Professional Documents
Culture Documents
Govan Catalog 2009
Govan Catalog 2009
Govan Catalog 2009
Govan products are used by all major oil companies in Australia and
are exported to over 20 countries in the Asia-pacific and Middle East
regions.
SECTION - 1
INDEX
SECTION - 2
SECTION - 3
SECTION - 4
SECTION - 5
SECTION - 6
SECTION - 7
SECTION - 8
SECTION - 9
EX LIGHTING 1 - 19
CONTROL STATIONS 2 - 14
Zone 1 and 2
Increased safety (Exe)
Flameproof (Exd)
Dust excluding ignition proof (D.I.P.)
Pressure switches
Limit switches, float switches
Thermostats, security cameras, foot and palm switches
Bell, sail switches
DUST EXCLUDING IGNITION PROOF CONTROL STATIONS AND LIGHTING (D.I.P) 9-6
Control stations
Lighting
Specialised equipment (D.I.P.)
Source IEC (281) 882-8300 www.sourceiec.com
HAZARDOUS AREA EQUIPMENT
Note: Australian Standards has endorsed the adoption of the IEC 60079 gases and
vapours and IEC 61241 dust series of standards as joint Australian / New Zealand
Standards. In the new series of standards there is no reference to Class I and Class II
areas. The different zones are identified as zones 0, 1 and 2 for explosive gas
atmospheres and zones 20, 21 and 22 for explosive dust atmospheres.
IN TEMPERATURE, SPA
ISE RK
AR ,E
TC
.
INF
LAMMABLE SUBS
EXPLOSION
IR
TANC
E
YG
ES
OX
GA
, LI S
QU
ID, D
UST )
0-1
Zone classification
Zone 0 Continuously hazardous (protection technique allowed)
Exia intrinsic safety
Zone 1 Frequently hazardous (protection technique allowed)
Exib intrinsic safety
Exd flameproof
Exe increased safety
Exp pressured or purged
Exv ventilation
Exs special protection
Zone 2 Infrequently hazardous (protection technique allowed)
Exn Non-sparking
Group II Classification (protection technique allowed)
D.I.P dust - excluding ignition proof:- the new D.I.P standard will
reflect 3 zones for dust areas, zone 20, 21 and 22.
Zone 0
Zone 1
Zone 1
Zone 1 Dust area zones
Zone 0 Zone 0
Zone 22
Zone 21
Zone 20
0-2
Group classification
Hazardous area equipment is specified in terms of the types of gases present, being:
Group I For mining applications
Group II For general industry
Equipment must be categorised as being suitable for use with gases in Group II industries.
Group I equipment has a representative gas of Methane and all equipment used in underground mining
applications fall into this category. Any other equipment will be Group II classified.
As shown in the table below, Group II is again segmented into three different representative gas groups,
Propane, Ethylene and Hydrogen. Groups IIA, IIB and IIC respectively. The consequence of an explosion:
The division of plant or parts of plant into zones is generally undertaken by the supervisory authority in
that industry in tandem with process engineers / chemists at the design and or construction stage.
Group
Classification Representative Gas
I Methane
IIA Propane
IIB Ethylene
IIC Hydrogen, Acetylene
As stated these are only representative gases where in fact there are many different types of gases one
can be presented with when classifying equipment.
Temperature classification
Temperature Class T1 T2 T3 T4 T5 T6
Maximum surface
temperature (˚C) < 450 < 300 < 200 < 135 < 100 < 85
Minimum ignition
temperature of gas (˚C) > 450 > 300 > 200 > 135 > 100 > 85
Minimum ignition
temperature of dust (˚C) > 500 > 350 > 250 > 185 > 150 > 135
0-3
Group II
Applicable Protection Relevant standard
zone technique Equipment Installation Description
Zones 1 & 2 Exd AS 2380.2 AS 2381.2 Flameproof Enc.
Zones 1 & 2 Exe AS 2380.6 AS 2381.6 Increased safety
Zones 0 - ia Exi AS 2380.7 AS 2381.7 Intrinsic safety
1 - ib
2 - ib
Zones 1 & 2 Exm AS 2431 - Encapsulated app.
Zones 2 Exn AS 2380.9 AS 1076.7 Non-sparking
Zones 1 & 2 Exo IEC 60079-6 - Oil immersion
Zones 1 & 2 Exp AS 2380.4 AS 2380.4 Pressurised
rooms & encl.
Zones 1 & 2 Exq IEC 60079-5 - Sand filled
Zones 0,1 & 2 Exs AS 1826 AS 1076.8 Special protection
Zones 20, 21 & 22 D.I.P AS/NZS 61241.3 AS/NZS 61241.3 Dust ignition proof
Zones 20, 21 & 22 Exi AS 2380.7 AS 2381.7 Intrinsic safety
Zones 20, 21 & 22 Exm AS 2431 - Encapsulation
Zones 20, 21 & 22 Exp AS 2380.4 AS 2380.4 Pressurised
rooms & encl.
0-4
A Acetylene
DEGREES OF PROTECTION
Note: The information in this catalogue is subject to change and should always be verified against the
current Australian Standard.
0- 5
Ex protection techniques
0- 6
Note: 1 The explosion protection certification of the equipment alone does not necessarily mean it
has an adequate degree of protection for specified weather or environment. Hence it is
necessary to check the IP rating of the equipment before selection for a particular
environment.
2 All GOVAN equipment is tested and certified for minimum IP 65 rating.
0-7
Source IEC (281) 882-8300 www.sourceiec.com
QUICK REFERENCE GUIDE
Description Section
Adaptors 8
Break glass alarms 4
Beacons - rotating 1
- flashing 1
Bells 4
Cable glands 8
Conduit fittings - weatherproof 8
Circuit breakers 6
Compound 8
Control stations 9
Pushbuttons 9
Pilot lights 9
Switch 9
Custom built control panels 6
Distribution boards 6
Dust ignition proof junction boxes (D.I.P.) 3
Increased safety junction boxes (Exe) 3
Elbows 8
Enclosures with windows 5, 6
Flameproof junction boxes (Exd) 3
Small round 3
Rectangular 3
Large 3
Screwed cover 3
Float switch 4
Foot and palm switch 4
Fluorescent lights 1
Zone 1
Zone 2 1
Flood lights 1
Zone 1
Zone 2 1
High bay lights - High intensity discharge 1
Zone 1
Zone 2 1
Incandescent lights 1
Instrument enclosures 5
Isolators 2
0-8
Source IEC (281) 882-8300 www.sourceiec.com
QUICK REFERENCE GUIDE
Description Section
Junction boxes 3
Exd 3
Exe & D.I.P. 3
Key switches 2
Lighting 1
Limit switches 4
Motor starters 6
DOL 6
Star/Delta 6
Reversing 6
Meter housing 5
Modules - components 2
Motor control centres 6
Nipples 8
Panelboards 6
Pilot lights 2
Plugs 7
Pressur e switches 4
Pushbutton stations 2
Pressurised systems 5
Receptacles 7
Reducers 8
Switch racks / switchboards 6
Selector switches 2
Sealing fittings 8
Strobe lights 1
Sealing compounds 8
Stopping plugs 8
Sail switch 4
Security camera 4
Tank observation lights 1
Tees 8
Thermostats 4
Unions 8
Vessel lights 1, 4
Weatherproof conduit fittings 8
0-9
Source IEC (281) 882-8300 www.sourceiec.com
SECTION 1
SECTION 1 Ex LIGHTING
GL4M Exd Mercury vapour well glass Zone 1 and 2 1-6 to 1-7
GL4H Exd Metal halide well glass Zone 1 and 2 1-6 to 1-7
GL3M Exn/D.I.P. Mercury vapour well glass Zone 2, 21 and 22 1-8 to 1-9
GL3H Exn/D.I.P. Metal halide well glass Zone 2, 21 and 22 1-8 to 1-9
GL9M Exn Stainless steel mercury vapour fixture Zone 2 1-10 to 1-11
GL9H Exn Stainless steel metal halide fixture Zone 2 1-10 to 1-11
Features
• Body is produced from non corrosive glass fibre reinforced polyester
• Diffuser is produced from impact proof polycarbonate, textured for improved light Govan Golux 2 series luminaires are for
distribution general purpose lighting, suitable for
outdoor and indoor applications, in Exn
• Retaining clips for diffuser are made from corrosion resistant stainless steel
and D.I.P hazardous locations
• Gear tray is powder coated white and is removed by single action securing locks,
and attached with safety cords for ease of maintenance
• Quality control gear is used to ensure a high running efficiency
• Entry configuration allows through wiring, and on twin tube units an additional
entry at one end, up to M20
• Standard control gear 240 V, 50 Hz. Other voltages on request
• Eye bolt mounting supplied as standard, optional mounting available
• Power factor correction
Dimensions (mm)
Specifications
GL2 fluorescent fixture
Classification Degree of protection
IEC 60079-0 IP66
IEC 60079-15
IEC 61241-1-1
Approval Type of protection
Certificate No. IECEx CSA 07.0005X nA, DIP
Ex nA IIC T3 IP66
DIP A21 Ta T4 IP66
Ordering Information
Dimensions (mm)
Watts Weight A B C D Cat. NO.
2 x 18 2.6 kg 676 398 154 124 GL2-18T
2 x 36 5.5 kg 1276 798 154 124 GL2-36T
2 x 58 6.8 kg 1576 1100 154 124 GL2-58T
Options
• Add option suffix to catalogue number : -Suffix
• Through wiring (M20 entry each end) : -T
• Ceiling mounting : -C
• Eyebolt hanger mounting : -H
• Pipe mounting (1 - 1/4" pipe) : -P
• Wall mounting (90 degrees) : -W
• Maintained emergency battery pack : -ME
• Non-maintaining emergency battery pack : -NME
• Typical ordering code : GL2-36T-T-C-ME
Standards Compliance
Exd : CLASS 1 ZONE 1 TO AS 2380.2
GAS GROUPS : II C
TEMPERATURE : T5, T6
DEGREE : IP66
Exd APPROVAL : AUS Ex 3735
Features
• Control box and end cap are from a corrosion resistant Aluminium alloy.
• Polycarbonate tube outer case. ( Optional Toughened Glass Tube Outer case)
• Screwed Body arrangement is easily disconnected for lamping of fitting.
• Powder coated mild steel mounting reflector for greater light distribution.
• Standard control gear supply is 240V. 50Hz. Other supplies available on request.
• Entry 2x M20 (Standard)
OPTION: Emergency light fitting available with 2-hour battery back-up. Other
ratings on request.
Emergency Light Cat No.: GL7-T18-ME (TYP) For maintained emergency.
GL7-T18-NME (TYP) For non-maintained emergency.
Features
• The GL 10 series luminaire is a well glass light fitting without control gear suitable
for hazardous area Group II Zone 1 & 2. It can be fitted with lamps up to 200 watt
incandescent, 160 watt self ballasted Mercury Vapour and SL type fluorescent
up to 25 watt
• Stainless steel hardware
• Ribbed body for added strength and better cooling of the light fitting
• One piece silicon gasket for water tight seals
• Variety of mounting arrangements
• Choice of reflectors in polyester
GL10 with polyester dome reflector
• Toughened and tempered heat r esistant glass
Specifications
GL10 Well glass
Classification Ambient temperature
IEC 60079-0 -20 ˚C to 50 ˚C
IEC 60079-1
Approval Lamp holder
IECEx TSA 07.0004X Porcelain ES or BC
Exd IIB T* IP66
Temp Class : T3-T6
ATEX : Sira 07ATEX1131X
II2G
Degree of protection Terminals
IP 66 Insulated connectors up to 4 sq mm
Housing material Weight
Marine grade corrosion resistant Aluminium alloy - 7 kg
aluminium alloy or cast stainless steel Stainless steel - 15.5 kg
grade 316
Diffuser Cable entry
Impact resistant toughened glass Standard 2 x M20
Reflector Standard finish
Polyester RAL7032 for aluminium alloy fitting
Stainless steel - unpainted
Rated voltage
220-250 V ±10 %, 50 Hz
Options
1. Luminaire housing from cast stainless steel grade 316.
2. Other voltages and frequencies available.
3. Two coat epoxy paint finish.
4. Other cable entries available as requested.
Accessories
1. Variety of reflectors.
2. Wire guard for glass globe.
3. Cast aluminium guard.
O rdering Information
Temp Ceiling Mount Pendant Mount Wall Mount 15˚ Wall Mount
Lamp Type Watts Rating Cat. No. Cat. No. Cat. No. Cat. No.
Incandescent 75 T5 GL10N07C GL10N07P GL10N07W GL10N07AW
Incandescent 1 0 T5 GL10N010C GL10N10P GL10N10W GL10N10AW
Incandescent 150 T5 GL10N015C GL10N15P GL10N15W GL10N15AW
Incandescent 200 T4 GL10N020C GL10N20P GL10N20W GL10N20AW
Self ballasted mercury 100 T5 GL10M10C GL10M10P GL10M10W GL10M10AW
Self ballasted mercury 160 T3 GL10M16C GL10M16P GL10M16W GL10M16AW
Fluorescent SL 18 T6 GL10F18C GL10F18P GL10F18W GL10F18AW
Fluorescent SL 23 T6 GL10F23C GL10F23P GL10F23W GL10F23AW
Features
The GL4 series luminaire is a high intensity discharge (H.I.D.) well glass
fitting suitable for hazardous area Group II Zone 1 & 2. It can be fitted with lamps
up to 400 watt high pressure Sodium, Mer cury Vapour and Metal Halide
Integral control gear
Stainless steel hardware
Hinged cover allows ease for servicing and relamping
One piece silicon gasket for water tight seals
Variety of mounting arrangements
Choice of reflectors in polyester and aluminium
Stanchion mounting bracket allows 10 to 150˚ rotation in vertical plane for setting
light direction
Ideal for use as a symmetrical floodlight with aluminium reflector and yoke arm
Specifications
GL4 well glass
Classification Rated voltage
Group IIII, Zone 1 & 2, 220-250 V ±10 %, 50 Hz GL4 with aluminium dome reflector
Exd Gas group IIIIA & II B (II
IIIIB + H2), T3
Approval Ambient temperature
AUS Ex 2017 to AS 2380-2 (IEC 60079 -1) -20 ˚C to 50 ˚C
Degree of protection Lamp holder
IP 66 Porcelain E27 or E40
Housing material Terminals
Marine grade corrosion resistant High grade melamine up to 4 sq mm
aluminium alloy or cast stainless steel
grade 316
Diffuser Weight
Impact resistant toughened glass Aluminium alloy - 24 kg
Stainless steel - 37 kg
Reflector Cable entry
Polyester, aluminium Standard 2 x M20
Control gear integral
Standard finish
RAL7032 for aluminium alloy fitting
Stainless steel - unpainted
Options
1. Luminaire housing from cast stainless steel grade 316.
2. Other voltages and frequencies available.
3. Two coat epoxy paint finish. GL4 with well glass
4. Other cable entries available as requested.
Accessories
1. Variety of reflectors.
2. Wire guard for glass globe.
Ordering Information
Ceiling Mount Pendant Mount Stanchion Mount Wall Mount
Lamp Type Watts Cat. No. Cat. No. Cat. No. Cat. No.
Mercury vapour 80 GL4M08C GL4M08P GL4M08S GL4M08W
Mercury vapour 125 GL4M12C GL4M12P GL4M12S GL4M12W
Mercury vapour 250 GL4M25C GL4M25P GL4M25S GL4M25W
Mercury vapour 400 GL4M40C GL4M40P GL4M40S GL4M40W
HPS 70 GL4S07C GL4S07P GL4S07S GL4S07W
HPS 150 GL4S15C GL4S15P GL4S15S GL4S15W
HPS 250 GL4S25C GL4S25P GL4S25S GL4S25W
HPS 400 GL4S40C GL4S40P GL4S40S GL4S40W
Metal halide 175 GL4H17C GL4H17P GL4H17S GL4H17W
Metal halide 250 GL4H25C GL4H25P GL4H25S GL4H25W
Metal halide 400 GL4H40C GL4H40P GL4H40S GL4H40W
Stanchion
Mounting
Specifications
Gl3 Well glass
Classification Degree of protection
ExnR Group IIII, Zone 2 to AS 2380.9 IP 66 to AS 1939
D.I.P Group II to AS 2236
Gas group IIC
Approval Temperature class
Certificate No. Ex 967x T2-T3 (up to 250 W with prismatic glass )
D.I.P Certificate AUS Ex 935x T4 ( up to 250 W Reflector/Lens)
T3 (400 W Reflector/Lens)
Technical Data
Voltage / Frequency 240 V/50 Hz … Other voltages available on request Cat. No. GL3
Wattage Mercury Vapour 50, 80, 125, 250, 400 W
Metal Halide 175, 250, 400 W
High Pressure Sodium 50, 70, 150, 250, 400 W
Power factor 0.85, Integral Ballast Dimensions (mm)
Weight MV MH HPS
Under 250 W 10 kg 15 kg 11 kg
250W 11 kg 16 kg 12 kg
Ceiling
400 W 12 kg 18 kg 14 kg Mounting
Lamp Holder Porcelain E27 (low wattages) or E40 (high wattages)
Terminal Block High grade Melamine for up to 4 mm2 wire. Insulation grade
105 ˚C up to 250 W, 115 ˚C for 400 W
Cable Entries 2 x M25 conduit standard, M20 optional. (One entry
plugged and available for restricted breathing test of
installation).
Materials High grade cast aluminium body, grey enamel finish.
Silicone rubber seals. Stainless steel external hardware.
Fibreglass reinforced polyester or spun aluminium reflectors. Pendant
Mounting
Photometrics
Stanchion
Mounting
Ordering Information
The above fixtures are fitted with prismatic glass globes as standard up to 250 watt and
refractor glass as standard on 400 watt lights. If guards, reflectors or different optics are
required then the following suffix should be added to the basic code selected above.
The GOLUX 9 stainless steel luminaire is a high intensity discharged light fixture for use
with Mercury Vapour, High Pressur e Sodium and Metal Halide lamps up to 400 watt.
The GOLUX9 light fitting is designed for Group II Zone 2 hazardous areas with extreme
corrosive environments.
Typical examples of these types of areas are oil and gas platforms, refineries, wharfs,
jetties and any environments where salt water or salt laden air creates corrosion problems.
Specifications
GL9 Stainless steel luminaire
Classification Degree of protection
ExnR Group IIII, Zone 2 to AS 2380.9 (IEC 60079-15) IP 66
Gas group IIIIC
Approval Temperature class
Certificate AUS Ex 2035X T2-T4
Voltage/Frequency Power factor
220-250 V, 50 Hz (other voltages available) 0.85 Cat. No. GL9
Wattage Weight
Mercury Vapour … 50, 80, 125, 250, 400 W MV - 11 kg
Metal Halide … 175, 250, 400 W MH - 16 kg
High Pressure Sodium 50, 70, 150, 250, 400 W HPS - 12 kg
Ambient temperature Lamp holder
-20 ˚C to 50 ˚C Porcelain E27 E40
Cable entries Control gear
2 x M25 conduit standard, other sizes Integral
optional. Pendant 1 … 1/4" BSP.
Features
The fittings housing and covers are produced from 1.5 mm thick 316
grade stainless steel
All securing screws and other hardware used is stainless steel
Control gear is integrally mounted and is easily accessible for maintenance
Factory mounted terminal block for ease of field wiring
One piece silicon gaskets for long lasting water tight seals
Heat resistant clear prismatic glass globe fitted to housing by screwing into a
stainless steel 316 grade retaining ring
Ordering Information
Options
Suffix to be added to code
Polyester, 30˚ angle A
Polyester dome D
Wire guard 1
Typical examples of codes:
GL9M12W-A1, GL9S25C-BS
Notes
1 Lamps not included as part of
supply unless specifically
requested as a priced option.
2 Specify conduit entry size (default
size is M25)
Features
The GL16 series luminaire is a high intensity discharge (H.I.D) floodlight fitting
suitable for use in hazardous area, Zone 1 and 2. It can be fitted with lamps up to
600 watt high pressur e Sodium or up to 400 watt Mercury Vapour and Metal Halide
Hinged cover for ease of maintenance and relamping
Stainless steel hardware
Yoke mounting allows a 120˚ rotation in the vertical plane for setting light direction
Integral control gear
Variety of mounting arrangements
Specifications
GL16 Floodlight Diffuser
Classification Degree of protection
Zone 1 & 2 Exd IP 66
Gas group IIIIB + H 2
Approval Housing material
AUS Ex 3660X to AS 2380 -2 (IEC60079 -1) Marine grade corrosion
resistant Aluminium alloy
Cat. No. GL16
Diffuser Reflector
Impact resistant toughened glass High purity anodised
aluminium
Rated voltage Ambient temperature
220-250 V ±10%, 50 Hz -20 ˚C to 50 ˚C
Lamp holder Terminals
Porcelain ES 40 High grade melamine up
to 4 sq mm
Luminaire weight Cable entry
Aluminium - 42 kg without control gear Standard 2 x M25
Control gear
Integral
Options
1. Other voltages and frequencies available
2. Two coat epoxy paint finish
3. Other cable entries available as requested
Accessories
1. Pole mounting adaptor
2. Wire guard
3. Deflector / Weather hood
Ordering Information
Lamp Yoke mount Pole mount Wall mount
type Watts T rating Cat. No. Cat. No. Cat. No.
Metal halide 250 T3 GL16H25Y GL16H25P GL16H25W
Metal halide 400 T2 GL16H40Y GL16H40P GL16H40W
HPS 250 T3 GL16S25Y GL16S25P GL16S25W
HPS 400 T2 GL16S40Y GL16S40P GL16S40W
Mercury vapour 250 T3 GL16M25Y GL16M25P GL16M25W
Mercury vapour 400 T2 GL16M40Y GL16M40P GL16M40W
Pole Mounting
Features
Remote gear (in either Exn or Exd enclosure)
Long life and low maintenance
Adjustable lamp bracket for required aiming angle
Floodlight … Heavy duty die cast, low copper content aluminium body, large
efficient 99.9 % pure non-ageing aluminium reflector. Hot dip
galvanised mounting bracket (or powder coated). Stainless steel
external screws, nuts, bolts and clips
Glass … Toughened safety. High temp. silicon rubber gaskets
Beam types … Narrow (5 x 2), Wide (6 x 6) Cat. No. GD (Titan)
Lamp … Bench tested and supplied with each floodlight
… All lamps are high output HID tubular type
Control gear … Standard reactor type to .85 pfc, supplied separately on a
pre-wired and tested gear tray assembly; or Exn / Exd enclosures
IP Rating … IP 66, Simtars Report No. NE92/0129
Dimensions (mm)
Applications
Large area lighting, car park, industrial sites, jetties, tank farms, marshalling yards,
marinas, quays, security areas, wharfs, refineries and petrochemical complexes etc.
Specifications
GD Floodlight
Classification Degree of protection
ExnR Group II , Zone 2 IP 66
Gas Group IIIIC
Approval Temperature class
Ex 2034X to AS 2380.9 (IEC 60079 -15) T2
Circuit diagram
Accessories / Options
GD1185 240 V to 415 V transformer
GD1186 240 V 2 kW lamp and ignitor
GD1190 cast aluminium waterproof gear box
GD1192 louvre, vertical
GD1193 415 V gear and D1190
GD1195 louvre, horizontal
Isolux Contours
(Titan wide beam floodlight)
The isolux contours are standardised in a grid determined by the mounting height (h).
Used as a design tool, the accompanying multi-purpose contours, makes it possible to
estimate the area covered and illuminance levels, based upon the nominated mounting
height/scale related contours for each lamp type.
The position of the maximum Eh value is marked (A) and is 100 %. The isolux contours
B, C, D and E are percentage contours of that maximum.
The curves and effective illuminances are valid only, when the TITAN GD 115 floodlight
is aimed at 65˚ to the downward vertical.
Features
Both body and cover are made of heavy duty one-piece pressure die cast low copper
content aluminium or stainless steel fabricated fitting type GL5
Hinged cover for ease of access to integral ballast and capacitor
Thermal shock and impact resistant glass lens
Gaskets are of heavy duty, high temperatur e silicon rubber GL5/2 Flood Light Fitting
Porcelain heavy duty ES40 socket with spring loaded centre contact and brass nickel
plated double lamp grip screw shell
High grade dimpled, pure aluminium reflector
Different mounting options available
Multiple Operators
Ordering Information
Polyester Stainless steel
Description Cat. No. Cat. No.
3 Pushbutton 1 N/O + 1 N/C engraved to suit EP2315-1-1-1 ES2315-1-1-1
1 Mushroom head 1 N/O + 1 N/C
Emergency stop button twist to reset
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-3 ES2315-1-1-3
1 Mushroom head 1 N/O + 1 N/C
Emergency stop key to reset
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-4 ES2315-1-1-4 Cat. No. ES2315-1-1-1-1-1-1
1 Mushroom head 1 N/O + 1 N/C stop button
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-8 ES2315-1-1-8
1 LED pilot light 24, 48, 110, 240 V AC/DC
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-11 ES2315-1-1-11
1 Selector switch OFF/ON + 2 N/O
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-1-1-201 ES2315-1-1-201
1 Meter 48 mm
2 Pushbuttons 1 N/O + 1 N/C recessed actuator EP2315-ME-1-1 ES2315-ME-1-1
1 Meter 48 mm
1 Selector switch OFF/ON
2 N/O EP2315-ME-201 ES2315-ME-201
Specifications
MN Push button modules
Classification
Temperature rating
Group II Zone 1 and 2 T6
Gas Group II B
II B+H2 also available
D.I.P. Zones 21 and 22
Approvals Degree of protection
For use in certified Exd Enclosures IP 66 protection to AS 1939
Exd to AS 2380.1
Aus Ex 1268U
Current ratings Rated voltage
3 Amps 240 V standard Pushbutton - Key operated
Cat. No. MN05
other voltages available
Electrical components Standard finish
1 N/C or N/C Anodised aluminium
OPTION: 2 Additional Contacts available
Specifications
Lamp type pilot light No. 11 module
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas Group IIIIB
IIIIB+H 2 also available
D.I.P. Zones 21 and 22
Approvals Degree of protection
For use in Certified Exd enclosures IP 66 protection to AS 1939
Exd to AS 2380.1
Aus Ex 1268U
Specifications
CA10 Switch modules
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas Group IIIIB
IIIIB+H 2 also available
Approvals Degree of protection
For use in Certified Exd enclosures IP 66 protection to AS 1939
Exd to AS 2380.1 Cat. No. MNS0
Aus Ex 1268U
Specifications
CA20B - C42 Switch modules
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas Group IIIIB
IIIIB+H 2 also available
Approvals Degree of protection
For use in Certified Exd enclosures IP 66 protection to AS 1939
Exd to AS 2380.1
Aus Ex 1268U Cat. No. MNS1
Specifications
FC4 Control stations
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
Cat. No. FC4
II 2 G D
Standard entries Weight
2xM20 1.9 kg
Ordering Information
Step 1: Select Cat. No. of basic configuration from table A e.g. 1PB/SW/1PL = FC4H
Step 2: Select type of switch from table B e.g. 2 pole isolator = 201
Step 3: Select pushbutton from table C e.g. mushroom head turn to reset = 3
Step 4: Select type, colour and voltage of pilot light from table D e.g. Incandescent
240 V blue = FC4-H-201-3-9 blue
Table B - Switches
Table C - Pushbuttons
Code Description
1 Pushbutton recessed actuator
2 Pushbutton projecting actuator
3 Pushbutton mushroom head twist to reset
4 Pushbutton mushroom head key to r eset
5 Key operated pushbutton
6 Pushbutton mushroom head pull to reset padlockable
8 Pushbutton mushroom head
Code Description
9 Incandescent 12 V / 240 V
11 7 x LED - nominate colour and voltage
Colours - red, green, amber, blue, white.
Specifications
FWI Pushbutton stations
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Degree of protection
IECEx TSA 07.0005X IP66
Exd IIB T6 IP66
ATEX : Sira 07ATEX1132X
II 2G
Standard entries Weight
2 x M20 1.1 kg
Rated
240 V, 3 A
Ordering Information
Description Cat. No.
Pushbutton recessed actuator FWI-1
Pushbutton projecting actuator FWI-2
Pushbutton mushroom head twist to reset FWI-3
Pushbutton mushroom head key to r eset FWI-4
Key operated pushbutton FWI-5
Pushbutton mushroom head pull to reset padlockable FWI-6
Pushbutton mushroom head FWI-8
Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Standard entries Weight
2xM20 1.7 kg
Ordering Information
Description Cat. No.
Pushbutton recessed actuator FC4I-1
Pushbutton projecting actuator FC4I-2
Pushbutton mushroom head twist to reset FC4I-3
Pushbutton mushroom head key to r eset FC4I-4
Key operated pushbutton FC4I-5
Pushbutton mushroom head pull to reset padlockable FC4I-6
Pushbutton mushroom head FC4I-8
Specifications
FC4J Pushbutton stations
Classification
Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
Cat. NO. FC4
II 2 G D
Standard entries Weight
FC4J - 2 x M20 FC4J - 1.7 kg
FC4K - 2 x M25 FC4K - 1.8 kg
Multiple Operators
Ordering Information
Description Cat. No.
1 x pushbutton recessed actuator
1 x pushbutton recessed actuator FC4J-1-1
1 x pushbutton recessed actuator
1 x pushbutton projecting actuator FC4J-1-2
1 x pushbutton recessed actuator
1 x pushbutton mushroom head twist to reset FC4J-1-3
1 x pushbutton recessed actuator
1 x pushbutton mushroom head key to reset FC4J-1-4
1 x pushbutton recessed actuator
1 x key operated pushbutton FC4J-1-5
1 x pushbutton recessed actuator
1 x pushbutton mushroom head pull to reset padlockable FC4J-1-6
1 x pushbutton recessed actuator
1 x pushbutton mushroom head FC4J-1-8
Specifications
Pilot light stations
Classification Temperature rating
T6
IEC 60079-0
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X IP 66
Exd IIC T6 IP66
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Cat. No. FC4O-11
Standard voltage
240 V
Standard colours: red, green, white, amber
Ordering Information
Description Standard Entries Weight (kg) Cat. No.
1 x (7 x LED) type pilot light; colour
and voltage to be nominated 2 x M20 1.5 FC4O-11
Ordering Information
Description Standard Entries Weight (kg) Cat. No.
2 x (7 x LED) pilot lights: colour
and voltage to be nominated 2 x M20 1.6 FC4P-11
Specifications
Single gang switches
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 60079-0
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx SIM 07.0001X (FC4) IP66
Exd IIC T6 IP66
Ex td A21 IP66
ATEX: Sira 07ATEX1133X amp isolator
II 2 G D
IECEx TSA 07.0005X (FW)
Exd IIB T6 IP66
ATEX: Sira 07ATEX1132X
II 2 G
Standard entries Weight
4 x M 20 - FW and FC4A series 1 kg - FW series
4 x M 25 - FC4B and FC4C series 1.7 kg - FC4A series
2 x M 32 - FC4U and FC4V series 2.9 kg - FC4B series
Material
Marine grade aluminium
Stainless steel hardware
Ordering Information
Description Cat. No.
CA10 switch FC4A
Sail switch FC4A - SS
Float switch FC4A - FS
CA20B switch FC4B
C26 switch FC4C
Switch (CA10 to C26) + 1 pushbutton FC4D
Switch (CA10) + 2 pushbuttons FC4E
Switch (CA10 to C26) + 1 pilot light FC4F
Switch (CA10) + 2 pilot lights FC4G
Switch (CA10) + 1 pushbutton + 1 pilot light FC4H
Break glass alarm station FC4I - Q
Single pushbutton FC4I
6" bell 25 V DC or 240 V AC FC4I -BE6
2 pushbuttons FC4J
3 pushbuttons FC4K
1 pushbutton + 1 pilot light FC4L
2 pushbuttons + 1 pilot light FC4M
1 pushbutton +2 pilots FC4N
1 pilot light FC4O
2 pilot lights FC4P
Q break glass alarm station (REF to FC4I) FC4Q
3 pilot lights FC4R
2 x switches (CA10) FC4S
Thermostat FC4T
Thermostat / 2.5 kW element FC4TC
C32 switch (style 7 only) FC4U
C42 switch (style 7 only) FC4V
Email single phase motor sentinel FC4W
Combination of 4 pushbuttons (style 6 only) FC4X
Combination of pushbuttons and pilot lights (style 6 only) FC4Z
GE range Sheet steel and stainless steel Zone 1 and 2 3-3 to 3-4
Specifications
Classification Temperature class
Group II Zone 1, 2, 21 and 22 T6
Gas group IIIIC
Approvals Degree of protection
AS 2380-6 IP 66 to AS 1939
Standards Aus. Cert. non flammable
AUS Ex 2441X - EP1511,EP2315
Material Strength
Cat. No. EP2315
Glass reinforced polyester Impact resistant 7 Nm wall
thickness 3.5 mm minimum
Hinges Gaskets
For PE30315 and PE60300 Neoprene rubber
Dimensions (mm)
Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIC
Approvals Degree of protection
Cat. No. GE33
SAA Cert. No. AUS Ex 869X for IP67
GE33, GE45 and GE56
Material Gaskets
Sheet metal / Stainless steel Neoprene rubber
Gland plates Hinges
1 or 3 2 pin type or bracket type
Dimensions (mm)
Specifications
Classification Temperature rating
Zone 1, 2, 21 and 22 T6
Gas group of IIIIC
Approval Degree of protection
D.I.P. - AS2236 DE1…IP65, DE2…IP 66,
Standards Australia Certificates DE3…IP 66, DE4…IP 66
DE1 AUS Ex 699, DE2 Ex 1173X,
DE3 Ex 1176X, DE4 Ex 3277X
Ordering Information
Maximum No. of terminals
2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 Weight Cat No. Cat. No. DE2
12 … … … … 1.3 kg DE1-2
… 10 … … … 1.3 kg DE1-4
24 … … … … 4 DE2-
k
… 20 … … … 4 k
DE2-
… … 18 … … 4.2 kg DE2-
… … … 15 … 4.3 kg DE2-1
… … … … 12 4.3 kg DE2-1
64 … … … … 9.5 kg DE3-2
… 60 … … … 9.5 kg DE3-4
… … 50 … … 9.5 kg DE3-6
… … … 40 … 9.4 kg DE3-10
… … … … 20 9.5 kg DE3-16
160 150 125 104 86 18.5 kg DE4
Specifications
DE Range (Aluminium)
DE1
Approx. weight - 1.3 kg
DE2
Approx. weight - 4 kg
DE3
Approx. weight - 9.5 kg
DE4
Approx. weight - 18.5 kg
FW Junction Boxes
Specifications
Classification Temperature rating
IEC 60079- 0 T6
IEC 60079-1
Approvals Degree of protection
IECEx TSA 07.0005X IP66
Exd IIB T6 IP66
ATEX: Sira 07ATEX1132X
II 2 G
Weight Material
600 g Aluminium / stainless steel hardware
Accessories
4 way terminal blocks
Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIIIB Cat. No. F35
II B+H2 also available
Approvals Degree of protection
Dimensions (mm)
Exd to AS 2380.2 IP 66 to AS 1939
Cert. No. Aus Ex 853
Weight
15.5 kg
Maximum No. of entries per side
Entry location M 20 M 25 M 32 M 40 M 50
Top & bottom only for
standard junction boxes 11 9 6 4 2
1
Maximum No. of entries per side )
Entry location 1
/2 " 3
/4" 1" 1-1 /4 " 1-1 /2 " 2"
Top & bottom only for
standard junction boxes 11 9 6 4 2 1
Note: 1) All are NPT threads
1
Maximum No. of entries per side )
Entry location 1
/2 " /4"
3
1" 1-1 /4 " 1-1 /2 " 1-3 /4 " 2"
Long side 26 18 12 8 6 6 4
Short side 12 8 6 5 3 3 2
Note: 1) All are NPT threads
Specifications
Classification Temperature rating
IEC 60079- 0 T6
IEC 60079-1
Approval Degree of protection
IECEx SIM 07.0002X IP66 Cat. No. F560
F560 - Ex d IIB T6 IP66
FH560 - Ex d IIB+Hydrogen T6 IP 66
ATEX : Sira 07ATEX1137X
Dimensions (mm)
II 2 G
Weight Standard Finish.
54 kg/153 kg Aluminum/Cast Iron/ Stainless Steel
hardware
Specifications
Classification Temperature rating
Group II Zone 1 and 2 T6
Gas group IIIIB Cat. No. F24
IIIIB+H2 also available
Approvals Degree of protection Dimensions (mm)
Exd to AS 2380.2 IP 66 to AAS 1939
Cert. No. Aus Ex 837
Weight Internal dimensions
85 kg 698 x 394 x 101 mm
P/buttons
Internal dimensions Overall dimensions Classification Klippon P/light Switch
Cat. No. H x W x D (mm) H x W x D (mm) Entries Cover Exd D.I.P. terminal modules modules
FW 64 dia x 41 114 dia x 60 All sides Flat & dome X 1 x BK4 1 1
FJ1 64 dia x 41 114 dia x 60 All sides Dome screw on X 1 x BK4 Nil Nil
FC4 104 dia x 60 152 dia x 80 All sides Flat & dome X X 10 x SAK2.5 4 2
FC4/5 110 dia x 80 160 x 170 x 100 All sides Flat & dome X 12 x SAK2.5 4 2
DE1 120 x 78 x 50 172 x 85 x 70 All sides Flat Exe X 15 x SAK2.5 2 1
DE2 178 x 178 x 128 200 x 200 x 152 All sides Flat Exe X 24 x SAK2.5 9 9
DE3 246 x 246 x 128 300 x 300 x 160 All sides Flat Exe X 64 x SAK2.5 16 16
DE4 680 x 300 x 128 738 x 350 x 160 All sides Flat X X 160 x SAK2.5 40 40
FC15 150 dia x 75 210 dia x 110 Top & bottom Flat X X 20 x SAK2.5 7 4
F7 170 x 170 x 120 210 x 210 x 156 All sides Flat X X 20 x SAK2.5 7 4
F7D 170 x 170 x 177 210 x 210 x 213 All sides Dome X X 43 x SAK2.5 4 4
F22 228 x 177 x 150 295 x 245 x 200 Top & bottom Flat X 33 x SAK2.5 9 9
F35 304 x 228 x 150 370 x 295 x 200 Top & bottom Flat X 50 x SAK2.5 12 12
F150 411 x 279 x 160 490 x 358 x 208 All sides Flat X 150 x SAK2.5 24 24
F160 411 x 279 x 230 490 x 358 x 275 All sides Dome X 150 x SAK2.5 4 4
F42 362 x 207 x 154 400 x 245 x 196 All sides Flat
F400 507 x 305 x 206 570 x 368 x 255 All sides Flat X 200 x SAK2.5 TBA TBA
F24/2 698 x 394 x 190 775 x 470 x 280 All sides Dome X 400 x SAK2.5 TBA TBA
F560 525 x 425 x 170 600 x 500 x 224 All sides Dome X 160 x SAK2.5 36 36
Table A
0 1 2 3 4 5 6 7
Metric = (M) - 16 20 25 32 40 50 63
BSP = (P)
1
/2" - 3
/ 4" 1" 1 1/4" 1 1/2" 2" -
NPT = (T) 1
/2" - 3
/ 4" 1" 1 1/4" 1 1/2" 2" -
Conduit = (C) - 5
/8" 3
/ 4" 1" 1 /4"1
1 /2"
1
2" 2 / 2"
1
Table B
When ordering please specify type of wiring method, eg. conduit - pyrotenax -
gland, etc.
F7 M3 5 23
5 entries
(Refer page 3-9)
Specifications
F7PS pressure switches
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Degree of protection
IECEx TSA 07.0029 IP 66
Ex d IIB T6 IP66
Ex tD A21 T80 0C IP66
ATEX: Sira 07ATEX1134
II 2 G D Cat. No. F7PS
Standard finish Current rating
Aluminium Volts and amps to be advised
Dimensions Internal dimensions
210 x 210 mm F7A2D = 115 mm deep Dimensions (mm)
F7A2DD = 155 mm deep
F7PS = 205 mm deep
Specifications
FWI-Q Break glass alarm
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Degree of protection
IECEx. TSA 07.0005X IP 66
ATEX : Sira 07ATEX1132X
Exd IIB T6 IP66
Current rating Weight
240V,3A 1.9 kg.
Standard Finish Dimensions
Aluminium 114x 114x 143
= mm
Catalogue number
FWI-Q
Specifications
FC4 Limit switch
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Degree of protection
IECEx TSA 07.0005X IP 66
Ex d IIB T6 IP66
ATEX: Sira 07ATEX1132
II 2 G D
Current rating Weight
240 V, 5 A 1.8 kg Cat. No. FW1 - LP
Standard finish Dimensions
Aluminium 114 x 136 x 60 mm
Catalogue number
FW1 - LP
FW1 - LR
Specifications
FC4FT Foot & palm switch Dimensions (mm)
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1 o 152
IEC 61241-0 o 7. 130
IEC 61241-1
2 HOLES G O VA N
Approvals Current rating
IECEx SIM 07.0001X 240 V, 3 A
Exd IIC T6 IP66
56
Ex tD A21 IP66
ATEX: Sira 07ATEX1133X
II 2 G D
Standard finish Weight
Aluminium 1.5 kg 166
Dimensions Catalogue number
153 x 153 x 160 mm FC4FT
Applications
Refineries/petrochemical complexes, boundary monitoring, security for petrochemicals,
defence stores and continuous area monitoring etc.
Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
IEC 61241-0 Cat. No. F7PD
IEC 61241-1
Approvals Degree of protection
IECEx TSA 07.0029 IP 66
Ex d IIB T6 IP66
0
Weight Ex tD A21 T80 C IP66
ATEX: Sira 074ATEX1134
II 2 G D
Weight Catalogue number
10 kg F7PD
Specifications
FCB Circuit breakers
Classification Degree of protection Temperature rating
Zone 1 and 2 IP 66 T6
Gas Group II B
Approvals
Exd protection to IECEx TSA 06.0054 (F150 & FH150)
AS 2380, Aus Ex 460X ATEX: Sira 07ATEX1135X
IECEx TSA 07.0029 (F7) II 2 G
ATEX: Sira 07ATEX1134
II 2 G D
Current rating Ordering information
415/240 V, 6/100 A / 225 Cat. No. FCB/no.breakers/no.
of poles
Standard finish Dimensions
Aluminium Please refer to section 3 Current
Enclosure Poles Breakers kA (Amp) Cat. No.
Ordering information FC15D 2 1 6 6-40 FCB2
FC15D 2 2 6 6-40 FCB22
No. of kA FC15D 3 1 6 6-40 FCB3
Poles rating FC15D 4 1 6 6-40 FCB4
F22 3 2 6 6 - 100 FCB23
1. FCB kA
F35 4 2 6 6 - 100 FCB24
No. of Current F22 2 3 6 6 - 100 FCB32
Breakers rating F35 3 3 6 6 - 100 FCB33
F6 4 3 6 6 - 100 FCB34
F6 2 4 6 6 - 100 FCB42
2. Combination of different kA incoming and outgoing breaker F6 4 3 6 6 - 100 FCB43
Incoming Outgoing No. Outgoing F150 4 4 6 6 - 100 FCB44
Current rating of Breakers Current rating F6 2 5 6 6 - 100 FCB52
F150 3 5 6 6 - 100 FCB53
kA
Current
kA Enclosure Poles Breakers kA (Amp) Cat. No.
Incoming Incoming No. of
Poles kA Poles rating F6 2 6 6 10 - 100 FCB62
F150 2 7 6 10 - 100 FCB72
3 Cir cuit breakers available with earth leakage relay and shunt F150 2 8 6 10 - 100 FCB82
trip on r equest.
FC15D 2 1 6 10-40 FCB2EL
4 For a greater number of breakers and distribution boards,
FC15D 2 2 6 10-40 FCB22EL
more than one enclosure is joined together by compound
bush. F22 3 1 6 10-13 FCB3EL
5 Custom built distribution boards with a combination of F22 4 1 6 10-13 FCB4EL
isolators and circuit breakers is available. F22 3 1 18 10-63 FCB3-63
F22 4 1 18 10-63 FCB4-63
F35 3 1 18 10 - 100 FCB3-100
F35 4 1 18 10 - 100 FCB4-100
F35 3 1 18 10 - 125 FCB3-125
F35 4 1 18 10 - 125 FCB4-125
F150 3 1 18 10 - 160 FCB3-160
F150 4 1 18 10 - 175 FCB4-175
F150 3 1 18 10 - 200 FCB3-200
F150 4 1 18 10 - 200 FCB4-200
Control stations / switchboards are suitable for hazardous area Group II Zone
1, Gas group IIA, and IIB+H2
Dimensions (mm)
F6 Control Panel
Dimensions (mm)
Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Cat. No. FRT1
Approvals Weight
IECEx TSA 06.0020 1.1 kg
ATEX : Sira 07ATEX1139
II 2 G Dimensions (mm)
Standard finish Dimensions
Plated brass 59 x 59 x 124 mm
Ordering Information
Gland Entry
Volts Amps Pins Sizes Cat. No.
240 / 250 10 / 15 / 20 3 20 mm FRT1-3 / FRT2-3
415 / 440 10 / 15 / 20 4 25 mm FRT1-4 / FRT2-4
415 / 440 32 3/4/5 25 mm FRT3-3 / FRT3-4 / FRT3-5
415 / 440 40 4/5 32 mm FRT4-4 / FRT4-5
415 / 440 63 4/5 32 mm FRT5-4 / FRT5-5
Dimensions (mm)
FP Power outlet
The Govan power outlet has a fully interlocking switch mechanism. Switching is
achieved by the insertion and rotation of the plug. The plug cannot be withdrawn
when the switch is on and cannot be switched on unless the plug is fully inserted.
Having an internally operated switch the FP type outlet especially suitable for harsh
environments.
Specifications
Classification Temperature rating
IEC 60079-0 T6
IEC 60079-1
Approvals Weight
IECEx TSA 06.0020 4.5 kg
Ex d IIB T6 IP66
IP44 When socket & plug engaged
ATEX: Sira 07ATEX1139
II 2 G
Degree of protection Entry
IP 66 M25
Volts, Current rating Standard finish
415 / 240 V, 16 / 63 A Aluminium
The FP power outlets are manufactured from corrosion resistant marine grade aluminium
and use stainless steel hardwar e.
O rdering Information
Outlet Code Amps Volts Pins Plug Code
FP 103 10 240 3 FRT1-3
FP 153 15 240 3 FRT1-3
FP 203 20 240 3 FRT2-3
FP 104 10 415 4 FRT1-4
FP 154 15 415 4 FRT1-4
FP 204 20 415 4 FRT2-4
FP 324 32 415 4 FRT3-4
FP 325 32 415 5 FRT3-5
FP 404 40 415 4 FRT4-4
FP 405 40 415 5 FRT4-5
FP 634 63 415 4 FRT5-4
FP 635 63 415 5 FRT5-5
ADAPTORS
Flameproof accessories for explosive atmospheres
FA Adaptors
External to Internal
Size Conduit to Metric Cat.No.
3/4" 20 mm FACM 2-2
1" 25 mm FACM 3-3
1 1/4" 32 mm FACM 4-4
1 1/2" 40 mm FACM 5-5
Cat. No. FAMC_
2" 50 mm FACM 6-6
SEALING FITTINGS
Flame proof accessories for explosive atmospheres
Sealing Compound
o
Type SC2. 3M Scotch N 4 Electrical Resin
FHN Nipples
Size Metric Cat. No.
20 mm 20 - 20 FHNM2
25 mm 25 - 25 FHNM3
32 mm 32 - 32 FHNM4
40 mm 40 - 40 FHNM5
50 mm 50 - 50 FHNM6
63 mm 63 - 63 FHNM7 Cat. No. FHNM_
Sealing Compound
FR Reducers
External to Internal
Size Metric Cat. No.
20 mm 16 mm FRMM 2-1
25 mm 20 mm FRMM 3-2 Cat. No. FRMM_
32 mm 25 mm FRMM 4-3
Approvals
40 mm 32 mm FRMM 5-4
IECEx CSA 06.0008U
50 mm 40 mm FRMM 6-5 ATEX: Sira 07ATEX1140U
63 mm 50 mm FRMM 7-6 II 2 G D
NPT to metric
Type of Protection: Ex d IIC, DIP A21
Size Metric Cat. No.
/ 4"
3
20 mm FRTM 2-2 Classification
1" 25 mm FRTM 3-3 IEC 60079-0
1 1/ 4" 32 mm FRTM 4-4 IEC 60079-1
IEC 61241-1-1
1 / 2"
1
40 mm FRTM 5-5
2" 50 mm FRTM 6-6
Note: All nipples and reducers are manufactured from brass. Other combinations are
available.
O35
32 mm DLM4
40 mm DLM5
47.5
50 mm DLM6
63 mm DLM7
75 mm DLM8
Note: Optional Materials: Aluminium, S. Steel, Brass (Nickel Plate)
O35
FT Tees 1 )
Size Cat. No.
20 mm FT2
25 mm FT3
1/2" BSP FTP0 40
3/4" BSP FTP 2
FL Elbows 1)
Size Cat. No.
O41
20 mm FL2
25 mm FL3
1/2" BSP FLP0
3/4" BSP FLP 2
Note: 1) Made from Aluminium. Approval No. ANZEx. 07.3045 Cat. No. FL_
CONTROL STATIONS
DE DE range 9-3
F7 F7 range 9-4
LIGHTING
Specifications
Classification Degree of protection
Certified for D.I.P. T6 Zones 21 & 22 IP 65/66
Approvals Rated voltage
Cert. of conform Aus Ex 2441X 240 V AC
Standards Aus. AS 2236
AS 1939
Int. standards IEC 61241
Complete range of stainless steel
Rated current Cable entries and polyester control stations
3A Control stations 2 x 20 mm (not threaded)
Materials
Glass reinforced polyester (GRP) Impact resistant to 7nM
Surface resistant to 109 OHMS UV stabilised
Flame retardant / self extinguishing Captive stainless cover screws
Stainless steel earth continuity
plate optional
Specifications
DS and DP Stainless steel control stations
Certification Temperature rating
DP range
Certified for D.I.P. Zones 21 & 22 T6
Approvals Degree of protection
Cert. of conform Aus Ex 2484X IP 65/IP 66
Standards Aus. AS 2236
Int. standards IEC 61241
Rated voltage Rated current
240 V AC 3A
Cable entries Materials
2 x 20 mm 316L stainless steel
Ordering Information
Dimensions (mm)
H W D Weight (kg) Cat. No.
150 110 78 0.05 DP1511 DS range
Specifications
DE control stations
Classification Degree of protection
Group II IP 65
D.I.P. AS 2236, Zone 21, 22 Cat. No. DE1I
Approvals Materials
AUS Ex 699 (DE1)
AUS Ex 1173X (DE2)
AUS Ex 1176X (DE3)
AUS Ex 3277X (DE4)
Standards: AS/NZS61241 IEC 61241
Rated voltage Cable entries
TBA TBA
Note: Custom built Group II D.I.P. control stations are available using enclosure types Cat. No. DE10
DE2, DE3 & DE4, or a combination of enclosures.
O rdering information
Refer
Cat. No. Description Section
DE1I Single pushbutton station 2 and 3
DE10 Single pilot light station 2 and 3
DEJ1 Twin pushbutton station 2 and 3
DE1P Twin pilot light station 2 and 3
DE1A201 Single gang switch 2 pole 2 and 3 Cat. No. DEJ1
DE1A203 Single gang switch 4 pole 2 and 3
Other types
available
Specifications
FC4, and F7D control stations
Classification Degree of protection
IEC 60079-0 IP 66
IEC 60079-1
IEC 61241-0
IEC 61241-1
Approvals Materials
IECEx SIM 07.0001X (FC4) Cat. No. FC4
Exd IIC T6 IP66
Ex tD A21 IP66
IECEx TSA 07.0029 (F7)
Ex d IIB T6 IP66
Ex tD A21 T80 0C IP66
ATEX: Sira 07ATEX1133X (FC4)
II 2 G D
ATEX: Sira 07ATEX1134 (F7)
II 2 G D
Specifications
Specialised equipment
Classification Degree of protection
IEC 60079-0 IP 66
IEC 60079-1
IEC 61241-0
Cat. No. FC4-T
IEC 61241-1
Approvals Materials o 152
IECEx SIM 07.0001X Marine grade aluminium o 7. 130
Exd IIC T6 IP66
2 HOLES
Ex tD A21 IP66 G O VA N
56
Cable entries
TBA
O rdering information
166
Refer
Cat. No. Description Section Page No.
o 94
FC4FT Foot / palm stop switch 4 4-4
FC4-T Thermostat 4 4-5
FC4SS Sail switch 4 4-5 Cat. No. FC4FT
FC41BE6 Bell 4 4-3
FC4A-FS Float switch 4 4-3
Specifications
Classification
Group II D.I.P. Zone 21, 22
Approvals
Subject to housing type
Standards: AS 2236 IEC 61241
Degree of protection
IP 65/66
Cable entries (see ordering information)
Material (see ordering information)
O rdering information
Refer Cat. No. FB1
Cat. No. Description Section Page No.
GL2D Fluorescent lighting 1 1-8
GL3D H.I.D. High bay lighting 1 1-16/1-17
GL5/2 H.I.D. Floodlight 1 1-20/1-21
FB1/FB1S Strobes 1 1-22
FB2 Beacon / Strobe 1 1-22