Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FROM VACUUM 1&2, M-POOL, 1-1/4" PPR PIPE

FROM MAIN DRAIN 1 & 2, M-POOL - 2" PPR PIPE FROM VACUUM, K-POOL - 1-1/4" PPR PIPE
FROM SKIMMER 1 & 2, M-POOL - 2" PPR PIPE FROM MAIN DRAIN, K-POOL - 2-1/4" PPR PIPE
FROM SKIMMER 3 & 4 M-POOL - 2" PPR PIPE FROM SKIMMER, K-POOL - 2" PPR PIPE
BV BV BV BV

TO INLET 1 - 2 , K-POOL - 1-1/2" PPR PIPE


BV BV BV BV

TO WATERFALL , K-POOL - 2" PPR PIPE


TO INLET 9 - 12 , M-POOL - 2" PPR PIPE

TO INLET 5 - 8 , M-POOL - 2" PPR PIPE

TO INLET 1 - 4 , M-POOL - 2" PPR PIPE

TO INLET 3 - 4 , K-POOL - 2" PPR PIPE


1-HP KP PUMP 1
2-HP MP PUMP 1 1-HP KP PUMP 2
2-HP MP PUMP 2
BV BV BV BV
BACKWASH TO DRAIN BACKWASH TO DRAIN
NRV NRV
BV BV
MP FILTER KP FILTER
BV

3-WAY VALVE #1 #1 3-WAY VALVE BV


BV

BV
BV
BV

NRV
3-WAY VALVE BV BV 3-WAY VALVE
MP FILTER KP FILTER
#2 #2 NRV
BACKWASH TO DRAIN BACKWASH TO DRAIN
SWIMMING POOL PUMP ROOM PIPING LAYOUT 15
SCALE: 1 : 100 A-100
DESIGNER: CIVIL ENGINEER: ARCHITECH: PROJECT: DRAWN: CHECKED: APPROVED:
SWIMMIMNG POOL AND KIDDIE POOL
KASINNAHAN HOTEL AND RESTO, ISABELA CITY
OWNER: SHEET CONTENT: DRAWING NO.: REVISION:
PROJECON DC
ENGINEERING SERVICES
''Build to deliver a better world''
E-Mail: projecondc17@gmail.com Tel.: 0063 939 407 2997
A-102