Professional Documents
Culture Documents
Designing Safe Rooms
Designing Safe Rooms
R
ecent devastating tornados
in Missouri, Alabama and Port
Angeles
TORNADO ACTIVITY IN THE UNITED STATES*
Summary of Recorded F3, F4, & F5 Tornadoes
Mississippi have prompted Seattle
Per 3,700 Square Miles (1950 - 1998)
school superintendents, public of- Olympia
Spokane Kalispell
Great Falls
Minot
Billings Montpelier
Challis
Medford Minneapolis
grants.
Bernadino
Albuquerque Memphis
San Oklahoma City Fort Smith Columbia
Diego Amarillo
Phoenix Little
Design Challenges
Design requirements create many F Scale Number of Tornados Percentage of Total
potential challenges for the secondary F0 20,728 43.68%
use of the safe room. Challenges in-
clude daylighting, acoustics and over- F1 16,146 34.03%
all aesthetic appearance. All openings
and penetrations in the building enve- F2 7,944 16.74%
lope are required to meet the missile-
F3 2,091 4.41%
impact criteria for the design wind
event. F4 491 1.03%
Providing glass that meets the re-
quirements can be cost-prohibitive, F5 50 0.11%
but providing standard storefront
Total 47,449
glass with FEMA-rated door assem-
blies to act as storm shutters can re- Source: FEMA, 2008
duce the budget impact of providing
natural light. The hard materials such
Designing safe-room doors and windows often design criteria due to the extreme
loads that are required. For example, a
frustrates designers. double door usually cannot be placed
in a single panel, as the door must be
centered on a panel joint. In addition,
construction materials grows in im- Typical Construction
specific considerations are required
portance.Variations of CMU construc- Building-envelope requirements
for the uplift of the roof members to
tion can be used, or precast concrete, lead to facilities often constructed
the wall panels and for transfer of the
which provides a great array of aes- with precast concrete wall panels and
uplift and shear loads into the founda-
thetic options including different col- double-tee girders for roof structures.
tions.
ors, forms, and textures, as well as Historically these have provided a
While safe rooms can be located
veneered materials, such as brick or cost-effective method of construction.
immediately adjacent to existing
stone. Specifying certified precast concrete
structures, it is recommended that
LEED certification, a growing de- ensures a known quality-control pro-
they be separated from adjoining facil-
sire for school administrators, creates cess will be used (a requirement) and
ities with a non-FEMA rated connec-
another challenge for safe-roof de- construction time can be better mini-
tor installed between the buildings.
sign. While certain aspects of these mized and quantified. Another popu-
This can eliminate the use of proper-
designs can negatively impact the lar approach is concrete masonry-unit
ty-line foundations and avoid impact-
ability to meet LEED standards, such walls with a concrete-topped system
ing the existing foundation, as the
as daylighting, others offer huge ad- of steel beams and metal deck. Other
safe-room foundation loads are typi-
vantages, such as energy efficiency construction types have been used,
cally three to five times higher than
through thermal mass, local materi- including monolithic domes and cast-
traditional structures. With a creative
als, and recycled content. As with in-place concrete, but they are not as
design, the connector can be used to
any construction project, a FEMA common.
allow natural light and additional ar-
tornado safe room can achieve LEED When designing with precast con-
chitectural features that complement
certification with careful planning. A crete, the design team should consult
the safe room’s appearance and help
recently-completed safe room in the with the local precaster prior to final-
it fit in with nearby buildings. The safe
Midwest, which Toth and Associates izing the layout. While the design pro-
room also must be designed for the
was involved with, is in the process of cess is the same as with a traditional
collapse load of all non-FEMA 361
being certified by LEED, with a Gold project, typical connections or layouts
buildings located nearby.
rating expected. may not work under the safe-room
Secondary Uses
A safe room’s main function is to efit is that a refuge is specifically cre- project is higher than typical construc-
protect occupants from extreme en- ated for building users and the com- tion due to the life-safety protection
vironmental events, but the second- munity rather than requiring them to being provided. For large new build-
ary use can be just as important to gather in an area simply designated ing projects, however, the percent in-
the owner, especially in mitigating as least likely to fail. crease in overall project cost is quite
budget costs. Secondary uses of safe small. Many safe rooms constructed
rooms include (but are not limited to) Safe Room Costs as part of a new school add only 1 to
gymnasiums, cafeterias, band rooms, Many factors influence the cost of 2% to the total project cost when the
classroom buildings, park facilities, a safe room. Key factors include num- safe room is included in the design
and community centers. ber of uses, design simplicity, wind- process from the beginning.
Integrating a secondary use pro- speed design, debris-impact criteria,
vides multiple benefits. The safe room exterior wall and roof materials, and Federal Grants Available
can be used every day and not forgot- location with regard to foundation Federal-grant opportunities can
ten, ensuring everyone is comfortable and site-development requirements. help cover costs for the design and
Costs generally range from $150- construction of tornado safe rooms
$240 per square foot, depending on along with hurricane shelters. Grants
geographic location and the second- can cover up to 75% of the FEMA-
Federal-grant ary use. approved costs of a safe room. While
The absolute range is much wider; various federal funding opportunities
opportunities can help safe rooms have been constructed for exist, there are two main avenues for
as little as $90 per square foot and as public entities to pursue funding.
cover costs for the much as $490 per square foot. The The first is the Pre-Disaster Mitiga-
increase in cost for constructing a tion (PDM) grant program, a nation-
design and construction structural system and building enve- ally-competitive funding source. The
lope that withstands 250-mph design other is the Hazard Mitigation Grant
of safe rooms. wind speed rather than a standard 90- Program (HMGP), which is competi-
mph design wind speed is about 20% tive at the state level and is funded
with its use and knows its location. to 32%. based on declared disasters within a
Specific maintenance costs are elimi- The impact on overall project cost state. To determine if funds are avail-
nated, as the safe room is part of ev- is much higher for standalone safe able at a specific project site, contact
eryday operations. Incorporating the rooms than for safe rooms incorporat- the State Hazard Mitigation Officer
facility into a larger project can help ed into larger projects. The most cost- or a local grant writer specializing in
reduce out-of-pocket cost and possi- effective means of constructing a safe these grants.
bly allow for other construction that room is to incorporate it into a new fa- Earlier this summer, our engineer-
could not be funded if a standalone cility in the initial planning stages. The ing firm created bid information for a
safe room was created. The key ben- relative cost per square foot for safe tornado safe room designed to meet
rooms included as a part of a building
FEMA 361 as part of a new middle $1.79 million, or $149.17 per square $60 per square foot. This represents
school being constructed in the Mid- foot, while the bid alternate was a cost savings of $664,000 to the
west. The safe room is approximately $1.38 million, or $115.00 per square owner over conventional construction
12,000 square feet, and will be con- foot. To offset the increased construc- for this same facility while providing
structed with 12-inch-thick precast tion cost for the safe room, the school added benefit of a community safe
concrete wall panels and a double-tee district applied for a safe-room grant room designed to withstand 250-
roof structure. A bid alternate also under HMGP. The grant will cover up mph wind speeds. The owner’s share
was provided that consisted of 8-inch- to 75% of FEMA-approved construc- for the project is estimated to be ap-
thick precast concrete wall panels tion items. proximately 40% of the overall project
with a bar-joist and acoustical-deck It is estimated that the school dis- cost, which is typical for similar proj-
roof system. trict’s portion of the safe-room con- ects.
The low bid for the safe room was struction will cost about $716,000 or These grants make a compelling
case for architects to broach the sub-
ject of providing a tornado safe room
More Information within a school project if administra-
tors don’t request it on their own.
To learn more about requirements for FEMA safe rooms, visit: Safe-room grants not only can reduce
http://www.fema.gov/plan/prevent/saferoom/index.shtm construction costs, allowing funds to
be shifted to other areas, but they
http://www.fema.gov/plan/prevent/saferoom/fema361.shtm help create a safer structure provid-
ing added benefits to the community.
To learn about grant programs, visit: Being aware of design and funding
http://www.fema.gov/plan/prevent/saferoom/srfunding.shtm techniques provides designers with
a significant value-added design ele-
ment to offer to clients. ■