Item 1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Date:

DATA SHEET Nº:


Three Phase Induction Motor - Wound Rotor Dimensional Drawing

Customer:
Customer reference:
Line:
Identification
Frame: 560B Insulation class: F
Output: 750 kW Temperature rise: class B at SF 1.00
Frequency: 50 Hz Temperature rise: class F at SF 1.15
Poles: 10 Locked rotor time: Not applicable
Rated speed: 591 rpm Duty: S1
Slip: 1.5 % Ambient temperature: 40 °C
Rated voltage: 6600 V Connection:Y Altitude: 1000 m
Rated current: 86.51 A Protection Degree: IP55
Rotor voltage: 1410 V Connection:Y Cooling: IC611
Rotor current: 316.3 A Mounting: B3R
Locked rotor current: Not applicable Vibration: A 2.8 mm/s rms
LRC (p.u.): Not applicable Moment of inertia: 187.3 kgm²
kVA/kW: Not applicable Noise level: 85 dB(A), tol: 3 dB(A)
No load current: 38.67 A Direction of rotation: COUNTERCLOCKWISE
Rated torque: 12119 Nm (Facing the motor drive end shaft)
Locked rotor torque: Not applicable Starting method: RHEOSTAT
Breakdown torque: 250 % Coupling: DIRECT

Performance Data Load Data


Output 50% 75% 100% Load type: CRUSHER
Resistant torque: 11938 Nm
Efficiency(%) 94.2 94.7 94.8
J(J=GD²/4): 3 x Jmotor
cos ø 0.62 0.73 0.8
Notes/Accessories
- FINAL COLOUR RAL- 5009
- Rotor Voltage Tolerance: +/- : 10 % - CT SELF BALANCING: 5VA, 10P20, 50:5A, 0,6KV.
- Load data not supplied. Considered Jload = 3 x - BRUSHES DEVICE - RAISABLE, 400V, 50Hz
Jmotor. -CUSTOMER : ZEST ELECTRIC MOTORS PTY LTD
- STRAY LOAD LOSSES 0.50% OF INPUT POWER.
- HEATING CONSTANT: 106 MIN TEMPERATURE DETECTOR - PT100 - 2 PER PHASE( 3 WIRES)
- COOLING CONSTANT: 535 MIN TEMPERATURE DETECTOR - PT100 - 1 PER BEARING( 3 WIRES)
- TORQUE AND CURRENT VS SPEED CURVE AT CM-14403/2014 SPACE HEATER - 220V 500W
- THERMAL LIMIT CURVE AT CM-14404/2014 PAINTING PLAN - 212P/ RAL 5009
- PERFORMANCE VS OUTPUT CURVE AT CM-14405/2014
- MINIMUM AMBIENT TEMPERATURE = -20 °C
- SPACE HEATER : 110/220V - 500W
- TEMPERATURE DETECTOR : 2 PER PHASE 3 WIRES
- TEMPERATURE DETECTOR : 1 PER BEARING 3 WIRES
- SHAFT GROUNDING BRUSH IN THE FRONT BEARING
- NDE BEARING INSULATED
- PAINTING PLAN 212P
Standards
Specification: IEC 60034-1
Test: IEC 60034-2
Noise: IEC 60034-9
Vibration: IEC 60034-14
Tolerance: IEC 60034-1
Edition
Performed Checked Date Site

Changes Performed Checked Date


8
7
6