Meter&Control - ST300 - Modular Meter

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Modular meters

ST300

Three-phase modular meter for commercial and industrial


consumers with plug-in communication and switching modules

ST300 is three-phase modular smart meter designed for measure- module (CMxyS - PLC or GPRS/3G communication) and switching
ment of active and reactive energy of commercial and industrial module (SD30S) via M-Bus connection. Both plug-in modules are
consumers, with direct, semi-indirect and indirect grid connection. simply mounted under the terminal cover. ST300 is compliant with
ST300 can also be used in single-phase networks. AMI system inte- all relevant standards and regulations.
gration is enabled by connecting optional plug-in communication

Key features

— Measurement of electrical values — Event logs


— Integrated Real-time clock with DST — Measurement of energy quality
— Flexible tariff policy with up to 4 tariffs — Firmware update
— Maximum demand — Functional inputs / outputs
— RS485 port — Data security
— Optical port
— DLMS/COSEM
— Fraud detection
— No-power reading and parametrization
— Billing profile / profiles
— Load profiles
— Power limit
— Code red
Technical data ST300

Measurements connection; 40 000 imp/kWh (kvarh) i.e. 15-minute average load profile (1 Firmware update
• Measurement of power and energy in for VT connection channel) is stored for 45 days • Enabled locally or remotely with no
both directions and absolute values • 2 push buttons on the meter cover impact on accuracy, parameter config-
(A+, A-, |A|, R+, R-, optionally R1, R2, • OBIS data ID code: IEC62056-61 Log books uration or billing data
R3, R4) • Standard log book with up to 200 logs
• Active energy measurement – Index Optical port and states
classes 0.2s, 0.5s or 1, reactive energy • Physical layer according to IEC 62056-21 • Quality event log book No-power reading
measurement - class 2 or 3 • DLMS/COSEM communication • Fraud detection log book • Local reading via display or optical
• Measurement of voltages and cur- protocol • Disconnector control log book port
rents by phases, frequency and power
factor Electrical ports (physical layer) Energy quality measurement Integration into AMI system
• Port A: RS 485 for communication with • Maximum and minimum voltage Communication with AMI system
Maximum demand AMI Center (active) registration • ST100 is ready for addition of plug-in
• Programmable maximum demand • Port B: M-Bus master for communi- • Voltage variation registration communication module (PLC or
integration period is generated by cation with the switching module and • Maximum current registration GPRS/3G) on port A
internal clock (typically 5, 10, 15, 30 or other energy meters compliant with • Outage registration (short outage – Load management
60 minutes) EN 13757-2 Event counter, long outage – Long • ST100 is ready for addition of plug-in
power interruption log) switching device on port B
Multi-rate registration and TOU Inputs and outputs (optional) • Under-voltage and over-voltage meas- • Switching device in accordance with
• Programmable tariff structure • 2 control inputs for tariff control urement and registration in Quality IEC 62055-31, UC2/UC3
(up to 4 tariffs) • 2 tariff outputs (100 mA) Event log book
• Up to 4 seasons and 4 weekly • 2 pulse outputs Data protection
changeovers • 1 control output with bi-stable relay (6A) Fraud detection • Local parameterization is protected
• Up to 9 day types and 32 holidays • Detection of meter cover opening / by multi-level passwords and push
• Up to 10 daily changeovers Communication protocol closing button positioned under terminal
• Optical port and port A: DLMS • Detection of terminal block cover block cover
Internal Real-time clock with DST (IEC 62056-46) opening / losing
• In accordance with IEC 62054-21 • Port B: M-Bus (EN 13757-3) • Detection of wrong authorization for Meter quality
• Automatic DST switching (optional) meter parameterization • High accuracy and long term stability
• Battery backup supply, optionally Billing profiles • Detection of strong magnetic field of metering elements. No recalibra-
super-capacitor • Billing profiles (registered energy and • Detection of neutral conductor tion required during meter lifetime
maximum demand values by tariffs) interruption • High meter reliability
Visual communication with meter are generated and stored for the last • Recording of events in the Fraud • High immunity to EMC
• LCD and display modes according to 18 billing intervals event log book
VDEW specifications Current terminal block
• Programmable selection of data and Load profiles Power limiting (optional) • For current up to 60 А: for all types of
display sequence • 4 load profiles with 7 channels each • Power or current limiting of electricity conductors up to 16 mm2
• LED: 1000 imp/kWh/kvarh; 10 000 • Independent, programmable registry consumers by defining the limit value • For current up to 120 А: for all types
imp/kWh/kvarh for direct and CT intervals (5-60 minutes, 1-24 hours) of power or current in the dedicated of conductors up to 35 mm2
• Sufficient memory (4 320 registries, meter register
• Dedicated log book (10 switching Compact meter case
Accuracy class module disconnections / connections) • High quality, transparent, reinforced,
active energy 0.2s, 0.5s or 1 self-extinguishing polycarbonate case
Code Red (optional) • IP54 protection against water and
reactive energy 2 or 3 • Enables synchronous power limiting dust (in accordance with IEC 60529)
Nominal and maximum current of groups (large number) of users in
direct connection 5 (60) A, 5 (120) A case of irregular situation on distribu-
tion network (e.g. lack of power)
transformer connection 1 (6) A, 5 (6) A
Minimum current Imin 0.05 In
Nominal voltage, Un 3x230/400 V, 3x400 V, 3x57,7/100 V, 3x100V,
230 V
Voltage range 0.8 Un – 1.15 Un
Frequency 50 Hz
Ports and protocols
optical port IEC 62056-21 (physical layer)
IEC 62056-46 (DLMS) communication protocol
154,5

RS485
142

electrical port A
IEC 62056-46 (DLMS) communication protocol

electrical port B wired M-Bus master (EN 13757-2)


EN 13757-3 communication protocol
272,9

Comm. module (optional) PLC, GPRS/3G


Switching module (optional) 3x230 V (3x90 A; 3x120 A), IEC 62055-31, UC2/UC3
Self-consumption <2W
Insulation voltage 4 kV, 50 Hz, 1 min
127,2

Shock voltage 6 kV; 1.2 / 50 µs


Operational temperature range -40 °C - +70 °C
Storage temperature -40 °C - +80 °C
IP protection IP54, according to IEC 60529
Dimensions 273 x 177 x 91 mm 150 90,8
Weight 0.9 kg 178,9

Meter&Control d.o.o. | Science Technology Park Belgrade


Veljka Dugoševića 54 | 11050 Belgrade | Serbia
office@meterandcontrol.com | www.meterandcontrol.com Solutions for smart energy management
We strive to make the content of promotional materials as timely and accurate as possible. Meter&Control makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of, and expressly
disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third party rights, title,
merchantability, and fitness for a particular purpose, is given with respect to the content of these promotional materials. © Copyright 2022 Meter&Control. All rights reserved. 09/2022

You might also like