INSPECTION & TESTING REPORT


Client PCMTBE PO No.
Tag No. PV‐13711 Date 2/11/23
Location Field Flaring Site Item No.

Valve Description 18” #150 Butterfly Valve RF


Body Material WCB Seat Material Metal+PTFE
Valve Model No. / Serial No. 801X‐405/35‐81
Manufacturer Xomox
Heat No./Traceability No. L1900272
Actuator Bettis
Actuator Model No. / Serial No. G01010‐SR3

External Visual Inspection:


‐ There are no signs of damage externally
‐ Valve & Actuator was stuck halfway – Either Valve or Actuator problem.

Stroking Test:
‐ The actuator needs to be forced air by 7 bar for it to be able to completely OPEN & CLOSE
‐ Spring are not able to open the valve
‐ Air at 4 bar are insufficient (during supply, we sized the air at 4 bar only is enough)

Stroking Test without Valve:


‐ Actuator are able to stroke open & close normally. No abnormality during travel.
COSMOS Integrity Engineering Sdn Bhd [1029473-A]
B58 1st Floor, Lorong IM8/33, Taman Mahkota Putra,
Indera Mahkota 8, 25200 Kuantan, Pahang Darul Makmur, MALAYSIA
Tel : 09-572 9180 / 09-572 9268 Fax: 09-572 9268

Conclusion: The actuator are in good condition, The valve seems to be the reasons why we
could not stroke properly(stuck).

Way Forward: Cosmos will quote the sparepart of the valve. During valve inspection &
servicing only we will know the reason why the valve stuck.