION PROOF EQUIPMENT (D.I.P)


Lighting

 Specifications
Classification
Group II D.I.P. Zone 21, 22
Approvals
Subject to housing type
Standards: AS 2236 IEC 61241
Degree of protection
IP 65/66
Cable entries (see ordering information)
Material (see ordering information)

 O rdering information
Refer Cat. No. FB1
Cat. No. Description Section Page No.
GL2D Fluorescent lighting 1 1-8
GL3D H.I.D. High bay lighting 1 1-16/1-17
GL5/2 H.I.D. Floodlight 1 1-20/1-21
FB1/FB1S Strobes 1 1-22
FB2 Beacon / Strobe 1 1-22

Cat. No. FB1S

Cat. No. GL2 Cat. No. GL5/2

Cat. No. FB2

Cat. No. GL2

9-6 Source IEC (281) 882-8300 www.sourceiec.com

You might also like