Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Blue rectangles are links to other catalog pages.

SOLENOID VALVES

SV10-40A Spool, 4-Way, 2-Position


DESCRIPTION
A solenoid-operated, four-way, two-position, direct-acting, spool-type, screw-in
hydraulic cartridge valve.

OPERATION
When de-energized, the SV10-40A allows flow from 3 to 2, as well as from 4 to 1.
When energized, the cartridge’s spool shifts to open 3 to 4, and 2 to 1. All ports are
closed at crossover.
NOTE: When used in a full loop mode, the SV10-40A delivers up to 37.9 lpm (10 gpm)
maximum flow. When used as a selector valve, the SV10-40A can handle up to
22.7 lpm (6 gpm) maximum flow rate.

FEATURES
• Optional coil voltages and terminations. • Efficient wet-armature construction.
• All ports may be fully pressurized. • Industry common cavity.
• Cartridges are voltage interchangeable.
• Hardened precision spool and cage for long life.
• Optional waterproof E-Coils rated up to IP69K.
• Continuous-duty rated solenoid with unitized, molded coil design.

RATINGS
SYMBOLS Operating Pressure: 207 bar (3000 psi)
Proof Pressure: 276 bar (4000 psi)
USASI/ISO: TRANSITION:
Burst Pressure: 621 bar (9000 psi)
Flow: 37.9 lpm (10 gpm) max when used in full loop mode; 22.7 lpm (6 gpm) when
used as a selector valve.
Internal Leakage: 164 cc/minute (10 cu. in./minute) max. at 207 bar (3000 psi);
Port 3 to port 1, de-energized, with ports 2 and 4 blocked.
Temperature: -40 to 100 °C (-40 to 212° F) with standard Buna N seals
-26 to 204 °C (-15 to 400 °F) with Fluorocarbon seals;
PERFORMANCE (Cartridge Only) -54 to 104 °C (-65 to 225 °F) with Polyurethane seals.
Coil Duty Rating: Continuous from 85% to 115% of nominal voltage
FULL LOOP PRESSURE DROP
3 to 2 De-Energized, 2 looped to 4 — - — - Initial Coil Current Draw at 20 °C: Standard Coil: 1.67 A at 12 Vdc; 0.18 A at 115 Vac
3 to 4 Energized, 4 looped to 2 ——— (full wave rectified).
4 to 1 De-Energized, 2 looped to 4 - - - - -
2 to 1 Energized, 4 looped to 2 – – – –
E-Coil: 1.7 A at 12 Vdc; 0.85 A at 24 Vdc
32 cSt/150 sus oil at 40°C Minimum Pull-in Voltage: 85% of nominal at 207 bar (3000 psi)
17.2/250
Filtration: See page 9.010.1
PRESSURE bar/psi

13.8/200
Fluids: Mineral-based or synthetics with lubricating properties at viscosities of
10.3/150
7.4 to 420 cSt (50 to 2000 sus); See Temperature and Oil Viscosity, page 9.060.1
Installation: No restrictions; See page 9.020.1
6.9/100
Cavity: VC10-4; See page 9.110.1
3.4/50 Cavity Tool: CT10-4XX; See page 8.600.1
Seal Kit: SK10-4X-MMM; See page 8.650.1
7.5 15.1 22.7 30.3 37.9
2 4 6 8 10 Coil Nut: without manual override: Part No. 7004400
FLOW lpm/gpm
OPERATING LIMITS
Pull-In Current 85% of Nominal
Drop-Out Current 5% of Nominal
OPERATING LIMITS
Valve used as a selector with inlet at port 3.
Pull-In Current 85% of Nominal
Independent load pressures
Drop-Out Current 5% of Nominal at ports 2 and 4, ports not looped.
Inlet at Port 1; Port 3 to Tank /// SV10-40AY: ////
Inlet at Port 3; Port 1 to Tank \\\ SV10-40A and SV10-40AM: \\\\
32 cSt/150 sus oil at 40°C
207 32 cSt/150 sus oil at 40°C
PRESSURE bar/psi

207
PRESSURE bar/psi

3000 3000
138 138
2000 2000
69 69
1000 1000

9.5 18.9 28.4 37.9 7.6 15.1 22.7 30.3


2.5 5.0 7.5 10.0 2 4 6 8
FLOW lpm/gpm FLOW lpm/gpm

1.408.1 ®
HYDRAFORCE.com
Blue rectangles are links to other catalog pages.
®
HYDRAFORCE

SV10-40A
DIMENSIONS
SV10-40A Applied to Motor Control Circuits
1.84
DIA.
46.7

0.45
11.4
1.62
41.1

TORQUE
5–7 lb-ft
(6.8–9.5 Nm)

2.38 E-Coil
Standard
Coil View 60.3 View

SV10-40A As Selector Valve SV10-40A in Full Loop


Max Flow 22.7 lpm (6 gpm) Max Flow 37.9 lpm (10 gpm)
TORQUE
24–26 lb-ft
(32.5–35.3 Nm)

MATERIALS TO ORDER
Cartridge: Weight: 0.18 kg (0.40 lb); SV10-40A __ - __ __ __ - __ - __ __ __ __ __
Steel with hardened work surfac-
es. Zinc-plated exposed surfaces.
Buna N O-rings and polyester Option
elastomer back-up standard. None (Blank) Voltage
Standard Ported Body: Weight: Manual Override M 0 Less Coil**
0.36 kg (0.80 lb); Anodized high- Manual Override Y 12 12 Vdc
strength 6061 T6 aluminum alloy, For Manual Override operating 24 24 Vdc
rated to 207 bar (3000 psi). Duc- limits of pressure and flow, see **Includes Coil Nut.
tile iron bodies available; dimen- charts above. For more informa-
sions may differ. tion on manual override options,
see page 1.001.1
See page 8.010.1.
Porting Coil Termination E-Coil D-Coil
Standard Coil: Weight: 0.27 kg
Cartridge Only 0 Deutsch DT04-2P ER (IP69K) DR (IP65)
(0.60 lb); Unitized thermoplastic
SAE 8 8T Metri-Pak 150 EY (IP69K) DY (IP65)
encapsulated, Class H high tem-
Dual Lead Wires EL (IP69K) DL (IP65)
perature magnet wire.
Amp Jr. Timer EJ (IP67) —
See page 3.200.1.
DIN 43650 EG (IP65) DG (IP65)
E-Coil: Weight: 0.41 kg (0.9 lb); Fully Dual Spades — DS (IP65)
encapsulated with rugged exter- For Coils with Zener Diode, add “/Z” to option code.
nal metal shell. Seals
For example: “ER/Z”. Not available on all models.
Rated up to IP69K with integral Buna N (Std.) N See coil option info. on pages 3.200.1 & 3.400.1
connectors. See page 3.400.1. Fluorocarbon V
Polyurethane P

®
HYDRAFORCE.com 1.408.2

You might also like