Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Data Sheet

Applicator Sizing - Condensed (Flow)


Project
Project
C.Project No.
Customer:
TAG FIT W001 A
Timestamp ---
Review number ---
Sales order number
Contact person
eMail:
Phone
Fax

General Parameters Operating Conditions


Fluid Water, Waste Water City/Effluent/Sewage minimum nominal maximum
State Liquid Requested Flow 750 750 1 500 m3/h
Character Clean Pressure 2.1 2.1 3 bar_g
Abrasivity Not abrasive Temperature 20 20 20 °C
Fluid Group (PED) Dangerous Fluid (Fluid group 1) Density 998 998 998 kg/m3
Fluid type Newtonian Viscosity 1 1 1 cP
Atmospheric Pressure 1.0132 bar_a Vapor Pressure 0.0199 0.0199 0.0199 bar_a
Standard EN/DIN/ISO Design pressure 2.1 3 bar_g
(min/max)
Design Temp. (min/ 20 20 °C
max)

Flowmeter Sizing and Calculated Results


Flowmeter Promag 53W Generation: 2 / minimum nominal maximum
Model: 0 Requested Flow 750 750 1 500 m3/h
Flow Principle Electromagnetic Velocity 1.096 1.096 2.192 m/s
Extended Order Code 53W5H-HE Pressure loss n.a. n.a. n.a. mbar
Meter Size DN 500 Measurement error 0.38 0.38 0.29 %
Operating range min. 25 m3/h Volume***
Operating range max. 6 600 m3/h Reynolds No. 538 064 538 064 1 076 129
Material (sensor) * Hard-Rubber-Liner (0...+80°C)
Process connection* PN 6 EN 1092-1, ST 37-2 Flange
PED category ** : In observance of the selected process
conditions and medium, Applicator categorizes
this application as PED Cat I. Due to guidelines
for low-voltage, Applicator suggests an
instrument without PED option.

*The user is responsible for the selection of process-wetted materials


in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Print date: 17.10.2018 02:13 PM -1/6-


Applicator®: 11.03.04 / 181
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : FIT W001 A


Timestamp: --- Review number: ---
Sales order number:

Fluid properties sheet


Fluid
Fluid name Water, Waste Water City/Effluent/Sewage State Liquid
Chemical formula H2O + Organic waste Calculation standard Supporting Points

Fluid description
Solid content 2 %
Medium character Clean
Abrasivity Not abrasive
Conductivity more than 50 µS/cm
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Basic fluid parameters


Tc (Critical temperature) 374.1 °C Tm (Melting point) 0.04 °C
Pc (Critical pressure) 221.2 bar Tb (Boiling point) 100 °C
Heating value 0 kWh/Nm3
Temperature / Viscosity Temperature / Density
Temperature Viscosity Temperature Density
1 20 °C 1 cP 1 20 °C 998 kg/m3
2 80 °C 0.35 cP 2 80 °C 970 kg/m3
Temperature / Heat capacity
Temperature Thermal capacity
1 10 °C 0 kJ/(kg*K)
2 100 °C 0 kJ/(kg*K)

Calculated results
Density nom. 998 kg/m3 Pressure nom. 2.1 bar_g
Viscosity nom. 1 cP Temperature nom. 20 °C
Sound velocity nom. 1 487 m/s
Vapor pressure nom. 0.0199 bar_a
Thermal expansion coeff. Beta P 0.0005
Viscosity coefficient AL -6.179
Viscosity coefficient BL 1 811.51

Reference values: Normal conditions (SI): Standard conditions (US):


Atmospheric pressure 1.0132 bar_a Atmospheric pressure 1.0132 bar_a

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Print date: 17.10.2018 02:13 PM -2/6-


Applicator®: 11.03.04 / 181
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : FIT W001 A


Timestamp: --- Review number: ---
Sales order number:

Compare sensors sheet


General Parameters
Fluid Water, Waste Water City/Effluent/Sewage
State Liquid
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Sizing and Calculated Results


Alternative 1 Current Alternative 2
Flowmeter Promag 53W
Generation/Device model 2/0
Flow Principle Electromagnetic
Meter Size DN 500
Operating range min. 25 m3/h
Operating range max. 6 600 m3/h
Velocity at req. Flow min. 1.096 m/s
Velocity at req. Flow nom. 1.096 m/s
Velocity at req. Flow max. 2.192 m/s
Meas. error Vol. at req. Flow min.*** 0.38 %
Meas. error Vol. at req. Flow nom.*** 0.38 %
Meas. error Vol. at req. Flow max.*** 0.29 %
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Print date: 17.10.2018 02:13 PM -3/6-


Applicator®: 11.03.04 / 181
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : FIT W001 A


Timestamp: --- Review number: ---
Sales order number:

Compare sizes Sheet


General Parameters
Fluid Water, Waste Water City/Effluent/Sewage
State Liquid
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flow meter Promag 53W Promag 53W Promag 53W
Generation/Device model 2/0 2/0 2/0
Flow Principle Electromagnetic Electromagnetic Electromagnetic
Meter Size DN 450 DN 500 DN 600
Process connection* PN 6 EN 1092-1, ST 37-2 PN 6 EN 1092-1, ST 37-2 PN 6 EN 1092-1, ST 37-2
Operating range min. 20 25 30 m3/h
Operating range max. 5 400 6 600 9 600 m3/h
Velocity at req. Flow min. 1.389 1.096 0.752 m/s
Velocity at req. Flow nom. 1.389 1.096 0.752 m/s
Velocity at req. Flow max. 2.778 2.192 1.504 m/s
Pressure loss at req. Flow min. mbar
Pressure loss at req. Flow nom. mbar
Pressure loss at req. Flow max. mbar
Meas. error Vol. at req. Flow min.*** 0.34 0.38 0.47 %
Meas. error Vol. at req. Flow nom.*** 0.34 0.38 0.47 %
Meas. error Vol. at req. Flow max.*** 0.27 0.29 0.33 %
Reynolds No. 605 784 538 064 445 670
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Print date: 17.10.2018 02:13 PM -4/6-


Applicator®: 11.03.04 / 181
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : FIT W001 A


Timestamp: --- Review number: ---
Sales order number:

Chart Sheet
Flowmeter: Promag 53W Generation: 2 Device model: 0
Flow Principle Electromagnetic Fluid Water, Waste Water City/Effluent/Sewage
Meter Size DN 500 Pressure 2.1 2.1 3 bar_g
Operating range min. 25 m3/h Temperature 20 °C
Operating range max. 6 600 m3/h Density 998 kg/m3
Viscosity 1 cP

Flow rate (m3/h) Measurement error Volume(%)***


750 0.383
825 0.366
900 0.352
975 0.34
1 050 0.33
1 125 0.322
1 200 0.314
1 275 0.307
1 350 0.301
1 425 0.296
1 500 0.291

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Print date: 17.10.2018 02:13 PM -5/6-


Applicator®: 11.03.04 / 181
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : FIT W001 A


Timestamp: --- Review number: ---
Sales order number:

Corrosion Information
General Parameters
Fluid Water, Waste Water City/Effluent/Sewage Abrasivity Not abrasive
State Liquid
Character Clean Flow Principle Electromagnetic

Interpretation of Data, (M) Material:


A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown

Interpretation of Data, (P) Plastics:


A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum20°C nominal : 20°C maximum : 20°C
(M) Titanium Grade 2 A A A
(P) EPDM A A A
(P) Hard Rubber A A A
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) Natural Rubber A A A
(P) PFA A A A
(P) PTFE A A A
(P) PU A A A
(P) PVC A A A
(P) PVDF A A A
(M) Platinum A A A
(P) Polyamid A A A
(P) Silicon A A A
(M) Stainless steel 304/1.4301 A A A
(M) Stainless steel 316L/1.4404 A A A
(M) Stainless steel 316L/1.4435 A A A
(M) Stainless steel 316L/316/1.4404 A A A
(M)Tantalum A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Print date: 17.10.2018 02:13 PM -6/6-


Applicator®: 11.03.04 / 181

You might also like