SAMPLE REPORT FOR PROPERTY F

Surface Regularity Test


Technical Report 34

Description of Works

METHOD: In accordance with TR34, the flatness was measured across a marking of the
grid lines usedwhen carrying out the level survey. The total length of the survey
lines in meters was calculated as the floor area in square meters divided by 10.
The lines were distributed uniformly across the floor where possible with the
total length of runs in each direction being equal.
Summary of FM2 edition 4:
Run Locations on Following Page
Sample Floor Layout for Flatness Survey
Length of Each Run is 15 Rmt.
Each run is labelled with unique name
at start point location.

21000

L- 2

L- 1
T- 1 T- 2

1500
18000
Brick Wall Surveying Area
Property F
Results

Job Name: XXX


TR34 Classification: 4th Edition - FM2

Property F (Total Runs)


7 Readings beyond 95% Total count
96.43% 95% Limit 196 96.43%
0 Readings beyond 100%

Overall Project Results 100.00% 100% Limit 196 100.00%


Property F Graphs
XXX 4th Edition - FM2
TR34 Limits
Property F 100%
Box Area L - 1 95%
8

1
mm

-1

-2

-3

-4

-5

-6

-7

-8
0 3 6 9 12 15 18

Distance (m)
XXX 4th Edition - FM2
TR34 Limits
Property F 100%
Box Area L - 2 95%
8

1
mm

-1

-2

-3

-4

-5

-6

-7

-8
0 3 6 9 12 15 18
Distance (m)
XXX 4th Edition - FM2
TR34 Limits
Property F 100%
Box Area T - 1 95%
8

1
mm

-1

-2

-3

-4

-5

-6

-7

-8
0 3 6 9 12 15 18
Distance (m)
XXX 4th Edition - FM2
TR34 Limits
Property F 100%
T - 2 95%
Box Area
8

1
mm

-1

-2

-3

-4

-5

-6

-7

-8
0 3 6 9 12 15 18

Distance (m)
Conclusion:

From the Property F readings noted and calculated, it can be seen that the floor area surveyed complies with the
required FM2 classification as defined in table of Fourth Edition of the Concrete Society's Technical Report Number
34.
END OF REPORT