NeuMR Rena
01/02
NeuMR Rena
RF Acquisition
Stronger real-time
performance
Fiber Gradient Gradient
Distributed Higher SNR waveform
generator amplifier
Spectrometer
Wider scalability
The realization of digital transmissionthrough optical fiber ensures both high bandwidth and
fidelity of gradient output.
Gradient
Broader openness
Advanced gradient system
The gradient system utilizes an embedded cooling design and real-time temperature control at multiple points to ensure
more accurate temperature control and achieve accurate output of gradient waveforms.
46 mT/m
03/04
NeuMR Rena
GP
SS-DWI MUSIC GR
Imaging echo Navigator echo
IAC Joint
DWI b0 DWI b1000 DWI b5000 DWI b10000
The higher b value, the higher performance requirements for the equipment. MUSIC sequence provides high
spatial resolution and clear anatomical details.
05/06
NeuMR Rena
TR TE
f(x) =o B1 - sin( B1+ 0 )
1-exp(- ) i( (∆B) TE+ o)
T1
TR
e T2* e
1-cos(B1 0 ) exp(-
+
T1
)
...... a1 a2 Echo1
rf
ADC
The dual-domain fidelity module ensures the authenticity of the data during the image
reconstruction process as well as the stability of the reconstructed image.
Routine image
Taking brain scanning as an example,
compared to conventional scanning techniques, SWI
Angiography
PDWI T1WI T2*WI eT1WI
Quantitative image
tSWI
07/08
NeuMR Rena
A single BH scanning can achieve ultra fast multi-phase dynamic enhancement scanning, which can continuously Precise Quantification of Hepatic Fat & Analysis of Iron Deposition.
obtain arterial multi-subphase images, ensuring ultra-high temporal and spatial resolution.
√ Spatial resolution:
266.0mm2
平均值:25.88801 平均值:27.17098
最大值:29.27922 最大值:29.52341
最小值:21.04978 最小值:19.82879
均方差:1.88353 均方差:1.89779
0.7mm*0.7mm*2.5mm
DANCE adopts K-space dynamic random sparse sampling, K-space central area fully sampled repeatedly, and
dynamic random sparse sampling of surrounding data.
面积:279.3mm2 面积:
141.3mm2
平均值:28.81576 平均值:89.54499
最大值:31.57467 最大值:94.33329
最小值:25.37206 最小值:83.00255
均方差:1.45672 均方差:3.28900
09/10
NeuMR Rena
A noninvasive method to evaluate the biochemical changes of cartilage and meniscus in patients with early-stage
osteoarthritis.
More convenient More professional
T1 Map T2 Map
11/12
NeuMR Rena
Comprehensive Application
Nerves and Blood vessels Joint
13/14
NeuMR Rena
Comprehensive Application
Abdomen Deep R
15/16
Comprehensive Application Service and Logistics Support
SWI
Neusoft Global Service & Logistics Network
Tanzania
TI 2000ms TI 2500ms