1. THIS DRAWING IS A COPYRIGHT, CONTRACTORS MUST CHECK ALL DIMENSIONS ON SITE. ONLY FIGURED DIMENSIONS ARE
TO BE WORKED FROM . DISCREPANCIES MUST BE REPORTED IMMEDIATELY TO ARCHITECT BEFORE PROCEEDING.
3349 1358
20526
1357
GA
RISA
N SE
MPA 1360
DA
N 1356
PROPOSED SITE
GARISAN
11
6°40
ANJAKAN BANGUNAN 10' '00
" 63
.167
SEMPADA
3348
AN
JA
KA
N
N BA
NG
UN 007
006
007
AN
008
009
0010
008
001
002 WAKAF 20 TLM ' 009
003
2
004
WAKAF
005
CALDESAC
INTERL RL :
OCKING
BLOCK
119
001
UP
350°53'00
ANJAKAN
002
003
TANDAS & WUDUK
TLK
119
(L)
RL :
004
"
BANGUN
76.142
005
WAKAF
6.1m(w)
PREMIX
006
1
AN 20'
way
IX
w) way
PREM
6.1m(
MASJID U
PELAN KUNCI
RL : 119
3. ALL GROUND BEAMS TO BE LAID WITH 1 LAYER SIRIM APPROVED DAMP PROOF COURSE (DPC) WITH BITUMINOUS ADHENSIVE JOINT,OVERLAID ABOVE
PREM
w) way
4. ALL GROUND FLOOR AND WET FLOOR AREAS MUST BE CONSTRUCTED AND COMPLETED WITH APPROVED WATERPROOFING MEMBRANCE AND
MUST BE LAID UP TO A MINIMUM 300MM HIGH RESPECTIVELY. METHOD STATEMENT, STANDARD BROCHURE OR CATALOGE MUST BE
ANJAKAN
171°18'20
BILIK MANDI
341°3
5. BRICKWALLS TO BE REINFORCED WITH RC STIFFENER LINTOL AT EVERY MAX. 3M x 3M AND TIED TO MAIN STRUCTURE AT EVERY 1200MM INTERVALS AND
TLM
012
PROVIDED WITH EX-MAT TO COINCIDE WITH TIES. LINTOLS SHALL BE PROVIDED TO ALL DOOR AND WINDOW OPENINGS ACCORDING TO ENGINEER
1'00"
013
014 SPECIFICATION.
BANGUN
"
015
6. ALL DOOR AND WINDOW FRAMES SHALL BE OF FIRST CLASS 'RESAK' OR EQUIVALENT HARDWOOD FREE FROM ALL DEFECTS OR APPROVED STEEL FRAMES;
184.652
TO BE COATED WITH 3 COATS OF APPROVED PAINT AND COMPLETED WITH MIN. 75MM WIDE DECORATIVE TIMBER ARCHITRAVE ALL AROUND ON BOTHSIDES.
6.498
WAKAF
4 7. ALL PLUMBING WORKS AND SANITARY INSTALLATION TO BE CARRIED OUT BY A VALID LOCAL LICENCED PLUMBER/ CONTACTOR,
TANDAS & WUDUK APPLICABLE TO EACH DISTRICT/STATES.
PREM
010
6.1m(
(P)
AN 20'
8. ALL WIRING WORKS SHALL BE IN METAL CONDUIT GI OR / AND CONCEALED AND CONFORM TO CURRENT I.E.E REGULATIONS AND BOMBA REQUIREMENT,
IX
w) way
INTERL
OCKING
BLOCK 011 MUST BE CARRIED OUT BY A VALID LOCAL LICENCED ELECTRIAN.
UP
9. ALL TELEPHONE TRUNKING FOR SHOPHOUSE OR ANY COMMERCIAL BUILDING SHALL BE INSTALED BY A REGISTERED CONTRACTOR OF LOCAL TELECOM
012 DEPARTMENT AND CONFORM TO THE CURRENT RULES AND REGULATIONS OF THE DEPARTMENT/ SERVICE PROVIDERS.
10.FIRE RATED PARTITION WALLS SHALL BE CONTINUOUS, FREE FROM HOLES AND COMPLY WITH BOMBA REQUIRMENT. PLASTERING SHALL BEAPPLIED INSIDE
1168 CEILING SPACE AND NO CRISS-CROSSING TIMBER OR STRUCTURAL MEMBERS THROUGH THE FIRE-RATED WALL.
11.ALL FIRE-RATED DOORS MUST BE COMPLETED WITH AUTO-CLOSER AND OTHER ACCESSORIES APPROVED BY BOMBA.
342°1
MINAREK
12.ALL BOMBA ITEMS INSTALLED SUCH AS 'KELUAR' SIGNAGES, EMERGENCY LIGHTS, FIRE RATED DOORS, FIRE ALARMS, ELECTRICAL CONDUITS AND FIRE
RATED BRICKWORKS (CEMENT SAND) MUST BE APPROVED BY BOMBA AND SUPPORTED BY DOCUMENTS 'BLANKETCERTIFICATE' FORM C1, C2, &
5'00"
016 RESPECTIVELY TO COVER MINIMUM AREAS OF ALL GROUND FLOOR AREAS INCLUSIVE OF ALL APRONS, PORCHES, TERRACES, YARDS PLUS MIN. AREA
017 OF 1500MM WIDE SURROUNDING THE BUILDINGS. THE WORK MUST BE CERTIFIEDTO COVER MINIMUM PERIOD OF WARRANTY OF 2 YEARS FROM
018 THE LAST TREATED AREA.
4
TLM
14.ELECTRICAL WIRING INSTALLATION FOR SEMI-DS,BUNGALOWS, COMMERCIAL BUILDINGS, OFFICES SHALL BE IN 3 PHASE WIRING INCLUSIVE METERING,
019
SWITCHES, FUSE BOX ETC. IN COMPLIANCE WITH TNB APPROVAL WHICH SHALL BE APPLIED THROUGH CONTRACTOR'S LICENCED ELECTRICIAN.
020
021
022 15.FLOOR FINISHES SUCH AS TILING/CARPET/TIMBER STRIP/ MARBLE / GRANITE OR OTHER FINISHES SHALL BE COMPLETED WITH MIN. 100MM HG.
023 DECORATIVE PERIMETER SKIRTING OF THE SAME MATERIALS OR TIMBER / STEEL AND THE PATTERN TO BE APPROVEDBY THE ARCHITECT.
16.ALL SEWERAGE WORKS SYSTEM MUST BE CARRIED OUT BY IWK/JPP/SPAN LICENSED PLUMBER/ CONTRACTOR AND TO COMPLY/ SUBMIT THE
REQUIREMENT FORM DUELY SIGNED DURING AND ON COMPLETION OF THE WORKS.
17.ANY R.C ROOF / "FLAT" ROOF CONSTRUCTION MUST HAVE MIN. 3° SLOPE TO NEAREST PERIMETER SCUPPER DRAIN AND COMPLETED WITH
SMOOTH RENDER FINISHES.
3350 BANGUNAN 18.CONTRACTOR TO SUBMIT FORMS TO THE ARCHITECT, G1-G21 OR EQUAVALENT DUELY SIGNED AT VARIOUS STAGES OF CONSTRUCTION TO THE
3347 SOKONGAN PROPOSED SITE RELEVANT CONSULTANTS FOR VERIFICATION AND CERTIFICATION UNDER THE CERTIFICATE OF COMPLETION AND COMPLIANCE (CCC) REQUIREMENT.
6.1m(w)
PREMIX
19.FOR RENOVATION WORK, ALL DIMENSIONS ARE INDICATIVE AND SUBJECTED TO EXISTING CONDITION. COMPLETION OF WORKS MUST BE BASED ON ACTUAL
DIMENSION AT NO ADDITIONAL COST.
way
20.THE CONTRACTOR TOGETHER WITH THE LICENCED PLUMBER SHALL CARRY OUT DISINFECTION TEST OF THE COMPLETED PLUMBING WORK UNDER
6.1m(w)
PREMIX
SECTION 32(2) KAEDAH-KAEDAH INDUSTRI PERKHIDMATAN AIR (RETIKULASI AIR DAN PEMASANGAN PAIP) 2014 AND ISSUED THE TEST REPORT
TO THE CONSULTANT TOGHETHER WITH FORM G5/D5(CCC) DUELY SIGNED .
way
1170 21. ANY ALUMINIUM INSULATION / RADIANT BARRIER WITH SISALATION NETTING SPECIFIED IN THE DRAWING SHALL COMPLY WITH MS 2095
( FIRE RETARDANT ) UNDER THE FOURTH SCHEDULE CIDB ACT 1994-520.
22.ANY MATERIAL SPECIFIED SHALL BE OF MEDIUM GRADE QUALITY OR HIGHER TO ARCHITECT / SO APPROVAL.
RL : 119
23. ALL FIRE COMPARTMENT WALL SHALL BE CONSTRUCTED UP TO SOFFIT ROOF COVERING AND COMPLETE WITH R.C SLAB OR ROOF.
RL : 119
PINDAAN
INTERLOCKIN
PREMIX
ON
PYL
AN
PAD 8.7m(w)
way
SEM
PROJEK :
014
1. MASJID
TLK
025
042 017
034
2. BANGUNAN SOKONGAN
114.384
026
TLK
018
043 U
6.1m(w)
PREMIX
035
3. MINAREK
PELAN LOKASI
027
way
044
036 Q
GARISAN
PREMIX
045
028
6.1m(w)
way
PREMIX
SKALA 1 : NTS
ANJAKAN
020
037
way
029
SEMPADA
RL : 119
046
DI ATAS SEBAHAGIAN LOT 3346,
021
038
030
047 022
BANGUN
039
031
N
RL : 119
048
049
040
ON
PYL
: 7 + 1 = 8 Petak
AN
SEM
PAD
TLK PELAWAT + OKU "Saya sebagai pemilik mengakujanji untuk mematuhi segala syarat pelan lulus Pihak Berkuasa
WAKAF JUMLAH YANG DIPERLUKAN : 42 Petak dan akan bertanggungjawab penuh sewajarnya sekiranya syarat tersebut tidak dipatuhi."
BANGUNAN
GARISAN
WAKAF 5
WAKAF 6
WAKAF
8
7 F TLK AWAM : 42 Petak
TLK KAKITANGAN MASJID : 6 Petak
SEMPADA
20'
LOT 3346
2.419 Ek i. TEMPAT LETAK MOTOSIKAL : 320mp / 15mp : 21 Petak
0.9789Ha
JUMLAH YANG DIPERLUKAN = 21 TLM
JUMLAH YANG DISEDIAKAN = 23 TLM ARKITEK NORMAN SELAMAT
AN 60' NO. 428,LORONG TITIWANGSA 2
BANGUN
ANJAKAN TAMAN BUKTI SETIA , AMPANGAN
70400 SEREMBAN
PENGIRAAN ANGGARAN PENJANAAN NEGERI SEMBILAN DARUL KHUSUS
SISA PEPEJAL (PPSPPA) ARKITEK NORMAN SELAMAT TEL: 606-6793532 FAX: 606-6785062
E-MAIL: archns@gmail.com
KATEGORI BANGUNAN : MASJID
FREKUENSI KUTIPAN : SETIAP HARI ARKITEK :
KUANTITI SISA BAKI SEHARI : 0.15m3 /
RL : 119
1171
1169 NEGERI SEMBILAN KIRAAN KAWASAN LAPANG / HIJAU /LANSKAP DILUKIS OLEH : LUQ TARIKH :AUG 2023 DICETAK: 10.08.2023
KAWASAN LAPANG : 0,000mp DISEMAK OLEH : ANS SKALA : 1:500
KAWASAN CERUN : 0,000mp
1175 1173 1167 M/S:
1273 NO. LUKISAN : 01
12