Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

Motorway Project (M6) Communication Network System

Material Approval Request

Document History
Revision Date Description of Changes Author
(dd-mm-yyyy)

A 18-01-2022 First issue Yanisa D.

Submission No. M06 COM 20005 A Confidential and Proprietary Page 2 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

Table of Contents
1 LIST OF MATERIALS .......................................................................................................................... 6

2 MATERIAL COMPLIANCE TABLE ..................................................................................................... 7

APPENDIX A – TECHNICAL SPECIFICATION OF COMMUNICATION NETWORK SYSTEM .............. 10

Submission No. M06 COM 20005 A Confidential and Proprietary Page 3 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

List of Tables
TABLE 1: LIST OF COMMUNICATION NETWORK SYSTEM EQUIPMENT .................................................................. 6
TABLE 2: COMPLIANCE TABLE OF COMMUNICATION NETWORK SYSTEM ............................................................. 7

Submission No. M06 COM 20005 A Confidential and Proprietary Page 4 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

List of Figures
N/A

Submission No. M06 COM 20005 A Confidential and Proprietary Page 5 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

1 List of Materials
Table 1: List of Communication Network System Equipment
Item Material / Equipment Product Name Brand Model Reference
Appendix A – Optical Fiber Cable
1 Optical Fiber Cable Single Mode Optical Fiber Cable FUTONG ADSS(SJ)
(FUTONG ADSS(SJ))

Submission No. M06 COM 20005 A Confidential and Proprietary Page 6 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

2 Material Compliance Table


Table 2: Compliance Table of Communication Network System
No. DOH’s Requirements Proposed Material Compliance Reference
Request for Proposal
Volume 4 DOH’s Requirement
Part 2 Outline Technical Specification
SECTION G: COMMUNCATION NETWORK
SYSTEM
5. BACKBONE NETWORK
5.2.4 Optical Fiber Cable (OFC) Installation:
a) Installation of backbone communication The proposed Optical Fiber Cable is able to use Fully Comply Appendix A – Optical Fiber Cable
cables shall be either aerial cable installation for both aerial cable installation and duct cable (FUTONG ADSS(SJ)) Page 2
or buried cable in duct bank, except the installation.
following cases where only buried cable in
duct bank shall be deployed.
1) Installation of backbone communication Proposed as mentioned. Fully Comply -
cables at the grade-separated
interchange areas
2) Installation of backbone communication Proposed as mentioned. Fully Comply -
cables at toll plaza areas
3) Installation of backbone communication Proposed as mentioned. Fully Comply -
cables crossing travelled ways
b) OFC shall be outdoor fiber cables, used for The proposed OFC is outdoor cables and able to Comply with Appendix A – Optical Fiber Cable
aerial or duct applications. Figure-Eight loop use for aerial or duct applications. All Dielectric better (FUTONG ADSS(SJ)) Page 2
cables (self-supporting cables) shall be used Self Support (ADSS) cables are proposed instead proposal
for aerial OFC installation. of Figure-Eight cables because there is no metal
inside the cable so it is more suitable to be
installed on an electric pole with HV electric
cables installed. Another benefit is no cable joints
are needed when changing from aerial installation
to duct installation or vice versa.

Submission No. M06 COM 20005 A Confidential and Proprietary Page 7 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

No. DOH’s Requirements Proposed Material Compliance Reference


c) OFC installation shall be physically secured Proposed as mentioned. Fully Comply -
throughout the network to enable the reliable
provision and high performance of backbone
communication network.
d) Optical Fiber Cable (SM G.652D or The proposed material is single mode Optical Fully Comply Appendix A – Optical Fiber Cable
equivalent) with at least 24-core fibers shall Fiber Cable type ITU-T G.652D with 24-core (FUTONG ADSS(SJ)) Page 3 and
be utilized as connectivity media. fibers. Page 4

e) The Private Party shall coordinate with Proposed as mentioned. Fully Comply -
DOH’s other contracting parties to agree on
fixation and/ or anchor bolt drilling to suspend
cable conduit or containment on elevated
structures and associated structural
components.
f) The Private Party shall be responsible for Proposed as mentioned. Fully Comply -
provision and installation of additional duct
banks or handholes, where appropriate, for
cabling works of Communication Network
System. Should the Private Party decide to
use any of the duct banks and handholes
provided by DOH’s other contracting parties,
it shall do so at its own risk. Any required
modification to existing duct banks/handholes
provided by DOH’s other contracting parties
shall be under the Private Party’s
responsibility.
g) Indelible labelling, marking and Proposed as mentioned. Fully Comply -
documentation for any OFC installation shall
be implemented.
h) Pathway, conduit for OFC installation in Proposed as mentioned. Fully Comply -
addition to duct bank system shall be under
the Private party’s responsibility.
i) OFC of network lines among Toll Control Proposed as mentioned. Fully Comply -
Buildings shall be designed and installed as
redundant with separate installation path.
OFC for Backbone Network shall be
separated from access and roadside
network.

Submission No. M06 COM 20005 A Confidential and Proprietary Page 8 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

No. DOH’s Requirements Proposed Material Compliance Reference


j) OFC of network lines connecting among Toll Proposed as mentioned. Fully Comply -
Control Buildings shall be deployed as
backbone network only. Branch joints or
terminations of OFC of network lines among
Toll Control Buildings and the CCB of M6
shall not be permitted.

Submission No. M06 COM 20005 A Confidential and Proprietary Page 9 of 10


Motorway Project (M6) Communication Network System
Material Approval Request

Appendix A – Technical Specification


of Communication Network System

Submission No. M06 COM 20005 A Confidential and Proprietary Page 10 of 10


Optical Fiber Cable
(FUTONG ADSS(SJ))
(6 Pages)
SINGLE MODE
OPTICAL FIBER CABLE SPECIFICATION
ADSS(SJ)

No. FT-S22104
Version: A
Issued: Nov. 08, 2022

(ITU-T Rec. G.652D)

Futong Group Communication Technology (Thailand) Co., Ltd.

All Right Reserved

Add: No.7/324, Moo 6, T.Mabyangporn A.Pluakdaeng, Rayong 21140 Thailand


Tel.: +66 (0) 38 027 412; Fax: +66 (0) 38 027 411
www.futonggroup.com.cn

2022 ©Copyright. Specifications subject to change without notice.

Appendix A – Optical Fiber Cable Page 1


Product: ADSS(SJ)
Spec. No. FT-S22104A
Issued: Nov. 08, 2022

1. General
1.1 The specification covers the construction and properties of optical fiber cable.
5.2.4 a), 5.2.4 b)
1.2 The cable could be used for aerial or duct installed with span length 40meters.
1.3 The optical fiber which is used in the cable is also in compliance with ITU-T Rec. G.652D.
1.4 The cable generally meets any latest relevant ITU-T Recommendation or better.
1.5 The fiber shall operate in 1310nm and 1550nm.
1.6 The cable could serve for 25 years without any significant deterioration.
. Cross Section of Cable

(ADSS SJ- 12 G.652D)

Appendix A – Optical Fiber Cable Page 2


Product: ADSS(SJ)
Spec. No. FT-S22104A
Issued: Nov. 08, 2022

3. Optical Fiber in the Cable


3.1 Construction 5.2.4 d)
Fiber Type Single mode type ITU-T G.652D
Material Ge doped fused silica
Mode field diameter 1310nm 9.2±0.4μm
1550nm 10.4±0.8μm
Core concentricity error ≤ 0.6μm
Cladding diameter 125±1μm
Cladding non-circularity ≤ 1.0%
Coating Material UV curable acrylic
Diameter 250±15μm(Colored)
3.2 Optical characteristics
Attenuation 1310nm ≤ 0.36 dB/km
1550nm ≤ 0.22 dB/km
Zero-dispersion Wavelength 1300~1324nm
Zero-dispersion slope ≤0.092ps/(nm2.km )
Chromatic Dispersion Coefficient 1310nm ≤ 3.5(ps/nm.km)
1550nm ≤ 18.0(ps/nm.km)
Cable Cut-off Wavelength (λcc) ≤ 1260nm
Polarization Mode Dispersion(PMD) ≤ 0.2ps/km1/2
Fiber proof-tested 0.69GPa ( 1.0%, 100kpsi)

Appendix A – Optical Fiber Cable Page 3


Product: ADSS(SJ)
Spec. No. FT-S22104A
Issued: Nov. 08, 2022

Optical Cable
4.1 Construction
Cable Type ADSS(SJ)
5.2.4 d)
Number of Fibers 12,24
Fiber Construction Consult 3.1
Central Strength
Material FRP
Member
Water Blocking Water Blocking Tape and
Material
Member Water Blocking Yarn
Material PBT
Loose Tube
Filling Compound Fiber Jelly
Filler Rod Material Polypropylene (PP)
Additional
Material Aramid Yarn
Strength Member
Rip Cord No. 1
Material UV-Proof HDPE(Black)
Outer Sheath
Thickness Min. 1.5mm

4.2 Buffer Tube Stranding, cable size and weight

Number of Cable Diameter Approx. Weight


Fiber count Fiber per tube
Tube/Filler (±0.3mm) (kg/km)
12 6 2/3 9.3 65
24 6 4/1 9.3 65

4.3 Identification
Color Code for fiber and loose tube.
No. 1 2 3 4 5 6
Color Blue Orange Green Brown Grey White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua

Appendix A – Optical Fiber Cable Page 4


Product: ADSS(SJ)
Spec. No. FT-S22104A
Issued: Nov. 08, 2022

5. Optical Fiber Cable Characteristics

Item Test Condition Specification at 1550nm


IEC 60794-1-2-E1
(after test)
Tensile Mandrel diameter: ≥30 x cable diameter
Attenuation change ≤0.1 dB
Loading Load : 1,800N
No fiber break and no sheath damage
Hold time: 10 minutes
IEC 60794-1-2-E3
Attenuation change ≤0.1 dB
Crush Load : 1,000N/100mm
No fiber break and no cable damage
Loading time: 5 minutes
IEC 60794-1-2-E4
Impact energy: 5 N.m Attenuation change ≤0.1 dB
Impact
Radius of hammer head:12.5mm No fiber break and no cable damage
No. of impacts : 3 points (1 time/point)
IEC 60794-1-2-E6
Mandrel radius: 20 x cable diameter
Repeat Attenuation change ≤0.1 dB
Load: 50N
Bending No fiber break and no cable damage
Bending angle : ±90
No. of cycles : 25
IEC 60794-1-2-E7
Length : 1 m Attenuation change ≤0.1 dB
Torsion/Twist
Twist angle : ±180 No fiber break and no cable damage
No. of cycles : 5 cycles
IEC 60794-1-2-F1
Temperature Temperature: -10 to +70℃ Attenuation change ≤0.1 dB/km
Cycling No. of cycles : 1 No fiber break and no cable damage
Soak time: 12 hours
IEC-794-1-2-E14
Sample length: 30 cm
Drip test No filling compound drip
Temp: 65 ±5°C
Time: 24 h
IEC 60794-1-2-F5
Water Head of water : 1 m
No water leakage at end of cable
Penetration Test time : 24 hours
Sample length: 3 m

※ When laying in the duct environment, the optical cable application should be consistent
with the above performance

Appendix A – Optical Fiber Cable Page 5


Product: ADSS(SJ)
Spec. No. FT-S22104A
Issued: Nov. 08, 2022

6. Cable sheath Marking


➢ Marking Color:White
➢ Interval:1m
➢ Contents(for example):

FUTONG ADSS SJ **F G.652D 20** ****M


Explain:
FUTONG : The name of manufacturer.
ADSS SJ: The name of cable.
**F : Fiber counts
G.652D: the type of fiber,
20**: The year of manufacture
****M :Length marking ,starting number is 0000M

※The sheath marking can be changed with customer’s requirement.

Packing and shipping


7.1 Cable Drum: wooded drum ;
Standard reel length:4000m/reel(or according to customer’s requirement. )
7.2 Labeling
The direction of rotation of the color scheme is shown by making the clockwise and anti-
clockwise ends with red and green adhesive tape respectively
The markings are on both sides of the flanges as follows(for example):
➢ FUTONG
➢ Cable type/Size
➢ Cable length
➢ Cable Weight
➢ Shipping mark
※Can be changed with customer’s requirement.

----------END OF SPECIFICATION ----------

Appendix A – Optical Fiber Cable Page 6