Professional Documents
Culture Documents
Flow Sizing Examoles
Flow Sizing Examoles
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Fluid description
Solid content 2 %
Medium character Clean
Abrasivity Not abrasive
Conductivity more than 50 µS/cm
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian
Calculated results
Density nom. 998 kg/m3 Pressure nom. 2.1 bar_g
Viscosity nom. 1 cP Temperature nom. 20 °C
Sound velocity nom. 1 487 m/s
Vapor pressure nom. 0.0199 bar_a
Thermal expansion coeff. Beta P 0.0005
Viscosity coefficient AL -6.179
Viscosity coefficient BL 1 811.51
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Chart Sheet
Flowmeter: Promag 53W Generation: 2 Device model: 0
Flow Principle Electromagnetic Fluid Water, Waste Water City/Effluent/Sewage
Meter Size DN 500 Pressure 2.1 2.1 3 bar_g
Operating range min. 25 m3/h Temperature 20 °C
Operating range max. 6 600 m3/h Density 998 kg/m3
Viscosity 1 cP
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Corrosion Information
General Parameters
Fluid Water, Waste Water City/Effluent/Sewage Abrasivity Not abrasive
State Liquid
Character Clean Flow Principle Electromagnetic
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).