PRODUCT INFORMATION
KEY FEATURES
Measurement Inputs / Outputs Configuration Physical Dimensions Tamper Detection & Alarms
• Class 1 & Class 2 (MID Class B & • Up to 4 I/O Total in 3 Isolated • Standard Version: Approx. • Provision for Sealing with
Class A) Groups (Maximum 2 Relay Outputs) 292.5mm (L) x 175mm (W) Conventional Wire or Plastic Seals
• Compliance with IEC 62052-11, • Options Include: Passive/Active x 94mm (D) • Bypassing Current & Reverse
62053-21, 62053-23 Inputs, S0/BOSFET/Relay Outputs • Weight: Approx. 2 kg for WC, Current
• Compliance with AS 62052.11, • Passive Input Voltage: 5V, 12V, 48V, Approx. 1.8 kg for CT • Advanced Tamper Detection and
62053.21, 62053.23 110V, 240V Logging
Time Clock & Calendar
• Active Input Voltage: 12V • Pre-programmed Alarms for Meter
Voltage & Power Supply • Accuracy (internal) within 15
• BOSFET Output: 240V, 100mA Self-check
• Nominal Voltage: 220V – 240V Seconds per Month
maximum • Alarms Trigger LEDs, Enunciators,
• Operating Range: 180V – 290V • Backup Time of 10 Years without
• S0 Output: 27V, 27mA maximum Relay Outputs or Comms Event
Power (Lithium Battery)
• Burden: <10VA/phase • Relay Output: 240V, 5A/2A • Alarms are Stored in Event Logs
@ Vn (3 Phase) • Supports Daylight Saving Time
• 2 LED Indicators, Independent of • Supports Gregorian or Persian Communications
• Frequency Range: 45Hz – 65Hz I/O Calendars • 3 Independently Working
Current • Programmable Output Pulse Width:
Communication Ports
1ms to 100ms Time of Use
• CT Range: 1/6A, 5/20A • Optical Port: FLAG (IEC 62056-21)
• Up to 8 Rates plus Unified Rate
• CT Limit: 20 times Imax for Environmental or ANSI Type 2 (ANSI C12.18)
0.5 seconds • Up to 32 Separate Import &
• Operating Range: -25˚C to +60˚C • RS-232 with Modem Power Supply
Export Registers
• WC Range: 5/100A, 10/100A • Limit Range: -40˚C to +70˚C (2G/3G Supported)
• Daily, Weekly, Monthly, Yearly
• WC Limit: 30 times Imax for 0.5 • Storage Range: -40˚C to +80˚C • RS-485 Multi-drop (2 or 4 Wire
& Special
cycles 7000A for 3 cycles RJ45 or 2 Wire Screw Terminal)
• Relative Humidity: Up to 75% mean, • Up to 200 programmable
• Burden: <0.5VA/phase or second RS-232
95% non-condensing for 30 days Special Days
• UDP/IP/PPP/GPRS Capable
Measured Energy Values • Ingress Protection: IP54, UL50 (3R) • Up to 61 Previous Periods plus
• Compatible with Zigbee & MV-90™
• 3 Element 4 Quadrant • Salt Spray Resistant Period Totals
(IEC 60068-2-11) • Block or Rolling Maximum Demand Battery Options
• Import/Export Wh, varh and VAh
• Per Quadrant Wh, varh and VAh Load Survey / Profile • Energy, Pulsing Inputs • Internal Battery
• Absolute Wh, varh and VAh • Time of Maximum Demand • Replaceable External Battery
• AMI Ready
• Phase A,B,C and Total • Up to 2.1 Megabytes of Non-Volatile Large LCD Display Software
Memory
Other Measured & • Large 7-Segment Display • EDMI EziView Software Available
Displayed Values • Over 3600 Days (10 Years) Storage • Display Digit Size: 10.7mm (H) for Meter Programming & Reading
(2 Channels, 30-Minute Intervals) (Windows Vista/XP/2000)
• Power: W, var, VA, Vrms, Irms • Up to 60 User-Defined Screens of
• Up to 32 Channels any Meter Parameter • EDMI MultiDrive Software Available
• Power Factor, Frequency,
• Intervals Programmable from 1 to • Definable Enunciators for Large Scale AMI & AMR
Phasor Angles
60 Minutes Solutions (Windows Vista/XP/2000)
• Display Available even without
Power Quality Indication • 2 Independent Surveys Mains Power • Supported by Many Popular
• Total Harmonic Distortion (THD) • Energy, Instantaneous Readings, Third-party Multi-vendor
• Unbalance (Sequence Pulsing Inputs as Channel Sources Security AMR Systems
Components) • Ability to Store Average • Multi-level Security (Username &
• Waveform Download /Minimum/Maximum Values for Password including Encrypted
Interval Duration Log-in)
Sag / Swell • Up to 7 Independent Security
• 5 Cycle Resolution Levels
• Records Time/Date/Phase/Duration/ • Up to 6 Individual Users
Average & Worst Excursion
• Programmable Trigger Levels