Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Annual Production Report produced by Đorđe Zarić

Design 1 s13, 45.23185080579747, 19.816029570161255


 Report  System Metrics  Project Location

Project Name s13 Design Design 1

Project Module DC
45.23185080579747, 19.816029570161255 5.16 kW
Address Nameplate

Đorđe Zarić Inverter AC 5.00 kW


Prepared By
inzenjer.telefon.inzenjering@gmail.com Nameplate Load Ratio: 1.03

Annual
6.038 MWh
Production

Performance
81.1%
Ratio

kWh/kWp 1,170.2

TMY, 10km Grid, meteonorm


Weather Dataset
(meteonorm)

3a0a9ab623-6a4c79415d-cf752ae5b6-
Simulator Version
1a381515ec

 Monthly Production  Sources of System Loss

1000
AC System:
System: 0.5% Shading: 0.0%
Shading:

Inverters: 3.0%
Inverters: Reflection: 3.6%
Reflection:
750
Clipping: 0.0%
Clipping:
Wiring: 0.2%
Wiring:
kWh

Soiling: 2.0%
Soiling:
500
Mismatch: 3.1%
Mismatch:

Irradiance: 0.9%
Irradiance:
250

0
Temperature: 7.3%
Temperature:
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

GHI POA Shaded Nameplate Grid


Month
(kWh/m2) (kWh/m2) (kWh/m2) (kWh) (kWh)
January 36.3 48.3 48.3 232.7 213.6
February 53.7 65.9 65.9 319.9 291.5
March 100.4 115.9 115.9 566.1 502.1
April 134.6 142.7 142.7 696.9 605.2
May 178.6 182.4 182.4 894.1 752.0
June 182.9 183.6 183.6 899.3 751.0
July 200.7 203.7 203.7 997.3 827.5
August 165.8 173.8 173.8 851.2 706.6
September 114.4 126.9 126.9 619.8 529.7
October 80.3 98.0 98.0 476.3 418.4
November 46.7 62.1 62.1 299.9 270.3
December 28.9 38.8 38.8 186.8 170.2

© 2024 Aurora Solar 1/3 April 03, 2024


Annual Production Report produced by Đorđe Zarić

 Annual Production  Condition Set


Description Output % Delta Description Condition Set 1
Annual Global Horizontal Irradiance 1,323.4 Weather Dataset TMY, 10km Grid, meteonorm (meteonorm)
POA Irradiance 1,442.3 9.0%
Solar Angle Location Meteo Lat/Lng
Irradiance Shaded Irradiance 1,442.2 0.0%
(kWh/m2) Transposition Model Perez Model
Irradiance after Reflection 1,390.3 -3.6%
Irradiance after Soiling 1,362.5 -2.0% Temperature Model Sandia Model
Total Collector Irradiance 1,362.5 0.0% Rack Type a b Temperature Delta
Nameplate 7,040.2 Fixed Tilt -3.56 -0.075 3°C
Output at Irradiance Levels 6,979.2 -0.9% Temperature Model
Parameters Flush Mount -2.81 -0.0455 0°C
Output at Cell Temperature Derate 6,470.0 -7.3% East-West -3.56 -0.075 3°C
Energy Output After Mismatch 6,266.9 -3.1% Carport -3.56 -0.075 3°C
(kWh) Optimal DC Output 6,256.3 -0.2%
J F M A M J J A S O N D
Constrained DC Output 6,256.3 0.0% Soiling (%)
2 2 2 2 2 2 2 2 2 2 2 2
Inverter Output 6,068.6 -3.0%
Irradiation Variance 5%
Energy to Grid 6,038.2 -0.5%
Temperature Metrics Cell Temperature
4° C
Spread
Avg. Operating Ambient Temp 15.1 °C
Module Binning Range -2.5% to 2.5%
Avg. Operating Cell Temp 31.0 °C
Simulation Metrics AC System Derate 0.50%

Operating Hours 4593 Uploaded


Module Characterization
Module By
Solved Hours 4593
Characterizations LX-430M/182-108+ GG Spec Sheet
HelioScope
1500V (Luxor) Characterization, PAN
Component Device Uploaded By Characterization
Characterizations Symo 5.0-3-M (Fronius) HelioScope Spec Sheet Efficiency

 Components  Wiring Zones

Component Name Count Description Combiner Poles String Size Stringing Strategy
1 (5.00 Wiring Zone - 6-23 Along Racking
Inverters Symo 5.0-3-M (Fronius)
kW)
Luxor, LX-430M/182-108+ GG 12 (5.16
Module  Field Segments
1500V (430W) kW)
Intrarow Frame
Description Racking Orientation Tilt Azimuth Frames Modules Power
Spacing Size
Field Segment Flush Portrait 5.16
20° 227.2181° 0.0 m 1x1 12 12
1 Mount (Vertical) kW

© 2024 Aurora Solar 2/3 April 03, 2024


Annual Production Report produced by Đorđe Zarić

 Detailed Layout

© 2024 Aurora Solar 3/3 April 03, 2024

You might also like