Address at which the examination was made: 116 CARNALBANAGH ROAD BROUGHSHANE BALLYMENA BT42 4NT
3. Location Yard
8. Results
(a) Defects which require corrective action The lower bracket on the offside carriage ram is cracked at the welds and should be
before further use or before a specified restored to manufacturers specification before further use.
date
On-site report issued No. 330219-030
(b) Defects requiring corrective action as The driver's seat is damaged and should be repaired or renewed.
soon as reasonably practicable A weld between the offside of the carriage and the boom head is cracked and should be
restored to manufacturers specification.
Thr rear worklight is not operating and should be restored to working order.
10. Latest date by which the next thorough examination should be carried out 20/12/2019
Image
I declare that the above equipment has been thoroughly examined on 20/06/2019 and, provided that you remedy any defects stated above,