❖ INTRODUCTION
Solar water heating (SWH) is heating water by sunlight, using a solar thermal collector. A
variety of configurations is available at varying cost to provide solutions in different climates
and latitudes. SWHs are widely used for residential and some industrial applications.
A sun-facing collector heats a working fluid that passes into a storage system for later use.
SWH are active (pumped) and passive (convection-driven). They use water only, or both
water and a working fluid. They are heated directly or via light-concentrating mirrors. They
operate independently or as hybrids with electric or gas heaters. In large-scale installations,
mirrors may concentrate sunlight into a smaller collector.
A conventional water heater is tank that heats the water stored in it, using a burner located at
the bottom; because of its efficiency, it does not need a power motor. The hot water you use
for washing, bathing, and cooking comes from the water stored in the tank.
❖ ABSTRACT
Home heating and production of domestic hot water are important items of expenditure and
energy consumption. These are also sources of pollution and emission of greenhouse gases.
This work presents a comparative study between conventional and solar heating of an
individual house in Algerian climate conditions. For this purpose, we performed a general
heat balance on various heat losses in house parts. Needs for heating and domestic hot water
were also estimated. Based on these needs, sizing of the solar system has been developed. To
compare the performances of solar and classic systems, we conducted an economic
evaluation and determined the environmental impact. Although conventional energy is
heavily subsidized in Algeria, the comparison of the cost of solar thermal kWh with other
energies and the large quantities of CO2 avoided clearly show that economic and
environmental benefits are in favor of solar heating development.
➢ Solar Water Heater Project
Solar water heating (SWH) is heating water by sunlight, using a solar thermal collector. A
variety of configurations is available at varying cost to provide solutions in different climates
and latitudes. SWHs are widely used for residential and some industrial applications.
A sun-facing collector heats a working fluid that passes into a storage system for later use.
SWH are active (pumped) and passive (convection-driven). They use water only, or both
water and a working fluid. They are heated directly or via light-concentrating mirrors. They
operate independently or as hybrids with electric or gas heaters. In large-scale installations,
mirrors may concentrate sunlight into a smaller collector.
Simple designs include a simple glass-topped insulated box with a flat solar absorber made of
sheet metal, attached to copper heat exchanger pipes and dark-colored, or a set of metal tubes
surrounded by an evacuated (near vacuum) glass cylinder. In industrial cases a parabolic
mirror can concentrate sunlight on the tube. Heat is stored in a hot water storage tank. The
volume of this tank needs to be larger with solar heating systems to compensate for bad
weather and because the optimum final temperature for the solar collector is lower than a
typical immersion or combustion heater. The heat transfer fluid (HTF) for the absorber may
be water, but more commonly (at least in active systems) is a separate loop of fluid
containing anti-freeze and a corrosion inhibitor delivers heat to the tank through a heat
exchanger (commonly a coil of copper heat exchanger tubing within the tank). Copper is an
important component in solar thermal heating and cooling systems because of its high heat
conductivity, atmospheric and water corrosion resistance, sealing and joining by soldering
and mechanical strength. Copper is used both in receivers and primary circuits (pipes and
heat exchangers for water tanks).
Residential solar thermal installations fall into two groups: passive (sometimes called
"compact") and active (sometimes called "pumped") systems. Both typically include an
auxiliary energy source (electric heating element or connection to a gas or fuel oil central
heating system) that is activated when the water in the tank falls below a minimum
temperature setting, ensuring that hot water is always available. The combination of solar
water heating and back-up heat from a wood stove chimney can enable a hot water system to
work all year round in cooler climates, without the supplemental heat requirement of a solar
water heating system being met with fossil fuels or electricity.
When a solar water heating and hot-water central heating system are used together, solar heat
will either be concentrated in a pre-heating tank that feeds into the tank heated by the central
heating, or the solar heat exchanger will replace the lower heating element and the upper
element will remain to provide for supplemental heat. However, the primary need for central
heating is at night and in winter when solar gain is lower. Therefore, solar water heating for
washing and bathing is often a better application than central heating because supply and
demand are better matched. In many climates, a solar hot water system can provide up to
85% of domestic hot water energy. This can include domestic non-electric concentrating
solar thermal systems. In many northern European countries, combined hot water and space
heating systems (solar combisystems) are used to provide 15 to 25% of home heating energy.
When combined with storage, large scale solar heating can provide 50-97% of annual heat
consumption for district heating.
➢ Conventional Water Heater Project
Conventional storage water heaters remain the most popular type of water heating system for
the home. Here you'll find basic information about how storage water heaters work; what
criteria to use when selecting the right model; and some installation, maintenance, and safety
tips.
A single-family storage water heater offers a ready reservoir -- from 20 to 80 gallons -- of hot
water. It operates by releasing hot water from the top of the tank when you turn on the hot
water tap. To replace that hot water, cold water enters the bottom of the tank through the dip
tube where it is heated, ensuring that the tank is always full.
Conventional storage water heater fuel sources include natural gas, propane, fuel oil, and
electricity. Learn more about fuel types available when selecting a new water heater.
Since water is heated in the tank until the thermostat setpoint temperature is reached, energy
can be wasted even when a hot water tap isn't running due to standby heat losses, which
result from the tank losing heat to the surrounding environment. Only tankless water heaters -
- such as demand-type water heaters and tankless coil water heaters -- avoid standby heat
losses. Some storage water heater models have heavily insulated tank, which significantly
reduce standby heat losses and lower annual operating costs. Look for models with tanks that
have a thermal resistance (R-Value) of R-24 and above to avoid adding an insulation blanket
(electric water heaters only).
Gas and oil water heaters also have venting-related energy losses. Two types of water heaters
-- a fan-assisted gas water heater and an atmospheric sealed-combustion water heater --
reduce these losses. Visit the Energy Basics site to learn more about how conventional
storage water heaters work.
For low energy bills the best choice to consider are heat pump water heaters and solar water
heaters. These water heaters are usually more expensive but they have significantly lower
annual operating costs that result in short payback periods.
Selecting a Storage Water Heater
The lowest-priced storage water heater may be the most expensive to operate and maintain
over its lifetime. While an oversized unit may be alluring, it carries a higher purchase price
and increased energy costs due to higher standby energy losses.
Proper installation and maintenance of your water heater can optimize its energy efficiency.
Proper installation depends on many factors. These factors include fuel type, climate, local
building code requirements, and safety issues, especially concerning the combustion of gas-
and oil-fired water heaters. Therefore, it's best to have a qualified plumbing and heating
contractor install your storage water heater. Be sure to do the following when selecting a
contractor:
If you're determined to install it yourself, first consult the water heater's manufacturer.
Manufacturers usually have the necessary installation and instruction manuals. Also, contact
your city or town for information about obtaining a permit, if necessary, and about local
water heater building codes.
Periodic water heater maintenance can significantly extend your water heater's life and
minimize loss of efficiency. Read your owner's manual for specific maintenance
recommendations.
Routine maintenance for storage water heaters, depending on what type/model you have, may
include:
• Flushing a quart of water from the storage tank every three months
• Checking the temperature and pressure valve every six months
• Inspecting the anode rod every three to four years.
After your water heater is properly installed and maintained, try some additional energy-
saving steps to help lower your water heating bills. Some energy-saving devices and systems
are more cost-effective to install with the water heater.
➢ Comparative Study
For calculating thermal losses and energy needs, we used climate data from the region
for the winter period (November-March): External temperature 2 °C with 80% humidity,
soil temperature 7 °C. The comfort temperature is set at 20° C, humidity 40%. The used
Thermal resistances of surface exchange 1/h due to the heat exchange by radiation and
convection are from the Algerian regulations (table 1) [5].
The outer walls are made of a double wall separated by an air gap of 10 cm thick (Fig.
1a). The inner wall is built from bricks 10 cm thick coated with cement and final layer of
gypsum on both sides (Fig. 1b). Table 2 summarizes the thermal characteristics of the
various components of the exterior walls.
a
Fig. 1. (a) External double wall (2 et 3 : Walls in bricks ; 1 et 6 :
cement coating, 4 : air space; 5 : Gypsum coating) (b)
Internal wall (1 : Gypsum coating ; 2 : Bricks ; 3 : Cement
coating)
N° Component Thickness e (m) ߣ (W/m °C) ሺ• ʹιȀሻ
1 et 6 Cement coating 0.01 1.4 0.007
2 et 3 Brick 0.1 0.2 0.5
4 Air gap 0.1 0.16 0.625
5 Gypsum 0.01 0.35 0.028
Tabl 2. Thermal conductivity and resistance of the components of exterior walls [5]
For external walls, the thermal resistance amounted to R = 1.83 m 2 °C/ W and the
transmission coefficient to K = 0.544 W/m2 ° C. Similarly, the result for the inner
walls is R = 0.79 m2 °C/ W and K = 1.266 W/m2 °C.
As illustrated in Figure 2, the roof consists of a solid slab made of reinforced concrete
and various coating layers and thermal insulation. The floor consists of a solid concrete
slab covered with gravel sand and tile flooring. Thermal parameters of the roof and floor
are summarized in Table 3.
Fig. 2. Scheme of roof's components (1
multilayer sealing, 2 concrete, 3 cork, 4
concrete slab, 5 cement coating, 6 plaster)
From these data, it follows that the resistance of the roof amounts to 1.42 m2 °C/W and
K rises 0.704 W/m2 °C. For the floor, we get R=0,283 m2 °C/W and K= 3.533 W/m2 °C
Table 3. Conductivity and thermal resistance of the components of roof and low
floor [5]
Thickness E
Component (m) ߣ (W/m°C) ሺ• ʹιȀሻ
1 Multilayer sealing 0.02 0.45
2 Concrete in the 0.07 1.75 0.044
Roof shape of slope 0.04 0.045 0.04
3 Thermal insulation
cork 0.888
4 Concrete slab 0.20 0.73
0.273
5 Cement coating 0.01 1.4
0.007
6 Plaster 0.01 0.35
0.028
Concrete solid slab 0,12 1.75
0.068
Floor Gravel sand 0.03 1.2
0.025
Floor tiles 0.02 1 0.02
wood 2
Doors internal glass 5
external 3.5
Windows 4.347
Heat losses are calculated by stationary regime. Heat gains due to the inertia of the
walls and furnishings as well as the contribution of the occupants are not taken into
account. Knowing the surface S and its transmission coefficient K determined
previously, we can calculate the thermal losses Q according to Q= K.S.ǻT with ǻT=
Tinternal - T external= 18 °C
3.2.1. Thermal losses by transmission through the external walls
The results of loss through transmission across exterior walls so calculated are
summarized for each room of the house in table 5.
The 5 glass panes have a total area of 8.81 m2. With K = 4.35 W/m°C and ǻT = 18°C, one
obtains a heat losses of
689. 82 W. Losses through doors are summarized in table 6.
The roof occupies a total area of 42.04 m2. The transmission coefficient is K = 0.704
W/m2 °C. As a result, heat losses by transmission through the roof totaled 532.75 W.
Thermal bridges Qtb is generally determined by multiplying the total external losses by a
factor taken equal to
0.1. With Q total, ext= Qwall ext+ Q windows +Q roof . So calculated, the heat Losses by thermal
bridges amounted to Qthb = 210.12 W
We consider for the soil a temperature gap ǻT= 7 °C. All parts have a surface 40.04
m2 .
Considering R= 0.283 m2 °C/W (table 1and 3), we obtain the heat losses through the
floor Q= 990.23 W
3.2.6. Loss through internal walls with unheated space
With an area of 13.16 m2, a transmission coefficient K = 1.266 W/m° C and ǻT= 6°C,
the hall leads to a heat loss of 99.95 W.
By ǻT=18 °C, we calculate as a function of habitable volume the Q R losses due to air
renewal. The achieved results are summarized in table 7.
For the considered house, all the heat losses by surfacic and lineic transmission are
summarized in table 8. The so achieved total losses amounted to 4581.40 W.
The distribution of losses per component of the house (figure 3), shows that almost half
of losses occur at windows / doors and floor. The isulation lack leads to relatively high
transmission losses. In contrast, in the roof, the thermal insulation by cork and other layers
greatly reduces losses
The energy required for heating during the winter (period extending from November to
March) for a comfort temperature Tc = 20°C is determined using Qh = 0.024. (QT/ǻT).
Ndj with ǻT = 18 °C and Ndj= degree days.
Records of monthly average temperatures for the winter of 2001 to 2010 are given by the
local weather station in Tizi-Ouzou. They are summarized with degree days in table 9.
Table 9. Records average temperature and degree days for the heating season
Month Nov Dec Jan Feb Mar
Heating temperature 20 20 20 20 20
Tc (°C)
Daily temperature 14.52 11.76 9.16 10.97 13.66
Tmj(°C)
¨T= Tc - Tmj 5.48 8.24 10.84 9.03 6.34
Degree days (Ndj) 164.4 255.44 336.04 252.84 196.54
Total degree days
1205,26
Finally, the energy required for heating is Qh = 7362.36 KWh. This energy is largely
sufficient to cover the thermal loss of the house and the various losses in the ducts of the
heating system.
According to the Department of water management of Tizi-Ouzou, the need for hot
water is estimated to 25 l / day per occupant at 50 ° C.
Energy requirements for the production of sanitary hot water are given by Becs =
N.V. (Tec - Tef ). ȡ . Cp N number of occupants, V = volume of water used per
person per day.
So calculated, the thermal hot water needs are in the order of 109.9 KWh per month.
The thermal hot water needs for the winter are Becs = 549.3 KWh. This is equivalent to
energy of 9.1 KWh/m2.year. In European countries where hot water is used in large
quantities during the whole year, the rate is at least 25 KWh/m2.year.
The total energy (space heating + hot water) to provide for seasonal winter rises to
Etotal = 7911.66 KWh. In this energy supply, the share of the hot water does not exceed
7%. This low rate is due to the fact that the daily hot water available for each occupant
volume is very low (25 L), water is not available abundantly in Algeria.
2) Economic study
The economic study will allow us to compare the studied solar system with those
using conventional energy. Investment in renewable energy is no exception to the rule of
financial profitability. Even if solar heating is environmentally friendly, available and
sustainable [6], the economic side is certainly important in households, hence all interest
to evaluate the price of solar kWh and compare it to traditional energy available in the
market, namely natural gas, electricity, fuel and butane gas.
The calculation includes the investment in acquiring the solar collectors and the
storage tank. Sizing of the solar installation using the Transol software leads to 9 plan
solar collectors (total area = 18.9 m2) and one storage tank of 1500 L.
Cost of al solar collectors = 80 000 DA (1 Algerian Dinar
DA = 0.11 Euro) Cost of storage tank 1500 L = 120 000
DA
The total cost of the solar system would be 840 000 DA.
Thus, for a lifetime of the installation which is on average 25 years, and the energy
requirements given above, the price of solar kWh would rise 4.25 DA.
Currently, the state provides financial assistance of 45% on investment. Taking into
account this grant, the price of solar kWh actually rises to only 2.34 DA which
corresponds to around 0,023 Euro
Conventional energies used in Algeria are electricity, natural gas, butane / propane
gas and diesel. The prices of energy sold locally are fixed by the State. Those are heavily
subsidized prices which are well below the real cost price of production. The cost per
kWh of natural gas and electricity depends on the amount of energy consumed in a given
period. In general, two price ranges are applied.
The total energy consumption for heating and hot water is 1582.33 kWh / month (see
paragraph 3.3.2), equivalent to 1364.08 thermies / month
Table10. illustrates the cost per unit of consumption and the amount to pay for the
monthly consumption. Prices shown are those currently applied by the national company
of electricity distribution and gas [7].
The price per kWh using natural gas for water heating and the house amounts to 0.277
DA
Table11 shows the unit cost of electricity and the amount to pay for monthly
consumption.
Table 11. Unit cost of electricity per consumption tranche and the amount to pay
for monthly consumption
1st level 2ndlevel Amount(DA)
The price of a KWh using electricity for house heating and hot water is therefore 4.415 DA
which corresponds around 0.04 Euro.
Butane gas is sold on the market as a bottle containing 13 kg of butane; the price is
230 dinars per bottle. The energy content of 1 Kg of butane is in the range of 13.72
kWh. The energy needed for the house is 115.33 Kg corresponding to the contents of
about 9 bottles. From these data, it follows that the price of butane kWh is 1.31 DA.
The energy power of one liter of diesel is about 10.4 KWh. the price is currently set at
13.5 DA/l. The calculation gives for the KWh diesel a price of 1.30 DA.
We summarize in Table 11 the different costs of a KWh depending on the energy used.
Natural Gas
gas butane Diesel Electricity
Cost of KWh
(DA) 2.34 0.28 1.31 1.3 4.42
Cost of KWh
(in 2,3 0,28 1,3 1,3 4,4
Eurocents)
This comparison shows that the solar kWh subsidized costs only half the power. It
remains more expensive than gas and diesel. For consumers, the natural gas is the most
economical, but in the price shown below, we have not included the heavy investment
borne by the state for compressor stations for transportation and its connection to the
customer.. It is also for this reason that, despite all efforts by the state, natural gas is
currently reaches only half of the population.
Solar thermal systems allow the substitution of fossil fuels which are depletable and
polluting energies. Solar energy, on the other hand, is not only cost free and
inexhaustible, but it generates no pollution. Table 12 presents the CO2 unit emissions
from the combustion of different fossil fuels [8-10]. In the case of the use of electrical
energy, emissions are given according to its production pathway which are in Algeria
essentially gas turbines in combined cycle and simple cycle. For this energy source, we
record the primary energy which is equal to consumed electrical energy multiplied by
the conversion factor 2.58. The hydraulic and diesel sectors do not play an important
role.
Table 12. CO2 unit emissions produced by different energy sources [7-
9]
On the basis of these emission factors, we summarize in Table 13 the CO2 emissions
caused by the monthly consumed energy by the studied house.
Table 13. Amount of CO2 emitted by the house
These results clearly show the advantage of solar thermal energy compared to
conventional fuels. CO2 avoided monthly by the solar rises, depending on the type of
energy used, from 0.4 to 2 tons, equivalent to 2-10 tons per winter. To this, we should
add methane emissions which are not negligible when using gas and diesel fuel.