introduction
C N L C / 2 0 2 2 . 9
Content
Transmitter
Flow direction
水流方向
68S
Neutron
source
Inelastic gamma rays
O16
n 10-610-3 S Receiver
f ( t ) tdt
Elastic gamma rays v Ls Tm Tm Ta / 2
f ( t ) dt
10-3Sseveral days
g
Oxygen activation gamma rays Q Tm Pc
n
Transmitter Time spectrum Hitting neutron area
O16
Amplitude
Background area
static activation area
Dynamic activation area
N16
Time
The free high energy neutrons knock the oxygen nuclei and creates a radioactive nigrogen-16 The flow of oxygen-containing substances, especially water, is reflected by measuring
nuclei. This subsequently undergoes beta decay leaving an exited state of oxygen. The exited the gamma ray time spectrum in the tubing, annular space and outside casing. The
oxygen then stabilizes generally by emitting gamma rays. The oxygen activation detects the velocity of water flow can be calculated by analyzing the time spectrum, and then the
gamma rays counts. flow rate can be calculated
Content
CCL
GR+CCL Temperature, Pressure When activated the upper neutron source, the
GR
downward water flow is measured.
Temperature
U4-2226mm
Pressure
U3-1542mm
When activated the lower neutron source, the
Neutron source U2-612mm upward water flow is measured
D4
U1-353mm
D3
D2 Neutron source
D1
D1-374mm
Both upward and downward water flow are measured
D2-998mm
Neutron source when logging one time
D3-1732mm
D4-2629mm
D5-3513mm
TEMP, PRE
GR+CCL
Time spectrum
Time spectrum
GR
D4
Temp
U3
Pressure
U2
Neutron source
U1
D4
D3
D3 Neutron
D2 source
D2
D1
D1 D1
D2
D3
Time(s)
Neutron source
Time(s)
D4
D5
One Transmitter-Receiver oxygen activation spectrum peak One Transmitter-two Receivers oxygen activation spectrum peak
Tools Introduction
Specifications
Parameter OD(mm) Temperature(℃) Pressure(MPa) Precision Resolution Range
CCL — — -
Temperature ±1 ℃ 0.1 ℃ -20-135 ℃
Pressure 43 135 80 ± 0.2MPa 1psi 0-80MPa
GR 7% 0.1CPS/API 0-500API
Flow velocity 0.6-25m/min
CCL — — -
Temperature ±0.5 ℃ 0.1 ℃ -20-135 ℃
Pressure 38 135 80 ± 0.5MPa 1psi 0-80MPa
GR 7% 0.1CPS/API 0-500API
RPM-OA Mode
Investigation Tool-fluid relative Logging speed(depend
Mode OD(mm) Temperature(℃) Pressure(MPa)
depth velocity on the fluid velocity
Hydrolog 43 177 103.4 152-254mm 5-15fpm 3ft/min-200ft/min
Advantages and Disadvantages
Advantages:
a. Suitable for all types of injection Wells
b. More accurately calculate the absorption water profile
c. Monitor the channel and loss interval, check downhole tube.
d. Measure the annular space flow through tubing
e. Monitor flow leakage location, sealing condition
f. It is not affected by the injection liquid, channel and oil pollution in the tubing
g. Not use any radioactive tracer and not cause contamination to the wellbore and formation
Disadvantages:
a. The string ID is required highly
b. The measurement accuracy is affected when the flow rate is too low
Content
Total injection
Separation injection
Time (S)
Time spectrum
Upward flow
Time spectrum
Time (S)
Downward flow
Time (S)
Application
• Casing leakage
The well is a general positive injection well, injection rate is 115m3/d. After
500 m
release isotope two times, The absorption water profile was not detected in the
650 m
perforation zone under tube shose and the tracer reaction was not detected too.
Water
distributor
Upward flow
outside casing
Time (S)
Time spectrum
Upward flow
outside tube
Time (S)
Time spectrum
No water flow
perforation
Time (S)
Thanks