Submittal AM120JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM120JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 35.00 (MCA)
MFA [A] 50.00
Performance HP 12.00
Cooling [kW] 33.60
Cooling [Btu/h] 114,600
Heating [kW] 37.80
Heating [Btu/h] 129,000

Specifications
EER 4.65
COP 5.11
Power Input Cooling 1 [kW] 7.22
Heating 2 [kW] 7.40
Current Input (Nominal) Cooling 1 [A] 21.10
Heating 2 [A] 21.60 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 1
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) -
Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 2800 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
6.50
Controls
Installation Max. Distance Length [m] 200
The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 220 Refrigerant System
Output [CFM] 7769
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
injected, DC scroll type with soft-start capability.
Motor Output [W] 830.0 x 1
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 12.70 Other Features
Liquid Pipe (Φ, inch) 1/2" Asymmetrical scroll design with rotating compressor operation/priority (where
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum
Gas Pipe (Φ, inch) 1 1/8" duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered
Discharge (Φ,mm) - oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling
Discharge (Φ,inch) - operation.
Sound Sound Pressure 62.0 Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
Sound Power activation or manual activation (with MIM-B14).
81.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 198.5 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 214.5 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 880 x 1,695 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 948 x 1,887 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
Operating Cooling [°C] current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
-5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0
Energy savings options to reduce system energy consumption when average indoor room
temperatures are greater than average indoor set temperatures in heating mode or when
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. average indoor room temperatures are lower than average indoor set temperatures in
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to change
without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM120JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM160JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM160JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 56.10 (MCA)
MFA [A] 63.00
Performance HP 16.00
Cooling [kW] 45.00
Cooling [Btu/h] 153,500
Heating [kW] 50.40
Heating [Btu/h] 172,000

Specifications
EER 4.23
COP 4.89
Power Input Cooling 1 [kW] 10.64
Heating 2 [kW] 10.30
Current Input (Nominal) Cooling 1 [A] 31.00
Heating 2 [A] 30.00 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) (5.09x2)
Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 2200 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
7.70
Controls
Installation Max. Distance Length [m] 200
The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 255 Refrigerant System
Output [CFM] 9005
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 12.70 Other Features
Liquid Pipe (Φ, inch) 1/2" Asymmetrical scroll design with rotating compressor operation/priority (where
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum
Gas Pipe (Φ, inch) 1 1/8" duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered
Discharge (Φ,mm) - oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling
Discharge (Φ,inch) - operation.
Sound Sound Pressure 63.0 Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
Sound Power activation or manual activation (with MIM-B14).
83.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 290.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 298.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,695 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,887 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
Operating Cooling [°C] current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
-5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0
Energy savings options to reduce system energy consumption when average indoor room
temperatures are greater than average indoor set temperatures in heating mode or when
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. average indoor room temperatures are lower than average indoor set temperatures in
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to change
without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM160JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM200JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM200JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 73.00 (MCA)
MFA [A] 90.00
Performance HP 20.00
Cooling [kW] 56.00
Cooling [Btu/h] 191,100
Heating [kW] 63.00
Heating [Btu/h] 215,000

Specifications
EER 4.89
COP 4.96
Power Input Cooling 1 [kW] 11.45
Heating 2 [kW] 12.70
Current Input (Nominal) Cooling 1 [A] 33.40
Heating 2 [A] 37.00 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) -
Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 5600 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
8.40
Controls
Installation Max. Distance Length [m] 200
The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 265 Refrigerant System
Output [CFM] 9358
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 15.88 Other Features
Liquid Pipe (Φ, inch) 5/8" Asymmetrical scroll design with rotating compressor operation/priority (where
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum
Gas Pipe (Φ, inch) 1 1/8" duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered
Discharge (Φ,mm) - oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling
Discharge (Φ,inch) - operation.
Sound Sound Pressure 65.0 Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
Sound Power activation or manual activation (with MIM-B14).
87.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 298.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 317.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,695 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,887 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
Operating Cooling [°C] current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
-5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0
Energy savings options to reduce system energy consumption when average indoor room
temperatures are greater than average indoor set temperatures in heating mode or when
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. average indoor room temperatures are lower than average indoor set temperatures in
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to change
without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM200JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM220JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM220JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 70.00 (MCA)
MFA [A] 80.00
Performance HP 22.00
Cooling [kW] 61.60
Cooling [Btu/h] 210,200
Heating [kW] 69.30
Heating [Btu/h] 236,500

Specifications
EER 3.85
COP 4.40
Power Input Cooling 1 [kW] 16.00
Heating 2 [kW] 15.75
Current Input (Nominal) Cooling 1 [A] 46.65
Heating 2 [A] 45.93 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) -
Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 5600 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
12.50
Controls
Installation Max. Distance Length [m] 200
The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 340 Refrigerant System
Output [CFM] 12007
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 15.88 Other Features
Liquid Pipe (Φ, inch) 5/8" Asymmetrical scroll design with rotating compressor operation/priority (where
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum
Gas Pipe (Φ, inch) 1 1/8" duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered
Discharge (Φ,mm) - oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling
Discharge (Φ,inch) - operation.
Sound Sound Pressure 66.0 / 69.0 Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
Sound Power activation or manual activation (with MIM-B14).
87.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 333.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 355.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,795 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,987 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
Operating Cooling [°C] current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
-5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0
Energy savings options to reduce system energy consumption when average indoor room
temperatures are greater than average indoor set temperatures in heating mode or when
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. average indoor room temperatures are lower than average indoor set temperatures in
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to change
without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM220JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM260JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM260JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 73.00 (MCA)
MFA [A] 80.00
Performance HP 26.00
Cooling [kW] 72.80
Cooling [Btu/h] 248,400
Heating [kW] 81.90
Heating [Btu/h] 279,500

Specifications
EER 3.40
COP 4.55
Power Input Cooling 1 [kW] 21.41
Heating 2 [kW] 18.00
Current Input (Nominal) Cooling 1 [A] 62.43
Heating 2 [A] 52.49 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) -
Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 5600 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
12.50
Controls
Installation Max. Distance Length [m] 200
The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 340 Refrigerant System
Output [CFM] 12007
The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 19.05 Other Features
Liquid Pipe (Φ, inch) 3/4" Asymmetrical scroll design with rotating compressor operation/priority (where
applicable).
Gas Pipe (Φ, mm) 34.92
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum
Gas Pipe (Φ, inch) 1 3/8" duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered
Discharge (Φ,mm) - oil recovery cycles). Oil recovery operation shall not interrupt heating or cooling
Discharge (Φ,inch) - operation.
Sound Sound Pressure 67.0 / 70.0 Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
Sound Power activation or manual activation (with MIM-B14).
88.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 333.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 355.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,795 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,987 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
Operating Cooling [°C] current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
-5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0
Energy savings options to reduce system energy consumption when average indoor room
temperatures are greater than average indoor set temperatures in heating mode or when
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. average indoor room temperatures are lower than average indoor set temperatures in
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to change
without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM260JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM007NN1DCH/AZ Wind-Free 1Way Cassette Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM007NN1DCH/AZ
Features Type
Wind-Free 1Way Cassette

Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60


Capacity Cooling [kW]

Specifications
2.20
Cooling [Btu/h] 7,500
Heating [kW] 2.49
Heating [Btu/h] 8,500 • Compatible with Samsung DVM S, DVM S Water, and DVM Eco
Current Input (Nominal) Cooling 1 [A] 0.23 systems (AM**********/**).
Heating 2 [A] 0.23
• Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR fascia panel)
Power Input (Nominal) Cooling 1 [W] 40.00
Heating 2 [W] 40.00 • Built in condensate pump with maximum 75cm lift, check valve, and
Fan Type Crossflow Fan float switch that disables the indoor unit during overflow detection
Motor (Output) [W] 17 x 1
• Fascia panel shall have LED indicator lights and a motorized louver
Air Flow Rate (High / Mid / Low) [CFM] 212/177/141
Air Flow Rate (High / Mid / Low) [CMM] 6.00/5.00/4.00 • High-voltage terminal block temperature sensor to disable unit in the
Air Flow Rate (High/Mid/Low) [L/S] 100.00/83.33/66.67 event of power connection overheating.
External Static Pressure (Min / Std / Max) [in H20] -
External Static Pressure (Min / Std / Max) [mmAq] • Wind-Free™ function will close the supply air outlet louver while in
-
cooling mode to gently disperse cool air into the space without blowing
External Static Pressure (Min / Std / Max) [Pa] - directly onto occupants. The Wind-Free™ feature is optional and can be
Piping Connections Liquid Pipe (Φ, mm) 6.35 enabled using central or local control options (MWR-SH11N, MWR-
Liquid Pipe (Φ, inch) 1/4" WE13N, AR-EH03E only).
Gas Pipe (Φ, mm) 12.70
Gas Pipe (Φ, inch) • The Wind-Free™ 1-way cassette can be configured for 2-stage
1/2"
operation, cooling the space with the louver open (fixed or swing) until
Drain Pipe (Φ,mm) VP20 (OD 25,ID 20) the room temperature nears set temperature. Once room temperature
Field Wiring Power Source Wire 1.5 ~ 2.5 is near set temperature, Wind-Free™ operation will start automatically,
Transmission Cable 0.75 ~ 1.5 closing the louver and using the face of the fascia panel to gently cool
Refrigerant Type R410A the space with still air*.
Control Method EEV INCLUDED
• The Wind-Free™ panel (PC1NWFMAN) has an integral humidity
Sound Sound Pressure 29.0/26.0/24.0 sensor that will open the louvers for standard cool mode when space
Sound Power 47.0 conditions could potentially cause condensation formation on the
External Dimension (Indoor Unit) Net Weight(kg) 10.00 panel surface.
Shipping Weight (kg) 12.80
Net Dimensions (WxHxD) (mm) Construction
970 x 135 x 410
Insulated, HIPS chassis and fascia panel certified to UL94 V0
Shipping Dimensions (WxHxD) (mm) 1173 x 231 x 478
Panel Size Panel model PC1NWSMAN Heat Exchanger
Panel Net Weight (kg) 5.50 The heat exchanger shall be mechanically bonded fin to copper tube
Shipping Weight (kg) 7.20
Net Dimensions (WxHxD) (mm) Indoor Fan
1198 x 25 x 500
Indoor fan is a single crossflow type
Shipping Dimensions (WxHxD) (mm) 1262 x 122 x 566 Three fan speed settings and auto setting
Additional Accessories Drain Pump -
Drain Pump Max. Lifting Height/Displacement - Controls
Air Filter Removable / Washable The unit shall be operated via a wireless or wired remote control with
DDC type signal
The unit shall integrate with the Samsung NASA Controls Network
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
Solution
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM007NN1DCH/AZ Wind-Free 1Way Cassette Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM024NN1DCH/AZ Wind-Free 1Way Cassette Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM024NN1DCH/AZ
Features Type
Wind-Free 1Way Cassette

Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60


Capacity Cooling [kW]

Specifications
7.09
Cooling [Btu/h] 24,200
Heating [kW] 8.00
Heating [Btu/h] 27,300 • Compatible with Samsung DVM S, DVM S Water, and DVM Eco
Current Input (Nominal) Cooling 1 [A] 0.40 systems (AM**********/**).
Heating 2 [A] 0.40
• Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR fascia panel)
Power Input (Nominal) Cooling 1 [W] 80.00
Heating 2 [W] 80.00 • Built in condensate pump with maximum 75cm lift, check valve, and
Fan Type Crossflow Fan float switch that disables the indoor unit during overflow detection
Motor (Output) [W] 54 x 1
• Fascia panel shall have LED indicator lights and a motorized louver
Air Flow Rate (High / Mid / Low) [CFM] 600/547/494
Air Flow Rate (High / Mid / Low) [CMM] 17.00/15.50/14.00 • High-voltage terminal block temperature sensor to disable unit in the
Air Flow Rate (High/Mid/Low) [L/S] 283.33/258.33/233.33 event of power connection overheating.
External Static Pressure (Min / Std / Max) [in H20] -
External Static Pressure (Min / Std / Max) [mmAq] • Wind-Free™ function will close the supply air outlet louver while in
-
cooling mode to gently disperse cool air into the space without blowing
External Static Pressure (Min / Std / Max) [Pa] - directly onto occupants. The Wind-Free™ feature is optional and can be
Piping Connections Liquid Pipe (Φ, mm) 9.52 enabled using central or local control options (MWR-SH11N, MWR-
Liquid Pipe (Φ, inch) 3/8" WE13N, AR-EH03E only).
Gas Pipe (Φ, mm) 15.88
Gas Pipe (Φ, inch) • The Wind-Free™ 1-way cassette can be configured for 2-stage
5/8"
operation, cooling the space with the louver open (fixed or swing) until
Drain Pipe (Φ,mm) VP20 (OD 25,ID 20) the room temperature nears set temperature. Once room temperature
Field Wiring Power Source Wire 1.5 ~ 2.5 is near set temperature, Wind-Free™ operation will start automatically,
Transmission Cable 0.75 ~ 1.5 closing the louver and using the face of the fascia panel to gently cool
Refrigerant Type R410A the space with still air*.
Control Method EEV INCLUDED
• The Wind-Free™ panel (PC1NWFMAN) has an integral humidity
Sound Sound Pressure 42.0/39.0/36.0 sensor that will open the louvers for standard cool mode when space
Sound Power 60.0 conditions could potentially cause condensation formation on the
External Dimension (Indoor Unit) Net Weight(kg) 10.00 panel surface.
Shipping Weight (kg) 12.80
Net Dimensions (WxHxD) (mm) Construction
1200 x 138 x 450
Insulated, HIPS chassis and fascia panel certified to UL94 V0
Shipping Dimensions (WxHxD) (mm) 1435 x 224 x 525
Panel Size Panel model PC1NWSMAN Heat Exchanger
Panel Net Weight (kg) 5.50 The heat exchanger shall be mechanically bonded fin to copper tube
Shipping Weight (kg) 7.20
Net Dimensions (WxHxD) (mm) Indoor Fan
1198 x 25 x 500
Indoor fan is a single crossflow type
Shipping Dimensions (WxHxD) (mm) 1262 x 122 x 566 Three fan speed settings and auto setting
Additional Accessories Drain Pump -
Drain Pump Max. Lifting Height/Displacement - Controls
Air Filter Removable / Washable The unit shall be operated via a wireless or wired remote control with
DDC type signal
The unit shall integrate with the Samsung NASA Controls Network
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
Solution
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM024NN1DCH/AZ Wind-Free 1Way Cassette Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM012NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM012NNNDCH/AA
Features Type Wind-Free 4Way Cassette
(600x600)
Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60
Capacity Cooling [kW]

Specifications
3.52
Cooling [Btu/h] 12,000
Heating [kW] 3.96
Heating [Btu/h] 13,500 •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
Current Input (Nominal) Cooling 1 [A] 0.19 systems (AM**********/**).
Heating 2 [A] 0.19
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR fascia panel)
Power Input (Nominal) Cooling 1 [W] 28.00
Heating 2 [W] 28.00 •Built in condensate pump with maximum 29" lift from the bottom of
Fan Type Turbo Fan the unit, check valve, and float switch that disables indoor unit during
Motor (Output) [W] overflow detection
65 x 1
Air Flow Rate (High / Mid / Low) [CFM] 371/336/283 •Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CMM] 10.51/9.51/8.01
Air Flow Rate (High/Mid/Low) [L/S] 175.09/158.57/133.56 •Fascia panel shall have LED indicator lights and 4 motorized louvers
External Static Pressure (Min / Std / Max) [in H20] - with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [mmAq] -
•High-voltage terminal block temperature sensor to disable unit in the
External Static Pressure (Min / Std / Max) [Pa] - event overheating of power connection.
Piping Connections Liquid Pipe (Φ, mm) 6.35
Liquid Pipe (Φ, inch) 1/4" •Wind-Free™ function will close the supply air outlet louver while in
Gas Pipe (Φ, mm) 12.70 cooling mode to gently disperse cool air into the space without blowing
Gas Pipe (Φ, inch) directly onto occupants. The Wind-Free™ feature is optional and can be
1/2"
enabled using central or local control options (MWR-SH11N, MWR-
Drain Pipe (Φ,mm) VP25 (OD 32,ID 25) WE13N, MWR-WE13N, MWR-WG00*N, and AR-EH03U only).
Field Wiring Power Source Wire AWG 14
Transmission Cable 2 X 16 AWG SHIELDED •The Wind-Free™ 4-way cassette can be configured for 2-stage
Refrigerant Type R410A operation, cooling the space with the louver open (fixed or swing) until
Control Method the room temperature nears set temperature. Once room temperature
EEV INCLUDED
is near set temperature, Wind-Free™ operation will start automatically,
Sound Sound Pressure 34.0/30.0/26.0 closing the louver and using the face of the fascia panel to gently cool
Sound Power 51.0 the space with still air*.
External Dimension (Indoor Unit) Net Weight(kg) 12.00
Shipping Weight (kg) 14.00 •The Wind-Free™ panel (PC4NUFMUN) has an integral humidity sensor
Net Dimensions (WxHxD) (mm) that will open the louvers for standard cool mode when space
575 x 250 x 575
conditions could potentially cause condensation formation on the
Shipping Dimensions (WxHxD) (mm) 623 x 298 x 653 panel surface.
Panel Size Panel model PC4SUSMUN
Panel Net Weight (kg) 2.30 Construction
Shipping Weight (kg) 3.50 Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Net Dimensions (WxHxD) (mm) certified to UL94 V0.
620 x 45 x 620
Shipping Dimensions (WxHxD) (mm) 661 x 106 x 671 Heat Exchanger
Additional Accessories Drain Pump - The heat exchanger shall be mechanically bonded fin to copper tube
Drain Pump Max. Lifting Height/Displacement - Indoor Fan
Air Filter Removable / Washable Indoor fan is a single turbo type
Three fan speed settings and auto setting

* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
Controls
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.
The unit shall be operated via a wireless or wired remote control with

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM012NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
24/08/2023 1

Submittal AM024NN4DCH/AA Wind-Free 4Way Cassette Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM024NN4DCH/AA
Features Type
Wind-Free 4Way Cassette

Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60


Capacity Cooling [kW]

Specifications
7.03
Cooling [Btu/h] 24,000
Heating [kW] 7.91
Heating [Btu/h] 27,000 •Compatible with Samsung DVM S, DVM S Water, and DVM Eco
Current Input (Nominal) Cooling 1 [A] 0.30 systems (AM*********/**).
Heating 2 [A] 0.30
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR
fascia panel)
Power Input (Nominal) Cooling 1 [W] 40.00
Heating 2 [W] 40.00 •Built in condensate pump with maximum 29" lift, check valve, and
Fan Type Turbo Fan float switch that disables indoor unit during overflow detection
Motor (Output) [W] 65 x 1
•Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CFM] 618/565/494
Air Flow Rate (High / Mid / Low) [CMM] 17.50/16.00/13.99 •Fascia panel shall have LED indicator lights and 4 motorized louvers
Air Flow Rate (High/Mid/Low) [L/S] 291.65/266.64/233.13 with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [in H20] -
External Static Pressure (Min / Std / Max) [mmAq] - •High-voltage terminal block temperature sensor to disable unit in the
event overheating of power connection.
External Static Pressure (Min / Std / Max) [Pa] -
Piping Connections Liquid Pipe (Φ, mm) 9.52 Construction
Liquid Pipe (Φ, inch) 3/8" Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Gas Pipe (Φ, mm) 15.88 certified to UL94 V0.
Gas Pipe (Φ, inch) 5/8"
Drain Pipe (Φ,mm) Heat Exchanger
VP25 (OD 32,ID 25)
The heat exchanger shall be mechanically bonded fin to copper tube
Field Wiring Power Source Wire AWG 14
Transmission Cable 2 X 16 AWG SHIELDED Indoor Fan
Refrigerant Type R410A Indoor fan is a single turbo type
Control Method EEV INCLUDED
Sound Sound Pressure Three fan speed settings and auto setting
35.0/32.0/28.0
Sound Power 56.0
Controls
External Dimension (Indoor Unit) Net Weight(kg) 15.00 The unit shall be operated via a wireless or wired remote control with
Shipping Weight (kg) 18.50 DDC type signal
Net Dimensions (WxHxD) (mm) 840 x 204 x 840
Shipping Dimensions (WxHxD) (mm) 898 x 275 x 898
The unit shall integrate with the Samsung NASA Controls Network
Solution
Panel Size Panel model PC4NUSKUN
Panel Net Weight (kg) 5.80 Controls shall integrate with a BMS system
Shipping Weight (kg) 8.40
Net Dimensions (WxHxD) (mm) 950 x 45 x 950 Control wiring shall be 2 X 16 AWG shielded wire
Shipping Dimensions (WxHxD) (mm) 1005 x 100 x 1005
Additional Accessories Drain Pump -
Drain Pump Max. Lifting Height/Displacement -
Air Filter Removable / Washable

* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
24/08/2023 2

Submittal AM024NN4DCH/AA Wind-Free 4Way Cassette Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal AM048NN4DCH/AA Wind-Free 4Way Cassette Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM048NN4DCH/AA
Features Type
Wind-Free 4Way Cassette

Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60


Capacity Cooling [kW]

Specifications
14.07
Cooling [Btu/h] 48,000
Heating [kW] 15.83
Heating [Btu/h] 54,000 •Compatible with Samsung DVM S, DVM S Water, and DVM Eco
Current Input (Nominal) Cooling 1 [A] 0.75 systems (AM*********/**).
Heating 2 [A] 0.75
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR fascia panel)
Power Input (Nominal) Cooling 1 [W] 95.00
Heating 2 [W] 95.00 •Built in condensate pump with maximum 29" lift, check valve, and
Fan Type Turbo Fan float switch that disables indoor unit during overflow detection
Motor (Output) [W] 97 x 1
•Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CFM] 1024/954/848
Air Flow Rate (High / Mid / Low) [CMM] 29.00/27.01/24.01 •Fascia panel shall have LED indicator lights and 4 motorized louvers
Air Flow Rate (High/Mid/Low) [L/S] 483.26/450.22/400.20 with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [in H20] -
External Static Pressure (Min / Std / Max) [mmAq] •High-voltage terminal block temperature sensor to disable unit in the
-
event overheating of power connection.
External Static Pressure (Min / Std / Max) [Pa] -
Piping Connections Liquid Pipe (Φ, mm) 9.52 Construction
Liquid Pipe (Φ, inch) 3/8" Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Gas Pipe (Φ, mm) 15.88 certified to UL94 V0.
Gas Pipe (Φ, inch) 5/8"
Heat Exchanger
Drain Pipe (Φ,mm) VP25 (OD 32,ID 25) The heat exchanger shall be mechanically bonded fin to copper tube
Field Wiring Power Source Wire AWG 14
Transmission Cable 2 X 16 AWG SHIELDED Indoor Fan
Refrigerant Type R410A Indoor fan is a single turbo type
Control Method EEV INCLUDED
Three fan speed settings and auto setting
Sound Sound Pressure 45.0/42.0/39.0
Sound Power 60.0 Controls
External Dimension (Indoor Unit) Net Weight(kg) 18.50 The unit shall be operated via a wireless or wired remote control with
Shipping Weight (kg) 22.50 DDC type signal
Net Dimensions (WxHxD) (mm) 840 x 288 x 840
The unit shall integrate with the Samsung NASA Controls Network
Shipping Dimensions (WxHxD) (mm) 898 x 357 x 898 Solution
Panel Size Panel model PC4NUSKUN
Panel Net Weight (kg) 5.80 Controls shall integrate with a BMS system
Shipping Weight (kg) 8.40
Net Dimensions (WxHxD) (mm) Control wiring shall be 2 X 16 AWG shielded wire
950 x 45 x 950
Shipping Dimensions (WxHxD) (mm) 1005 x 100 x 1005
Additional Accessories Drain Pump -
Drain Pump Max. Lifting Height/Displacement -
Air Filter Removable / Washable

* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB.
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal AM048NN4DCH/AA Wind-Free 4Way Cassette Latin America

Specifications

English 2
Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
24/08/2023 1

Submittal MCM-A300N Touch centralized controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MCM-A300N
Features Type Touch centralized controller

Features
• 7" touch LCD controller
• Maximum 128 indoor units and Samsung ERV's
• Allows creation of zones for indoor unit grouping (12 maximum) with customizable zone icons
• Can connect and control up to 16 X DVM S systems (see page 2 for more details)
• 2 X digital input terminals for dry-contact connection to disable/enable all connected equipment (3 optional configuration
settings)
• 1 X digital output terminal for system operation status output, 12 VDC, 10 mA max. (short: 1 or more indoor units are ON.
Open: all indoor units are OFF)

Specifications
• SD card slot for data backup and future software updates
Specifications
Convenience Compatible with DVM S systems (AM****X****/**), DVM Chiller
• Scheduling (maximum 10 schedules) (AG0*******/**), CAC 1:1 systems (AC0********/**) without
• All ON/OFF button additional hardware/adapters. Compatible with the following systems
• Indoor unit operation mode, set temperature, fan speed, controller use/restriction enable/disable, louver control, and filter using MIM-N01 communication interface module: FJM multi-zone
reminder reset setting/checking. systems (AJ0*****CH/**), DVM Plus III and earlier VRF models.
• Cooling and heating temperature (desired temperature) limit setting Compatible with Fresh Access™ ERV units (AN***NSEDAV/**) using
• Group/zone control MXD-K200VN ERV kit at every ERV and 1 X MIM-N10 ERV interface
• Operation mode restriction setting module per 16 ERV Kits. Compatible with FCU Kit (MIM-F00N) using one
• Screen lock MIM-F10N FCU kit interface module per 16 FCU Kits.
• Restrict: ON/OFF, mode, set temperature, fan speed, advanced settings, and remote control use (basic indoor unit settings) Maximum:
for daily users • 64 indoor units, 1 system, and 16 MCU's when connected to F1/F2
• Menu lock (restrict indoor unit control, schedule setting/changing, and controller settings for daily users) (system/set layer)
• LCD ON/OFF button/indicator on front of controller to turn display ON/OFF (blue indicator: 1 or more indoor units are ON. • 128 indoor units and 16 systems when connected to R1/R2 (control
Red indicator: indoor unit/system error is present) layer)
• Option to group multiple indoor units to display as one indoor unit on user interface 100 - 240 VAC, 50/60Hz
RS485 communication
Can connect to R1/R2 or F1/F2 communication wires
Up to 16 X MCM-A300N controllers can connect together on R1/R2 or
F1/F2 communication line
Up to 15 X MCM-A300N controllers can connect together on R1/R2
communication line when used with MIM-D00AN, MIMD01AUN, MIM-
B17N, MIM-N17BN, MIM-B18N, and MIM-B18BN gateways
16 AWG X 2 shielded wire for all R1/R2 and F1/F2 communication wiring

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
24/08/2023 2

Submittal MCM-A300N Touch centralized controller Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
24/08/2023 1

Submittal MWR-SH11N Wired remote controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MWR-SH11N
Features Type Wired remote controller

Features
• Internal temperature sensor

• Backlight

• Built-in infrared receiver to allow control of indoor unit wirelessly with AR-EH03U or AR-KH03U wireless controllers

• Indoor unit operation ON/OFF, operation mode, set temperature, louver position (cassette, ceiling, wall units), and fan speed
settings

Specifications
• Error display Specifications
• Compatible with Samsung DVM S Systems (AM****X****/**,
• Filter replacement alarm display and reset AM0***XMDCH/**) and CAC systems (AC0***X**CH/**) only.
• Can connect and control up to 16 indoor units on a single system or
• Single indoor unit control or multiple unit control (maximum 16 units) across multiple systems (group control)
• 2 Conductor connection
• All button lock (option) • DC 12V power supplied by indoor unit
• PLC (power line communication) is done on F3/F4 terminals.
• Partial controller button lock (ON/OFF, temperature setting, fan speed, timer function, louver swing, sleep function, quiet • MWR-SH11N has screw terminals for all wiring connections, wire is not
function, outing function, and operation mode buttons) included
• 16 AWG X 2 shielded cable is necessary for proper operation
• Upper and lower temperature setting restriction • Maximum wire length: 328' from MWR-SH11N to farthest indoor unit.

• Heat, cool, dry, fan, and auto mode skip options (skips specified mode on wired controller)

• Restrict wireless controller signal (optional)

• Single event timer function (ON/OFF control, 30 minutes - 24 hours timer setting options)

• System/indoor unit function and operation indication (defrost, error, restricted controller, central control, and SPi status)

• Service mode for connected indoor unit operation monitoring, addressing, and setup

• Can be used to specify "Mode Master" while connected to a single indoor unit when used with heat pump systems to control
system mode (heating or cooling)

• Outing function to keep a minimum heating (61~72°F) and cooling (77~86°F) temperature while you are away. When Outing
mode is activated, the unit will operate at the specified Outing temperature.
If indoor temperature is 9°F difference from desired Outing temperature, the indoor unit will turn on. If indoor temperature is
the same as desired Outing temperature, the indoor unit will turn off automatically. This is repeated depending on indoor
temperature for 12 hours. After 12 hours, Outing mode is released /canceled.

• Wind-FreeTM Control (applies to supported models when using


the Wind-FreeTM fascia panel)

• Long Reach Function (applies to supported models when using


the Wind-FreeTM fascia panel)

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
24/08/2023 2

Submittal MWR-SH11N Wired remote controller Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal MXJ-TA3419M Outdoor joint Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MXJ-TA3419M
Features Type Outdoor joint

• Required component for Samsung DVM S Series systems with multiple ODU modules on piped as a single system
• Quantity of 1 necessary for 2 module systems (2 outdoor units piped together)
• Quantity of 2 necessary for 3 module systems (3 outdoor units piped together),
• Includes both liquid and suction fittings, insulation, and ties to secure insulation
• Heat recovery systems require additional fitting (MXJ-TA3100M, MXJ-TA3800M)
• Included insulation shall be polystyrene certified to UL94 V0, 5/8" wall thickness
• Constructed of brazed copper or brazed copper and brass
• Must be installed horizontally level MW
• Each model shall have the capability of field modification (with tubing cutter) to connect various pipe sizes and/or include

Specifications
adjustable reducers

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal MXJ-TA3419M Outdoor joint Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 1

Submittal MXJ-YA3419M Y-joint Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MXJ-YA3419M
Features Type Y-joint

• Required component for Samsung DVM S and DVM Eco systems (AM****X****/**) with multiple evaporators and/or Mode
Change Units (MCU)
• Constructed of brazed copper or brass and copper
• Indoor unit Y-joint models include both liquid and suction fittings, insulation, and ties to secure insulation
• Heat recovery (HR) Y-joint models are required for branching the hot gas pipe throughout heat recovery systems (HR
systems only)
• Included insulation shall be polystyrene certified to UL94 V0, 5/8" wall thickness
• Inlet pipe shall be adjustable to facilitate different pipe sizes without having to braze additional fittings MW
• Each model shall include adjustable reducers as noted in the table below

Specifications

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
31/07/2023 2

Submittal MXJ-YA3419M Y-joint Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.