Feasible Study on Loading Test Location for SHP (Total 3 nos.

)
KTN-3-R-DH001
RL:-29.81

KTN-3-R-DH002
RL:-38.82

KTN-3-R-DH003
RL:-38.31

2.0 m
P2-BD2
RL:-35.28
1st Largest Loading

7.0 m
in Block 11-12
4790
P2-BD3(S/P)
P2-BD4
RL:-40.61 ,
2nd Largest Loading
RL:-41.43
P2-BD5
RL:-36.72

in Block 11-12
P 2- B D 1
4740 P2-BD6
RL:-35.57 RL:-38.74

7.0 m

P2-BD7
RL:-32.36

7.0 m
P2-BD8 Deepest Pile in
RL:-36.37 P2-BD9
RL:-38.61
P 2 - B D 10
R L : - 4 5. 4 9 Block 11-12 P2-BD11(S/P)

-52.89mPD R L : - 4 1. 4 9

BHB2 P2-BD12
R L : - 3 4. 1 6
RL:-40.74 BHB4
RL:-33.90

BHB5
RL:-46.29
BHB9
RL:-40.26
KTN-3A-SF-DH010(P)
LEGEND
R L : - 31 . 85

Largest Loading Not recommend for selected as


in Block 7-8 P2-BD13

P 2- A D1
RL:-38.47
R L : - 3 2. 8 0
loading test piles due to adjacent
4460 to site boundary/ slope

P2-BD14(S/P)
Not recommend for selected as
R L : - 2 9. 7 2
P2-BD15
RL:-45.40
P2-BD16
RL:-50.84
loading test piles due to cut-slope
P2-BD17
R L : - 4 4. 5 3 area
P2-BD18(S/P)
R L: - 38 . 46

Deepest Pile 1st Largest Loading BHB14


RL:-40.45 Largest Loading of each Block
in Block 9 / in Block 11-12 BHB10
RL:-48.44

-57.015mPD 3600
Deepest pile of each Block
BHB6
RL:-51.73

P2-AD2
RL:-47.80
P 2- B D 19
R L: - 2 7. 3 2

7.0 m
BHB1
R L: - 4 1 . 72

P 2- B D 23
P 2 - B D 22 R L: - 49 . 7 2
RL:-49.84

P 2 - AD 3
RL:-50.51

P 2- B D 20
R L: - 3 4 . 87

P2-BD21 P2-BD24(S/P)
RL:-54.65 R L : - 4 4 . 04

Deepest Pile
KTN-3A-SF-DH013(P) in Block 7-8
R L : - 31 . 84
P2-BD25
RL:-30.87
-62.5mPD
KTN-3A-SF-DH007
R L: - 4 5 . 3 5
BHB11
P2-BD26
RL:-55.82 R L: - 51 . 68

BHB13
BHB7
R L : - 38 . 5 2
R L: - 5 3 . 40

P2-BD27(S/P)
BHB15
R L : - 4 2. 1 7
R L : - 3 9. 3 8

7.0 m
P2-BD29(S/P)
R L : - 47 . 2 7

P2-BD28
R L: - 3 3 . 38
Deepest Pile
in Block 10-11
-58.74PD

DATE OF ISSUE :
7.0 m ORIGINAL
ENDORSED 07/2023
P2-BD30(S/P)
(Senior Design Professional) SIGNED
R L : - 4 4. 9 5

ORIGINAL
CHECKED 07/2023
(Design Professional) SIGNED
ORIGINAL
DRAWN 07/2023
(Drawing Office Team Leader) SIGNED

Largest Loading
in Block 10-11 7.0 m DESIGN AND CONSTRUCTION OF
3960 PUBLIC HOUSING DEVELOPMENT
AT KWU TUNG NORTH AREA 19 PHASE 2

OTHERS:
C.E.
P 2- B D 31
P2-BD32
R L : - 26 . 8 3
RL:-27.59
BHB8

BHB12
RL : - 49. 80

B.S.E.
G.E.
7.0 m
BHB3
R L : - 23 . 67

FILE / OFFICE
IOW/COW
7.0 m

P 2- B D 3 4 P2-BD35
P2-BD36(S/P)
R L : - 28 . 0 5 RL:-27.33
R L : - 4 8. 5 4

Q.S.
R.E.
P2-BD33
R L: - 3 0 . 23

Contractor
Architect
KTN-3-SF-DH005(P)
RL:-18.01

COPY
FOR
COUNTERCHECKED

Updated on 15-03-2024