UT INSPECTION REPORT

CLIENT LOCATION INSPECTION DATE


ALGOA MALEMBO 18 October 2023
OCEANEERING JOB NO. REPORT NO.
CABGOC 171092 UT-PCP SANHA-P23-1072956-002-1023-1
CLIENT ORDER NO.
PAGE 1 OF 4
1564567
EQUIPMENT DETAILS: SURFACE CONDITION
PLATFORM SANHA PCP As Welded & Clean
DESCRIPTION SANHA NORTH WIND PROJECT - WPK-002 MATERIAL
DRAWING No. P23-1072956-002 Sht 1 Carbon Steel
REQUEST No. 428 NOMINAL THICKNESS
WO #: 1072956 AFE #: 1200313182 See Below
RELATIVE SENSITIVITY LEVEL(s), TRANSFER CORRECTION VALUE & CORRECTION FACTOR (IF APPLICABLE)
0°- 1st BWE to 75% FSH + 6dB 70° - DAC + TC + Scanning Level
45° - DAC + TC + Scanning Level
60° - DAC + TC + Scanning Level
PROCEDURE / WORK INSTRUCTION / TECHNIQUE ACCEPTANCE CRITERIA
NDT-OPR-126 Rev 6 AWS D1.1
NDT-TEC-U118 Rev 3 2020 Edition
EQUIPMENT MAKE & MODEL SERIAL NO.
OLYMPUS EPOCH 6LT 220079902
OLYMPUS EPOCH 6LT 220049902
PROBE TYPE(S) & SERIAL NUMBER(S)
WK 0° 2.5MHz 10mmØ Twin SN15945 B&W 60° 2MHz 10mmØ Single SN03710 BW 70° 2MHz 10mmØ Single SN03824
WK 45° 2MHz 10mmØ Single SN15221 WK 70° 2MHz 10mmØ Single SN15638 B&W 60° 2MHz 10mmØ Single SN03749
WK 45° 2MHz 10mmØ Single SN15228 WK 70° 4MHz 10mmØ Single SN20136
COUPLANT TEST BLOCK(S) TYPE & SERIAL NO(S) CALIBRATED RANGE(S)
Wall paper paste IIW V2 Block-76746 Various to suit
V1 Block-43512 & A5 Block-13/50/92
SURFACES FROM WHICH SCANNING TOOK PLACE: Branch Members
RESTRICTIONS TO REQUIRED SCANNING: None
WELD NO WELDER ID DIMENSIONS DRAWING NUMBER RESULT
SW9 DK 8"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW11 DK 8"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW13 DR 8"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW15 BH 8"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW17 DL 8"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW19 DL 8"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW31 DK 14"Ø X 0.65" THK P23-1072956-002 Sht 1 ACCEPTED
SW34 DK 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW35 DK 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW36 DR 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW39 DR 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW38 DL 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW45 DL 14"Ø X 0.65" THK P23-1072956-002 Sht 1 ACCEPTED
SW47 DL 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED
SW48 BH 10"Ø X 0.5" THK P23-1072956-002 Sht 1 ACCEPTED

COMMENTS: N/A

OCEANEERING INSPECTOR OCEANEERING SUPERVISOR CLIENT

SIGN
Sirajudeen
Hameed
Digitally signed by Sirajudeen
Hameed
Date: 2023.10.21 15:39:35 +01'00'
SIGN Vernon Digitally signed by
Vernon Kistnasamy
SIGN
Sherwi Digitally signed
by Sherwin Vere
QUALS. PCN LEVEL II
NAME Sirajudeen H / Salesh M
DATE
NAME
Kistnasamy Date: 2023.10.21
15:39:43 +01'00'
DATE
NAME
n Vere Date: 2023.10.22
06:41:21 +01'00'

This report signifies acceptance or otherwise with regard only to the acceptance criteria of the applicable standard. Such compliance, or otherwise, does
not infer or imply suitability and/or fitness for any particular use or purpose. No other communication by Oceaneering, whether oral or written, shall be
construed as an option as to whether the weld or other work inspected should be accepted or rejected.
NDT REQUEST
Platform Name: PCP SANHA Job Description NORTH WIND PROJECT WPK-002
NDT Contractor Oceaneering Request No. 428
AFE / CC No. 1200313182 Work Order No. 1072956 Date: 15-Oct-23
Specification and Acceptance Criteria: AWS D 1.1
Pipe/Plate Types of NDT
Welder'
Dwg No./Line No.: Joint No. Dia/Size Thickness Process
ID RT UT MPI DPI HT
(in.)

P23-1072956-002 SW9 DK 8" .5" SMAW √ √


SW11 DK 8" .5" SMAW √ √
SW13 DR 8" .5" SMAW √ √
SW15 BH 8" .5" SMAW √ √
SW17 DL 8" .5" SMAW √ √
SW19 DL 8" .5" SMAW √ √
SW31 DK 14" .65" SMAW √ √
SW34 DK 10" .5" SMAW √ √
SW35 DK 10" .5" SMAW √ √
SW38 DR 10" .5" SMAW √ √
SW39 DR 10" .5" SMAW √ √
SW38 DL 10" .5" SMAW √ √
SW45 DL 14" .65" SMAW √ √
SW47 DL 10" .5" SMAW √ √
SW48 BH 10" .5" SMAW √ √

Requested by: ACFS QAQC Received by:


Name: Anoop K Name:
Date: 15-Oct-23 Date: Form ACA-C014-WI-F1, Rev. 0, 06-2023

You might also like